Preview only show first 10 pages with watermark. For full document please download

81ie0012 2015 319693 38765 9047 Dhm 3 7 Installation De En Fr Nl Pl Sk Ro Ru

   EMBED


Share

Transcript

INSTALLATION ZĤ¼›êЛ|ŒêĒĉ 9.5 Details on energy consumption Manufacturer Load profile Energy efficiency class Annual power consumption Energy conversion efficiency Sound power level Special information on measuring efficiency www.stiebel-eltron.com kWh % dB(A) DHM 3 220813 STIEBEL ELTRON XXS A 477 39 15 None DHM 4 220814 STIEBEL ELTRON XXS A 478 38 15 None DHM 6 185473 STIEBEL ELTRON XXS A 478 38 15 None DHM 7 232789 STIEBEL ELTRON XS A 465 40 15 None DHM | 33 ENGLISH Product data complies with EU regulations relating to the Directive on the ecodesign of energy related products (ErP). INSTALLATION ZĤ¼›êЛ|ŒêĒĉ 9.6 Data table DHM 3 220813 Electrical data Rated voltage V Rated output kW Rated current A MCB/fuse rating A Frequency Hz Phases Specific resistance ρ15 ≥ (at ࢡcold Ω cm ≤25 °C) Specific conductivity ı15 ≤ (at µS/cm ࢡcold ≤25 °C) Specific resistance ρ15 ≥ (at ࢡcold Ω cm >25 °C) Specific conductivity ı15 ≤ (at µS/cm ࢡcold >25 °C) Max. mains impedance at 50 Hz Ω Max. mains impedance at 60 Hz Ω Connections Water connection Application limits Max. permissible pressure MPa Values Max. permissible inlet temperature °C On l/min Pressure drop at flow rate MPa Flow rate for pressure drop l/min 34 | DHM 200 2.7 13.3 16 50/60 220 3.2 14.5 16 50/60 230 3.5 15.2 16 50/60 240 3.8 15.8 16 50/60 1/N/PE 1100 DHM 4 220814 200 3.3 16.7 20 50/60 220 4.0 18.2 20 50/60 230 4.4 19.1 20 50/60 240 4.8 20 20 50/60 1/N/PE 1100 DHM 6 185473 200 4.3 21.6 25 50/60 220 5.2 23.6 25 50/60 230 5.7 24.7 25 50/60 240 6.2 25.8 32 50/60 1/N/PE 1100 DHM 7 232789 380 5.9 15.5 16 50/60 400 415 6.5 7.0 16.3 16.9 20 20 50/60 50 2/PE 1100 909 909 909 909 1100 1100 1100 1100 909 909 909 909 0.434 0.424 0.394 0.386 0.377 0.369 0.361 0.354 G 3/8 A G 3/8 A G 3/8 A G 3/8 A 1 1 1 1 35 > 1.6 0.05 1.6 35 > 2.0 0.06 2.0 35 > 2.6 0.08 2.6 35 > 2.6 0.08 2.6 www.stiebel-eltron.com Flow rate limit at DHW delivery Δࢡ on delivery Hydraulic data Nominal capacity Versions Undersink installation Open vented type Sealed unvented type IP rating Safety category Insulating block Heating system Cover and back panel Colour Dimensions Height Width Depth Weights Weight www.stiebel-eltron.com l/min l/min K DHM 3 2.2 2.0 25 DHM 4 2.8 2.5 25 DHM 6 4.3 3.2 25 DHM 7 4.3 3.7 25 l 0.1 0.1 0.1 0.1 X X X IP25 1 Plastic Bare wire Plastic white X X X IP25 1 Plastic Bare wire Plastic white X X X IP25 1 Plastic Bare wire Plastic white X X X IP25 1 Plastic Bare wire Plastic white mm mm mm 143 190 82 143 190 82 143 190 82 143 190 82 kg 1.4 1.4 1.4 1.4 DHM | 35 ENGLISH INSTALLATION ZĤ¼›êЛ|ŒêĒĉ