Preview only show first 10 pages with watermark. For full document please download

A-11 Door-window Sch..

   EMBED


Share

Transcript

50 FEET A. BOBRICK MODEL NUMBERS GIVEN TO ESTABLISH A STANDARD OF QUALITY, PROVIDE BOBRICK, GAMCO, OR SUBMIT FOR APPROVAL. B. SEE TAS FOR MOUNTING HEIGHTS. 1" 1" 5" 1 1/2'' = 1' - 0'' - - - - - - - - - - - ALARMED EGRESS DEVICE DETEX ECL-230D-PH - NO OUTSIDE TRIM E1 DETEX ECL-600 - ECL 620 - OUTSIDE TRIM E2 6'-0" 3'-4" 16'-0" 3'-4" 3 DOOR HARDWARE SCHEDULE 1 1/2'' = 1' - 0'' 9'-0" H W 3'-0" 7'-0" STRUCTURE CONTINUOUS RUNNER DOUBLE PANE LOW-E GLAZING ALUM. WINDOW SEALANT BOTH SIDES STRUCTURE CONTINUOUS RUNNER 2-1/2" SOUND ATTENUATION BLANKETS 6 W3 DOUBLE PANE LOW-E GLAZING ALUM. WINDOW DOUBLE PANE LOW-E GLAZING ALUM. WINDOW WI-1 SINGLE PANE SAFETY GLAZING ALUM. WINDOW WINDOW TYPES 1 1/2'' = 1' - 0'' 5" NONE 3 STOREROOM 2, 8 4/A-11 NONE 7 EGRESS 7, 2 3 102 ELEV-CNTRL-RM 8 NONE RESTROOM 8 NONE RESTROOM 3 104 STOREROOM 2 NONE CONF. PASSAGE NONE NONE HM/PT NONE NONE NONE HM 4/A-11 4/A-11 SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 - SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 - NONE SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 - NONE 108 3'-0" 7'-0" 1-3/8" HC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 NONE 109 3'-0" 7'-0" 1-3/8" SC/PLAM DI-1 NONE NONE NONE AL/GL 4/A-11 4/A-11 NONE 109A 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 110 3'-0" 7'-0" 1-3/8" SC/PLAM DI-1 NONE NONE NONE AL/GL 4/A-11 4/A-11 2 NONE PASSAGE 2 104 PASSAGE 9 104 OFFICE 2 9 104 OFFICE 2 9 104 OFFICE 111 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 NONE 112 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 NONE 113 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 NONE 4/A-11 NONE 7 3 103 ELEC. ROOM 9 103 OFFICE 1-3/4" HM/PT NONE NONE NONE HM 4/A-11 4/A-11 3'-0" 7'-0" 1-3/8" HC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 NONE 115 3'-0" 7'-0" 1-3/4" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 NONE 116 3'-0" 7'-0" 1-3/4" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 117 3'-0" 7'-0" 1-3/4" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 118 3'-0" 7'-0" 1-3/4" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 119 3'-0" 7'-0" 1-3/4" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 120 3'-0" 7'-0" 1-3/4" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 121 3'-0" 7'-0" 1-3/4" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 122 3'-0" 7'-0" 1-3/4" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 124EX 3'-0" 7'-0" 