Transcript
HMIWeb Client Browser Station
Honeywell Enterprise Buildings Integrator™ An integrated facility management solution. PRODUCT FEATURES: • • • • • • •
• Enterprise-wide, Integrated sequences of operation allow events in one subsystem to automatically and directly trigger events in another system. Example: – Tenant activates Fire Alarm pull station – EBI initiates digital video recording and captures the pre-recorded video leading up to the event – Doors are unlocked allowing safe egress while presenting live video to maintain facility security – HVAC initiates proper fan pressurization control for smoke control system operation – Instruction pages and system information is presented to the various operators to manage risk and follow proper emergency procedures • Emergency and routine situations handled with maximum efficiency by bringing the right information together at the correct decision point
• • • •
• Static and rotary station licensing • HMIWeb client and IE browser support • 40 simultaneous clients supported – Operator area segregation and permissions enforced • Multi-Monitor support on single client license • Operator definable alarm and event summaries • Windows 2000 or Windows XP
EBI Server and Redundancy Option
Go to: www.honeywell.com/ebi for additional information regarding our powerful software applications.
• Microsoft Windows 2000, SQL (or MSDE) platform • Remote access server (RAS) supported (see EBI Compatibility Matrix for more information) Server PC Specifications (Standard Performance): • Dell, Pentium 4, 1.7 GHz, 1 GB RAM, 40 GB HD min. • Terminal services support for remote access via PDA or other handheld device • Alarm pager capability for off-site notification including e-mail and SNMP support • Diagnostics tools with remote access capabilities • Quality assurance: ISO 9001, SEI Level 3
W7054A UL Listed EBI Server
Specification Data 74-3201 • Single or dual Intel Xeon processors at up to 3.2 Ghz clock speed • 12 GB SDRAM (max) • 584GB Internal HD storage (max) • 10/100/1000 Gigabit on-board Ethernet • Embedded SCSI and RAID controllers • CD/CDR/DVD and tape backup options
• Client/Server Interface, Cimetrics BACstac • BACnet Ethernet & IP Support • RPM, WRP, COV, BBMD support (See EBI PICs for more information)
EBI HMIWeb Client Stations
• • • •
• HMIWeb browser station utilizing Microsoft Internet Explorer (IE) provides full client access with operator permissions and area segregation enforced • EBI systems with TCP/IP network access and the network server option may also utilize Web Toolkit pages with Active X controls for analog and status point monitoring and control • Web Point Control utilizes Java Applets to allow status point control and allow users to define schedules up to one week in advance
APPLICATIONS:
• Changes made to personnel information in the HR database are automatically sent to the EBI CMS to update area and equipment access information • Events in the EBI CMS sends information to the HR system for time and attendance or after-hours billing reporting for energy and services
• The HVAC system and security system operate independently, and share data to optimize occupancy scheduling, lighting, and energy management strategies based on information from both systems • Cardholder data may be managed from a single client on a single server in a “Traveling Card” concept allowing cardholders to move between sites
Internet Explorer Web Toolkit
Network Firewall
APPLICATIONS:
EBI DSA Server
• Read/write of analog and status points • Item names up to 64 characters
LonWorks® Network
PRODUCT FEATURES:
Integrate multiple servers each performing a different application: HVAC, Security, Life Safety, Industrial Control DSA for points and DSA for cardholders allows Operator Client Stations consistent access to both local and remote points and cardholder data Extends the capacity of a single server solution to support additional points, channels, and controllers Utilizes Windows 2000 Server
OLE for Process Control (OPC)
BACnet, ASHRAE STD, SSPC 135-2001
Applicable for use in UL2050, DoD, DCID, and SCIF high-security applications Approved by ULC for similar applications in Canada Approved by the California State Fire Marshal, NYC/MEA, and additional international agencies See individual product specification data sheets for specific approvals
• • • •
APPLICATIONS:
Monitoring and control of third-party HVAC central plant and unitary equipment, industrial controls, and other systems utilizing Open System Communication Protocols Monitoring third-party Life Safety systems Integrated system sequences of operation History collection, trending, and global scheduling of third-party open systems
Intranet and Internet Access Connectivity options allow access from anywhere in the world via HMIWeb Client and Browser Stations, or web page access via Web Toolkit and Web Point Control optional interfaces.
PRODUCT FEATURES:
• PeopleSoft and SAP Integration to EBI Cardholder Management System (CMS) database for database synchronization periodically or on demand • Generic Cardholder Object Model (CHOM) database integration interface option • Open Database Connectivity (ODBC) support allows read-only access to EBI point, history, and event data for third-party system analysis and reporting
APPLICATIONS: • • • •
Distributed System Architecture (DSA) Provides centralized monitoring for geographically distributed systems, and scalability for large enterprise systems.
PRODUCT FEATURES:
• Client and server support for BACnet, LonWorks, OPC, Modbus, and Advanced DDE • BACnet and OPC discovery mechanisms to simplify engineering and configuration
• UL 864 – UOJZ Proprietary Protective Signaling System – UOXX Control Unit Accessories – UUKL Smoke Control Systems – UDTZ Signal System Units • UL 916 – PAZX Energy Management Equipment • UL 1610 – AMCX Central Station Receiving Unit • UL 294 – ALVY Access Control System Units • UL 1076 – APOU Proprietary Alarm Receiving Units • UL 2017 – QVAX Process Management Equipment • UL 60951 – NWGQ Information Technology Equipment
APPLICATIONS:
r ato gr
Ent er
PRODUCT FEATURES:
Honeyewll EBI is approved for use in the following categories:
The complete solution for the safety and comfort of your people and the effective operation of your buildings Provides an “enterprise view” that goes beyond traditional building automation, fire, and security systems Fully UL listed to provide authorized operators with 2-way command/control of any subsystem from any listed station Allows full interaction between applications to minimize risk to personnel and assets, maximize personnel productivity, and optimize system and equipment efficiency Operator segregation allowing access only to data and information appropriate for the specific user Fully scalable from a single application and controller, to enterprise integration with multiple applications and servers distributed across the Ethernet LAN and WAN Migration platform for a wide range of Honeywell legacy products including Excel Building Supervisor (XBS), Excel Building Supervisor Integrated (XBSi), DeltaNet Excel Plus, MicroCel, MacroCel, Excel Classic, FS90/FS90 Plus, Delta 1000 and Delta 2000
Buildings In te ise pr
Enterprise Systems Integration Share information with personnel, office and financial system databases.
Open System Integration – EBI supports multiple industry standard communication protocols to allow enterprise-wide monitoring and control from a single client workstation.
• Users away from the office may access their EBI system using VPN, or through a thin client access over the internet to check system status, issue commands, respond to alarms, or request reports
EBI DSA Server
ANSI/EIA Std. 709.1 LonWorks Network Services (LNS) Connectivity via: PCLTA, i.LON® 600/1000 EXCEL 5000 Open LON and Excel CARE (see 63-9026 for more information)
EBI Web Point Control
Global HRMS & PeopleTools support
ODBC
Interface to SAP R/3 Human Resources Module
Modbus: Gould, Modbus Plus, Universal Modbus
Advanced Dynamic Data Exchange (AdvDDE) and DDE
Network Firewall
Network Firewall
• Gould Modbus to Modicon 584 and 984 PLCs • RS232 serial interface and Modbus TCP support
• Point monitoring and control
N et w o
Modbus
Network Router/Firewall-14507744 Series 74-3487 Specification Data • Ethernet and T1 interfaces • AES network encryption capable
Corporate Intranet, VPN, or WAN
Wide Area Network/Internet (WAN)
rk
in
gf
unc
Local Area Network (LAN)
Redundant Router (Optional)
ti o ns easily integrate with existing systems and devices.
