Preview only show first 10 pages with watermark. For full document please download

93ps Runtime Calculator_v2

   EMBED


Share

Transcript

Runtime Charts For Eaton 93PS 8-40kW UPS 93PS UPS on‐battery runtimes with different load ratings Content Internal batteries for 8‐20kVA ‐ Small Frame 2 5-year internal battery (9Ah) 10-year internal battery (7Ah) 2 2 Internal batteries for 8‐40kVA ‐ Large Frame 3 5-year internal battery (9Ah) 10-year internal battery (7Ah) 3 4 External batteries ‐ Small battery cabinet 5 5-year battery (9Ah) in Small Battery Cabinet 10-year battery (7Ah) in Small Battery Cabinet 5 5 External batteries ‐ Large battery cabinet 6 10-year battery (CSB HRL12200W) in Large Battery Cabinet 6 External batteries with internal batteries ‐ Small Frame 7 9Ah 5-year internal and external battery 7 External batteries with internal batteries ‐ Large Frame 8 CSB HRL12200W with 9Ah 5-year battery CSB HRL12200W with 7Ah 10-year battery 8 Page 1 of 8 Runtime Charts For Eaton 93PS 8-40kW UPS Internal batteries for 8‐20kVA ‐ Small Frame 5‐year internal battery (9Ah) Internal battery back‐up table for UPS ratings 8‐20 kVA (small frame), p.f. 0.8: Battery 9Ah 12V 9Ah 12V Qty 1x32 2x32 8kVA 14 33 10kVA 10 25 15kVA ‐ 15 20kVA ‐ 10 min min Internal battery back‐up table for UPS ratings 8‐20 kVA (small frame), p.f. 0.9: Battery 9Ah 12V 9Ah 12V Qty 1x32 2x32 8kVA 12 28 10kVA 8 22 15kVA ‐ 13 20kVA ‐ 8 min min Internal battery back‐up table for UPS ratings 8‐20 kVA (small frame), p.f. 1.0: Battery 9Ah 12V 9Ah 12V Qty 1x32 2x32 8kVA 10 25 10kVA 7 19 15kVA ‐ 11 20kVA ‐ 7 min min 10‐year internal battery (7Ah) Internal battery back‐up table for UPS ratings 8‐20 kVA (small frame), p.f. 0.8: Battery 7Ah 12V 7Ah 12V Qty 1x32 2x32 8kVA 10 30 10kVA 7 22 15kVA ‐ 12 20kVA ‐ 7 min min Internal battery back‐up table for UPS ratings 8‐20 kVA (small frame), p.f. 0.9: Battery 7Ah 12V 7Ah 12V Qty 1x32 2x32 8kVA 9 26 10kVA 5 18 15kVA ‐ 9 20kVA ‐ 5 min min Internal battery back‐up table for UPS ratings 8‐20 kVA (small frame), p.f. 1.0: Battery 7Ah 12V 7Ah 12V Qty 1x32 2x32 8kVA 7 22 10kVA ‐ 15 15kVA ‐ 8 20kVA ‐ ‐ min min Note! The specifications are subject to change without a notice. The battery backup tables are given with end voltage 1.70 VPC and temperature +25°C. The batteries are fully charged and measured after min. (5) full discharge cycles. Page 2 of 8 Runtime Charts For Eaton 93PS 8-40kW UPS Internal batteries for 8‐40kVA ‐ Large Frame 5‐year internal battery (9Ah) Internal battery back‐up table for UPS ratings 8‐40 kVA (large frame), p.f. 0.8: Battery 9Ah 12V 9Ah 12V 9Ah 12V 9Ah 12V Qty 1x32 2x32 3x32 4x32 8kVA 14 33 55 77 10kVA 10 25 42 59 15kVA ‐ 15 25 36 20kVA ‐ 10 17 25 30kVA ‐ ‐ 10 15 40kVA ‐ ‐ 6 10 min min min min 30kVA ‐ ‐ 8 13 40kVA ‐ ‐ ‐ 8 min min min min 30kVA ‐ ‐ 7 11 40kVA ‐ ‐ ‐ 7 min min min min Internal battery back‐up table for UPS ratings 8‐40 kVA (large frame), p.f. 0.9: Battery 9Ah 12V 9Ah 12V 9Ah 12V 9Ah 12V Qty 1x32 2x32 3x32 4x32 8kVA 12 28 47 68 10kVA 8 22 36 51 15kVA ‐ 13 22 30 20kVA ‐ 8 15 22 Internal battery back‐up table for UPS ratings 8‐40 kVA (large frame), p.f. 1.0: Battery 9Ah 12V 9Ah 12V 9Ah 12V 9Ah 12V Qty 1x32 2x32 3x32 4x32 8kVA 10 25 42 59 10kVA 7 19 31 44 15kVA ‐ 11 19 27 20kVA ‐ 7 13 19 Note! The specifications are subject to change without a notice. The battery backup tables are given with end voltage 1.70 VPC and temperature +25°C. The batteries are fully charged and measured after min. (5) full discharge cycles. Page 3 of 8 Runtime Charts For Eaton 93PS 8-40kW UPS 10‐year internal