1-3/4" HM/PT D3 NONE NONE NONE HM 4/A-11 4/A-11 EXTERIOR EGRESS - 7'-0" 114 NONE 9 103 OFFICE - 3'-0" D3 NONE 9 103 OFFICE - 113A - NONE NONE - - 1-3/8" 1-3/8" - 7'-0" 7'-0" - 3'-0" 3'-0" EXTERIOR - 106 107 101 - NONE - 4/A-11 - 4/A-11 NONE 9 103 CONF. ROOM NONE 9 103 OFFICE NONE 9 103 OFFICE NONE 9 103 OFFICE 103 OFFICE NONE 9 4/A-11 NONE 7 EXTERIOR EGRESS 124A 7'-0" 16'-0" AL/PT D4 NONE NONE NONE STL 4/A-11 4/A-11 NONE EXTERIOR GARAGE 124B 7'-0" 8'-0" AL/PT D4 NONE NONE NONE STL 4/A-11 4/A-11 NONE EXTERIOR GARAGE 203 3'-0" 7'-0" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 2 2 - NONE - 1-3/8" NONE NONE NONE NONE NONE NONE NONE NONE 212 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 NONE 212A 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 NONE 213 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 NONE 214 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 NONE 215 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 NONE 216 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 NONE 204 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 206 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 4/A-11 4/A-11 207 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 208 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 209 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 NONE NONE NONE AL 4/A-11 4/A-11 210 3'-0" 7'-0" 1-3/8" SC/PLAM D3 211 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 211A 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 217 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 217A 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 218 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 219 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 220 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 NONE NONE NONE AL 4/A-11 4/A-11 221 3'-0" 7'-0" 1-3/8" SC/PLAM D3 222 3'-0" 7'-0" 1-3/8" SC/PLAM D3 NONE NONE NONE AL 4/A-11 4/A-11 222A 3'-0" 7'-0" 1-3/8" SC/PLAM DI-3 NONE NONE NONE AL/GL 4/A-11 4/A-11 8 NONE RESTROOM 8 NONE RESTROOM 9 200 OFFICE SUITE 2 NONE PASSAGE 9 200 OFFICE SUITE 3 208 STOREROOM 9 208 OFFICE 9 208 OFFICE 9 208 OFFICE 9 208 OFFICE 9 208 OFFICE 4 208 PRIVACY 9 104 OFFICE 9 205 OFFICE SUITE 4 215 PRIVACY NONE 9 205 OFFICE NONE 9 215 OFFICE NONE 9 205 OFFICE NONE 9 205 OFFICE NONE 9 205 OFFICE NONE 3 205 STOREROOM NONE 9 205 CONF. ROOM NONE 9 206 CONF. ROOM 4 3-5/8" METAL STUDS @ 16" O.C. 3-5/8" METAL STUDS @ 16" O.C. SEALANT BOTH SIDES CONTINUOUS RUNNER 1 DOOR SCHEDULE ABBREVIATIONS AL - ANODIZED ALUMINUM FP - FACTORY PAINTED HM - HOLLOW METAL MC - MINERAL CORE PL - PLASTIC LAMINATE CLAD PT - FIELD PAINT SC - SOLID CORE 1 HOUR REFERENCE T-1174-OS2, CEG 7-13-83 U OF C 7-31-62 U.L. DES. U45 A PARTITION TYPES 1 1/2'' = 1' - 0'' REMARKS 9/20/10 FOR BID & PERMIT REVISIONS NO. REMARKS 10/29/10 PERMIT RE-SUBMTL. 