FS90 LAN Interface Assy- 14006700-598100
NOTE: For UUKL applications, use the i.LON® 1000
TemaLine A Comprehensive Solution for Security
DeltaNet FS90 Capability, Reliability, Expandability
Excel Life Safety System – XLS1000 A High-Performance Life-Safety Solution
Excel Life Safety System – XLS140 Advanced Detection and Networking
PRODUCT FEATURES:
PRODUCT FEATURES:
PRODUCT FEATURES:
PRODUCT FEATURES:
PRODUCT FEATURES:
PRODUCT FEATURES:
74-3671 Specification Data XFC3A06001 Terminals: ....................................... Fixed permanent Digital Inputs: ................................. 4 Digital Outputs: ............................... 4 Analog Inputs:................................. 4 (20K NTC) Analog Outputs: .............................. 2 (VDC) XFC3D06001 Terminals: ....................................... Removable Manual Override:............................. 6 No. of LEDs:.................................... 10 Digital Inputs: ................................. 4 Digital Outputs: ............................... 4 Analog Inputs:................................. 4 (20K NTC) Analog Outputs: .............................. 2 (VDC)
W7750B/C Constant Volume AHU Controller Inputs • 1 T7770 wall module • 4 resistive inputs • 2 voltage inputs • 4 dry contact digital inputs • 1 bypass button input Outputs • 8 triac outputs (W7750B) • 1 LED output • 5 triac and 3 analog outputs (W7750C)
P/N 8003-220 Order # HL-8003220 • Maximum 8 units per system • Arm/disarm specific areas • 6 LED annunciator display
MIRO 32/0 Board in Modular Enclosure
6-Input Concentrator (BIC-6)
P/N 92410023200 • Additional 2 inputs / 24 outputs and 2 SNET ports
P/N 92410021200 • Additional 32 inputs and 2 SNET ports
SNET RS-485
Multiple Output Module (MOM)
74-2942 Specification Data 74-2953 Specification Data • Pressure-independent or pressure-dependent VAV box control • Single-duct/dual-duct VAV box control solutions • Reheat and peripheral radiation control (selectable "first on" sequencing) • Series/parallel fan • Supply/return air tracking • LonMark functional profile 8010
DR4201
92995100082-A Specification Data P/N OS10HON • Contactless smart card reader
DR4205
92995100043 Specification Data P/N 92042050100 • DigiReader with tamper
2-Input Concentrator BIC-2 HU
P/N 8003-284; Order # HL-8003284 (Red actuator buttons for emergency/panic) • 2 supervised inputs • 1 output • Supervised and tamper protected • Remote reset • Distress actuator button
OmniProx™ OP30
92995100063-B Specification Data P/N OP30HON • Mullion size • Typical read range: 4" • Wiegand output • Genuine HID™ compatible
DR4208
92995100012-D Specification Data P/N 92042081000 • HID compatible • SNET and Wiegand connections
Hall Effect Door Switch IV (HEDS IV)
OmniSmart OS30
P/N 8003-283 Order # HL-8003283 • High-security door contact detector • Supervised and tamper proof
DR4205K
92995100012-D Specification Data P/N 92042050000 • DigiReader with integrated keypad – 24 V
i9000 Remote Intelligent Power Supply (RIPS) P/N 8003-217 Order # HL-8003217 • Maximum 7 units per controller • Powered by 16V AC transformer • Two 400mA, 12V DC switched auxiliary outputs • 1A programmable output • Status report to control unit over RS485 comm
OmniProx™ OP40
DR4205K
92995100012-D Specification Data P/N 92042052100 • DigiReader with integrated keypad, 12 V with tamper
9299510082-A Specification Data P/N OS40HON • Contactless smart card reader
92995100012-D Specification Data P/N 92042030000 • Mullion-mount DigiReader
74-2962 Specification Data • Space or return air temperature control • ASHRAE cycles 1, 2, 3 • 8 output for HVAC control • PWM or floating damper control • LonMark functional profile 8080
92995100063-B Specification Data P/N OP40HON • Mounts on single-gang electrical box • Typical read range: 4" • Wiegand output • Genuine HID™ compatible
OmniProx™ OP45
W7753A Inputs • 1 T7770 wall module • 2 resistive inputs • 2 voltage/current inputs • 4 dry contact digital inputs • 1 bypass button input Outputs • 8 triac outputs • 1 LED output
92995100063-B Specification Data P/N OP45HON • Switch-plate size; mounts on a UK size electrical box • Typical read range: 3 – 4.5" • Wiegand output • Genuine HID™ compatible
DR4220
92995100012-D Specification Data P/N 92042200000 • Long-range proximity reader
OmniProx™ OP90
Fan Coil Unit Controller W7752 74-2959 Specification Data • 2 pipe, 4 pipe fan coil unit control • Up to 3 speed fan control • With or without electrical reheat • Space freeze protection • LonMark functional profile 8020 W7752 Inputs • 1 T7770 wall module • 1 dry contact digital input • 1 bypass button input Outputs • 3 relay outputs • 1 LED output • 1 electric heat relay (F type only)
92995100063-B Specification Data P/N OP90-FWS • Switch-plate size; mounts on a US size electrical box • Vandal-resistant cast zinc-alloy design • Typical read range: 2" • Wiegand output • Genuine HID™ compatible
OmniProx™ OP95
Photo ID Station
Remote Input/Output Device W7761A
Evolis Dualys Series
74-2698 Specification Data • Generic I/O for lighting, exhaust fans, pumps, and more LonMark standard objects for sensors and actuators
Logitech® QuickCam Pro 4000
• Up to 140 cards per hour
Logitech P/N 961239-0403
Evolis Pebble Series
W7761A Inputs • 4 resistive inputs • 2 voltage inputs • 4 dry contact digital inputs Outputs • 8 triac outputs
• Up to 140 cards per hour
3Com Watchport V USB Camera ®
3Com P/N 00371800
P/N OP95-FWS • Switch-plate size; mounts on a US size electrical box • Vandal-resistant cast zinc-alloy design with piezo keypad • Typical read range: 2" • Wiegand output • Genuine HID™ compatible
Mifare BioAccess™ Finger Print Reader
92995100070-B Specification Data P/N 92030600200 • High accuracy • Highly secure • Compatible with Magstripe and Wiegand 26-56 bit systems
Communicating Thermostat T7300F/Q7300H
PhotoID MiniTower
Parallel
63-1281 Specification Data • One thermostat model for either heat pump or conventional RTU • Up to three stages of heat and cool • Works with T7047 Remote Temperature Sensor • Proportional plus integral control eliminates temperature fluctuations • 7 day programming - 2 occupied / 2 unoccupied periods per day • Discharge air sensing capability with C7046C Sensor • Conforms to LonMark thermostat functional profile
• Intel Pentium 4 processor, 1000BaseT • Integrated Ethernet adapter, online HD storage configurable to meet customer requirements
Fargo DTC500 Series ®
FlashPoint 3Dx Lite Video Capture Card
• Up to133 cards per hour
Integral Technologies® P/N 3280 • Allows use of any analog camera • Available in PCI or AGP
Fargo Pro-LX ®
• Up to120 cards per hour
Hydronic Controller W7762B/7763C
74-2934 Specification Data • Radiators, induction units and fan coil units with manual fan switching • High efficiency, low cost heat/cool valve application solution • Model with integrated or remote module for wall or unit mounted • LonMark functional profile 8020
FlashBus MV Lite Video Capture Card
Parallel
Integral Technologies® P/N 3047 • Allows use of any analog camera • Only available in PCI
W7762/3 Inputs • 1 space temperature sensor (either built in or via T7770 wall module) • 1 dry contact digital input Outputs • 1 relay output • 4 triac outputs
HVAC Controls
*LONMARK is a trademark of Echelon Corporation
Security and Access Control
XLS1000 F&S Bus Interface - 14507532
74-2771 Specification Data Fully compatible with the DeltaNet F&S bus architecture, this interface allows XLS1000 controllers to co-exist with the FS90 on the F&S bus, providing a seemless migration path for customers
DeltaNet FS90 Access Management Controller (AMC)
