Transcript
NEW!
POWER MONITORING & PROTECTION ACI CURRENT-OPERATED SWITCHES A/ACS, A/ASCS, A/CS, A/SCS, A/CR SERIES DESCRIPTION The ACI current switches are solid-state devices that operate when the sensed AC current level exceeds a fixed or adjustable trip point. The A/CS Series is solid-core with a fixed trip point. The A/SCS Series is split-core with a fixed trip point. The A/ACS Series is solid-core with adjustable trip point. The A/ASCS Series is split-core with adjustable trip point. All models monitor either a 0-200 or 0-250 amp current flow in the wire and are available in normally-open or normally-closed configurations. The A/CR Series command relay brings control to monitoring applications.
A/CS, A/ACS
POWER MONITORING & PROTECTION
FEATURES
16
• • • • • • • •
Available in solid or split-core Fixed or adjustable trip points Switches AC or DC circuits Status LED's Integral DIN rail mount Powered by monitored line Enclosure rated UL94-5VB Pilot duty rated (A/CR Series)
A/SCS, A/ASCS A/CR-D-12A
SPECIFICATIONS Supply Voltage Frequency Outputs Normally Open Normally Closed Isolation Rating Insulation LED Indication Adjustable Fixed Deadband
Induced from monitored conductor 40 Hz to 1 kHz 0.3A @ 200 VAC/VDC 0.15A @ 300 VAC/VDC 1270 VAC 600 VAC Red = Above trip point Green = Below trip point Red LED only 10% Setpoint
Operating Temperature 5° to 104°F (-15° to 40°C) Operating Humidity 0 to 95% RH,(non-condensing) Mounting DIN rail (35 mm), screw Window Size 0.75" (1.9 cm), accepts up to 350 MCM cables Weight 0.21 lb (0.1 kg) Approvals UL and cUL listed, file #E309723 and #E179139 CE RoHS Statement Yes Warranty 5 years, limited
RELAY SPECIFICATIONS (COMMAND RELAY) A/CR-DC-5A Relay Type Contact Rating SPDT 5A @ 250 VAC General Use Coil Voltage 5A @ 125 VAC Resistive 23-31.2 VDC 5A @ 30 VAC Resistive Coil Current 1/4HP, 120/250/277 VAC 15mA @ 24 VDC C 150 Pilot Duty A/CR-24AC-10A Relay Type Contact Rating SPDT 10A @ 250 VAC General Use Coil Voltage 10A @ 250 VAC Resistive 16-25.4 VAC 10A @ 30 VAC Resistive Coil Current 1HP, 120/240/480 VAC-NO 28mA @ 24 VAC 1/2HP, 120/240/480 VAC-NO A300 Pilot Duty
942
888-397-5353 USA
kele.com
A/CR-DC-12A Relay Type Contact Rating SPDT 12A @ 250 VAC General Use Coil Voltage 12A @ 125 VAC Resistive 20-31.2 VDC 12A @ 30 VAC Resistive Coil Current 1/2HP, 120/250/480 VAC-NC 16mA @ 24 VDC A300 Pilot Duty A/CR-115AC-8A Relay Type Contact Rating SPDT 8A @ 250 VAC General Use Coil Voltage 8A @ 250 VAC Resistive 80-132 VAC 8A @ 30 VAC Resistive Coil Current 1HP, 120/240/480 VAC-NO 10mA @ 115 VAC 1/2HP, 120/240/480 VAC-NC A300 Pilot Duty
A/CR-12DC-12A Relay Type Contact Rating SPDT 12A @ 250 VAC General Use Coil Voltage 12A @ 250 VAC Resistive 10-15.6 VDC 12A @ 30 VDC Resistive Coil Current 1/2HP, 120/240/480 VAC-NC 30mA @ 24 VDC A300 Pilot Duty A/CR-230AC-8A Relay Type Contact Rating SPDT 8A @ 250 VAC General Use Coil Voltage 8A @ 125 VAC Resistive 165-264 VAC 8A @ 30 VAC Resistive Coil Current 1HP, 120/240/480 VAC-NO 5mA @ 230 VDC 1/2HP, 120/240/480 VAC-NC A300 Pilot Duty
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
March 2014
NEW!
POWER MONITORING & PROTECTION ACI CURRENT-OPERATED SWITCHES A/ACS, A/ASCS, A/CS, A/SCS, A/CR SERIES
DIMENSIONS
Top View
in (cm)
Adjustment range: 3.0-200A Trip on = Above trip point
0.40 (1.0)
Ø0.21 (0.5) Typ.
Top View in (cm)
A/ASCS only
Ø0.22 (0.6) Typ.
Adjustment range: 3.0-200A Trip on = Above trip point
0.50 (1.3)
Use Insulated Conductors Only
Use Insulated Conductors Only
2.84 (7.2)
2.84 (7.2)
Front View
Front View
Ø0.78 (2.0)
1.38 (3.5)
0.74 (1.9)
0.76 (1.9)
0.14 (0.4)
0.14 (0.4)
1.38 (3.5)
3.38 (8.6)
3.33 (7.8)
Top View
1.320 (3.3)
Ø0.188 (.4) (2X)
1.107 (2.8)
Front View
A/CR-CD-12A 1.632 (4.1) 1.516 (3.8)
2.884 (7.3) 1.351 (3.4) Din rail size
3.290 (8.3)
16
ORDERING INFORMATION MODEL A/CS A/CS-L A/CS-X A/CS-X-L A/ACS A/ACS-L A/ACSX A/SCS A/SCS-L A/SCSX A/ASCS A/ASCS-L A/ASCSX A/ASCSX-L A/CR-DC-5A A/CR-DC-12A A/CR-12DC-12A A/CR-24AC-10A A/CR-115AC-8A A/CR-230AC-8A March 2014
POWER MONITORING & PROTECTION
A/ASCS, A/SCS
DESCRIPTION Solid-core current switch, 0.5A trip, normally-open, 0-250A range Solid-core current switch, 0.2A trip, normally-open, 0-250A range Solid-core current switch, 1A trip, normally-closed, 0-250A range Solid-core current switch, 0.5A trip, normally-closed, 0-250A range Solid-core current switch, adjustable trip, normally-open, 1-250A range Solid-core current switch, adjustable trip, normally-open, 0.5-250A range Solid-core current switch, adjustable trip, normally-closed, 1-250A range Split-core current switch, 2.5A trip, normally-open, 0-200A range Split-core current switch, 1.5A trip, normally-open, 0-200A range Split-core current switch, 2.5A trip, normally-closed, 0-250A range Split-core current switch, adjustable trip, normally-open, 3-200A range Split-core current switch, adjustable trip, normally-open, 2-200A range Split-core current switch, adjustable trip, normally-closed, 3-250A range Split-core current switch, adjustable trip, normally-closed, 2.5-250A range 5 Amp SPDT relay, 23-31.2 VDC coil voltage 12 Amp SPDT relay, 20-31.2 VDC coil voltage 12 Amp SPDT relay, 10-15.6 VDC coil voltage 10 Amp SPDT relay, 16-26.4 VAC coil voltage 8 Amp SPDT relay, 80-132 VAC coil voltage 8 Amp SPDT relay, 165-264 VAC coil voltage
WE MAKE IT EASY.
kele.com
888-397-5353 USA
943