1 12/12/10 DRAWING NAME DOOR SCHEDULE DOOR/WINDOW TYPES PARTITION TYPES CONTINUOUS RUNNER SEALANT BOTH SIDES B DATE 5 5/8" GYP BOARD BOTH SIDES 5" PRINTED SCHEDULED CEILING 5/8" GYP BOARD BOTH SIDES SCHEDULED CEILING AL NONE D3 - 3'-0" FINISH FLOOR W2 1, 2, 6, 7 - 3'-0" 4'-0" W1 EGRESS - C EXTERIOR - 5'-0" 3'-0" D 1 1/2'' = 1' - 0'' 1 - 1 HOUR REFERENCE U. OF C. 4-3-75 1 HOUR REFERENCE U.L. DES. U 420 FLOOR PENETRATION (WHERE APPLICABLE) 1-3/8" NONE EXTR. ENTRY PRE-FINISHED AL. FRAME DOOR TYPE/INTR. WINDOW TYPES STEEL J RUNNER FLOOR SLAB 1-3/4" 7'-0" (2)2'-0" AL - CONTINUOUS RUNNER 5 5'-0" SEALANT 7'-0" 105 NONE NONE - 3" DI-5 TG - 5 SC/PLAM 1, 2, 6 DX1 INTR. S.C. WD. DR. IN ALUM. FRAME POCKET DOOR 9'-0" SEALANT BOTH SIDES STEEL C-H STUDS @ 24" O.C. DI-5 D5 PRE-FINISHED AL. GARAGE DOOR 3'-5" 4'-0" METAL RUNNER DI-4 INTR. S.C. WD. DR. IN ALUM. FRAME 1-3/4" EGRESS - SCHEDULED CEILING SCHEDULED CEILING PLANDIMENSION 1" GYP BOARD SHAFT WALL LINER 7'-0" EXTERIOR - 1/2" GYP BOARD 6'-0" 5'-6" SCHEDULED CEILING 7'-0" 3'-5" 1-5/8" METAL STUDS @ 16" O.C. 5/8" GYP BOARD BOTH SIDES STEEL J RUNNER 7'-0" NO. 8 X 1/2" SELF TAPPING SCREWS 1" SOUND ATTENUATION BLANKETS DX1 1 - 2'-8" INTR. S.C. WD. DR. W/GLASS LITE IN ALUM. FRAME STRUCTURE 7'-0" STRUCTURE CONTINUOUS RUNNER SEALANT AL NONE - INTR. S.C. WD. DR. W/GLASS LITE IN ALUM. FRAME DI-3 9'-0" E 1-3/4" AL - 3'-4" 7'-0" DI-2 INTR. S.C. WD. DR. W/GLASS LITE IN ALUM. FRAME 3'-4" 8'-0" 7'-0" NONE NONE - DI-1 100EEX (2)3'-0" 3'-0" 101 103EX 3'-0" TG - SCHEDULED FLOORING AL SILL NOTES FUNCTION - 3'-0" SCHEDULED BASE ACOUSTIC SEALANT BOTH SIDES 1-3/4" JAMB KEYSIDE RM NO - 3'-0" 5" CONTINUOUS RUNNER F 3'-4" CONTINUOUS RUNNER 2" SOUND ATTENUATION BLANKETS 7'-0" HEAD SET NO - SEALANT BOTH SIDES 3'-0" SEALANT 5/8" GYP BOARD BOTH SIDES (2)3'-0" H FIRE RATING LABEL - CONTINUOUS RUNNER 3'-4" D4 PRE-FINISHED AL. GARAGE DOOR 6'-0" 5" 5 D3 EXTR. MTL. DOOR IN MTL. FRAME 7'-0" 3-5/8" METAL STUDS @16" O.C. 5/8" GYP BOARD BOTH SIDES SHEDULED CEILING 3-5/8" METAL STUDS @ 24" O.C. MAX. D2 EXTR. MTL. DOOR IN MTL. FRAME W T D1 100EX EXTR. ENTRY PRE-FINISHED AL. FRAME 7'-0" CONTINUOUS RUNNER 3'-5" D1 3'-0" SCHEDULED CEILING 6'-0" DETAIL MATL - STRUCTURE HANGER WIRE 3'-5" LOUVER - INSTALL 3" BATT INSULATION 4'WIDE BOTH SIDES OF