74-2438 Specification Data FS90 functions or operate as a dedicated access system • Fully integrated with EBI • Support for major access card technologies, including magstripe, barrium ferrite, proximity, Wiegand, and biometric readers • Complex access control applications such as elevators control, multi-level anti-passback, two-card, supervisor rules, PIN support, and over 200 schedules per controller
DeltaNet FS90 Fire Management System
74-3154 Specification Data Single and dual channel audio with optional fire warden telephone FCS function boards provide: • Audio and phone control (for fire signal and evacuation message output, all-call paging of multiple speakers) • Speaker and phone selection (for individual selection of speaker and phone circuits, all-talk two-way communication with multiple phones, optional phone page to address audio speakers from a fire fighter telephone) • Heating, ventilating, and air conditioning (HVAC) override (for two and three-position control of fans, dampers, and other non-audio equipment)
74-3481 Specification Data • High-contrast lines and text • LCD displays custom text messages in graphic annunciator enclosure - Firefighters smoke control station options - Agency listed with Honeywell control panels - Surface or semi-flush mounting with optional trim - Field-installed modification of graphic with optional graphic transfer kit
Excel Life Safety System – Remote Annunciator
74-2888 Specification Data • Backlit LCD display provides 168 characters - Displays information important to user - Hands-free, first and last event with highest priority • LCD display uses queues to sort events • Variety of cabinet configurations size the annunciator to the application • Programmable LED flash rates • Slide-in custom labels
P/N TK_C02, TK_C03 HID Compatible • NEURON CHIP™ 3150 (Echelon) 32 KByte EPROM to download application firmware • LonWorks™(Echelon) connection to the TS_AC01 unit with a transfer rate of 78 kbps • Alphanumeric graphic liquid crystal display (LCD), back-lit, with two lines of 16 characters • Reader for proximity cards, HID with TK_C03, (standard ISO/ABA 125Khz, up to 5cm reading distance) • Numeric-function keyboard with 16 keys • 1 double-colored LED signal: green LED for the correct reading and red/yellow for invalid • Variable tones for valid/invalid transactions • Management of two dry contact digital inputs to control the door status • Management of two relay outputs (1A@30V) to command door unlock and signal external outputs • Tamper protection of the unit to prevent opening
*Tema Key – Magnetic Reader
P/N TK_C01 • NEURON CHIP™ 3150 (Echelon) 32 KByte EPROM to download application firmware • LonWorks™(Echelon) connection to the TS_AC01 unit with a transfer rate of 78 kbps • Alphanumeric graphic liquid crystal display (LCD), back-lit, with two lines of 16 characters • Bi-directional reader with manual swiping for magnetic cards (track 2, ISO/ABA 7811 standard). • Numeric-function Keyboard with 16 keys • 1 double-colored LED signal: green LED for the correct reading and red/yellow for invalid • Variable Tones for valid/invalid transactions • Management of two dry contact digital inputs to control the door status • Management of two relay outputs (1A@30V) to command door unlock and signal external outputs • Tamper protection of the unit to prevent opening
FS90 Control and Communication Function Boards
85-3001 Specification Data • Modular and expandable, graphic annunciators display the information required by each job site • LDM input/output modules communicate via RS485
Board
Function
Part Number
Function
14505104-005
CA
FS90 control/CPU board
3-DSDC
Dual SIGA data controller with one SIGA data board; mounts to local rail
14506344-001
LJ
RS485 communications and display board
3-AADC
Analog addressable data loop controller; mounts to local rail
14506690-001
LJ
Leased line communications and display board
14506302-003
CC
Audio control board
14506302-004
CE
Fire telephone control board
Part Number
Function
14506302-002
SB/SD
Two position manual switch – 4 circuits
3-LDSM
LED display support module
14506302-001
SH/SK
Three position manual switch – 4 circuits
3-24R (Y/G)
24 red LED display module (yel/grn)
3-12SR (Y/G)
12 switches/12 red led display/control modules (yel/grn)
3-12RY
12 red LED and 12 yellow LED display modules
3-12/S2Y
12 switches, each with 2 yellow LED display/control modules
3-12/S1GY
12 switches with one grn and one yel LED per switch
3-12/S1RY
12 switches with one red and one yellow LED per switch
3-6/3S1G2Y
6 groups of 3 switches; each switch has (1) grn, (2) yel LEDs
3-6/3S1GYR
Control/display module with six groups of three switches; each switch has one grn, yel, red LED
Part Number
Function
ICM-4RK
NAC module, provides four style Y (Class B) or Style Z (Class A) circuits
CRM-4RK
Control relay module, four form-C relay contacts per circuit
VCM-4RK
Voice control module, provides four Style Y and Style Z speaker circuits, eight manual select switches and indicators
DCM-4RK
Dual channel module provides four class B or class A speaker circuits
XLS-VCC-1B
Voice control center; provides a variety of user-selectable tones on a single channel
XLS-TCC-1B
Telephone Control Center; provides a stand-alone two-way Fire Fighters telephone (FFT-7S)
FFT-7 FFT-7S
Fire fighters telephone control with master handset
AA-30
Audio amplifier, 30 watts
AA-120
Audio amplifier provides up to 120 watts of audio power (25 VRMS) for the XLS140
AA-100
Function
ACPS-2406
6.0 amp addressable charger power supply
FCPS-24
The FCPS-24 is a remote six-amp (four-amp continuous) repeater/power supply
FCPS-24S6/-24S8
Remote six-amp and eight-amp power supplies with battery charger
XLS-NET Twisted Copper Pair
Board
Function
AA
Class “B” initiating device circuit – 4 zones
14505108-001
AB
Class “A” initiating device circuit – 2 zones
14505106-002
AC
Class “B” initiating device circuit – 4 zones – contact input only
14505118-001
AD
Digital input – 8 circuits, unsupervised
14505132-002
AE
Intelligent detection loop (slc) - 2 circuits per board
3-ZA20A/B
20W zoned amplifier; selectable for 70 or 25 Vrms operation
14505188-001
AF
Class “B” secure/access circuit – 4 zones, with local control
3-ZA40A/B
40W zoned amplifier; selectable for 70 or 25 Vrms operation
14505188-002
AG
Class “B” secure/access circuit – 4 zones, no local control
3-ZA90
90W zoned amplifier; selectable for 70 or 25 Vrms operation
14506432-001
AH
Class “B” ul grade aa high-security circuits
3-PPS/M
Primary power supply with local rail module 120v, 50/60 hz
14505110-001
BF
Class “B” notification appliance circuit – 2 NAC circuits, 2 N.O. Relays
3-IDC8/4
Initiating device circuit module
14505110-002
BG
Class “A” notification appliance circuit – 2 NAC circuits
3-OPS
Off premises signaling module
14505116-001
DB
Digital output – 8 circuits
3-ASUFT
Audio source unit with local microphone and firefighter’s telephone
14505112-001
DC
Accessory relay board - 4 SPST N.O. OR N.C. relays
3-CPU1
Main panel processor
3-LCD
Main display interface with LCD
3-RS485A/B/R
Network communication board
Part Number
Function
3-RS232
RS232 communication board
RPT-485
3-FIB/A
Fiber optic communications interface
Repeats EIA-485 over twisted pair or converts to fiber-optic medium
3-MODCOM(P)
Modem communicator DACT with duplex V.32 bis 14.4K baud modem
XP5
The XP5-M and XP5-C provide FlashScan® transponder points
3-NSHM1/2
Network short haul modem communications interface with modem connections
XP
3-SAC
Security control module
The XP series transponder provides conventional monitor and control points in CLIP (standard polling of each intelligent device) mode only
XLS-KPDISP
Keypad/display module
XPIQ
The XPIQ quad intelligent voice transponder for distributed multichannel voice evacuation systems, an integrated audio amplification and distribution subsystem controlled by FACP. Capable of playing up to four simultaneous messages. Accepts up to four 25-watt amplifiers.
