Preview only show first 10 pages with watermark. For full document please download

94725id-1 Libro Tecnico Ads V09_06 Secccion I.pmd - Guard

   EMBED


Share

Transcript

ADS ADS ADS ADS TECHNICAL TECHNICAL BOOK BOOK SECTION I - SYSTEM DESCRIPTION ADS ADS ADS TECHNICAL BOOK The technical book is amde of three sections: - Section I: ADS System Description - Section II: Instalation Diagrams - Section III: Extensions (Cod. 94725Id-1) (Cod. 94725Id-2) (Cod. 94725Id-3) ADS Technical Book - Section I Code 94725Id-1 V11_06 This technical document is edited by FERMAX ELECTRÓNICA S.A.E. for information purposes, reserving the right to modify technical features of the products cited at any time and with no prior notice. These changes shall be reflected in subsequent editions. Page. 2 ADS ADS INDEX SECTION I - SYSTEM DESCRIPTION ADS SYSTEMS - General Features ................................................................................................................................................... 5 - ADS System Types ................................................................................................................................................ 6 ADS PANELS - ADS City Panels .................................................................................................................................................... 7 - ADS Citymax Panels ............................................................................................................................................. 9 - ADS Direct Panels ............................................................................................................................................... 11 - ADS Digital Panels .............................................................................................................................................. 13 - ADS Bruto Panels ................................................................................................................................................ 15 - ADS Halo Panels ................................................................................................................................................. 16 - ADS Guard Unit ................................................................................................................................................... 18 ADS AMPLIFIERS - General features of ADS amplifiers ....................................................................................................................... 20 - ADS amplifiers version 4 (City, Citymax, Direct and Digital Panels) ...................................................................... 21 - ADS amplifiers version 5 (City, Citymax, Direct and Digital Panels) ...................................................................... 22 - ADS Halo Panel amplifiers ................................................................................................................................... 23 HOME TERMINALS - Loft Monitors ........................................................................................................................................................ 25 - Citymax Monitors ................................................................................................................................................. 27 - Telephones ........................................................................................................................................................... 29 OTHER BASIC COMPONENTS OF AN ADS INSTALLATION - Switchers, Distributors, Electric locks, etc ........................................................................................................... 31 - Power Supplies .................................................................................................................................................... 32 Page. 3 ADS ADS Page. 4 ADS ADS ADS SYSTEM ADS (AUDIO DATA SYSTEM) is a simplified installation electronic entry and video entry system, designed by FERMAX ELECTRONICA, whose main feature consists of not using call wires. Main Features of ADS Systems * Simplified wiring installations - Electronic entry: 3 wires. - Video entry system: 3 wires + coaxial. ADS systems do not require the typical call wire for each telephone or monitor needed in traditional systems. Call from the panel is converted into a digital signal which is sent by a common wire. This digital signal is only recognised by the telephone or monitor that has been programmed to do so, generating the corresponding audible call signal. * Up to 199 homes with electronic entry or video entry system. With ADS systems you can manage buildings of up to 199 homes. * One or two electronic entry or video entry system accesses (entrances). ADS systems let you install up to two entrances on the same building, with the possibility of combining audio and video accesses. In buildings where initially only one access is covered, adding an electronic entry or video entry system in a second access requires a minimum installation. * One Central Guard Unit In addition to the two electronic entry/video entry system accesses, it is possible to install a desktop guard unit that enables home-guard unit, home-outdoor panel and outdoor panel-guard unit communication. * Access Control Accessories Direct and Digital ADS systems incorporate access control functions by means of keypad codes via the numeric keypads on their panels (previously programmed through the keypad). ADS Digital systems can also incorporate backup proximity card readers for access control. * Easy expansion with MDS-ADS system It is possible to create closures for several outside accesses (MDS) to several interior blocks (ADS) easily and quickly. (For further information, please consult the MDS-ADS Wiring Diagrams). * Possibility to connect several equipments sets in each home It is possible to install several monitors and/or telephones in the same home quickly and easily. * Simple expansions A telephone may be connected to any other telephone or monitor in the installation, with only three wires. * Easy start-up Behind the ADS system wiring, a simple programming is carried out to assign a number to each of the telephones or monitors. If a home has more than one telephone and/or monitor, they can be programmed with the same number, so that all of them will ring at once when the home receives a call. * Door Release Timing setting The ADS system lets you set the electric lock timing between 1 and 99 seconds (in panels with keypads). * Privacy (total secrecy) in conversations It is not possible, in any case, for a conversation between the outdoor panel or guard unit to be heard from any other home. This is even valid between terminals installed in the same home. When a telephone or monitor is called, the system function is inhibited for the rest of the terminals (for a minimum time), so that even by pressing the auto-on switch you cannot see the telecamera image or hear the conversation of any other user. * Auto-on All the monitors have an auto-on button you can use to connect with the outdoor panel at any time to see the image captured by the camera and listen to the ambient sound, as long as the system is not being used by any other monitor or telephone (privacy). In this case, when the auto-on button is pressed, a «beep» is heard as confirmation that the channel is engaged. In systems with 2 accesses (2 panels), it is possible to select the panel you want to connect if using a LOFT or CITYMAX monitor (Citymax Export, Extra, or Complet models with