802.3bz Use Cases
Chris DiMinico MC Communications/PHY-SI LLC/Panduit
[email protected]
1
802.3bz – March 2016
Background
2
802.3bz – March 2016
Background •Use cases defined to develop deployment configurations and characterize noise environment. •Deployment configurations needed to develop link segment characteristics (ALSNR).
3
802.3bz – March 2016
Deployment configurations •
•
Define a 2.5 Gb/s PHY for operation over , 1 ‒ Up to at least 100m on four-pair Class D (Cat5e) balanced copper cabling on defined use cases and deployment configurations Define a 5 Gb/s PHY for operation over ‒ Up to at least 100m on Class E (Cat6) balanced copper cabling on defined (2) use cases and deployment configurations ‒ Up to 100m on Class D (Cat5e) balanced copper cabling on defined use cases and deployment configurations
1) Use cases and deployment configurations for 2.5 Gb/s PHY for operation over ‒ Up to at least 100m on four-pair Class D (Cat5e) balanced copper cabling 2) Use cases and deployment configurations for a 5 Gb/s PHY for operation over ‒ Up to at least 100m on Class E (Cat6) balanced copper cabling 3) Use cases and deployment configurations for a 5 Gb/s PHY for operation over ‒ Up to 100m on Class D (Cat5e) balanced copper cabling •
Use case based deployment configurations not required for PHYs demonstrating operation over “worse case” cabling configurations. 4
802.3bz – March 2016
IEEE 802.3 Twisted-Pair Link Segment Twisted-pairs
MDI
MDI wall outlet
BASE-T
transition or consolidation point
cross-connect
BASE-T
Twisted-pair Link Segment
10BASE-T/100BASE-T/1000BASE-T/10GBASE-T Equipment cord Horizontal Cable MDI
MDI Connecting hardware
25/40GBASE-T
5
Twisted-pair Link Segment Up to at least 30 m
802.3bz – March 2016
25/40GBASE-T
TIA/TSB-162-A – Cabling Guidelines WAPs
WAP
TO
Lmax = 13 m (42 ft)
TO
R = 13 m (42 ft) X = 18.3 m (60 ft)
Hmax = 80 m (262 ft) TR TO
TO Max. 6 m (20 ft) equipment cord
Active equipment
WAP cell 6
802.3bz – March 2016
Tests Performed @ Dell Austin • Cat5e – 2 and 3 connector topologies – 6x1 bundled cable • All combinations of line rates – Intel Test Suite • Cabling tests (internals, ANEXT, AFEXT) • Cat6 – 2 and 3 connector topologies – 6x1 bundled cable • All combinations of line rates – Intel Test Suite • Cabling tests (internals, ANEXT, AFEXT) • Contributors – Jon Lewis – Dell (sponsored) – Pete Cibula – Intel (to provide update with more details) – Paul Wachtel – Panduit – Mike Klempa – UNH-IOL 802.3bz – March 2016
Test Summary 3-Connector 2.5G/2.5G – Intel Tests Sweeps
2m
3m
90m
5m
bundled cable tie wraps every 8” Near End
Far End
2-Connector 5m
90m
5m
bundled cable tie wraps every 8”
tie wraps
802.3bz – March 2016
Test Summary 3-Connector 5G/5G – Intel Test Sweeps
2m-UB
3m
30m-UB/60m-B
5m-UB
bundled cable tie wraps every 8” Near End
Far End
2-Connector 5m-UB
30m-UB/60m-B
bundled cable tie wraps every 8” UB = unbundled B = bundled
802.3bz – March 2016
5m-UB
Use Cases Supported Cabinets Unbundled 30 m cable Bundled 60 m cable
2 m unbundled
3 m bundled
802.3bz – March 2016
Use Cases Supported Cabinets Unbundled 30 m cable Bundled 60 m cable 5 m unbundled
802.3bz – March 2016
ALSNR Target
zimmerman_3bzah_01a_0815.pdf 12
802.3bz – March 2016
ALSNR – 2.5G disturbed/ 2.5G disturbing
13
802.3bz – March 2016
ALSNR – 2.5G disturbed/ 2.5G disturbing
14
802.3bz – March 2016
ALSNR – 5G disturbed/ 5G disturbing 5G(Victim) / 5G(Agg) Min ALSNR (Cat5e 2 Connector Channel) 34 Test Case 1 2 3
33 32
Category Victim Speed Agg Speed Bundled PL ALSNR 12 ALSNR 36 ALSNR 45 ALSNR 78 Cat5e 5G 5G 90 24.84 26.48 28.56 24.53 Cat5e 5G 5G 60 26.43 28.55 27.84 26.28 Cat5e 5G 5G 60 (*) 27.74 30.50 30.81 27.34
31
* (Near End patch cable unbundled)
ALSNR (dB)
30 29 28 27 26
Failing Test Case 5G Victim Passing Test Case 5G Victim
25 24 23 22
5
802.3bz – March 2016
4
3
2
1
0
Test Case
15
ALSNR – 5G disturbed/ 5G disturbing
16
802.3bz – March 2016