Part Number
Function
3-BATS
Battery shelf for XLS-RCC enclosures; space for one 65 AH or two 50 AH batteries
3-BTSEN
Battery sensor/distribution module
3-TAMP
Tamper switch for 3-CAB7, 3-CAB14 and 3-CAB21 cabinets
3-TAMP5
Tamper switch for 3-CAB5; mounts to side of cabinet
3-TAMPRCC
Tamper switch for XLS-RCC series cabinets; mounts to side of cabinet
32004129
XLS1000 high-security interface for UL 1076 Grade AA security for up to eight zones
32003193
• • • • • •
Annunciator/Control Modules Function
ACS
Annunciator control modules ACM-16AT, AEM-16AT, ACM-32A, and AEM-32A
AFM
Annunciator fixed modules AFM-16A, AFM-16AT, and AFM-32A
LDM
Lamp driver modules LDM-32, LDM-E32, and LDM-R32
SCS
Smoke control station; eight (expandable to 16) circuits
Photoelectric
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Low-profile design, low current draw Tamper-resistant wiring base Integral insect resistant screen to reduce nuisance alarms Dual LEDs provide 360-degree viewing Optional remote LED annunciator Built-in test mechanism Environmental compensation Pre-alarm sensitivity capability Continuous self-diagnosis and storage of environmental and operational data Day/night sensitivity adjustment One red and one green status LED Standard, relay, and fault Isolator mounting bases Design and manufacture per ISO 9001 standards Thermistor sensing circuit for fast response Rate-of-rise detection model available Dual sensor LEDs provide 360-degree viewing Modern low-profile design Compatible with Honeywell CLIP and FlashScan loop transmission 135°F (57°C) fixed temperature detector type Combination 15°F (9°C) per minute minimum rate-of-rise and/or 135°F (57°C) fixed temperature detector type Electronic addressing and device mapping Continuous self-diagnosis and storage of environmental and operational data Standard, relay, and fault isolator mounting bases Automatically optimizes performance for each installed location Continuous monitoring of detector sensitivity Digital pulse-width encoded communication with noise immunity Compatible with Honeywell CLIP and FlashScan™ intelligent High-density Filtrex™ filter eliminates the need for sensor cleanings Filtrex™ filter self-monitors clogs and reports a trouble condition at the panel when replacement is needed Two sensor LEDs provide status indication at the control panel Provides rotary-decade switches to set sensor address Fast response to detect very early particles of combustion Ultra-high sensitivity capability On-board drift compensation Transient rejection algorithms Environmental tracking Wide sensitivity range
• • • •
Environmental compensation Wide 0.67 percent to 3.70 percent/ft. sensitivity range Pre-alarm sensitivity capability High ambient temperature operation (up to 100°F [38°C])
XLS-IS
*Tema Power – Power Supply Unit
TC808
XLS-HFS
Ionization
Ionization
Photoelectric
Thermal 135° ROR/FT 190° FT
Fixed Temperature 135° FT
XLS-HRS
Rate of Rise
TC840 Acclimate
Multi-Criteria Photoelectric Thermal
TC844 Filtrex™
Harsh Environment Photoelectric
TC846 Pinnacle™
Ultra-High Sensitivity Laser Smoke Detector 0.02% - 2.00%/ft Obscuration
XLS-IPHS
MultiCriteria Ion, Photo, Heat
Fire and Life Safety Systems
mm
Ana og Came as m
m
m
m D M
R O
M
G
M
m
NW N D M
m
N
m
m
N
XLS1000 Yes
XLS140 Yes
Pan T H O
w
D M OR m D
Yes
W
U
D m
D
U
W D G
w
G
Yes
Yes
Yes
Yes
Yes
Yes
w
m
W
R Q W
N
N
O m
m
D D
D
m
w
m
m
m
w
m
m
m
m W
A ch ec u e Op ons M
m
R
m
m
m
M
w
D
LON® 600 Rou e
m
w N
ON
w
ON
w
w
m
w
m
w
m
m
Me e s
m m
W M m
w
n e na ona a on
Me a Moun Tags P N AT 132 M AT 132 M B AT 132 M BA R
w m
m
m m m m m m m M
N
m
m
O
m
w
m
M R M GH m M m W w
M
Pe sonne Tags P N AT 132 P AT 132 P B O
m
w
R D
Veh c e Tags P N AT 132 V AT 132 V D m
m
w m
w
m
W
O
w w
m
M M
M
M
m
m m m
R m
m
m
m
m
m
m
m m
M
R
w
w
w
m
m
m
m
w
m
m
m
m m M&
m
D
m
m m m m m m
W s S ap P sone Tag P N AT 132 W
m
w
m
R
R
m
w D m
m m m m
L cens ng
w
m
w
M
R
m
w
mm
C en Requ emen s
m
m
D
Se ve Requ emen s
m
M M
Ca go Tag P N AT 132 L w
www m w M m m www w m m D www m W N www m
W M
w
R
R m w
m m
m
m
R
w R w
w R
m
m
R
R w
m
m w
w w
W M
m
m w R N
m Q RR
W
M O
Key Fob Tags P N AT 132 PF R AT 132 PF C AT 132 RF
RR
m
CCTV & Digital Video
w
m
W
N
RR
m
Me e Managemen
N
R
m
RR
m
N
m
m
w
m
En e p se Demand Managemen
Asse Tags P N AT 132 A AT 132 A B AT 132 A T AT 132 BT
m
Ova Equ pmen Tag P N EQB00901 EQB00903 & WSE00433
Yes
Yes
w
m
R
m
m
m
m
w
w
R
w
w
W
Yes
Yes
m
m
R
m
m
m
Axcess Tag S y es
Rec angu a Equ pmen Tag P N ETB00433 & ETF00433 m RR O
Yes
m
w
es Suppo ed
U
N N
N w
RR w w m m &
w w
N
m
m
m
RR
m W
W
R w
m
U
w
P c u e F ame Ac va o An enna P N AT 132 A F8 & AT 132 A F10
A e Tag P N ALB00001 PLB00001 & ART00433
D m D m G O
w
D
w
m
RR w
m
m
m N
R
m
m
Yes
Yes
w
N
R RR
D m O U m D m R D w DM
N
m
D
G W
w
mM m
w
W
U
w
w
Pe sonne Tag P N ERS01201 PBE00433 & ETB00433 2
m
w
w
R
Yes
m
m
Zoom PTZ Came a Suppo
D m M
Yes
m m
w
m
Bene s o Ene gy Manage
m
P ex Ac va o An enna P N AT 132 A PT & AT 132 A PW
ON
m
mm
m
mM
H
m
m
R
W
Compatibility FS90 Yes
m
m
m
w
M
N
w m
D
D
R
w
RR
w m N w
m
m
W s Mo he Pa en Tag P N PWB00901 & EWB00001
m
w
m
m
R
Baby Tag P N BTB00433
G
N
w
m w
w
w
M
w
w
m
R
ON ON ON
F xed Came a Suppo w
m
m w
m
m
m
m
R
H
R W
D
m
m
w
w
m m m
m
m
Ene gy Manage Founda on
NR NR
Ove head Ac va o An enna P N AT 132 A PO
Junc on Box P N FJB00001 & EJB00001
m
H
m R
m
E pas Tag S y es
NW N M
m
Road Loop Ac va o An enna P N AT 132 VL S & AT 132 VL D
®
R
m
Q w MD
m m
Ped a c A he me s Tag P N PTA00433
O
TC806
m
M G O m
M
H
Features
TC807
m U
w
D W
m m
ON
LF Reade P N RLF00001
m
N
m
R
ON
MH m
G
m N w
m
m m
F ex Ac va o An enna P N AT 132 A F
R O
W
N N
m
m
W
m
AXIS:............................................... 2100, 2110, 2120, 2130, 205 (MJPEG)
m
N
RF Reade P N RDF00001
H
MH
O w
ON
R
m
m
R
W
m
m
m
Ac va o P N AT 132 AT & AT 132 AT D
Ex e na Re ay Box P N NXB00001
M
W
m
m
G
m
R
m
m
W W
w
m
m
m
m m
m
MH
m
w
w
m
m
Communication Interface Modules
Excel Life Safety Sensors Type
R R
