Preview only show first 10 pages with watermark. For full document please download

A-00-n$dch/aa Submittal )-0 Series, :doo0rxqwhg(ydsrudwru Samsung

   EMBED


Share

Transcript

SUBMITTAL A-00-N$DCH/AA Samsung )-0 Series, :DOO0RXQWHG(YDSRUDWRU Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval 3DJH1 of 2 Construction Specifications Cooling (Btu/h) 7,000 Heating (Btu/h) 7,500 Nominal Capacity Performance C Condensate 3LQWV+RXU Voltage (ø/V/Hz) Nominal Running Current (A) Type Fan Type FLA / Output Airflow CFM (UL) L/M/H Type 0.12A / 27 W 245 / 260 / 295 Electronic Expansion Valve (at outdoor unit) Control Method Piping Connections %/'& (1) R410A Refrigerant • Refrigerant pipes, drain pipe, high voltage, and low voltage shall be accessible from the bottom of the unit to provide simplified installation and service. 0.3 Crossflow (1) Motor • Triangle design to provide optimal airflow in and out of the unit.  1 / 208-230 / 60 Power • High-voltage terminal block temperature sensor to disable unit in the event overheating of power connection. Liquid (flare) Inches 1/4 Suction (flare) Inches 3/8 Drain Inches ID 11/16" hose 32 1/2 X 10 1/4 X 10 13/16 Unit Dimensions WXHXD Inches Weight OEV 21 Sound Level L/H dB 18 / 38 • Refrigerant and drain pipe direction can be applied to exit the right, left, bottom, or back sides of the indoor unit. • The drain outlet hose can connect to the left (standard) or right side of the drain pain to provide flexibility during installation. • The indoor unit shall be powered by the outdoor unit. Construction HIPS chassis certified to UL94 V0 with galvanized steel mounting bracket Heat Exchanger The heat exchanger shall be mechanically bonded fin to copper tube Indoor Fan Indoor fan is a single, antibacterial, crossflow type Three fan speed settings and auto setting Motorized vertical-swing (up/down) louver Condensate Pump Accessories Wired Remote Controller ASP-MO-UNIV 110-250 Premium ¹ AR-WRP Standard ² AR-WRS02 Line sets - insulated and flared, interconnect cables included Safety Certifications 25' - ILS2506 50' - ILS5006 ETL & ETLc ¹ AQN-WRP includes MWR-WE10 wired controller with scheduling, sub-PCB (DB93-11412A), and sub-PCB harness Controls Control signal shall be a DDC type signal Interconnect control wire between outdoor and indoor shall be 16AWG X 2 shielded The indoor unit shall ship with a wireless controller as standard. Optional wired controller options available Controls shall integrate with a BMS system The system shall integrate with the Samsung Controls Solution. (DB93-11405A). ² AQN-WRS02 includes MWR-WH02 wired controller, sub-PCB (DB93-11412A), and sub-PCB harness (DB93-11405A). Nominal cooling capacities are based on: Indoor temperature: 80ͼF DB, 67ͼF WB. Outdoor temperature: 95ͼF DB, 75ͼF WB. Compatibility Will only operate with Samsung outdoor unit model numbers: AJ020JCJ2CH/AA, AJ024JCJ3CH/AA, AJ036JCJ5CH/AA. Nominal heating capacities are based on: Indoor temperature: 70ͼF DB, 60ͼF WB. Outdoor temperature: 47ͼF DB, 43ͼF WB. Samsung and Quietside maintains a policy of ongoing development, specifications are subject to change without notice. QS-)-0-0B www.4XLHWVLGH.com 888-699-6067 Page 2 of 2 SUBMITTAL A-00-N$DCH/AA Samsung )-0 Series, :DOO0RXQWHG(YDSRUDWRU 723    )5217 /()7 5,*+7  %27720    %$&. 'UDLQSLSHKROH ‘ ' $ 'UDLQSLSHKROH ‘ % & 02817,1*3/$7( A B 1 13/32" 4 3/4" C D 3 3/16" 1 13/32" 0LQLPXPFOHDUDQFHIURPZDOOVDQGFHLOLQJ Name No. PLQLPXP PLQLPXP PLPLPXP EDFNRIXQLW )RUUHIHUHQFHRQO\$OZD\VUHIHUWRLQVWDOODWLRQPDQXDOIRUFRPSOHWHGHWDLOV www.4XLHWVLGH.com 1 2 3 4 5 6 Liquid Pipe Connection Gas Pipe Connection Drain Pipe Connection Conduit for Power & Communication Wiring Air Inlet Grille Air Outlet Louver Description Ø 1/4" Flare Ø  Flare ID 1"+RVH -