Preview only show first 10 pages with watermark. For full document please download

9000-066-f-1-13 Quickstart 11x17

   EMBED


Share

Transcript

QUICKSTART “BASIC” GUIDELINES FOR MODEL 9000 - FRONT INSTALLATION MOUNTED ON A CONCRETE PAD “FULL OPEN” 7 e ir W 3- Ra Note: Partial Open Feature is optional and not used for a fully opening gate, see manual for more information. 5 4 dio Re cei Chain Adjustment 6 9 8 * ver 0 Ch Loc # ain kP Par tial late Bra cke t SW ng eni Op ction e Dir 1 Op en C 8 Adjust the chain nuts to tighten the chain. The chain should sag no more than one (1) inch per 10 feet of chain travel. Do not over tighten the chain. DIP-Switches CO it m Li e ar Sp it m Li C VA 24 or ot M N t eu l ra 3 D or ot M 2 1 M 7 6 5 4 r Idleeel h W A B D ON itc Sw N O in ition. pos E AT ly ER on OP use TO an SH nici PU tech Ma t Cenition s o P Reset nu al Re SW 2 1. Opening Direction (See Illustration) 2. OFF 3. ON Auto-Close Timer 4. ON TIME 5. OFF DELAY 6. OFF E 7. OFF 8. OFF 1. OFF 2. OFF 3. ON 4. OFF se 1 23 Adjust 1 to 23 sec. (See reverse side for more information). 1 ng eni n Op ectio Dir it du n co ch in s. 4- p 3/ ee se sw U ith w p Loonduit o C Co n MU crete ST pa be d lev el! r we Po it C A ndu Co Two 115 VAC Convenience Outlets For access control and safety device AC power. um im und. l n S i m ro 2” 4”ove g ”x 8 / . 3 d) is ng ab 4) e ( plie pad uildi Us t sup e t re al b (No onc d loc ded). c the an en of tions omm h t i c dep cond te re d l e n i r u o c gro by s con ow ined rced l e B rm nfo i e det es (re d co eev Co nc ret Pae d rs cho n eA Copyright 2013 DoorKing, Inc. All rights reserved. 4” minimum space between the gate and operator chassis. 4” GATE OPERATOR MUST BE PROPERLY GROUNDED!! Tip: It is recommended that a surge suppressor be installed on the input high voltage power line. A Chassis Ground 115 VAC Note: “Optional” High Voltage Kit black and white wires connect the same as shown. See High Voltage Kit instruction sheet for more information. Input Power Line: White - Neutral Black - 115 VAC Hot Green - Chassis Ground Loop Detectors B Not included - Refer to the Installation/Owner’s manual for more information about DoorKing’s Plug-In loop detectors. DoorKing highly recommends that loops and loop detectors are installed with this slide gate operator. DoorKing offers a free “Loop and Loop-Detectors Information Manual” PDF located at DoorKing’s web site for more information. www.dkaccess.com 24” m tto Bo ition s Po High Voltage Connection HIGH VOLTAGE Chain, Conduit Area and Concrete lea Operator Chassis 3.5” Gate 1 2 3 4 5 6 7 8 eel Whition r e Idl Pos Top er h1 r 1 2 3 4 we Po operator until the “DIP-Switches” and the “Limit Switches” have been adjusted. Damage could occur to the gate and operator. SW 1 ON DO NOT power up and cycle the ON E B U.S.A. DANGER Typical Single Operator Settings 1 2 3 4 5 6 7 8 Chain brackets MUST be mounted so the chain remains the same height as it is on the idler wheels! SW Pedestrians must be supplied with a separate access opening. For complete safety, installation and adjustment of operator instructions, please refer to the Series 9000 Installation/Owner’s manual. 120 Glasgow Avenue Inglewood, California 90301 Hot 1 2 3 1 2 3 4 5 6 7 8 Adjust the 2 limit nuts by depressing the lock plate and spin nuts to desired open and closed gate positions. After adjusting, make sure the lock-plate is engaged in the slots on the limit-nuts to prevent them from rotating. Model 9000 is intended for installation only on sliding gates used for vehicles. Neutral ON Adjustment of Limit Switches 1 itch Sw FF in Oition. s po 13.5” Center of concrete pad 4.5” Conduit Area 24” Radio Receiver C Not included - Refer to a specific Radio Receiver Manual (available from www.dkaccess.com) for more information on radio receivers and antenna installation. (See reverse side for wiring) Concrete Pad Operator and chain MUST be parallel to gate! Chain bracket MUST line up with chain idler wheels! 9000-066-F-1-13 QUICKSTART “BASIC” GUIDELINES FOR MODEL 9000 - DIP-SWITCH AND WIRING REFERENCE 120 Glasgow Avenue Inglewood, California 90301 4-Pin Non-Removable Terminal U.S.A. 3-Button Control Station 1 1 2 3 4 5 2 3 4 Magnetic lock OFF Normal Setting. Timer will function normally. ON Opening gate will stop and begin to close as soon as all reversing inputs (Reverse loops, photo sensors) are cleared regardless of the distance the gate has opened. OFF Normal Setting. Magnetic lock is not used. ON Magnetic lock is used and connected to terminals 9 and 12. ON Normal Setting. Switch 3 MUST be turned ON for Model 9000 operator. OFF Normal Setting. Switch 4 MUST be turned OFF for Model 9000 operator. 