PARTITION TEE GRID EL GLAZING - 1 1/2'' = 1' - 0'' MATL(S) HARDWARE 7521 WESTVIEW DRIVE HOUSTON, TEXAS 77055 SIZE MARK FRAME - 7'-0" 7'-0" 3'-0" ACCESSORY SCHEDULE 7'-0" DOOR 7521 WESTVIEW DRIVE 0 1 DOOR AND FRAME SCHEDULE - 10 WEATHERSTRIP WS1 NATIONAL GUARD #160V WITH NEOPRENE BULB - AL DRIP CAP DC1 NATIONAL GUARD #16A - AL SWEEP SW1 NATIONAL GUARD 200N - AL STOPS S1 TRIMCO #1216 HD DOME STOP - AL S2 TRIMCO #1201 RAISED STOP - AL 3. WALL HAS BEEN FURRED TO ALLOW FOR FULL RECESSED UNIT. UNIT MAY BE SURFACE MOUNTED PROVIDED IT PROTRUDES NO MORE THAN 4" INTO ROOM. COORDINATE WITH 4. NOT USED 5. PERMANANT INSTALLATION WITH MASTIC, SEAL EDGES WITH CLEAR SILICONE SEALANT. 6. NOT USED 7. TEXAS ACCESSIBILITY STANDARDS REQUIRE THAT NO WALL MOUNTED ITEM PROTRUDE INTO ROOM MORE THAN 4" AT THIS MOUNTING HEIGHT. 4 - BOLTS B1 HEAD AND SILL FLUSH BOLTS BY STOREFRONT MFR. ACCESSORY SCHEDULE NUMBERED NOTES: 1. PROVIDE BLOCKING IN WALL. GRAB BARS MUST RESIST 250 POUND LOAD APPLIED IN ANY DIRECTION OR LOCATION. BLOCKING MUST BE FIRE TREATED. RE: G002 2. MOUNT HOOKS AT 48" AFF. OWNER/TENANT TO DETERMINE IF RECESSED POCKET IS REQUIRED. 8 CLOSER C1 SARGENT 350/351 SERIES WITH APPROPRIATE ACCESSORIES, ADA COMPLIANT - PAINT KICK PLATE KP1 ROCKWOOD KICK PLATE - US26D - BOTH SIDES, (2) PER DOOR PUSH/PULL PP1 TRIMCO 1737 1" SERIES OFFSET PUSH/PULL BAR SET - US26D PP2 TRIMCO 1069 SERIES PASSAGE PULL - US32D SILENCER SR1 TRIMCO #1229A - GRAY SILL SL1 NATIONAL GUARD #869V WITH NEOPRENE BULB - AL LOCKS L1 DEADBOLT ADAMS-RITE (OR EQUAL) MS1850 - US26D L2 SARGENT (OR EQUAL) 10U15 PASSAGE FUNCTION (ANSI F75) - US26 L3 SARGENT (OR EQUAL) 10U65 PRIVACY FUNCTION (ANSI F76) - US26D L4 SARGENT (OR EQUAL) 10G04 STOREROOM/UTILITY FUNCTION (ANSI F86) - U26D L5 SARGENT (OR EQUAL) 10G05 OFFICE/ENTRY FUNCTION (ANSI F81) - U26D INTERIOR DOOR/WINDOW DETAILS 4 ACCESSORY SCHEDULE GENERAL NOTES: 2" GLASS SR1 - 25 BOBRICK B232 X36" 4 HOOK STRIP 2 HARDWARE ITEMS HINGES/PIVOTS H1 PBB 4"X4" PB51 SQUARE, NORMAL DUTY H2 PBB 4"X4" TBB HEAVY DUTY X NRP US32D STAINLESS P1 MINIMUM (2) PAIR PIVOTS BY ENTRANCE MFR. HOLLOW MTL. DOOR FRAME SCHEDULED DOOR CEILING STEEL REINFORCING C1 HARDWARE SET SCHEDULE NUMBERED NOTES 1. SEE DOOR SCHEDULE FOR SIGNAGE REQUIREMENTS. 