extended connector). It is also possible to enable the telephones (Extra or Complet) with an automatic on switch (optional kit). The autoon switch on the telephone will only activate the audio channel when it is not being used by any other terminal. Page. 5 ADS ADS ADS System Types In all ADS systems, each home terminal (telephone/monitor) is programmed with an ADS address that identifies it in the installation and distinguishes it from the rest of the terminals. The ADS addresses go from 1 to 199 (Programming the terminals is explained in the corresponding section for each terminal). ADS systems are divided into three types, depending on the outdoor panel: ADS CITY. Installation with ADS City Panels: Pushbutton panels. In City panels, each button corresponds with a given ADS address, so that the house call is made by pressing the corresponding call button. It is suitable for buildings with few homes, as there is one button for each home and the size of the panels depends on the number. HIGH RESOLUTION CCD CAMERA PAN &TILT ADS DIRECT Installation with ADS Direct Panels: Panels with Keypad. A house call is made by entering the ADS address assigned to each home terminal by means of a numeric keypad, which is also used for access control functions. A Directory Panel installed beside the ADS Panel gives the ADS address corresponding to each home. The size of the ADS DIRECT Panel will always be the same, regardless of the number of homes. 4 7 A 2 5 8 3 6 9 4 7 A 0 2 5 8 3 6 9 0 HIGH RESOLUTION CCD CAMERA PAN &TILT 1 2 3 4 5 6 7 8 9 A 0 B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 13 32 33 34 35 36 37 38 39 40 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 60 ADS DIGITAL Installation with ADS Digital Panels: Panels with Keypad and Display. House calls are made by entering the ADS address assigned to each home terminal by means of a numeric keypad (which also has access control functions), or by a call code (a number, usually the door number) associated by panel programming to an ADS address. ADS Digital Panels have a built-in electronic directory that lets you search for names via an LCD display. In ADS Digital Panels, the display can be connected to a backup proximity card reading module, enhancing the ADS Digital system’s access control functionality. The users and their card codes are stored and managed with the keypad and display. 4 7 A 2 5 8 3 6 9 0 4 7 A 2 5 8 3 HIGH RESOLUTION CCD CAMERA PAN &TILT 6 9 LCD DIGITAL SYSTEM 0 1 4 Page. 6 2 5 3 6 7 8 9 A 0 B ADS ADS ADS City Panels ADS City panels are characterised by having: - ADS amplifier module: Independent module that handles all the functions of the ADS installation (call, two-way communication, door opening, programming ...). - Call buttons: House calls are made by pressing the corresponding call button assigned to the home. HIGH RESOLUTION CCD CAMERA PAN &TILT - Call extension module (one every 16 buttons): The main advantage of an ADS CITY Panel is that it does not use call wires. This is possible since the call is made by transmission of a digital signal, generated via the Call Extension Modules (see section on «Call Extension Module»). This module is not necessary if the panel has 1 to 3 pushbuttons. - Telecamera module (b/w or colour) (only required for video entry installations) or viewer module (optional). - Door Release Time Setting: With a keypad it is possible to program the electric lock/door release timing between 1 and 99 seconds (See ADS Direct Panels section). ADS City Panel Typology ADS CITY look the same as FERMAX CITY series panels (conventional 4+N system), which are divided into 9 series, all of the same width, but of different heights: SERIES 1 128 x 130 SERIES 2 151 x 130 SERIES 3 SERIES 4 SERIES 5 SERIES 7 SERIES 8 SERIES 9 SERIES 6 175 x 130 199 x 130 246 x 130 341 x 130 389 x 130 436,5 x 130 294 x 130 In each Series, there are several panel models, depending on whether they incorporate an ADS amplifier, viewer to fit the telecamera, number of buttons, etc. The only difference between CITY 4+N panels and CITY ADS panels is that the electronics of the amplifiers incorporated are different, so, in order to distinguish the ADS amplifier from panels with the CITY 4+N amplifier, a 5 has been added to the reference of the panel with the ADS amplifier. (Example: The panel shown in the figure from Series 6 in 4+N has Ref.: 8562; in ADS, its reference will be 85625). CITY let you make different types of combinations (with single or double pushbutton, with viewer, without amplifier, with telecamera ...). In each case, you can select the most suitable one for the features of the installation (number of homes, electronic entry or video entry, etc.): Panel with amplifier, viewer and double pushbuttons. Panel without amplifier and with single pushbuttons. Panel 1 with amplifier, Panel 2 with telecamera Double pushbuttons. Panel 1 with double pushbuttons, Panel 2 with telecamera, amplifier and double pushbuttons. Page. 7 ADS ADS Call Extension Module The main advantage of an ADS panel is that it uses no call wires. This is possible because the call is made by transmitting a digital code, generated by the amplifier, when a given call button is pressed. This code is sent through data line «L» which, being a common wire, reaches all the monitors or telephones. Only the terminal that has been programmed previously with this code will recognise it, then generate a call signal. Obviously, after start-up, the monitors or telephones will have to be programmed with their corresponding call codes. This is done very easily, as shown in the files for each monitor and telephone. In City pushbutton panels, to generate the specific code for each of the calls, one or more Call Extension Modules are used (one for each16 buttons). This module translates each press of a button on the panel into an ADS call code. (See Call Extension Module connection diagrams). City panels with 1 to 3 pushbuttons do not require installation of the call extension module (see Panel pre-wiring diagrams). Call Extension Module Connection in ADS City Panels EXT. PLACA TELEFONO MODULO EXTENSION 16 LLAMADAS REF.2441 16 CALL EXTENSION PACK 1 2 3 4 5 6 78 INT. JP2 Ct L S B B +12 C No Nc - + 9 10 11 12 13 14 15 16 CONECTAR AL COMUN DE PULSADORES 7 8 5 6 3 4 1 2 ADS CITY Audio Panel If a larger number of pushbuttons are needed, two or more modules may be used, up to the total 199 homes admitted by the ADS system. REF.2441 PACK EXTENSION 16 LLAMADAS 16 EXTENSION CALL PACK LLAMADAS / CALLS SIGUIENTE/NEXT ANTERIOR/PREVIOUS 1234 56 78 9 10 11 12 13 14 15 16 REF.2441 PACK EXTENSION 16 LLAMADAS 16 EXTENSION CALL PACK LLAMADAS / CALLS SIGUIENTE/NEXT ANTERIOR/PREVIOUS 1234 56 78 9 10 11 12 13 14 15 16 To ADS amplifier Pushbuttons up to nº 16 Page. 8 Pushbuttons from nº 17 on ADS ADS ADS Citymax Panels ADS Citymax panels are characterised by having: - ADS amplifier module: Independent module that handles all the ADS installation functions (call, two-way communication, door opening, programming ...). - Pushbutton modules: With these modules, the call extension module is not necessary. The pushbutton modules generate the ADS call code. Call modules are available with 1 to 6 pushbuttons. House calls are made by pressing the corresponding call button assigned to each home. - Telecamera module (b/w or colour) (only needed for video entry installations) or viewer module (optional). - Door Release Time Setting: With a keypad, it is possible to program the electric lock/door release timing between 1 and 99 seconds (See ADS Direct Panels section). ADS