REV A JEVB500 MAKE & BREAK LOAD SWITCHING GAS CHARGE RELAY 3.15 (80.0) NOTES: 1.23 (31.2) MAX.3.86 (98.0) MAX.3.07 (78) MAX.3.76 (95.5) M8 X 1.25 POWER TERMINALS 2 X M8 WASHER,STAINLESS 2 X M8 LOCKWASHER-SPLIT RING, STAINLESS 2 X M8 x 1.25 NUT, STAINLESS TORQUE 8.8 TO 11Nm (80 TO 100 Kgf.cm) 3.15 (80.0) 2.64 (67.0) 2-M5~M6 BOLT MOUNT SCREW 3.15 (80.0) 2.64 (67.0) A1"+"POSITIVE TERMINAL 3.46 (88.0) 3.15 (80.0) WHITE=AUX.CONTACT (22AWG) A2'-'NEGATIVE TERMINAL RED=(+)COIL(22AWG) BLACK=(-)COIL(22AWG) MAX. .52 (13.2) UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES DECIMALS X .1, X.X X.XX .01 .05, CODE IDENT.NO. A ANGLES 2 SIZE DRAWING NO. DATE:12/21/2015 JEVB500 WEIGHT: 42.33oz SHEET: 1 OF 3 REV A JEVB500 MAKE & BREAK LOAD SWITCHING GAS CHARGE RELAY MAGNET COIL RATING NOMINAL VOLTAGE (V) ITEM INRUSH COIL CURRENT 100ms (MAX.) HOLDING COIL CURRENT (mA) PICK-UP VOLTAGE (V) MAX. DROP-OUT VOLTAGE (V) MIN. HOLDING VOLTAGE (V) MIN. MAX VOLTAGE (V) 1.3A 0.045-0.07A 32VDC 18VDC 22VDC 95VDC 9VDC 6VDC 7.5VDC 36VDC 72 72 60 36 36 36 0.09A 24 3.8A 12 0.13A 0.27A 12 1.5A 0.35A 9VDC 6VDC 7.5VDC 18VDC 24 0.7A 0.20A 18VDC 12VDC 13.5VDC 32VDC CHARACTERISTICS MECHANICAL (MIN.) EXPECTED LIFE ELECTRIC (MIN.) (L/R=<1ms) 2x10^6 750V DC(+),(-) 500A 1x10^3 1000V DC(+),(-) 300A 1x10^3 1500V DC(+),(-) 100A 1x10^3 MIN. 100Mohms 500V DC INITIAL INSULATION RESISTANCE INTIAL BREAKDOWN VOLTAGE 4500V AC 60SEC. 5mA OPERATE TIME (AT 20C) MAX. 40ms RELEASE TIME (AT 20C) AMBIENT TEMPERATURE MAX. 10ms MIN. 196m/s^2 {20G} MIN. 490m/s^2 {50G} 100m/s^2 {20G} 80 TO 2000Hz 100m/s^2 {20G} 80 TO 2000Hz -40C TO +85C HUMIDITY 5 TO 85% R.H. FUNCTIONAL DESTRUCTIVE CONDITIONS FOR OPERATION TRANSPORT AND STORAGE UNIT WEIGHT UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES .05, BETWEEN CONTACTS & COIL DESTRUCTIVE VIBRATION RESISTANCE X .1, X.X X.XX .01 4500V AC 60SEC. 5mA FUNCTIONAL SHOCK RESISTANCE DECIMALS BETWEEN OPEN CONTACTS CODE IDENT.NO. SIZE DRAWING NO. A ANGLES 2 1200g DATE:12/21/2015 JEVB500 WEIGHT: 42.33oz SHEET: 2 OF 3 REV A MAKE & BREAK LOAD SWITCHING GAS CHARGE RELAY CONTACT RATING ITEM 1 POLE RESISTIVE LOAD (L/R=<1ms) MAX. CONTINUOUS CURRENT (WIRE SIZE 325mm^2) 500A 750V DC 500A MAX. SWITCHING CURRENT 1000V DC 300A 1500V DC 100A UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES DECIMALS X .1, X.X X.XX .01 .05, CONTACT RATING SWITCHING VOLTAGES 12-1500V DC 100A VOLTAGE DROP ACROSS CONTACTS PER 100A 300mV MAX. MIN. PERMISSIBLE LOAD 12V DC 0.5A DESCRIPTION S.P ON/OFF (A) CONTACT ARRANGEMENT, AUXILIARY CONTACTS 1FORM A (SPST-NO.) GENERAL AUX. CONTACT CURRENT,MAX. 2A 30VDC/3A 125VAC GENERAL AUX. CONTACT CURRENT,MIN. 100mA 8VDC GOLD ALLOW AUX. CONTACTS MAX. 0.1A 30VDC/ 0.1A 30VAC GOLD ALLOW AUX. CONTACTS MIN. 1mA 5VDC/ 1mA 5VAC CODE IDENT.NO. A ANGLES 2 SIZE DRAWING NO. DATE:12/21/2015 JEVB500 WEIGHT: 42.33oz SHEET: 3 OF 3