Preview only show first 10 pages with watermark. For full document please download

9a551001 - Midmark

   EMBED


Share

Transcript

Contents: IQvitals® Table Mount with Connectivity [9A551001] Intended Use: The IQvitals® table mount is intended to provide an adjustable table-mounted support for the IQvitals® device and its accessories. Installation............... 1 Exploded View......... 6 Language of origin: English Restrictions: To be used on 625-004 Midmark table only. Step 1: Remove side cladding. TP200 Rev. A A) Press two tabs. B) Pull bottom of cladding away from table. C) Lift cladding up to remove. Tabs MA9082i © 2013 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com English-1 Style A 003-2694-00 Rev. D (1/26/17) Step 3: Install accessory arm to table. Step 2: Install socket. A) B) C) D) E) Slide socket off of accessory arm. Remove hole plug. Insert socket into hole. Secure socket with two hex screws. Replace cladding on table. A) B) C) D) Position accessory arm as shown. Insert into socket until release lever locks and clicks into place. Pull slightly to ensure it’s in place securely. Secure basket onto arm with washers and nuts onto studs with provided wrench. Hole Plug Socket TP200 Rev. A MA9067i Socket MA9072i Release Lever © 2013 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com English-2 Style A Step 4: Install IQvitals® to accessory arm. A) Unscrew thumb screw. B) Slide IQvitals® monitor onto plate until spring pin locks and clicks into place. C) Tighten thumbscrew under mounting plate to secure IQvitals® . Thumb Screw Equipment Alert Be sure the thumb screw is lowered before installing the IQvitals® onto the mounting plate. TP200 Rev. A Spring Pin MA9068i Thumb Screw © 2013 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com English-3 Style A Step 5: Connect IQvitals® power supply. A) B) C) D) Remove plug-in prongs from IQvitals® power supply. Slide new adapter to IQvitals® power supply. Connect accessory power cord to new adapter/power supply. Connect IQvitals® power supply cord to the second position on the IQvitals® monitor. Note: Accessory power cord is pre-installed and routed through the accessory arm. Plug-in Prongs IQvitals Power Supply Cord Adapter / Power Supply IQvitals Monitor Adapter TP200 Rev. A Accessory Power Cord Located on Accessory Arm Plug into Table Receptacle © 2013 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com English-4 Style A Step 6: Connect Serial Cable and USB Connector... A) B) C) D) E) Plug USB connector into USB port. Plug serial cable to serial port. Place adapter/power supply in holder on basket. Wrap excess cord between the power supply and the IQvitals®. Secure to arm with cable tie. Plug power cord into table receptacle. Adapter/Power Supply Holder Excess Cord & Tie USB Port Receptacle TP200 Rev. A Serial Port MA9051i © 2013 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com English-5 Style A Step 7: To transmit weight data from IQvitals® to a PC... A) Connect USB cable 9A520001 to Port A on the back of the 625-004. B) Connect the other end of USB cable 9A520001 into the USB port on the PC. Note: The PC must have supported software. Port A USB Type A TP200 Rev. A USB Type B 9A520001 (15 Foot) © 2013 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com English-6 Style A 1 040-0250-62 2 050-9130-00 24 042-0672-00 057-1398-00-312 040-0250-20 22 3 040-4016-00 4 052-0831-00 23 5 050-9129-00-216 7 057-1229-00 12 6 029-5349-00 8 057-1230-00 9 053-2234-00-312 045-0027-00 21 041-0250-24 18 041-0250-01 10 040-0250-187 17 11 053-2502-00 20 045-0001-92 10 19 041-0250-25 12 053-2503-00 13 030-2153-00-216 016-1639-00 16 TP200 Rev. A 040-0250-75 15 14 Serial Numbers / Dates: all © 2013 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com English-7 9A551001 IQvitals Table Mount with Connectivity / Upper Section Item Description Qty. 1 Screw (1/4”-20 x 2-3/4”) 2 2 Upper Mounting Plate 1 3 Thumb Screw (10-32 x 1/4”) 1 4 Standoff Post 2 5 Clamp Mount Plate 1 6 Tilt Assembly 1 7 •  Threaded Tilt Block Pivot Pin 1 8 •  Tilt Block Pivot Pin 1 9 •  Tilt Block 1 10 Screw (1/4”-20 x 2-1/2”) 2 11 Rubber Edge Trim 1 12 Basket Clamp 2 13 Mast Weldment 14 Refer to: 9A551001 / Lower Section 15 Set Screw (1/4”-20 x 1/4”) 1 16 Retention Key 1 17 Nut (1/4”-20) 2 18 Washer 2 19 Acorn Nut (1/4”-20) 2 20 Washer 2 21 Square Nut (1/4”-20) 2 22 Wire Basket 1 23 Screw (1/4”-20 x 1-1/2”) 2 24 Spring-Loaded Plunger 1 Style A 1 Ref. 053-2542-00 20 040-0500-37 19 057-1402-00-216 18 040-0250-75 14 042-0056-05 053-1339-00 1 17 17 016-0392-18 16 2 045-0038-00 13 025-0042-11 15 3 052-0841-00-216 042-0606-00 2 12 040-0312-08 11 057-1412-00 030-2151-00-216 015-3341-00 9A551001 IQvitals Table Mount with Connectivity / Lower Section 10 Item 9 8 TP200 Rev. A 4 030-2152-00-216 015-2930-01 7 5 015-3336-00 6 015-3335-00 Serial Numbers / Dates: all © 2013 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com English-8 Description Qty. 1 Refer to: 9A551001 / Upper Section Ref. 2 Bearing Washer 3 3 Sleeve 1 4 Lower Arm Tube 1 5 Adapter Plug 1 6 Power Cord 1 7 Modular Serial Harness 1 8 USB Cable 1 9 Stub Weldment 1 10 Alignment Stud 1 11 Screw (5/16”-18 x 7/8”) 1 12 Clevis Pin 1 13 Armrest Retainer Clip 1 14 Retaining Ring 1 15 Compression Spring 1 16 DU Flange Bearing 1 17 Set Screw (1/4”-20 x 1/4”) 2 18 Top Rotation Cap 1 19 Screw (1/2” x 1-1/4”) 1 20 Dust Cover Cap 1 Style A [Rev. 1/26/17]