Citymax Panel Typology ADS CITYMAX panels make up the FERMAX line of continuous profile modular composition panels. Their design and features are similar to CityLine panels, with the differences in practical aspects that affect their composition and assembly. Panel assembly is very simple. All you have to do is select the combination of modules and fit them into the frames. All the accessories are compatible. Citymax Panels Necessary for insertion of the amplifier, telecamera and pushbutton modules. The four panel models coincide with series 3, 5, 7 and 8 of the CityLine panels. Camera module ADS Citymax Amplifier Module Includes cable for connection to the first pushbutton module. Pushbutton modules With these modules, the call extension module is not necessary, which considerably reduces the cost of installation. It is provided with an interconnection cable to the next module. ADS panel connection cable Necessary to interconnect several panels. Connected between the output of the last module of the first panel and the first one of the next panel. Page. 9 ADS ADS Citymax Pushbutton Module Interconnection As mentioned previously, Citymax panels do not require call extension modules, as the function generating the ADS call code is incorporated in the pushbutton modules corresponding to each home (do not confuse the ADS call code or ADS call address with the house door number). The different pushbutton modules are interconected to make up the desired panel configuration: A B C D JP2 5 EXT. PLAC TELEFONO IDIOMA LANGUAGE INT. Ct L S B B +12 C No Nc - + Pushbutton modules (single and/or double) To next pushbutton modules ADS Addresses As for the ADS addresses generated by the Citymax pushbutton modules, each pushbutton has one assigned in the factory. ADS addresses assigned in factory to each button 1 1 2 2 3 4 3 5 6 When several pushbutton modules are installed, the ADS addresses look like this: Example 1 Example 2 1 2 1 3 4 2 5 6 ADS addresses used: 1, 2, 3, 4, 5, 6, 7 and 8 ADS addresses used: 1, 2, 4, 5, 6, 7, 8 and 9 7 4 5 8 6 7 8 9 ADS address «3» is not used. This is because the electronics incorporated in the simple pushbutton modules is the same for the 3-button module 3 as for the 1-button module. The same goes for the double pushbutton modules, the modules with 2 to 6 buttons incorporate the same electronics as the 6-button modules. Page. 10 ADS ADS ADS Direct Panels ADS Direct panels are characterised by having: - ADS amplifier module: Independent module that handles all the functions of the ADS installation (call, two-way communication, door opening, programming ...). - Numeric keypad: The keypad generates the ADS call code and no call extension module is needed. House calls are made by entering the corresponding code assigned to the home. HIGH RESOLUTION CCD CAMERA PAN &TILT 1 2 3 4 5 6 7 8 9 A 0 B - Access control: ADS Direct systems access include control functions, via the numeric keypad, by means of keypad codes (previously programmed via the keypad). - Viewer to install the telecamera module (b/w or colour) in vido entry systems or fit a panoramic card slot in electronic entry installations. - Door Release Time Setting between 1 and 99 seconds. ADS Direct Panel Typology The size of ADS DIRECT panels is always the same (with one viewer: Series 5 or with 2 viewers: Series 7) regardless of the number of homes. ADS AMPLIFIER ADS AMPLIFIER TELECAMERA PANORAMIC CARD SLOT HIGH RESOLUTION CCD CAMERA PAN &TILT 1 2 3 4 5 6 7 8 9 A 0 B AX RM FE KEYPAD MODULE ADS DIRECT VIDEO Panel Series 5 1 2 3 4 5 6 7 8 9 A 0 FE RM AX KEYPAD MODULE ADS DIRECT AUDIO Panel Series 5 Along with the ADS DIRECT panel, a DIRECTORY PANEL is installed (from the same series), in order to note the name corresponding to each of the home codes: HIGH RESOLUTION CCD CAMERA PAN &TILT 1 2 3 4 5 6 7 8 9 A 0 B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 13 32 33 34 35 36 37 38 39 40 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 60 DIRECTORY PANEL This DIRECTORY PANEL includes illumination lights, which must be connected to the ADS amplifier. (See panel internal wiring diagrams). Page. 11 ADS ADS Door Release Code Programming in ADS Direct Panels All the ADS Direct Panel models let you open the door from the outdoor panel by keying in a 4-digit code. Take the following steps to activate and configure the code operated door release: * Door release code activation sequence 1.- With the power supply disconnected, make a short circuit between terminals B and B on the amplifier (or press the door release button, if it is installed). 2.- Maintaining the short circuit, connect the system power supply (as it is not necessary to keep the short circuit or the button pressed). You have one minute to enable the door release code, as described in the following point. 3.- Key in programming code 3 1 4 1 (this code cannot be changed) and enter the four figures of the code you want to use to open the door, followed by the  key. * Code change To change the door release code, you must know the previous one. If you do not know the previous door release code, you will need to go through the sequence described in the previous section. The code change sequence is as follows: 1.- Key in programming code: 3 1 4 1. 2.- Enter the current door release code. 3.- Enter the new code (four digits) and press the  key. NOTES: - Use the ‘A’ key to delete or restart the sequence. - Do not forget to undo the short circuit between B and B in the panel amplifier after performing the necessary operations. - Once the door release code is activated, this function cannot be disabled. This means that there will always be a door release code, whether known by the system users or not. Open Door Timing Programming in ADS Direct Panels All the ADS Direct Panel models let you program the door release activation timing. * There are two programmable timings: - Timing for opening the door from the home and from the panel keypad (using the door release code). - Opening timing corresponding to the button located inside the facility and that serves to activate the door release (if installed). * The programming sequence is as follows: 1.- Disconnect the power supply and switch it on again. You have approximately one minute to perform the following steps of the sequence. 2.- Key in programming code 3 1 4 1 followed by 4 digits and press the  key. Of these 4 figures, the first two correspond to the opening time from the home, and the last two with the opening time from the button installed in the entrance. NOTES: - Possible timing values are between 01 and 99 seconds. - Any time below 10 seconds must be preceded by the digit ‘0’. - In the event of error when programming the timings (or if you want to make any changes), it is necessary to reinitiate the sequence from point 1. Page. 12 ADS ADS ADS Digital Panels ADS Digital are charcterised by having: - ADS amplifier module: Independent amplifier module that handles all the functions of the ADS installation (call, two-way communication, door opening, programming...). - Display LCD: ADS Digital Panels incorporate an electronic directory that lets you search for the names (home owners...) through an LCD display. Programming the different system parameters is done through the keypad and display. HIGH RESOLUTION CCD CAMERA PAN &TILT LCD DIGITAL SYSTEM 1 2 3 4 5 6 7 8 9 A 0 B - Numeric keypad: The keypad generates the ADS call code and no call extension module is needed. House calls are made by entering the corresponding code assigned to the home. - Access control: As well as including