Preview only show first 10 pages with watermark. For full document please download

A-las Series - Sensor Instruments

   EMBED


Share

Transcript

A-LAS Series • Data Sheet Analog Laser Light Barriers SI-CON8 A-LAS Series SI-CON8 Electronic control unit - For control of A-LAS analog laser light barriers 100%-check of objects (tolerance band monitoring) Positioning and thickness check of objects (in μm-range) High trigger accuracy (in μm-range) High switching frequency (typ. 30 kHz) Parameterizable under Windows® Threshold correction can be activated via PC Adjustment of trigger threshold and tolerance band via Windows® software - Output polarity can be switched via software - Dirt accumulation compensation - Sturdy metal housing Design Product name: SI-CON8 (incl. Windows® PC software SI-CON8-Scope) Mounting holes Aluminium housing, anodized in blue 8-pole connector Binder Series 712 (connetion to PLC) Connecting cable: cab-las8/702-fem or cab-las8/702-fem-w 5-pole fem. connector Binder Series 712 (connection to PC) Connecting cable: cab-las5/PC or cab-5/USB or cab-5/ETH 7-pole fem. connector Binder Series 712 (connection A-LAS light barrier) Connecting cable: cab-las-y or cab-las-y-male Sensor Instruments GmbH • D-94169 Thurmansbang • Schlinding 11 Tel. +49 (0)8544 9719-0 • Fax +49 (0)8544 9719-13 [email protected] • www.sensorinstruments.de (2017-07-10) SI-CON8 / Page 1 of 6 (0628.00) Subject to alteration A-LAS Series • Data Sheet Analog Laser Light Barriers SI-CON8 Technical Data Mo d e l S I- C ON 8 Vo lta g e s up p ly +2 4 V D C (± 1 0 %), re ve rs e d -p o la ri ty p ro te c te d , o ve rlo a d p ro te c te d C urre nt c o ns ump ti o n ma x. 1 5 0 mA Mi n. d e te c ta b le o b je c t < 1 0 μm (d e p e nd s o n a p e rture s i ze o f A -L A S s e ns o r) Re s o luti o n 0 ,4 % (1 0 0 % = a p e rture s i ze o f A -L A S s e ns o r) Op e ra ti ng te mp e ra ture ra ng e - 2 0 ° C ... + 5 5 ° C Sto ra g e te mp e ra ture ra ng e - 2 0 ° C ... + 8 5 ° C E nc lo s ure ra ti ng IP 6 4 Thre s ho ld c o rre c ti o n c a n b e a c ti va te d vi a P C A NA L OG o utp ut 0 V ... 1 0 V D IGITA L o utp ut a d jus ta b le vi a P C : Qi nv: NP N b ri g ht-s wi tc hi ng (NP N no rma lly c lo s e d ) / P NP d a rk -s wi tc hi ng P NP no rma lly o p e n) Q: NP N d a rk -s wi tc hi ng (NP N no rma lly o p e n) / P NP b ri g ht-s wi tc hi ng (P NP no rma lly c lo s e d ) C urre nt c o ntro l i np ut (I-C ONTROL ) L a s e r p o we r a d jus ta b le vi a P C Typ e o f c o nne c to r C o nne c ti o n to P L C : 8 -p o le c o nne c to r B i nd e r S e ri e s 7 1 2 C o nne c ti o n to P C : 5 -p o le fe m. c o nne c to r B i nd e r S e ri e s 7 1 2 C o nne c ti o n to s e ns o r: 7 -p o le fe m. c o nne c to r B i nd e r S e ri e s 7 1 2 C o nne c ti ng c a b le s C o nne c ti o n to P L C : c a b -la s 8 /7 0 2 -fe m C o nne c ti o n to P C : c a b -la s 5 /P C o r c a b -5 /US B o r c a b -5 /E TH D yna mi c s wi tc hi ng o utp ut (p uls e le ng the ni ng ) S wi tc hi ng fre q ue nc y Ma x. s wi tc hi ng c urre nt c a n b e a c ti va te d vi a P C (0 ms ... 1 0 0 ms ) typ . 3 0 k Hz 1 0 0 mA , s ho rt-c i rc ui t p ro o f B a nd wi d th (a na lo g s i g na l) 1 k Hz (-3 d B ) S c a n fre q ue nc y ma x. 2 0 0 k Hz Inte rfa c e Ho us i ng ma te ri a l Ho us i ng d i me ns i o ns E M C te s t a c c . to Sensor Instruments GmbH • D-94169 Thurmansbang • Schlinding 11 Tel. +49 (0)8544 9719-0 • Fax +49 (0)8544 9719-13 RS 2 3 2 , p a ra me te ri s a b le und e r Wi nd o ws ® A lumi ni um, a no d i ze d i n b lue L xWxH a p p ro x. 6 0 mm x 5 0 mm x 2 2 mm (wi tho ut c o nne c to r fla ng e s ) D IN E N 6 0 9 4 7 -5 -2 [email protected] • www.sensorinstruments.de (2017-07-10) SI-CON8 / Page 2 of 6 (0628.00) Subject to alteration A-LAS Series • Analog Laser Light Barriers Data Sheet SI-CON8 Dimensions All dimensions in mm Sensor Instruments GmbH • D-94169 Thurmansbang • Schlinding 11 Tel. +49 (0)8544 9719-0 • Fax +49 (0)8544 9719-13 [email protected] • www.sensorinstruments.de (2017-07-10) SI-CON8 / Page 3 of 6 (0628.00) Subject to alteration A-LAS Series • Data Sheet Analog Laser Light Barriers SI-CON8 Connector Assignment Connection SI-CON8 to PLC: 8-pole connector Binder Series 712 Pin: 1 2 3 4 5 6 7 8 (wire of cable) (white) (brown) (green) (yellow) (grey) (pink) (blue) (red) Assignment: GND (0V) +Ub (+24VDC ± 10%) IN0 OUT0 (Digital 0: Type 0 ... 1V, Digital 1: Type +Ub - 10%) OUT1 (Digital 0: Type 0 ... 