IP Network cameras combine the video encoding and streaming functions of the video streamer with a security camera. Digital video streams that are transmitted across a standard LAN/WAN to DVM Camera Servers for indexing and storage. Use Axis Communications
V deo Encod ng and S eam ng
m
m
IP Network Cameras
Part Number
w
R m
m
R R
m R
m m
RF Rece ve P N AT 132 NR P & AT 132 NR S
m
R Reade P N RDT00001
Simple Network Management Protocol (SNMP) IEEE 802.1D bridging capability and loop detection IEEE 802.1Q tagged VLANs IEEE 802.1 traffic prioritization for multiple QoS levels Support for multicast traffic Non-blocking, wire-speed access across all ports
O m
APPL CAT ONS
m
w
U U
DVM Communicates using TCP/IP network protocol using industry-standard Ethernet technologies. The network switch links the video streamers to the camera server(s) and camera servers to clients
XLS1000 panel mount printer
Model
w
Use off-the-shelf storage network switches with the following minimum specifications:
Part Number
m m
Phys ca Laye Repea e PLR P N ERS02001
Network Switches
R
Unde s and and Con o Ene gy
PRODUCT FEATURES
m
R
w
m
w
RAID Levels: ................................... 0, 1, 3, 4, and 5 Redundancy: ................................... Hot-swappable drives, hot-sparing, redundant power supplies, redundant RAID controller Drives Supported: ........................... 4, 8, 14, or 42 Drive Types: .................................... Ultra ATA/133, Ultra ATA/100, or SATA Data Rebuild: .................................. 40GB storage RAID Controller:.............................. RAID-5 fault tolerant storage, capacity dependent on application SCSI Interface:................................ SCSI Ultra160 O/S Supported: ............................... Windows 2000
w m
R
LON® 600 Rou e
Use Promise, NexSan or other off-the-shelf storage subsystem with the following minimum specifications:
Power Supplies
Accesories
R
M
Provides additional fault tolerant (RAID-5) video storage. Scales from 10’s to 100’s of terabytes. DVM supports any Windows 2000-compatible off-the-shelf storage device including Direct or Network Attached Storage (DAS or NAS) or Storage Area Network (SAN) systems
Use the AA-100 for 70.7 VRMS systems and 100 watts of power
14506106-001
XLS-PS
P/N TP_U01 (0.8A), TP_U03 (4.5A) • LonWorks™ (Echelon) connection to the TemaServer control units, with a communication speed of 78 kbps • Protection from power overloads • LED signal: green LED for “correct functioning,” flashing red for “errors in the communication signal,” red for “device out of order” and yellow for “Echelon connection is active” • Lead battery backup, with full functionality for 4 hours in case of network failure • Tamper protection of the unit to prevent opening
Network control annunciator, 640 characters
Part Number
*Tema Key – Dual Wiegand Interface P/N TK_S014 • NEURON CHIP™ 3120 (Echelon) • LonWorks™ (Echelon) connection with a transfer rate of 78 kbps • 2 balanced inputs with a range between 0 and 12 V • 2 powered open collectors output, holding current 1.2A, peak max 5A inductive load • Tamper protection of the unit to prevent opening
80-character backlit LCD display with keypad
XLS-NCA
w
Optional Video Storage Subsystem (Promise Technology or NexSan)
Notification
Modules, Amplifiers, Power Supplies and Boards
Fire/Security Function Boards
KDM-2
R
Uses off-the-shelf PC with the following minimum specifications:
Excel Life Safety System – LDM Series Graphic Annunciators
Central processing unit with integral 3.0 amp power supply
m R
APPL CAT ONS
Processor:....................................... Intel Pentium IV 1GHz or greater (Dual processors recommended). System Memory: ............................ 1GB RAM Floppy: ............................................ 3.5”, 1.44MB CD ROM:......................................... 24X or greater System Storage: ............................. 40GB storage Video Storage: ................................ RAID-5 fault tolerant storage, capacity dependent on application Input Devices: ................................. Standard Windows keyboard, mouse Monitor: .......................................... 15” SVGA color Operating System: .......................... Windows 2000 Server
m
E pas
m m
Stores video streams and transmits video to clients. Number of database servers required dependent on application, minimum of (1) per system
Ene gy Manage
m
R
DVM Camera Server
85-3002 Specification Data • 16 gauge steel with locking doors • Right- and left-hand hinge • Trim rings for semi-flush mounting • Cabinets available in 4 sizes (C size shown) to accommodate job site requirements
Function
m
R R
m
Asse Loca o
Processor:....................................... Intel Pentium IV 1GHz or greater (Dual processors recommended). System Memory: ............................ 1GB RAM Floppy: ............................................ 3.5”, 1.44MB CD ROM:......................................... 24X or greater System Storage: ............................. 40GB RAID-1 storage Input Devices: ................................. Standard Windows keyboard, mouse Monitor: .......................................... 15” SVGA color Operating System: .......................... Windows 2000 Server
Excel Life Safety System – XLS-CAB-4 Series
XLS140-CPU
H
Axcess
PRODUCT FEATURES
w
m
Uses off-the-shelf PC with the following minimum specifications:
85-3008 Specification Data • 640 character – enhanced LCD display • Printer, CRT, and keyboard interfaces • User interface for all points in all nodes on the system • Can be used as a separate annunciator or combined in the XLS140 cabinet • Supports additional 32 remote ACS annunciator modules
Part Number
m
w
m
Manages the DVM system. Contains recording index, audit log, and web server (1) database server per system (1) optional redundant database server per system
Excel Life Safety System – XLS-NCA
XLS1000 Primary System Components
Part Number
m
DVM Database Server
XLS140 Primary System Components Supports communication on: • Twisted pair copper • Single and multimode fiber optic cable • Existing dry telephone lines
m
w m
PRODUCT FEATURES
