JEVB500
MAKE & BREAK LOAD SWITCHING GAS CHARGE RELAY 3.15 (80.0)
NOTES:
1.23 (31.2) MAX.3.86 (98.0) MAX.3.07 (78)
MAX.3.76 (95.5)
M8 X 1.25 POWER TERMINALS 2 X M8 WASHER,STAINLESS 2 X M8 LOCKWASHER-SPLIT RING, STAINLESS 2 X M8 x 1.25 NUT, STAINLESS TORQUE 8.8 TO 11Nm (80 TO 100 Kgf.cm)
3.15 (80.0) 2.64 (67.0)
2-M5~M6 BOLT MOUNT SCREW 3.15 (80.0)
2.64 (67.0)
A1"+"POSITIVE TERMINAL
3.46 (88.0) 3.15 (80.0)
WHITE=AUX.CONTACT (22AWG)
A2'-'NEGATIVE TERMINAL
RED=(+)COIL(22AWG) BLACK=(-)COIL(22AWG)
MAX. .52 (13.2)
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES DECIMALS X .1, X.X X.XX .01
.05,
CODE IDENT.NO.
A
ANGLES 2
SIZE DRAWING NO.
DATE:12/21/2015
JEVB500
WEIGHT: 42.33oz
SHEET: 1 OF 3
REV
A
JEVB500
MAKE & BREAK LOAD SWITCHING GAS CHARGE RELAY MAGNET COIL RATING NOMINAL VOLTAGE (V)
ITEM
INRUSH COIL CURRENT 100ms (MAX.)
HOLDING COIL CURRENT (mA)
PICK-UP VOLTAGE (V) MAX.
DROP-OUT VOLTAGE (V) MIN.
HOLDING VOLTAGE (V) MIN.
MAX VOLTAGE (V)
1.3A
0.045-0.07A
32VDC
18VDC
22VDC
95VDC
9VDC
6VDC
7.5VDC
36VDC
72 72
60 36 36
36
0.09A
24
3.8A
12
0.13A 0.27A
12
1.5A
0.35A
9VDC
6VDC
7.5VDC
18VDC
24
0.7A
0.20A
18VDC
12VDC
13.5VDC
32VDC
CHARACTERISTICS MECHANICAL (MIN.) EXPECTED LIFE
ELECTRIC (MIN.) (L/R=<1ms)
2x10^6
750V DC(+),(-) 500A
1x10^3
1000V DC(+),(-) 300A
1x10^3
1500V DC(+),(-) 100A
1x10^3 MIN. 100Mohms 500V DC
INITIAL INSULATION RESISTANCE INTIAL BREAKDOWN VOLTAGE
4500V AC 60SEC. 5mA
OPERATE TIME (AT 20C)
MAX. 40ms
RELEASE TIME (AT 20C)
AMBIENT TEMPERATURE
MAX. 10ms MIN. 196m/s^2 {20G} MIN. 490m/s^2 {50G} 100m/s^2 {20G} 80 TO 2000Hz 100m/s^2 {20G} 80 TO 2000Hz -40C TO +85C
HUMIDITY
5 TO 85% R.H.
FUNCTIONAL DESTRUCTIVE
CONDITIONS FOR OPERATION TRANSPORT AND STORAGE
UNIT WEIGHT
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES
.05,
BETWEEN CONTACTS & COIL
DESTRUCTIVE
VIBRATION RESISTANCE
X .1, X.X X.XX .01
4500V AC 60SEC. 5mA
FUNCTIONAL
SHOCK RESISTANCE
DECIMALS
BETWEEN OPEN CONTACTS
CODE IDENT.NO.
SIZE DRAWING NO.
A
ANGLES 2
1200g
DATE:12/21/2015
JEVB500
WEIGHT: 42.33oz
SHEET: 2 OF 3
REV A MAKE & BREAK LOAD SWITCHING GAS CHARGE RELAY
CONTACT RATING ITEM
1 POLE RESISTIVE LOAD (L/R=<1ms)
MAX. CONTINUOUS CURRENT (WIRE SIZE 325mm^2)
500A 750V DC 500A
MAX. SWITCHING CURRENT
1000V DC 300A 1500V DC 100A
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES DECIMALS X .1, X.X X.XX .01
.05,
CONTACT RATING SWITCHING VOLTAGES
12-1500V DC 100A
VOLTAGE DROP ACROSS CONTACTS PER 100A
300mV MAX.
MIN. PERMISSIBLE LOAD
12V DC 0.5A
DESCRIPTION
S.P ON/OFF (A)
CONTACT ARRANGEMENT, AUXILIARY CONTACTS
1FORM A (SPST-NO.)
GENERAL AUX. CONTACT CURRENT,MAX.
2A 30VDC/3A 125VAC
GENERAL AUX. CONTACT CURRENT,MIN.
100mA 8VDC
GOLD ALLOW AUX. CONTACTS MAX.
0.1A 30VDC/ 0.1A 30VAC
GOLD ALLOW AUX. CONTACTS MIN.
1mA 5VDC/ 1mA 5VAC
CODE IDENT.NO.
A
ANGLES 2
SIZE DRAWING NO.
DATE:12/21/2015
JEVB500
WEIGHT: 42.33oz
SHEET: 3 OF 3