Preview only show first 10 pages with watermark. For full document please download

802.3bz Use Cases

   EMBED


Share

Transcript

802.3bz Use Cases Chris DiMinico MC Communications/PHY-SI LLC/Panduit [email protected] 1 802.3bz – March 2016 Background 2 802.3bz – March 2016 Background •Use cases defined to develop deployment configurations and characterize noise environment. •Deployment configurations needed to develop link segment characteristics (ALSNR). 3 802.3bz – March 2016 Deployment configurations • • Define a 2.5 Gb/s PHY for operation over , 1 ‒ Up to at least 100m on four-pair Class D (Cat5e) balanced copper cabling on defined use cases and deployment configurations Define a 5 Gb/s PHY for operation over ‒ Up to at least 100m on Class E (Cat6) balanced copper cabling on defined (2) use cases and deployment configurations ‒ Up to 100m on Class D (Cat5e) balanced copper cabling on defined use cases and deployment configurations 1) Use cases and deployment configurations for 2.5 Gb/s PHY for operation over ‒ Up to at least 100m on four-pair Class D (Cat5e) balanced copper cabling 2) Use cases and deployment configurations for a 5 Gb/s PHY for operation over ‒ Up to at least 100m on Class E (Cat6) balanced copper cabling 3) Use cases and deployment configurations for a 5 Gb/s PHY for operation over ‒ Up to 100m on Class D (Cat5e) balanced copper cabling • Use case based deployment configurations not required for PHYs demonstrating operation over “worse case” cabling configurations. 4 802.3bz – March 2016 IEEE 802.3 Twisted-Pair Link Segment Twisted-pairs MDI MDI wall outlet BASE-T transition or consolidation point cross-connect BASE-T Twisted-pair Link Segment 10BASE-T/100BASE-T/1000BASE-T/10GBASE-T Equipment cord Horizontal Cable MDI MDI Connecting hardware 25/40GBASE-T 5 Twisted-pair Link Segment Up to at least 30 m 802.3bz – March 2016 25/40GBASE-T TIA/TSB-162-A – Cabling Guidelines WAPs WAP TO Lmax = 13 m (42 ft) TO R = 13 m (42 ft) X = 18.3 m (60 ft) Hmax = 80 m (262 ft) TR TO TO Max. 6 m (20 ft) equipment cord Active equipment WAP cell 6 802.3bz – March 2016 Tests Performed @ Dell Austin • Cat5e – 2 and 3 connector topologies – 6x1 bundled cable • All combinations of line rates – Intel Test Suite • Cabling tests (internals, ANEXT, AFEXT) • Cat6 – 2 and 3 connector topologies – 6x1 bundled cable • All combinations of line rates – Intel Test Suite • Cabling tests (internals, ANEXT, AFEXT) • Contributors – Jon Lewis – Dell (sponsored) – Pete Cibula – Intel (to provide update with more details) – Paul Wachtel – Panduit – Mike Klempa – UNH-IOL 802.3bz – March 2016 Test Summary 3-Connector 2.5G/2.5G – Intel Tests Sweeps 2m 3m 90m 5m bundled cable tie wraps every 8” Near End Far End 2-Connector 5m 90m 5m bundled cable tie wraps every 8” tie wraps 802.3bz – March 2016 Test Summary 3-Connector 5G/5G – Intel Test Sweeps 2m-UB 3m 30m-UB/60m-B 5m-UB bundled cable tie wraps every 8” Near End Far End 2-Connector 5m-UB 30m-UB/60m-B bundled cable tie wraps every 8” UB = unbundled B = bundled 802.3bz – March 2016 5m-UB Use Cases Supported Cabinets Unbundled 30 m cable Bundled 60 m cable 2 m unbundled 3 m bundled 802.3bz – March 2016 Use Cases Supported Cabinets Unbundled 30 m cable Bundled 60 m cable 5 m unbundled 802.3bz – March 2016 ALSNR Target zimmerman_3bzah_01a_0815.pdf 12 802.3bz – March 2016 ALSNR – 2.5G disturbed/ 2.5G disturbing 13 802.3bz – March 2016 ALSNR – 2.5G disturbed/ 2.5G disturbing 14 802.3bz – March 2016 ALSNR – 5G disturbed/ 5G disturbing 5G(Victim) / 5G(Agg) Min ALSNR (Cat5e 2 Connector Channel) 34 Test Case 1 2 3 33 32 Category Victim Speed Agg Speed Bundled PL ALSNR 12 ALSNR 36 ALSNR 45 ALSNR 78 Cat5e 5G 5G 90 24.84 26.48 28.56 24.53 Cat5e 5G 5G 60 26.43 28.55 27.84 26.28 Cat5e 5G 5G 60 (*) 27.74 30.50 30.81 27.34 31 * (Near End patch cable unbundled) ALSNR (dB) 30 29 28 27 26 Failing Test Case 5G Victim Passing Test Case 5G Victim 25 24 23 22 5 802.3bz – March 2016 4 3 2 1 0 Test Case 15 ALSNR – 5G disturbed/ 5G disturbing 16 802.3bz – March 2016