access control functions via the numeric keypad by means of keypad codes, ADS Digital systems let you connect a secondary proximity card reader module to the digital panel display. The users and their card or keypad codes are stored and managed by means of the keypad and display. - Viewer to install a telecamera module (b/w or colour) in video entry systems or fit a panoramic card slot in electronic entry installations. - Door Release Time Setting between 1 and 99 seconds. ADS Digital Panel Typology The size of the ADS DIGITAL panels is always the same (Series 5 or 7) independently of the number of homes. ADS AMPLIFIER TELECAMERA ADS AMPLIFIER HIGH RESOLUTION CCD CAMERA PAN &TILT LCD DIGITAL SYSTEM 1 2 3 4 5 6 7 8 9 A 0 B AX RM FE DISPLAY MODULE AUDIO DATA SYSTEM 22 D1D + + - AX RM FE 6 B AX RM FE KEYPAD MODULE DISPLAY MODULE 1 2 3 4 5 6 7 8 9 A 0 B AX RM FE KEYPAD MODULE - + - + ADS DIGITAL VIDEO Panel Series 7 ADS DIGITAL AUDIO Panel Series 5 Along with the ADS DIGITAL panel, a DIRECTORY PANEL can be installed (from the same series) in order to note the name corresponding to each of the house codes. This Directory Panel is optional, as its function is carried out by the DIRECTORY PANEL The Directory Panel includes illumination lights that must be connected to the ADS amplifier. (See panel internal wiring diagrams). HIGH RESOLUTION CCD CAMERA PAN &TILT LCD DIGITAL SYSTEM 1 2 4 5 7 8 3 9 A 0 B 6 Page. 13 ADS ADS Configuring Parameters in ADS Digital Panels ADS Digital Panels have added functionalities, programmed via the keypad and display: - Electronic Directory: Lets you enter data on up to 350 users (residents) (although always to a maximum of 199 homes). In this way, it is possible to authorise several users for the same home. This function lets the visitor view the data on the residents authorised in the directory, simplifying the search process (using the arrows) and call (once the person has been found) by pressing the  key. - Personalised Opening Codes: Lets you assign each user their own keypad code, proximity card or button key (these two latter options if there is a secondary proximity reader Ref. 23352 or button key Ref. 23362) to access the premises. - 4-digit Call Coding: Using the digital directory, it is also possible to encode the calls with 4 digits (0001...9999) in such a way that you can, for example, make 2-2 combinations (2 digits for the floor and 2 for the apartment), and so avoid restricting possibilities to the ADS range (from 1 to 199). - Programming and Configuring Opening Times. Below is a quick guide to programming the basic parameters of ADS Digital Panels (for more information on programming, see «ADS Panels with Keypad Administrator Manual» code 94451). Programming user data 1.- Enter programming............................................................................................. + AB21AB + 24797 0 2.-User Menu......................................................................................................... M 1 2 3 4 p Us Pa Ut Ti 3.-Add users.......................................................................................................... U 1 s + 2 - 3 4 M T *Name: 16 characters. Shown on the first line of the display. If ‘*’ is entered, this information is not shown. Name Mary Peters *Line 2: 16 characters. Shown on the second line of the display and used to enter more than one user per home or to indicate the type of business premises. Dentist *Line 2?: Press ‘A’ to let the information entered appear in the field corresponding to Line 2. Press ‘B’ to show the call code only (‘DOOR: xxxx’). *ADS Line: line number the call is made to when the call code is entered, or when a screen search is made and ’’ is pressed. As with the other ADS systems, the line number must be a value from 001 to 199 and must have been programmed previously in the telephone/monitor. Press ‘A’ to rectify. Validate by pressing ‘B’. *Opening Code: If from a keypad, we always enter the 6 digits. If less are used, the first 4 or 5 will be used, discarding those to the right. Press ‘A’ to rectify. Validate by pressing ‘B’. 5 6 7 R C O 1 Line 2 Line 2? *Call: Code from 0001 to 9999 that the visitor has to key in to call this user. CANNOT be repeated. Press ‘A’ to rectify. Validate by pressing ‘B’. 1 (A=Yes) Call 0012 ADS Line 012 Opening Code 123456 Opening Code 123456 N0001 Programming Open Door Timing in ADS Digital Panels 1.- Enter programming .................................................................................................. 2.- Open Door Time Programming Menu .......................................................................... 3.-Opening Time from Home (tA) ................................................................................ Door release activation time when the door is opened from the home terminal: telephone or monitor. A value between 1 and 99 seconds must be set. Press ‘B’ to validate. 4.-Open Door Time from Panel ..................................................................................... This parameter sets the time the electric lock is activated when the door release button on the panel is pressed or a valid user code is entered: by keypad, button key or proximity card. Value must be set between 1 and 99 seconds. Press ‘B’ to validate. 5.-Desconnect and reconnect the power supply. Page. 14 0 + AB21AB + 24797 M 1 2 3 4 p Us Pa Ut Ti 4 Time A (1-99) 04 B Time B (1-99) 04 B ADS ADS «BRUTO» ADS Anti-vandal Panels ADS BRUTO panels make up the FERMAX anti-vandal outdoor panel line. This continuous profile, modular composition panel integrates the finest qualities: resistence, security and appearance. The line consists of 3 series of panels in 2, 3 and 4 modules. In addition to the basic modules: amplifier, camera and pushbuttons, the panel may incorporate the following modules: Memokey, Private Reader, cover without pushbuttons and Panoramic Card Slot, all in BRUTO format. 1 2 3 A 4 5 6 0 7 8 9 B The operation and configuration of each ADS BRUTO model (City, Direct and Digital) is the same as explained for ADS City panels. ADS BRUTO Panel Typology ADS City BRUTO panels are characterised by having: - ADS amplifier module: Independent module that handles all the functions of the ADS installation (call, two-way communication, door opening, programming ...). - Call pushbuttons: House calls are made by pressing the corresponding call button assigned to the home. - Call extension module (one every 16 buttons): The main advantage of an ADS CITY Panel is that it does not use call wires. This is possible because the call is made by transmission of a digital signal, generated by the Call Extension Modules (see section on «Call Extension Module»). - Telecamera module (b/w or colour) (only required for video entry installations) or viewer module (optional). ADS Direct BRUTO panels are characterised by having: - ADS amplifier module: Independent module that handles all the functions of the ADS installation (call, two-way communication, door opening, programming ...). 1 2 3 A 4 5 6 0 7 8 9 1 2 3 A 4 5 6 0 7 8 9 B - Numeric keypad: The keypad generates the ADS call code, so call extension modules are not required. House calls are made by entering the corresponding code assigned to the home. - Telecamera module (b/w or colour) (only required for video entry installations) or viewer module (optional). ADS Digital BRUTO panels are characterised by having: - ADS amplifier module: Independent module that handles all the functions of the ADS installation (call, two-way communication, door opening, programming ...). - Display LCD: ADS Digital panels incorporate an electronic directory that lets you look for the names (home owners...) on an LCD display. The different system parameters are programmed via the keypad and display. 