battery (7Ah) Internal battery back‐up table for UPS ratings 8‐40 kVA (large frame), p.f. 0.8: Battery 7Ah 12V 7Ah 12V 7Ah 12V 7Ah 12V Qty 1x32 2x32 3x32 4x32 8kVA 10 30 49 70 10kVA 7 22 38 53 15kVA ‐ 12 22 33 20kVA ‐ 7 14 22 30kVA ‐ ‐ 7 12 40kVA ‐ ‐ ‐ 7 min min min min 30kVA ‐ ‐ 5 9 40kVA ‐ ‐ ‐ 5 min min min min 30kVA ‐ ‐ ‐ 8 40kVA ‐ ‐ ‐ ‐ min min min min Internal battery back‐up table for UPS ratings 8‐40 kVA (large frame), p.f. 0.9: Battery 7Ah 12V 7Ah 12V 7Ah 12V 7Ah 12V Qty 1x32 2x32 3x32 4x32 8kVA 9 26 43 60 10kVA 5 18 33 45 15kVA ‐ 9 18 28 20kVA ‐ 5 12 18 Internal battery back‐up table for UPS ratings 8‐40 kVA (large frame), p.f. 1.0: Battery 7Ah 12V 7Ah 12V 7Ah 12V 7Ah 12V Qty 1x32 2x32 3x32 4x32 8kVA 7 22 38 53 10kVA ‐ 15 28 41 15kVA ‐ 8 15 24 20kVA ‐ ‐ 10 15 Note! The specifications are subject to change without a notice. The battery backup tables are given with end voltage 1.70 VPC and temperature +25°C. The batteries are fully charged and measured after min. (5) full discharge cycles. Page 4 of 8 Runtime Charts For Eaton 93PS 8-40kW UPS External batteries ‐ Small battery cabinet 5‐year battery (9Ah) in Small Battery Cabinet External battery back‐up table for UPS ratings 8‐40 kVA, p.f. 0.8: Battery 9Ah 12V 9Ah 12V Qty 2x32 3x32 8kVA 33 55 10kVA 25 42 15kVA 15 25 20kVA 10 17 30kVA ‐ 10 40kVA ‐ 6 min min 20kVA 8 15 30kVA ‐ 8 40kVA ‐ ‐ min min 20kVA 7 13 30kVA ‐ 7 40kVA ‐ ‐ min min 20kVA 7 14 30kVA ‐ 7 40kVA ‐ ‐ min min 20kVA 5 12 30kVA ‐ 5 40kVA ‐ ‐ min min 20kVA ‐ 10 30kVA ‐ ‐ 40kVA ‐ ‐ min min External battery back‐up table for UPS ratings 8‐40 kVA, p.f. 0.9: Battery 9Ah 12V 9Ah 12V Qty 2x32 3x32 8kVA 28 47 10kVA 22 36 15kVA 13 22 External battery back‐up table for UPS ratings 8‐40 kVA, p.f. 1.0: Battery 9Ah 12V 9Ah 12V Qty 2x32 3x32 8kVA 25 42 10kVA 19 31 15kVA 11 19 10‐year battery (7Ah) in Small Battery Cabinet External battery back‐up table for UPS ratings 8‐40 kVA, p.f. 0.8: Battery 7Ah 12V 7Ah 12V Qty 2x32 3x32 8kVA 30 49 10kVA 22 38 15kVA 12 22 External battery back‐up table for UPS ratings 8‐40 kVA, p.f. 0.9: Battery 7Ah 12V 7Ah 12V Qty 2x32 3x32 8kVA 26 43 10kVA 18 33 15kVA 9 18 External battery back‐up table for UPS ratings 8‐40 kVA, p.f. 1.0: Battery 7Ah 12V 7Ah 12V Qty 2x32 3x32 8kVA 22 38 10kVA 15 28 15kVA 8 15 Note! The specifications are subject to change without a notice. The battery backup tables are given with end voltage 1.70 VPC and temperature +25°C. The batteries are fully charged and measured after min. (5) full discharge cycles. Page 5 of 8 Runtime Charts For Eaton 93PS 8-40kW UPS External batteries ‐ Large battery cabinet 10‐year battery (CSB HRL12200W) in Large Battery Cabinet External battery back‐up table for UPS ratings 8‐40 kVA, p.f. 0.8: Battery 200W 12V Qty 1x32 8kVA 126 10kVA 107 15kVA 72 20kVA 48 30kVA 29 40kVA 19 min 20kVA 42 30kVA 25 40kVA 17 min 20kVA 37 30kVA 21 40kVA 14 min External battery back‐up table for UPS ratings 8‐40 kVA, p.f. 0.9: Battery 200W 12V Qty 1x32 8kVA 114 10kVA 97 15kVA 60 External battery back‐up table for UPS ratings 8‐40 kVA, p.f. 1.0: Battery 200W 12V Qty 1x32 8kVA 107 10kVA 88 15kVA 52 Note! The specifications are subject to change without a notice. The battery backup tables are given with end voltage 1.70 VPC and temperature +25°C. The batteries are fully charged and measured after min. (5) full discharge cycles. Page 6 of 8 Runtime Charts For Eaton 93PS 8-40kW UPS External batteries with internal batteries ‐ Small Frame 9Ah 5‐year internal and external battery External battery and 2 internal strings back‐up table for UPS ratings 