Preview only show first 10 pages with watermark. For full document please download

8-channel Wall-mount Controller

   EMBED


Share

Transcript

LC-8 8-CHANNEL WALL-MOUNT CONTROLLER Accepts Up to Eight 4-20 mA Inputs From Remote Sensor/Transmitters The LC-8 controller is designed for monitoring remote 4-20 mA gas sensor/transmitters or similar devices. This instrument can be connected to any combination of up to eight sensor/transmitters for monitoring oxygen, toxic or combustible gases. The system provides 24 VDC power, audio/visual alarms, relays and other features. SPECIFICATIONS FEATURES Display: ■ Digital Display of All Channels Simultaneously 128 x 128 graphic display simultaneously showing readings for each channel and sensor type. 2.25 x 2.25 inches (57 x 57 mm) Inputs, up to eight: 4-20 mA, 2-wire, 3-wire or 4-wire (consult factory); 24 VDC provided ■ User-Programmable Alarms and Relays ■ 4-20 mA Input, up to 8 Alarm Levels: 2 user-programmable alarms per channel, and 1 common alarm 3 Audio Alarm: An Audible Alarm is provided by a horn mounted within the enclosure. This provides a local audible tone during alarm conditions. Visual Indicator: Red Alarm LED Yellow Fault Alarm LED Green Power On LED Relays: 2 per channel (1st & 2nd alarms). 1 system 3rd gas alarm. 1 system fault relay. ■ Provides 24 VDC Power for Sensor/ Transmitters Relay Rating: 5 Amps, 240 VAC or 24 VDC ■ 4-20 mA Output per Channel Outputs: 4-20 mA per channel ■ Designed for 24 VDC Battery Backup ■ 2 Alarm Relays per Channel, plus 1 Common Alarm Relay and 1 Fault Relay ■ Audio/Visual Alarms ■ 100-240 VAC, 24 VDC Power Options Temperature Range: 14° to 122°F (-10°C to +50°C) Power: 100-240 VAC or 24 VDC ■ Lockable Painted Steel Enclosure Enclosure: Lockable, wall-mount steel enclosure, powder coated to RAL7035, IP65 ingress rating ■ IP65 Ingress Rating Ingress Rating: IP65 Size: Weight: 11.8 H x 19.7 W x 3.2 D inches (300 x 500 x 80 mm) ■ Simple Wall-Mount Installation 17 lbs. (7.7 kg) P.O. Box 979, Ann Arbor, MI 48106-0979 734-761-1270 FAX: 734-761-3220 www.enmet.com [email protected] LC-8 8-Channel Wall Mount Controller CUSTOMER FIELD CONNECTIONS OVERALL ENCLOSURE dimensions ” 3.2 m) m (80 19 .7” (50 0m 4-20 mA Sensor/ Transmitter Input, CH-5 4-20 mA Analog Output, CH-5 2 3 4 5 6 7 8 Alarm 1, CH-5 Relay Contact Alarm 2, CH-5 Relay Contact EXAMPLE CH-5 CONNECTIONS 11.8” (300 mm) 1 m) 100-240 VAC Mains Power 24 VDC Battery Backup Fault Relay Contact Alarm 3 Common Relay Contact SYSTEM CONNECTIONS FRONT PANEL Display Power On/Off LED Alarms 1, 2 & 3 LED NOTE: Loss of primary power renders continuous gas monitors inoperative. Contact factory for specifications and pricing for backup battery systems compatible with ENMET monitors. Fault LED Main Select Switch Horn Defect Switch Menu Option / Change Switch EXAMPLES OF OPTIONAL SENSOR/TRANSMITTERS ORDERING INFORMATION Instrument LC-8, 8-CHANNEL CONTROLLER LC-8 MANUAL P.O. Box 979, Ann Arbor, MI 48106-0979 Part No. 02626-108 80003-049 734-761-1270 • MOS Sensor ppm Hydrocarbons • IR Sensor ppm to % Volume CO2 • Electrochemical Sensor O2, ppm H2 and Toxic Gases • PID Sensor ppm/ppb Toxic Hydrocarbons • IR & Catalytic Sensors for % LEL & % by Volume Combustible Gases FAX: 734-761-3220 www.enmet.com [email protected] Specifications subject to change without notice 11/9/11