1 2 3 A 1 2 3 A 4 5 6 0 4 5 6 0 7 8 9 B 7 8 9 B - Numeric keypad: The keypad generates the ADS call code, so call extension modules are not required. House calls are made by entering the corresponding code assigned to the home. - Telecamera module (b/w or colour) (only required for video entry installations) or viewer module (optional). Page. 15 ADS ADS HALO ADS Panels Halo ADS panels are characterised by having: - ADS amplifier module: Module built into the panel that handles all the functions of the ADS installation (call, two-way communication, door opening, programming ...). 27 ºC 10:54 - LCD Screen (128x128 pixels): Halo ADS panels have a built-in electronic directory that lets you search for names (home owners...) via an LCD display. The different system parameters are programmed via the keypad and screen. - Numeric keypad (in panels for buildings): The keypad generates the ADS call code, so call extension modules are not required. House calls are made by entering the corresponding code assigned to the home. To make a call in Halo Kit panels, simply press the house call button (represented by a bell icon). TOP PERFORMANCE PANEL ACCESS CONTROL SYSTEM - Access Control: Halo ADS panels incorporate a proximity card reader concealed behind the screen, able to control up to 350 cards. They also include, via the numeric keypad, access control by means of keypad codes. Users and their card or keypad codes are stored and managed by means of the keypad and screen (the maximum number of proximity cards + keypad codes is 350). - Colour Camera with built-in illumination. - Temperature Sensor: The Halo panel LCD screen shows the temperature registered by the sensor. - Door Release Timer Programming between 1 and 99 seconds. ADS Digital Panel Typology Halo ADS building panel: Speaker Camera lighting on/off switch Colour camera Potentiometers LCD contrast setting 27 ºC 10:54 Balance: Coupling setting LCD display Home-Panel audio setting (128x128 pixels) TOP PERFORMANCE PANEL ACCESS CONTROL SYSTEM Electronic Directory pushbuttons... Call button Key in buttons Microphone Halo ADS building panel Series 7 FF Page. 16 Panel-Home audio setting Date and time Temperature Pan & Tilt (horizontal-vertical 10º) ADS ADS Halo ADS Kit Panel: Camer lighting on/off switch Speaker Colour camera PC OFF ON Potentiometers RES LCD contrast control 27 ºC 10:54 Panel-Home audio control Date and time Temperature Balance: Coupling control Display LCD Home-panel audio control (128x128 pixels) Pan & Tilt (horizontal-vertical 10º) Multi-function buttons TOP PERFORMANCE PANEL ACCESS CONTROL SYSTEM Call button Microphone Halo ADS building panel Serie 5 Parameter Configuration Configuring the different Halo panel parameters is easy to do using their excellent graphic interface and by means of the keypad (building panel) and/or multi-function buttons (kit panel). All the information on the parameters to be programmed is shown on the LCD screen, as well as information on the communication status between visitor-home-guard unit: Configuration screen (Example: Select Configuration Menu): 27 ºC 10:54 1.Users 2.Configuration 3.Codes 4.Timings 5.Message 6.Utilities 27 ºC 27 ºC 10:54 1.Users 2.Configuration 3.Codes 4.Timings 5.Message 6.Utilities 27 ºC 2.1 2.2 2.3 2.4 2.5 2.6 10:54 Clock Language Panel Num. Panel type Exit button Backlight 10:54 1.Users 2.Configuration 3.Codes 4.Timings 5.Message 6.Utilities System status information screens: TOP PERFORMANCE PANEL ACCESS CONTROL SYSTEM 27 ºC Calling Home ... 10:54 27 ºC 10:54 Conversation 27 ºC 10:54 DOOR OPEN For further information, please consult the Halo ADS Panel technical manuals: - Halo KIT Manual: code 97067 - Halo Building Panel Manual: code 97069 Page. 17 ADS ADS ADS Guard Unit ADS systems can be completed with an ADS GUARD UNIT, desktop or wall mounted (monitor format): Description of Controls Display Provides different information during Guard Unit handling. Call queue control keys Switch between queue of calls from panels and telephones. Cyclic selection of call from the current queue (from panels and telephones). Call (Bell) To call the house telephones. Electric lock Door release action key. Guard Unit-Telephone communication. Selects the GUARD UNIT-TELEPHONE communication channel. Communicates with the last telephone that was called. Main Panel-Telephone communication. Activates the communication channel between the MAIN PANEL and the last TELEPHONE called. Secondary Panel-Telephone communication. Activates the communication channel between the SECONDARY PANEL and the last TELEPHONE called. Guard Unit-Main Panel communication. Activates the communication channel between the GUARD UNIT and the MAIN PANEL. Guard Unit-Secondary Panel communication. Activates the communication channel between the GUARD UNIT and the SECONDARY PANEL. Keypad. Located under the telephone handset. Used to enter the telephone number of the home, panel number and data in general. It also lets you program the house terminals as if from a panel. (See «ADS Guard Unit Manual» Code 97001). Call queue viewing Activation/Deactivation. Used to activate or deactivate the view of the call queues on the guard unit display. Delete/Cancel. Press this key to delete the data entered or to cancel the call currently selected. Call/Set up communication. Press this key to call the house telephones or set up communication with the call selected from the queue. Page. 18 ADS ADS Operating Modes The features of the different operating modes for facilities with a single Guard Unit Centre are: YES NO DAY MODE * The Guard Unit can call and receive calls from the telephones. * The outdoor panels cannot call the telephones directly. * Calls from outdoor panels to the telephones are intercepted by the Guard Unit, which may transfer them to the telephone called, or to any other. YES YES YES AUTOMATIC MODE * The Guard Unit can call and receive calls from the telephones. * The outdoor panels can call the telephones directly. * Calls from the outdoor panels to telephones are monitored in the Guard Unit, where the concierge can answer the calls or not, and transfer them at will to the telephone called, or to any other. YES YES NO YES NIGHT MODE * The Guard Unit does not answer calls from telephones or outdoor panels. It functions as though it were just another outdoor panel. * The outdoor panels can call the telephones directly. NO Operating Mode MODE Selection . 