6 7 8 9 6 7 8 9 Partial Open 24 Volt Com Relay 8 7 6 5 4 3 2 1 TO icia OP n ER use AT E on ly SH hn tec PU #5 Terminal Note: Any opening device connected to terminal #5 will open the gate to the partial open setting. Secondary entrapment protection devices will also open the gate to the partial open setting. If the inherent reverse sensor gets activated during the close cycle, it will always fully open the gate. #4 Normally Open #6 Normally Open 10 NO 11 11 12 Com 12 NC 13 16 17 18 19 20 Com 13 14 15 16 17 18 19 20 Safety Opening Device SW 1 Switch 3 Must be ON. “Closing-Direction” Photo Sensors SW 1, switch 5: After photo sensor beam gets obstructed: OFF- Reverses gate. ON - Stops gate then continues closing when gate #9 Normally Close is clear (Same function as UL 325 terminal #2). SW 1 Note: The ON setting is used to help prevent tailgating but the photo sensor should be wired to the UL 325 terminal #2 when the “stop gate” function is desired, see Installation/Owner’s manual for more information. 10 4405-010 Quick-Close Timer Override #2 Normally Open Full Open Alarm Telephone Entry Stand-Alone Key Switch Magnetic Lock Alarm Reset 24 Volt 1 amp max. Power (24-Volt DC) and logic output. Power is shut off .5 sec. prior to gate starting and remains off while gate is opening and in the open position. White Red Blue ON 1 2 3 4 SW 2 1 1 2 2 3 3 Full Open 4 4 5 15 Description tor Com 14 Setting Mo To #4 Com Changes direction operator will cycle open upon initial AC power up and open command. Normal Setting. Relay activates when gate is at open limit. Relay activates when gate is not closed. Relay activates when gate is opening and open. Relay activates during opening and closing cycle. wer Po Power is limited to 250 mamps. To #3 Stop N.C. SW 2 DIP-Switches Function 3-Pin Remote Terminal Com N.O. Lock Disengaged Note: After a DIP-switch setting is changed, power must be turned OFF and then turned back on for the new setting to take affect. Switch N.C. 3 ON 8-OFF 8-ON 8-OFF 8-ON ST 2 1 2 3 4 5 6 7 8 7-OFF 7-OFF 7-ON 7-ON 1 Operator Stopped OP #4 Com OFF Normal Setting. Switch must be OFF for single operator. ON Switch must be ON when primary/secondary (dual) gates are used. Single Operator Dual Operators Relay #3 Stop N.C. Mo tor Neu tral Stops Gate Place jumper on bottom 2 pins when using 4-pin terminal. SE CLO Com N.O. Lock Engaged 24V AC Auto-Close Timer 5 7 and 8 Changes direction operator will cycle open upon initial AC power up and open command. OFF The output wired to terminal #4 becomes the output from the exit loop detector plugged into the EXIT Loop port. ON Normal Setting. Terminal #4 is a normal full open input. OFF Auto-close timer is OFF. Manual input required to close gate. ON Normal Setting. Auto-close timer is ON. Adjustable from 1-23 seconds. OFF Normal Setting. Input to terminal #6 and reverse loop will reverse gate during close cycle. ON Input to terminal #6 and/or reverse loop will stop gate during close cycle – gate will continue to close after input to terminal #6 and/or reverse loop are cleared (Helps prevent tailgating). Reverses Gate 6 Opening direction using OFF setting. #2 Close N.O. N.C. it 4 Opening direction using ON setting. Opening direction using OFF setting. EN OP ON 3 Exit Loop Port Output Full Open Input Opening direction using ON setting. #1 Open N.O. 1 2 3 4 5 6 7 8 2 Secondary Operator Opening Direction Description Lim 1 Primary Operator Opening Direction Setting re Function 3-Wire Radio Receiver Normally Closed Interlock Switch Operator Cycling Spa ON 1 2 3 4 5 6 7 8 SW 1 Switch 3-Pin With Jumper Note: When using 3-button control station AND interlock switch together, #3 terminal (N.C.) must be wired in series. it SW 1 DIP-Switches Use a standard 4-wire 3-button control station. DoorKing’s 3-wire 3-button control station cannot be used. Lim For safety and installation instructions, please refer to the Installation/Owner’s manual. M Pedestrians must be supplied with a separate access opening. Important: Controls must be far enough from the gate so that the user is prevented from coming in contact with the gate while operating the controls. Outdoor or easily accessible controls should have a security feature to prevent unauthorized use. CO Model 9000 is intended for installation only on slide gates used for vehicles. Stand-Alone Keypad Stand-Alone Card Reader Remote Alarm Reset Station (DKS P/N 1404-080) MUST be mounted in the line-of-sight of the gate operator. Note: All stand-alone and telephone entry devices must use a separate power source.