8‐40 kVA, p.f. 0.8: Internal battery Battery Qty 9Ah 12V 2x32 9Ah 12V 2x32 External battery Battery Qty 9Ah 12V 2x32 9Ah 12V 3x32 8kVA 77 94 10kVA 59 77 15kVA 36 47 20kVA 25 32 min min 20kVA 22 28 min min 20kVA 19 25 min min 20kVA 22 30 min min 20kVA 18 26 min min 20kVA 15 22 min min External battery and 2 internal strings back‐up table for UPS ratings 8‐40 kVA, p.f. 0.9: Internal battery Battery Qty 9Ah 12V 2x32 9Ah 12V 2x32 External battery Battery Qty 9Ah 12V 2x32 9Ah 12V 3x32 8kVA 67 84 10kVA 51 67 15kVA 30 41 External battery and 2 internal strings back‐up table for UPS ratings 8‐40 kVA, p.f. 1.0: Internal battery Battery Qty 9Ah 12V 2x32 9Ah 12V 2x32 External battery Battery Qty 9Ah 12V 2x32 9Ah 12V 3x32 8kVA 59 77 10kVA 44 59 15kVA 27 36 7Ah 10‐year internal and external battery External battery and 2 internal strings back‐up table for UPS ratings 8‐40 kVA, p.f. 0.8: Internal battery Battery Qty 7Ah 12V 2x32 7Ah 12V 2x32 External battery Battery Qty 7Ah 12V 2x32 7Ah 12V 3x32 8kVA 70 86 10kVA 53 70 15kVA 33 43 External battery and 2 internal strings back‐up table for UPS ratings 8‐40 kVA, p.f. 0.9: Internal battery Battery Qty 7Ah 12V 2x32 7Ah 12V 2x32 External battery Battery Qty 7Ah 12V 2x32 7Ah 12V 3x32 8kVA 60 78 10kVA 45 60 15kVA 28 38 External battery and 2 internal strings back‐up table for UPS ratings 8‐40 kVA, p.f. 1.0: Internal battery Battery Qty 7Ah 12V 2x32 7Ah 12V 2x32 External battery Battery Qty 7Ah 12V 2x32 7Ah 12V 3x32 8kVA 53 70 10kVA 41 53 15kVA 24 33 Note! The specifications are subject to change without a notice. The battery backup tables are given with end voltage 1.70 VPC and temperature +25°C. The batteries are fully charged and measured after min. (5) full discharge cycles. Page 7 of 8 Runtime Charts For Eaton 93PS 8-40kW UPS External batteries with internal batteries ‐ Large Frame CSB HRL12200W with 9Ah 5‐year battery External battery and 4 internal strings back‐up table for UPS ratings 8‐40 kVA, p.f. 0.8: Internal battery Battery Qty 9Ah 12V 4x32 External battery Battery Qty 200W 12V 1x32 8kVA 235 10kVA 185 15kVA 115 20kVA 86 30kVA 53 40kVA 36 min 20kVA 76 30kVA 45 40kVA 30 min 20kVA 66 30kVA 40 40kVA 27 min 20kVA 83 30kVA 51 40kVA 35 min 20kVA 73 30kVA 43 40kVA 29 min 20kVA 63 30kVA 38 40kVA 26 min External battery and 4 internal strings back‐up table for UPS ratings 8‐40 kVA, p.f. 0.9: Internal battery Battery Qty 9Ah 12V 4x32 External battery Battery Qty 200W 12V 1x32 8kVA 210 10kVA 165 15kVA 103 External battery and 4 internal strings back‐up table for UPS ratings 8‐40 kVA, p.f. 1.0: Internal battery Battery Qty 9Ah 12V 4x32 External battery Battery Qty 200W 12V 1x32 8kVA 185 10kVA 146 15kVA 91 CSB HRL12200W with 7Ah 10‐year battery External battery and 4 internal strings back‐up table for UPS ratings 8‐40 kVA, p.f. 0.8: Internal battery Battery Qty 7Ah 12V 4x32 External battery Battery Qty 200W 12V 1x32 8kVA 229 10kVA 178 15kVA 112 External battery and 4 internal strings back‐up table for UPS ratings 8‐40 kVA, p.f. 0.9: Internal battery Battery Qty 7Ah 12V 4x32 External battery Battery Qty 200W 12V 1x32 8kVA 203 10kVA 159 15kVA 99 External battery and 4 internal strings back‐up table for UPS ratings 8‐40 kVA, p.f. 1.0: Internal battery Battery Qty 7Ah 12V 4x32 External battery Battery Qty 200W 12V 1x32 8kVA 178 10kVA 140 15kVA 88 Note! The specifications are subject to change without a notice. The battery backup tables are given with end voltage 1.70 VPC and temperature +25°C. The batteries are fully charged and measured after min. (5) full discharge cycles. Page 8 of 8