1. Press The display shows a series of dashes: 2. Press the key followed by The display shows the current MODE 3. Use the Press the ______ repeatedly until the dashes are completed: A333_ _ Current Mode Day keys (below the display) to select the MODE desired: Day Auto Night key when the MODE desired appears on the display: Page. 19 ADS ADS ADS Amplifiers All ADS panels include an AMPLIFIER, which handles all the functions of an ADS installation (call, two-way communication, door opening, programming ...). MA IO GE ID UA NG LA HIG H CC RESO D C LU AM TIO ERA N PAN & TI O ST UE MP DEO CO VI O ED VÍDEMPOS Hz CO 50 IR CC p. 75 1 Vp LT A B C D M V MIC L S SP BS Sb Sa 2 +1 NC NA ADS Halo Panel Amplifier ADS City Panel Amplifier The main features of ADS amplifiers are as follows: * Voice Synthesisers Every time the door release is activated from a home, the voice synthesiser issues a message: «Door is open, please close after entering». Every amplifier has a built-in voice synthesiser module, which issues the «Door is open, please close after entering» message each time the door release is activated from indoors. The language of the message is configurable: French, English, Spanish and German, depending on the message selection switch position, or may be cancelled if it is not set in any of the positions. The synthesiser module can be substituted by other versions that include different languages (Valencian, Catalan, Portuguese, Polish, Dutch, Russian ...). For more information, please consult the Technical Information, code 94335b. * Open Door Timing It is possible to program the door release timing between 1 and 99 seconds (in panels with keypad). * For installation with one or two accesses In installations with two accesses, it is necessary to define one of the panels as ACCESS 1 and the other as ACCESS 2, by means of a jumper for this purpose. System programming must always be done from the ACCESS 1 panel, i. e., from the one with the jumper set. See installation diagrams. Switcher is not needed, as long as one of the panels is audio only. * Autoprotection against wiring errors The ADS amplifier has built-in electronic protection circuits against wiring errors in the installation, presenting, in each case, the symptoms explained in the following table: SHORT CIRCUIT between wires: SYMPTOM CAUSED: «+» (positive) and «-» (negative) • Nothing works. • Nothing works when a call is made. • The short circuit activates the power supply protection devices, so there is no tension between «+» and «-». «-» (negative) and «L» (audio-data) • The panel emits constant beeps (acoustic coupling) or a series of short beeps. «+» (positive) and «L» (audio-data) • Although there is 12 Vdc tension between «+» and «-», nothing works. • There is no call, but there is monitoring in the panel. • When the call button is pressed, the Diagnostic LED gives off short flashes. Page. 20 ADS ADS ADS City Panels (Cityline, Citymax, Direct and Digital) Amplifier Here we describe the main features of the ADS amplifiers used in City panels: Version 4 Amplifiers Version 4 amplifiers have currently been replaced by the version 5 amplifiers, being totally compatible with each other. 4 2 3 IDIOMA / LANGUAGE PACK EXTENSION 1 COD.XXXXX PLACA AMPLIFICADOR ADS ADS AMPLIFIER AMPLIFICATEUR ADS ADS VERSTÄRKER 5 JP1 TELEFONO TEST PRGM VOLUMEN 6 ENG. FRA. ESO. DEU. 18 Vdc JP2 X Ct L S B B Ab Ab - + ALIMENTACION POWER SUPPLY - + 18 Vdc X VERSION : 8 4.0 7 1 Call extension, keypad or display module connection. The “Kit amplifier” model lets you connect up to 3 pushbuttons here. 2 JP1: Main/secondary panel selection jumper: Main panel: leave jumper. Secondary panel: remove jumper. 3 JP2: Voice synthesis language selection (only 4 languages available: Spanish, English, French and German). 4 Test LED(diagnostic): If there is a short circuit between “+” and “L”, when a call is made from the outdoor panel, it emits a series of short flashes. 5 Home-Outdoor panel volume control potentiometer. 6 Outdoor panel-Home volume control potentiometer. 7 Amplifier version. 8 Connection terminals: X: Pushbutton and card slot lighting connection. Ct: Telecamera activation (10 Vdc). L: Audio and data bus. S: Video switcher activation signal (gives a negative). B, B: Pushbutton connection to open door from hallway interior. Ab, Ab: Direct Current electric lock connection (12 Vdc, 0.4A) +,-: Power supply 18 Vdc. Technical Features Power supply Consumption Operating temperature Home-Outdoor panel maximum audio volume potential Outdoor panel-Home maximum audio volume potential 18 Vdc in standby audio active 40 mA 250 mA -10 , +60 °C 1W 0,15 W Page. 21 ADS ADS Version 5 Amplifiers Version 5 amplifiers are totally compatible with previous version amplifiers, and can be installed in existing ADS installations. 6 2 COD.XXXXX AMPLIFICADOR ADS ADS AMPLIFIER AMPLIFICATEUR ADS ADS VERSTÄRKER A B C D PLACA 7 TELEFONO 5 8 18 Vdc TEST 4 VOLUMEN IDIOMA LANGUAGE P4 3 JP2 CN2 PACK EXTENSION 1 Ct L S B B +12 C NO NC - + ALIMENTACION POWER SUPPLY - + 18 Vdc VERSION : 5.0 10 9 1 Call extension, keypad or display module connection or up to three pushbuttons, for which there is no longer an amplifier module for buildings, and another for kit (up to 3 lines). 2 CN2: Pushbutton and card slot lighting connection. 3 JP2: Main/secondary panel selection jumper: Main panel: leave jumper. Secondary panel: remove jumper. 4 P4: Call monitoring and voice synthesis volume control potentiometer. 5 Test LED (diagnostic): If there is a short circuit between “+” and “L”, when a call is made from the outdoor panel, it emits a series of short flashes. 6 Voice synthesis language selection. By default, includes Spanish, French, English and German, but there are interchangeable modules (VOX modules) with more languages (check availability). 7 Home-Outdoor panel volume control potentiometer. 8 Outdoor panel-Home volume control potentiometer. 9 Amplifier version 10 Connection terminals: Ct: Telecamera activation (10 Vdc). L: Audio and data bus. S: Video switcher activation signal (gives a negative). B, B: Video switcher activation signal (gives a negative). +12: Auxiliary tension output (12Vdc, 0’4A máx). C, NO, NC: Potential-free electric relay. Lets you activate AC electric lock (if the installation has this source), magnetic seals, signal another device, etc... +,-: Power supply 18 Vdc. Technical Features 18 Vdc Power supply Consumption Operating temperature Home-Outdoor panel maximum audio volume potential Outdoor panel-Home maximum audio volume potential Page. 22 in standby audio active 40 mA 250 mA -10 , +60 °C 1W 0,15 W ADS ADS ADS Halo Panel (Kit and Building) Amplifier Here is a description of the main features of the ADS amplifiers used in Halo panels. The Halo panel and its built-in ADS amplifier make up a single block, unlike the all the City panel versions, being indivisible from the rest of the panel electronics. Halo panel amplifiers are totally compatible with City panel ADS amplifiers, and can be installed in exisiting ADS installations. ALT 2 PC RES OFF ON CAM 1 3 IDIOMA LANGUAGE A B C D 5 4 M V VÍDEO COMPUESTO COMPOSED VIDEO 6 L S CCIR 50 Hz 1 Vpp. 75 MIC SP BS MA IO GE ID UA NG LA A B C D L S SP - 75 18Vdc MIC IN MADE F. SENSOR TEMP. BS Sb Sa 2 +1 NC NA C + SOR SEN RE NC NA C + M V TO PUES O COMD VIDE O VÍDE POSE COM 50 Hz CCIR 1 Vpp. 18 Vdc Sb Sa +12 P TEM SPAIN 0 570 7 T INPU 18 V 1 Pan & Tilt telecamera setting (horizontal-vertical 10º). 2 Connector for Heating Resistance (optional). 3 Camera lighting on/off switch. ON: The camera LEDs are activated when a call is made from the panel or switched on automatically from the home. (Default mode). 4 Control potentiometers: OFF: The LEDs are never activated. LCD Contrast control Home-Outdoor panel Audio control Balance: Coupling control Outdoor panel-Home Audio control 5 Voice synthesis language selection. By default, includes Spanish, French, English and German, but there are interchangeable modules (VOX modules) with more languages (check availability). 