85-3001 Specification Data • One, expandable to two, isolated intelligent Signaling Line Circuit (SLC) Style 4, 6, or 7 • Up to 159 detectors (any mix) and 159 modules per SLC • Standard 80-character display, 640-character large display, or display-less (a node on a network) • Network option – 103 nodes supported (XLS140, XLS-NCA Network Annunciator) using wire or fiber-optic connections • Selectable system sensor strobe synchronization
Excel Life Safety System – Flexible Network Communications
*Tema Key – Digital I/O Module
P/N TK_C21 • NEURON CHIP™ 3120 (Echelon) • 4 balanced inputs with a range between 0 and 12 V • 4 open collector outputs with a range between 0 and 12 V up to 100mA • LonWorks™ (Echelon) connection with a transfer rate of 78 kbps • Tamper protection of the unit to prevent opening
Software-based digital CCTV video management platform Uses off-the-shelf PC, storage, and networking hardware Live viewing and playback while recording Camera pan/tilt/zoom control from any client on the network Continuous, scheduled, alarm, pre-alarm motion, and user-activated recording modes Up to 30fps performance on all channels Communicates using TCP/IP network protocol using industry-standard Ethernet technologies Full integration with EBI including direct access to alarm recordings from EBI alarm/event summary display • High-speed SQL-based search engine (date, time, camera, operator, point, alarm) • Digitally signed recordings and audit trail • Redundant server for complete fault tolerance (optional)
w
R
XLS-NET Fiber Optic Cable
RS485 Audio & Data Twisted Copper Pair
Excel Life Safety System – Envoy Annunciator
H
• • • • • • • •
Excel Life Safety System – XLS140
*Tema Key – Proximity & HID Reader
OmniSmart OS40
DR4203
Unit Ventilator Controller W7753A
92995100082-A Specification Data P/N OS30HON • Contactless smart card reader
P/N TS_AC01 • CPU68EN302 bi-processor including a 68000 (32 bit architecture) and onboard Ethernet controller • Dialer support with LAN or as a backup to LAN • Industry standard LON architecture • Fault tolerant controllers and power supplies • Management of up to 8 doors with TemaKeys on both directions • Management of up to 64 I/O • 1 MB FLASH EPROM to download application firmware via FTP • Up to 60.000 cardholder capacity • Up to 40.000 transactions buffer • Peer-to-peer communication for fast front-end independent decision making • Onboard clock/calendar chip with automatic management of DST • Onboard battery backup, with full functionality for 4 hours • Full Time and Attendance functionality
Twisted Pair
Ethernet
Ethernet
OmniSmart OS10
P/N 8003-242; Order # HL-8003242 (White actuator buttons)
W7751B, D, F • 1 Expanded input/output capacity actuator not included Inputs • 1 T7770 wall module • 2 resistive inputs • 1 voltage input • 3 dry contact inputs • 1 bypass button input Outputs • 8 triac outputs • 1 LED output
*Tema Server – Control Unit
92995100063-B Specification Data P/N OP10HON • Lowest profile HID compatible card reader • Typical read range: 2 - 3" • Wiegand output • Genuine HID™ compatible
2-Input Concentrator BIC-2
W7751H Inputs • 1T7770 wall module • 1 resistive input • 1 voltage input • 1 bypass button input Outputs • 4 triac outputs • 1 LED output • Integrated actuator
P/N 92410000400
OmniProx™ OP10 92995100012-D Specification Data P/N 92042011000 • Low profile DigiReader (HID compatible) • SNET and Wiegand connections
P/N 8003-286 Order # HL-8003286 • Supervised and tamper protected • 8 opto-coupled outputs • 7 segmented LED point/alarm display window
VAV Box Controller W7751
WIRO 4/8/4 Modular Double Board Enclosure
MIRO 2/24 Board in Modular Enclosure
P/N 8003-238 Order # HL-8003238 • Supervised and tamper protected • 6 supervised inputs/outputs • 7 segmented LED point alarm/trouble display window
92995100050-D Specification Data 92995100049-D Specification Data P/N 92410034840 • Additional 8 inputs / 4 outputs and 4 Wiegand ports
74-3154 Specification Data Any DeltaNet F&S system, whether stand-alone or connected to a higher-order system, can include an optional command center for alarm and trouble message display and optional printout, and for data display and entry from a keypad
74-2073 Specification Data • Modular system designed for medium to large building and campus applications • 168-character LCD automatically displays system messages and alarms • 64 node, 160,000 points with 3-second alarm response over any size network • Total network wring over 300,000 ft (91,440m) • 250 devices per loop, 2500 devices per node • 750 ms signature loop alarm response • Every point can be viewed and controlled from any node • Digital storage and transmission of eight multiplexed channels of audio for unmatched intelligibility • Local, proprietary and central station operations with integral alarm printer option • Modem communicator option with DACT functionality • Graphic, text/LED, and keypad/display annunciator options • Listed for suppression releasing and smoke control applications
PRODUCT FEATURES:
High-speed/patented smoke detection technology: • FlashScan® Intelligent features • Poll 318 devices on each loop in less than one second • Activate up to 159 outputs in less than three seconds • Fully digital, high-precision protocol (U.S. Patent 5,539,389) • Advanced Warning Addressable Combustion Sensing (AWACS™) — nine levels • Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515) • Automatic detector sensitivity testing
Asse Loca o
Asse Loca o A ea me oca on ack ng and mon o ng so u on o peop e and equ pmen
Digital Video Manager (DVM) - A Flexible, Highly Integrated CCTV Solution with Advanced Capabilities.
As a stand-alone small-to-medium system, or as a network of distributed panels, Honeywell’s XLS140 intelligent fire alarm control panel meets virtually every application requirement. Designed with modularity and for ease of system planning, the XLS140 can be configured with just a few devices for small building applications, or for integrated campus and commercial installations.