2. BALANCE OF HARDWARE BY DOOR SUPPLIER P.O. Box 841834 HOUSTON, TEXAS 77284 PHONE: 281.851.1465 FAX: 281.656.5871 EMAIL: [email protected] LINE OF INTERSECTING WALL RE: PLAN TOILET PARTITION SCHEDULED ANCHORS S1 S1 Caleble Custom Design TEE GRID SCHEDULED PARTITION 8 11/2" 1/2" 1/2" 7 SCHEDULED PARTITION 7 OWNER SUPPLIED CONTRACTOR INSTALLED SOAP DISH DISPENSER - SIM. TO BOBRICK B5090 L5 L5 DC1,SW1, WS1,SL1 DC1,SW1, WS1,SL1 - STUD 1 PP2 - GLASS SEALANT 6 C1 C1 KP1 - - 8 9 (1.5PR) H1 10 (1.5PR) H2 SCHEDULED PARTITION FINISH FLOOR GLASS - - STONE VENEER OVER SHEATHING OVER BLDG. PAPER GLASS HARDWARE SET SCHEDULE GENERAL NOTES 1. NUMBERS IN PARENTHESIS INDICATED NUMBER OF ITEMS REQUIRED 2. HARDWARE SCHEDULE INDICATES ARCHITECT'S INTENT. SUPPLIER RESPONSIBLE FOR PROVIDING ALL ACCESSORIES OR MODIFYING THIS SCHEDULE TO INSTALL FUNCTIONING DOOR HARDWARE SYSTEMS PROVIDED BY LANDLORD. 3. LOCKSET CYLINDERS SHALL BE CAPABLE OF GRAND MASTERKEYING. COORDINATE WITH OWNER FOR KEYING SCHEME. 4. PROVIDE CLOSER FOR SOLID CORE DOOR AS AN ALTERNATE NOTES 1 - 5 SCHEDULED DOOR GLASS - PLATE GLASS MIRROR BOBRICK B290 24" WIDE, 36" HIGH MOUNT BOTTOM EDGE AT 40" AFF SCHEDULED PARTITION - 3, 7 C1 - OWNER SUPPLIED CONTRACTOR INSTALLED PAPER TOWEL DISPENSER/RECEPTACLE SILENCR OTHER - 4 CLOSR PUSH/PULL (2) PP1 (2) C1 - 2, 7 SCHEDULED GLASS TYPE - CLOTHING HOOK BOBRICK B6827 ANCHOR AS REQ'D - ANCHOR AS REQ'D - 3 5 ALUM. STUD 2" VINYL INSERT STEEL REINFORCING GLASS 2" - 1 2" - GRAB BARS BOBRICK B6806 SERIES SCHEDULED CEILING TEE GRID HARDWARE SETS SCHEDULE LOCK BOLTS STOP NO. HINGES L1 B1 (2) S2 1 (1PR) P1 S1 L2 (1.5PR) H1 2 S1 L4 3 (1.5PR) H1 S1 L3 4 (1.5PR) H1 (1.5PR) H1 L4 S1 5 E1 S2 6 (1.5PR) H2 E2 S2 7 (1.5PR) H2 THICKNESS +1/16" 2" 1/2" 2 SCHEDULED DOOR 2" 1 TOILET PAPER DISPENSER BOBRICK B2740 NOTES 1/2" DESCRIPTION (RECOMMENDED MFR.) 2" MARK SCHEDULED DOOR - THICKNESS +1-1/16" ACCESSORY SCHEDULE 2 ST - SHOP STAIN W/SATIN. POLYURETHANE FINISH STL - FORMED STEEL TG - TEMPERED GLASS VP - VISION PANEL HC - HOLLOW CORE WD - WOOD DOOR SCHEDULE 1 1/2'' = 1' - 0'' DOOR SCHEDULE NUMBERED NOTES 1. DOOR TO HAVE A READILY VISIBLE, DURABLE SIGN ON OR ADJACENT TO 8. PROVIDE COMPLETE FRAME & HARDWARE FOR SLIDING POCKET DOOR DOOR STATING "THIS DOOR TO REMAIN UNLOCKED .U 5. PROVIDE ADA COMPLIANT RESTROOM SIGNAGE ADJACENT TO DOOR DURING BUSINESS HOURS" IN 1" HIGH LETTERS 6. PROVIDE SIDELITES AND TRANSOM AS SHOWN ON DOOR TYPE ELEVATION 2. COORDINATE KEYING REQUIREMENTS WITH OWNER. CYLINDERS SHALL BE CAPABLE OF GRAND MASTERKEYING. 3. NO EXTERIOR HARDWARE ON THIS DOOR 4. PROVIDE COMPLETE FRAME & HARDWARE FOR SLIDING POCKET DOOR 5. PROVIDE ADA COMPLIANT RESTROOM SIGNAGE ADJACENT TO DOOR 6. PROVIDE SIDELITES AND TRANSOM AS SHOWN ON DOOR TYPE ELEVATION 7. UNLOCK BY ELECTRONIC ACCESS CARD, COORDINATE W/SECURITY CONTRACTOR PROJECT NO.: 1022010 DATE: 07-15-10 PHASE: DRAWING NO. A-11