6 Connection terminals: V,M: Video terminals (V:Live, M:Mesh). Ct: Telecamera activation (10 Vdc). L: Audio and data bus. S: Video switcher activation signal (gives a negative). BS, -: Video switcher activation signal (gives a negative). SP, -: Open door sensor connection. Sa, Sb: PC and panel cloning connection. +12: Auxiliary tension output (12Vdc, 0’4A máx). NC, NA, C: Potential-free electric relay. Lets you activate AC electric lock (if the installation has this source), magnetic seals, signal another device, etc... +,-: Power supply 18 Vdc. 7 Temperature sensor connector. Page. 23 ADS ADS Technical Features Halo Building Panel Power supply Consumption Halo Kit Panel 18 Vdc in standby + backlight Off with call + backlight On call audio active voice synthesis active illuminated keypad (building panel) Operating temperature Home-Outdoor panel maximum audio volume potential Outdoor panel-Home maximum audio volume potential Real Time Clock (RTC). Stability ± 20 ppm Page. 24 200 mA 370 mA 50 mA (additional) 60 mA (additional) 140 mA (additional) 50 mA (additional) -10 , +60 °C 1W 0,15 W ADS ADS ADS Loft Monitors Controls Description Monitor on LED indicator. Door release button / call guard unit. · When in conversation with the Outdoor Panel, press this button to activate the electric lock. · With the handset hung up, not communicating with the panel, press this button to call the guard unit (if there is one). Autoswitch-on and Main/Secondary Camera selection. F1 and F2: Pushbuttons for additional functions. F On/Off (three positions: Off - On Medium Volume - On High Volume) Brightness Contrast Colour (only in colour monitor) Monitor Installation Assembly Dismantling 1 4 90º 3 0m 1.6 2 Monitor Programming 1 IMPORTANT 2 In installations with 2 accesses, programming can only be done from the panel configured as Main Panel. 2 4 7 3 5 6 8 A 9 0 i In installations with a Guard Unit, in order to be able to program the monitors from the outdoor panel, the guard unit must be in Night Mode. To program from the Guard Unit, it must be set in programming mode (See «ADS Guard Unit Manual» code 97001). < 2 min 1. With the monitor connected, press the programming button. A confirmation tone is heard. 2. Press the house call button or call code (in panels with keypad). A confirmation tone is heard again. * The monitor will not work unless it has been programmed. Page. 25 ADS ADS Loft Monitor Operation Call * When the call button on the Outdoor Panel is presssed, a call tone is heard both at the outdoor panel and the monitor, while the screen and ON-OFF indicator go off. If there is any additional equipment in the home, they will also sound. If the call is not answered, the equipment will be disconnected automatically after 30 seconds. Answer the call * Pick up the telephone handset to set up conversation with the visitor. If there are several sets of equipment in the same home, the first one that is picked up automatically disconnects the rest. Duration of the communication is limited to 90 seconds or until the handset is replaced. Open the door to the visitor * When in communication with the visitor, it is possible to open the door by pressing the Call the Guard Unit * With the monitor in standby (no communication), pressing this button the Guard Unit (if there is one). Manual monitor activation (autoswitch-on) * The monitor can be turned on manually at any time by pressing the key. makes a call to key. The screen stays lit for 30 seconds, after which it goes off automatically. During this time, it is possible to open the door by pressing the key. If the monitor is lit, pick up the telephone handset to talk to the person that is at the Outdoor Panel for 90 seconds, or until the handset is hung up, and open the door to them in the same way as if they had called. Press (for at least 1 second) to switch (alternatively the viewing from the main and secondary camera (if there is one). Press briefly to cut off the communication. Technical Features Power supply Consumption in standby audio + video Operating temperature - Humidity Image tube. B/W: Flat Screen . 4" Diagonal (100 mm) Video signal: Comopound signal 1 Vpp 75 Ω, 7 Mhz. Dimensions (Height x Width x Depth): 221x203x61 (mm) Page. 26 18 Vdc Colour B/W 12 mA 8 mA 650 mA 400 mA [5 , +60 °C] - [0,90%] Colour: TFT4” ADS ADS Citymax ADS Monitors Controls Description Door release button / guard unit call. · When in conversation with the Outdoor Panel, press this button to activate the electric lock. · With the telephone hung up, not in communication with the panel, press this button to call the Guard Unit (if there is one). N TIO OLU ES OR HR NIT HIG MO AT FL 1 Main camera autoswitch-on. 2 Secondary camera autoswitch-on. Colour control (in colour monitor) Stair light relay (in B/W monitor) Pushbuttons for additional functions in EXTRA (2 additional buttons) and COMPLET (5 additional buttons) models. ON/OFF switch - LED monitor on indicator Brightness Contrast Monitor Installation Assembly Dismantling 1 4 3 N TIO LU SO H RE NITOR HIG MO AT FL 1 2 0m 1.6 ION LUT SO H RE NITOR HIG T MO FLA 1 2 90º 2 Monitor Programming 2 1 IMPORTANT 3 In installations with 2 accesses, programming can only be done from the panel configured as Main Panel. In installations with a Guard Unit, to be able to program the monitors from the outdoor panel, the guard unit must be in Night Mode. 2 4 7 3 5 6 8 A 9 0 J1 J1 PRG i < 2 min PRG To program from the Guard Unit, it must be set in programming mode (See «ADS Guard Unit Manual» code 97001). 1. With the monitor connected, set switch J1 to PRG position. A confirmation tone is heard. 2. Press the house call button or call code (in panels with keypad). A confirmation tone is heard again. 3. Set the switch in its original position and fit the Monitor. * The monitor will not work unless it has been programmed. Page. 27 ADS ADS Citymax Monitor Operation Call * When the call button on the Outdoor Panel is pressed, a call tone is heard at the outdoor panel and the monitor, the screen comes on and the ON-OFF indicator goes off. ION LUT SO H RE NITOR HIG T MO FLA 1 If there is any additional equipment in the house, they will also sound. If the call is not answered, the equipment is disconnected automatically after 30 seconds. 2 ION LUT SO H RE NITOR HIG T MO FLA Answer the call * Pick up the telephone handset to begin a conversation with the visitor. If there is more than one set of equipment in the same home, the first one that is picked up automatically disconnects the rest. Duration of the communication is limited to 90 seconds or until the handset is replaced. 1 2 ION LUT SO H RE NITOR HIG T MO FLA Open the door to the visitor * When in communication with the visitor, it is possible to open the door by pressing the key. 1 2 Call the Guard Unit * With the monitor in standby (no communication), pressing this button the Guard Unit (if there is one). makes a call to Manual monitor activation (autoswitch-on) * The monitor can be turned on manually at any time simply by pressing is a secondary panel). ION LUT SO H RE NITOR HIG T MO FLA 1 2 1 or 2 (if there The screen stays lit for 30 seconds, after which it goes off automatically. During this time, it is possible to open the door by pressing the button. If the monitor is lit, pick up the telephone handset to talk to the person that is at the Outdoor Panel for 90 seconds, or until the handset is hung up, and open the door to them in the same way as if they had called. Press (for at least 1 second) to switch (alternatively the viewing from the main and secondary camera (if there is one). Press 1 or 2 briefly to cut off the communication. Technical Features Power supply Consumption in standby audio + video Operating temperature - Humidity Image tube. B/W: Flat Screen . 