XLS-NET Telephone Lines
Area Keypad (KID)
WIRO 4/8/4 (board only)
DeltaNet FS90 Fire Command Center
Audio & Data Fiber Optic Cable
P/N 92410020200 • Additional 16 inputs / 8 outputs and 2 SNET ports
P/N TS_TA31 • CPU68EN302 bi-processor including a 68000 (32 bit architecture) and onboard Ethernet controller • Bi-directional reader with manual swiping for magnetic stripe cards • Multi-language management of the user interface • Up to 15.500 cardholder capacity with full time and attendance functionality • Up to 65.000 transactions stored on a removable cartridge with Flash EPROM • Lead battery backup, with full functionality for 4 hours in case of network failure • Tamper protection of the unit to prevent opening
74-3154 Specification Data • Conventional and intelligent detection and signaling • Stand-alone operation and/or integration with higher order systems • Function boards for configuration to site requirements • Easily changeable data file in nonvolatile memory • Auto-tuning sensitivity • Communication to panels via dual twisted pair, leased telephone lines, or fiber optic cables
Honeywell LifeSafety Manager™ provides unprecedented protection of your building’s assets and occupants. This life-safety application incorporates: • Intelligent, microprocessor-based devices, including multi-sensor detectors that provide early warning of smoke and fire conditions, and virtual elimination of nuisance alarms • Advanced distributed, digital audio communication system facilitating safe, orderly evacuation of occupants • Rapid and reliable fire alarm controller peer-to-peer communications network • Integral firefighters telephone communication system • Emergency paging to support storm warning and hazardous materials (HazMat) notification • Control of the facilities’ HVAC equipment, such as fans and dampers, to contain smoke and create safe havens • Releasing of fire doors to permit safe exit • Sprinkler supervisory status of suppression systems, sprinkler valves, and fire pumps
Excel Life Safety System – XLS1000
Short Haul Modems 24 ga Telephone Lines
MIRO 16/8 Board in Modular Enclosure
*Tema Server – Magnetic Terminal
Flexible Network Communication Topology
DeltaNet FS90 Fire and Security Controller
SMOKE
W7750A Constant Volume AHU Controller Inputs • 1 T7770 wall module • 1 resistive input • 2 dry contact digital inputs • 1 bypass button input Outputs • 6 relay outputs • 1 LED output
SNET RS-485
P/N 8003-277 Order # HL-8003277 • Maximum 4 units per system • Status display and local control • 2 line x 24 character LCD display
P/N TS_TA32, TS_TA33 • CPU68EN302 bi-processor including a 68000 (32 bit architecture) and onboard Ethernet controller • Bi-directional reader with manual swiping for proximity cards • Multi-language management of the user interface • Up to 15.500 cardholder capacity with full time and Attendance functionality • Up to 65.000 transactions stored on a removable cartridge with Flash EPROM • Lead battery backup, with full functionality for 4 hours in case of network failure • Tamper protection of the unit to prevent opening
P/N HK-2 • Hand geometry reader • Up to 32512 users with memory upgrade • Direct enrollment integration to EBI • Outdoor version available
Leased Telephone Line
Control Center 2 (CC2) Keypads
HandKey II
Lon
74-2956 Specification Data • Proven PID space temperature control algorithm • Integral or packaged economizer control • Separate intelligent recovery rates for heating and cooling • Demand limit control temperature setpoint in energy saving direction • LonMark profile 8030
*Tema Server – Proximity Terminal
HEAT
1 XFR522 Module Type: .................................. Manual override for XFL522 Manual Override Switches: ........................................ 8 2 XFR524 Module Type: .................................. Manual override for XFL524 Manual Override Switches: ........................................ 6 3 XSL511 Module Type: .................................. Connector module for XFL521, XFL522, XFL523, XFL524 4 XSL512 Module Type: .................................. Manual disconnect module between terminals and I/O modules 5 XSL513 Module Type: .................................. Terminal block for XFL521/522/523 6 XSL513 Module Type: .................................. Terminal block for XFL524
Constant Volume AHU Controller W7750
Building on the base FS90 system architecture, the family includes: • DeltaNet FS90 System for conventional zone alarm verification, cross-zoning, annunciation, control, individual zone alarm, supervisory and trouble indication, zone disconnect switches, and a local audible signal. Security functions include local and remote secure/access switching and high-security line supervision • DeltaNet FS90 Plus System (“FS90 Plus”) for intelligent functions to monitor and control individually addressable fire and security devices. FS90 Plus can have up to nine Intelligent Loop Interface Boards, each of which can have two 2-wire circuits or one fault-tolerant 4-wire circuit • DeltaNet Access Control for monitoring and control of up to eight card readers and/or keypads per controller. The system supports multiple card technologies, multilevel antipassback, two-card access, supervisor-required access, and elevator control
SPECIAL APPLICATIONS
Distributed Input/Output Accessories
COMM 1 RS-485 COMM 2 RS-485
I/O Point Capacity • 22 physical points • Up to 256 pseudo points • 46 network variables supported on the LonWorks® Network Application module: ........................ Flash–EPROM Engineering tool:............................. Excel CARE
P/N 92410250030 Base 2-door Controller P/N 92410000300 Star Controller Modular Enclosure P/N 92410450020 4-door Chipset P/N 92410850020 8-door Chipset P/N 92411650030 16-door Chipset • Base two-door system can be field upgraded to a 16-door unit • On-board integrated 16 inputs and 4 outputs • Can monitor 255 inputs and control 96 outputs • Modular upgrade options for easy customization and expansion • Switch selectable baud rate and address for ease of installation • Elevator control up to 96 floors • 100,000 cardholder capacity • S-NET dual twisted-pair wire installation for readers and inputs • 2 on-board Wiegand ports expandable to 16 • Ethernet, RS-232, RS-485, and dial-up host communications • Built-in automatic battery charging system
The DeltaNet FS90 Fire and Security (F&S) family of real-time, microprocessor-based controllers offers conventional and intelligent fire detection and annunciation, security, and access control.