4" Diagonal (100 mm) Video signal: Compound signal 1 Vpp 75 Ω, 7 Mhz. Dimensions (Height x Width x Depth): 195x211x60 (mm) Page. 28 18 Vdc Colour B/W 15 mA 15 mA 350 mA 350 mA [5 , +60 °C] - [0,90%] Colour: TFT4” ADS ADS ADS Telephone ADS telephones can be installed in facilities with telephones only, mixed installations with telephone and ADS monitors or in installations with ADS monitors (as additional equipment in the home). As with the ADS monitors and the telephones, once installed and connected, require a simple programming before operation. Controls Description Door release button / guard unit call. · When in conversation with the Outdoor Panel, press this button to activate the electric lock. · With the telephone handset hung up, not in communication with the panel, press this button to call the Guard Unit (if there is one). Pushbuttons for additional functions in EXTRA (2 additional buttons) and COMPLET (5 additional buttons) models. Installing the Telephone 1 2 3 RE F.*** 4 * 616E 616E 61 6E For convenience, we recommend programming the telephone before closing. ADS Telephone Programming Programming ADS telephones is very simple, similar to ADS monitors. Before programming ADS telephones, they must be connected to the installation and power supply. Among the ADS telephone models, there are two programming modes: - ADS telephones with «Programming Button» - ADS telephones with «Programming Jumper» The programming button or jumper is in the telephone circuit (to access the circuit, it is necessary to remove the telephone cover). ADS telephones (except the Kit telephone) have a call tone selector jumper that lets you choose between two different call tones. The steps to program the different telephone models and call tone configuration are explained below: IMPORTANT In installations with 2 accesses, programming can only be done from the panel configured as Main Panel. In installations with a Guard Unit, to be able to program the monitors from the outdoor panel, the guard unit must be in Night Mode. To program from the Guard Unit, it must be set in programming mode (See «ADS Guard Unit Manual» code 97001). Page. 29 ADS ADS Programming ADS Telephones with «Programming Button» Programming button 1 R *** EF. 2 Call tone selection jumper * HIGH CC RESO D CA LU ME TION PAN RA & TILT 1 2 4 7 3 5 6 8 A 9 0 i < 2 min 1. With the telephone connected, press the programming button. A confirmation tone is heard. 2. Press the house call button or key in the call code (in panels with keypad). The confirmation tone is heard again. * The telephone will not work until it has been programmed. Programming ADS Telephones with «Programming Jumper» 1 N 2 PG 3 N ** F.** RE PG ** F.** RE 2 4 7 3 5 6 8 A 9 0 Programming Jumper i < 2 min ADS KIT Telephone 1 N PG 2 3 N PG 2 4 7 3 5 6 8 A 9 0 Programming Jumper i < 2 min 1. With the telephone connected, set the J1 switch in the PRG position. If you keep the hang up button pressed, a confirmation tone can be heard. 2. Press the house call button or key in the call code (in panels with keypad). The confirmation tone is heard again. 3. Place the switch in its original position and close the telephone. * The telephone will not work unless it has been programmed.. Page. 30 ADS ADS OTHER BASIC Components of ADS Installations ADS Switcher In installations with two video entry accesses, the use of an ADS switcher ref. 2450 is required. It is not necessary in installations where either of the two installations is audio only. PACK CAMBIADOR VIDEO ADS REF.2450 ADS VIDEO SWITCHER PACK Its purpose is to select the video signal from the panel where the call has been made from. This selection is made by a signal (a negative) sent by the panel through the «S» wire (see installation diagrams). S VIDEO PLACA PANEL VIDEO V S+ L VM VIDEO EXTERIOR EXTERNAL VIDEO Vi SALIDA VIDEO VIDEO OUTPUT Vo + L Vi Mi + L VoMo Video Distributor All the video signal bifurcations must be made with the corresponding video distributors. There are two models: Ref. 2448. 2-output distributor Ref. 2449. 4-output distributor The distributors have a built-in 75 ohm charge resistance, which will only need to be cut when output number 1 is being used, i. e., it will be cut in all the distributors in cascade, except for the last one in the trunk. REF.2448 DISTRIBUIDOR VIDEO 2 SALIDAS 2 OUTPUTS VIDEO DISTRIBUTOR + 1 5 (-) 2 6 V M V M +18 4 3 V M V M R1 75 Electric Lock/Door Release As of version 5.0, ADS amplifiers have a potential-free relay (C, No, Nc) that enable it to be used either as AC or DC electric lock. The electric lock power supply 12 Vdc can go through the ADS amplifier itself (until a maximum electric lock consumption of 0.4A). If using an alternate current electric lock, it will be necessary to add an additional AC power supply (sufficiently dimensioned), which, through the amplifier relay, will provide the current needed to activate the electric lock. ADS Telephone Interface The telephone interface lets you divert the call from the entry system to a programmed exterior telephone (landline or mobile), letting you attend visitors and open the door from a remote spot, or simulate presence when you are away. USE PRG PWR INTERFACE TELEFONICO ADS ADS TELEPHONIC INTERFACE MADE IN SPAIN REF. XXXX D NC C NO LN LN TF TF - VEASE LAS INSTRUCCIONES DE INSTALACIÓN ANTES DE CONECTAR A LA ALIMENTACIÓN. INPUT + -D FORWARD Installed in the home and connected to the entry/video entry system and the telephone network, enables communication with the outdoor panel and lets you open the door from any conventional telephone, fixed or cordless, in the home. - SEE INSTALLATION INSTRUCTIONS - 18 V, 500 mA BEFORE CONNECTION TO THE SUPPLY. 12 V, 700 mA, 50-60 Hz 12 V, 500 mA + L - AUDIO ADJUST Aerial Camera Lets you expand the possibilities of an ADS installation with one video entry access with several aerial cameras, which can be viewed from the monitor of the home where they are installed (consult installation diagrams in the corresponding manuals). This application is useful for surveillance of the rear of the home in villas, to monitor the access door from a vantage point, giving a perfect view of the person accessing the villa from an additional angle to that of the camera located at the outdoor panel, to check the garage ... etc. The aerial camera is manufactured in zamak and 2.5 mm thick,impact -resistant polycarbonate glass. Its special chassis, forming a 90º angle, and its reversible wall support, let you anchor it to all types of ceiling, walls, corner units, at a 45º angle ... etc Page. 31 ADS ADS Power Supplies The proper functioning of any electrical/electronic system depends, to a great extent, on a good dimensioning of the power supply. For this reason, special care must be taken when choosing the model and number of power supplies needed for the installation. ADS systems are powered by 18 Vdc, but depending on the installation, (number of monitors/telephones installed, type of door release used, line length ...) the power supply necessary may vary in terms of model and number of supplies. - Power Supply Ref. 4830: 18Vdc/3,5A (DIN 6) Power Supply Ref. 4810: 12Vac/1,5A - 18Vdc/1,5A (DIN 10) Power Supply Ref. 4812: 18Vdc/1,5A (DIN 6) Power Supply Ref. 4800: 18Vac/1,5A (DIN 4) Power supplies maximum ratings: MAD E IN SPA IN HIG H CCDRESOLU CAM TIO ERA N PAN 50-60 Hz. +1 50VA 8V 12 V MAX. 1. 5A 1A FU EN TE ALI KIT ME DI NTAC GI TA ION L & TILT 12 Vdc 4830 18Vdc/3,5A 4812 18Vdc/1,5A 4810 18Vdc/1,5A 12Vac/1,5A 4800 18Vac/1,5A 1 1 1 - 1 1 1 - 1 1 1 - 1 1 1 1 1 1 - 1 1 1 - 80 80 60 48 60 - 40 40 40 30 24 24 30 - - - - 2 - - Symbology: City Audio Panel Citymax Audio Panel Direct and Digital Audio Panel HIG H CCDRESOLU CAM TIO ERA N PAN & TILT City Video panel Citymax Video panel Direct and Digital Video Panel Halo Kit Panel Halo Building Panel Page. 32 12 Vac ADS ADS ADS ADS