TemaLine is redefining the concept of integrated security solution subsystems for today and tomorrow. • Designed for unparalleled system reliability and availability using the “Shared Load” concept • New distributed architecture and modularity reducing the management load on the supervisory system • Multi-application/multi-functional controller provides access control, time and attendance and intruder protection • Optional redundant TemaServer and “Shared Load TemaPower” • Single standalone application to a fully integrated EBI solution
NexSentry Star II Controller (board only)
Specification Data 74-3035 P/N 8003-332 Order # HL-8003332 • Monitors multiple areas (8 areas maximum) • 62 device modular architecture capacity • 512 input points with precise identification • 64 output points to various equipment and accessories • 99 user IDs • 4 authority levels limiting access to selected functions • Area access – limits access to selected areas • Language preference personalized to each user • 2 RS-485 communication lines • Power supply included
Wiegand
74-2145 Specification Data Analog Input XFL521B Module Distributed Module Type:................ Analog input No. of Inputs: ................................. 8 Type of Inputs................................. 0 to 10 volts ........................................................ 0 to 20 mA or 4 to 20 mA ........................................................ 20k NTC ........................................................ PT1000 Accessories:.................................... 3 4 5 Analog Output XFL522B Module Distributed Module Type:................ Analog output No. of Outputs: ............................... 8 Type of Outputs: ............................. 0 to 10 volts No. of LEDs:.................................... 8 Accessories:.................................... 1 3 4 5 Digital Input XFL523B Module Distributed Module Type:................ Digital input No. of Inputs:.................................. 12 No. of LEDs:.................................... 12 Accessories:.................................... 3 4 5 Digital Output XFL524B Module Distributed Module Type:................ Digital output No. of Outputs: ............................... 6 No. of LEDs:.................................... 6 Type of Outputs: ............................. 6 Isolated changeover contacts Accessories:.................................... 2 3 4 6
®
USB
Distributed Input/Output Modules
®
i9000 Control Unit
Ethernet
74-3666 Specification Data
NexSentry Star II controller changes access control standards by offering easy installation, modular components at an affordable price for the most demanding access control applications. • Modular architecture allows for easy upgrades to future technologies • Advanced digital technology with embedded Intel 32 bit microprocessor provides the fastest response in the industry • Support for multiple access technologies including Digital Proximity, Magnetic Strip, Smart Card, Key Pad, and Biometrics
Fiber Optic Cable
The Intelliguard 9000™ (I9000) is a protection system designed to detect intrusions and other critical conditions when used with the Enterprise Building Integrator™ (EBI) • The I9000 monitors multiple areas, receiving input and providing localized reporting and control. A single I9000 control unit can simultaneously monitor many different buildings, areas with high-security door sensors • Other compatible detectors and output devices can be added to the system, such as motion sensors, sound detectors, lights, sirens, and buzzers • Multiple regulatory agency listings • Meets high-security UL Grade AA requirements • Multi drop EBI configurations (3 i9000's) using RRI and RS-485 bus wiring or Cobox/Ethernet
USB
C-Bus or LON
74-2036 Specification Data I/O Point Modules Analog Input XF521A Insert Card Module Type: .................................. Analog input No. of Inputs:.................................. 8 Type of Inputs:................................ 0 to 10 volts ........................................................ 0 to 20 mA or 4 to 20 mA ........................................................ NTC XF526 Insert Card Module Type: .................................. Analog input No. of Inputs:.................................. 8 Type of Inputs:................................ 0 to 10 volts ........................................................ 0 to 20 mA or 4 to 20 mA ........................................................ NTC ........................................................ PT100, 1000, 3000, Balco Analog Output XF522 Insert Card Module Type: .................................. Analog output No. of Outputs: ............................... 8 Type of Outputs: ............................. 0 to 10 volts +/- mA each Manual Override Switches: ........................................ 5 No. of LEDs:.................................... 8 XF527 Insert Card Module Type: .................................. Analog output No. of Outputs: ............................... 8 Type of Outputs .............................. 0 to 10 volts +/- mA each Manual Override Switches: ........................................ 0 No. of LEDs:.................................... 8 Digital Input XF523 Insert Card Module Type: .................................. Digital input No. of Inputs:.................................. 12 No. of LEDs:.................................... 12 Inputs 1 and 2: ............................... Digital input or fast totalizer Inputs 3-12: .................................... Digital input or slow totalizer Digital Output XF524 Insert Card Module Type: .................................. Digital output No. of Outputs: ............................... 6 Type of Outputs: ............................. 5 change over contacts ........................................................ 1normally open contact Manual Override Switches: ........................................ 5 No. of LEDs:.................................... 6 XF529 Insert Card Module Type: .................................. Digital output No. of Outputs: ............................... 6 Type of Outputs: ............................. 5 change over contacts ........................................................ 1 normally open contact Manual Override Switches: ........................................ 0 No. of LEDs:.................................... 6 Three Position Output XF525 Insert Card Module Type: .................................. Three position output No. of Outputs: ............................... 3 Type of Outputs: ............................. Floating control Manual Override Switches: ........................................ 3 No. of LEDs:.................................... 3 pairs of 2 Power Module XF502 Power Module Module Type: .................................. Power supply Input: .............................................. 24Vac + 10%/-15% Output:............................................ Class 2, 24Vac Switches: ........................................ 1 No. of LEDs:.................................... 3
Smart Excel 500 Controller
LON
NexSentry Star II Controller Innovative Access Control System
Model Type • Excel 50 UPC – without operator interface; Excel 50 UMMIPC-with operator interface
Excel 500 Controller
Smart I/O Module
Same Power of the Excel 500 • Similar operator interface • Same software • Same bus configuration • Fully programmable using Excel CARE
RS-232
• A family of distributed control products that are open and easy to use, the EXCEL 5000 OPEN System is a proven performer that defines versatility • Every control device in the EXCEL 5000 OPEN System family uses LonWorks®based open communications protocol – the worldwide standard in building control – so you can expect smooth, efficient interoperability between devices • Third-party LonMark device support allows additional devices from multiple manufacturers to be added to the existing LON bus • Stand-alone operation at the field control bus level for maximum performance and reliability • Free topology transceiver technology simplifies wiring, uses standard network tools • True Integration with fire, security, and digital video systems creates application opportunities never before available
LON
PRODUCT FEATURES
74-3029 Specification Data I/O Point Capacity Analog Inputs: 8 ............................. 0 to 10 Vdc ........................................................ 0 to 20 mA ........................................................ (w 499 Ω resistor) ........................................................ NTC 20k ohm Analog Outputs: 4 ........................... 0 to 10 Vdc Digital Inputs: 4 .............................. 3 of 4 fast totalizer Digital Outputs: 6............................ Triac 800 mA (all 6 Triacs max 2.4A)
74-3966 Specification Data • TCP/IP network capable • Offers wide range of network connectivity options • Online system diagnostic support • Using the XLS-NCM interface, up to 100 XLS-NCA/XLS140 nodes can be connected to the EBI through a single FNA Interface • UL864 (UOJZ) listed for full control of the XLS140 subsystem
Intelliguard 9000™ Security and Intrusion Detection
*Please contact your Honeywell sales representative for information on the Tema product line.
P/N 92410000020 • Controller mounted Ethernet LAN module • 128 – 256 bit AES-certified encryption
Ethernet
Excel 50 Controller
74-3444 Specification Data • One XLS LAN Interface serves entire XLS200/1000 subsystem: - XLS system point display and command from any EBI workstation - Up to 40,000 points available from 64 XLS nodes - XLS points served via XLS high-speed peer network Meets requirements of UL864 UOJZ for fire alarm control unit and UL1076 for security applications. • 24 Vdc power supplied directly from XLS1000 • Redundant version with Ethernet Link Protector for Class A/Style 6 LAN connections
74-3487 Specification Data 74-3646 Specification Data • Configurable for single or dual Ethernet networks • Converts Ethernet to RS232/RS485 with optical isolation for UL Fire/Security applications • Supports 128-bit AES encryption
TCP/IP Network Adapter
74-3487 Specification Data • Ethernet to RS232 or RS485 Converter, DB25 connecting via DB25 serial • 128 – 256 bit AES NIST certified encryption
EXCEL 5000 ® OPEN™ System Architecture: Designed for unmatched DDC control versatility and true open system flexibility.
Excel Life Safety System (XLS) – Fire Network Adapter (FNA)– Q7055A1031
Network Device Server – 14006700 Series
Wiegand
If LON: See i.LON® 600
Excel Life Safety System (XLS) – LAN Interface 32004871-005 (single), 32004871-002 (dual)
Ethernet
Redundant Ethernet Network (optional)
• Provides network connectivity between Ethernet LAN and LONTalk (FTT-10A) bus
74-3445 Specification Data • TCP/IP capable, offers a wide range of network connectivity options and online system diagnostic support
ON
i.LON® 600 Router
Building network adapter (BNA) Q7055A
Ethernet
Primary Ethernet Network
If C-Bus:
Ethernet
Redundant LAN (optional)
m m
W
M
m
W m
Energy Applications
Asset Tracking
Yes
H
w
D
N
m
H
w
O
N
m
m
m
M
D
D
Au oma on and Con ro So u ons Honeywe 1985 Doug a D ve No h Go den Va ey MN 55422
77 2148
04 04
Honeywe L m ed Honeywe L m ée 35 Dynam c D ve Sca bo ough On a o M1V 4Z9 P n ed n he USA on ecyc ed pape con a n ng 10% pos consume was e