1V, Digital 1: Type +Ub - 10%) ANALOG (0V ... +10V) not connected not connected Connecting cable: cab-las8/702-fem-(length) or cab-las8/702-fem-w-(length) (angle type 90°) (standard length 2m, available up to length 25m) Connection SI-CON8-FIO to PC: 5-pole fem. connector Binder Series 712 Pin: 1 2 3 4 5 Assignment: 0V (GND) TxD RxD +24VDC (+Ub, OUT) not connected cab-las8/702-fem or cab-las8/702-fem-w cab-las5/PC or cab-5/USB or cab-5/ETH PC PLC Connecting cable: cab-las5/PC-(length) or cab-las5/PC-w-(length) (angle type 90°) (standard length 2m, also available: length 5m) alternative: Connection via USB-interface at PC: Connecting cable (incl. driver software): cab-5/USB-(length) or cab-5/USB-w-(length) (angle type 90°) (standard length 2m, also available: length 0.5m, 1m) alternative: Connection to local network via Ethernet bus: Adapter (incl. software „SensorFinder“): cab-4/ETH-500 (standard length 0.5m) Optional: External CAT5 cable, e.g. cab-eth/M12D-RJ45-flx-(length) Connection SI-CON8 to A-LAS sensor: 7-pole fem. connector Binder Series 712 Pin: 1 2 3 4 5 6 7 Assignment: GND (0V) +5V I-CONTROL +5V ANALOG (0V ... +5V) not connected GND (0V) Connecting cable*: cab-las-y-(length) or cab-las-y-male-(length) (standard length: 1m, also available lengths: 2m, 3m, 5m) cab-las-y or cab-las-y-male (* cable type depends on type of A-LAS sensor used) Sensor Instruments GmbH • D-94169 Thurmansbang • Schlinding 11 Tel. +49 (0)8544 9719-0 • Fax +49 (0)8544 9719-13 [email protected] • www.sensorinstruments.de (2017-07-10) SI-CON8 / Page 4 of 6 (0628.00) Subject to alteration A-LAS Series • Data Sheet Analog Laser Light Barriers SI-CON8 Connecting Cables Connection of SI-CON8 to PLC: Connecting cable: cab-las8/702-fem-... cab-las8/702-fem-w-... cab-las8/702-fem-... cab-las8/702-fem-w-... Connection of SI-CON8-FIO to PC: Connecting cable: cab-las5/PC-... cab-las5/PC-w-... cab-5/USB-... cab-5/USB-w-... cab-5/ETH-500 cab-las5/PC-... cab-5/USB-... cab-5/ETH-500 (length 0.5m, outer jacket: PUR) 4-pole M12 fem. conn. (D-coded) for connection of an external CAT5 cable, e.g. cab-eth/M12D-RJ45-flx-(length) Connection of SI-CON8 to A-LAS sensor: Connecting cable for A-LAS sensors with 3-pole/4-pole male connector Binder series 712: cab-las-y-... cab-las-y-... Connecting cable for A-LAS sensors with 3-pole/4-pole female connector Binder series 712: cab-las-y-male-... cab-las-y-male-... Sensor Instruments GmbH • D-94169 Thurmansbang • Schlinding 11 Tel. +49 (0)8544 9719-0 • Fax +49 (0)8544 9719-13 [email protected] • www.sensorinstruments.de (2017-07-10) SI-CON8 / Page 5 of 6 (0628.00) Subject to alteration A-LAS Series • Analog Laser Light Barriers Data Sheet SI-CON8 Windows® Software Windows® software SI-CON8-Scope The SI-CON8 control unit can be easily parameterized with the help of the Windows® user interface. For this purpose the SI-CON8 control unit is connected to the PC by way of the cab-las5/PC or cab-5/USB interface cable. When parameterization is finished, the PC can be disconnected again. Windows® user interface: The analog laser light barriers of A-LAS Series can be connected to the electronic control unit SI-CON8. The electronic control unit guarantees a stable voltage supply for the respective transmitte and receiver. The electronic control unit also amplifies and processes the analog signal of the receiver in a suitable manner. A micro-controller performs 12-bit analog/digital conversion of the analog signal, allowing recording and evaluation of the signal characteristics at the sensor. Furthermore the electronic control unit offers various options for intelligent transmitting power control (dirt accumulation compensation) at the sensor. Parameters and measured values can be exchanged between the PC and the electronic control unit through either the RS232 interface or Ethernet interface (by means of an Ethernet adapter). All the parameters can be stored in the non-volatile EEPROM of the electronic control unit through the interface. The SI-CON8-Scope V1.0 Windows software facilitates parameterisation, diagnostics, and adjustment of the sensor system (oscilloscope function). The SI-CON8-Scope V1.0 software furthermore features the function of a data recorder that automatically records data and saves them on the PC's hard disk. The sensor system comprising sensor and electronic control unit is temperature-compensated in a range from 0°C to 80°C. Firmware updates can be easily performed through the RS232 interface even when the sensor system is installed. When parameterisation is finished, the electronic control unit continues to run in STAND-ALONE operation, without a PC. Sensor Instruments GmbH • D-94169 Thurmansbang • Schlinding 11 Tel. +49 (0)8544 9719-0 • Fax +49 (0)8544 9719-13 [email protected] • www.sensorinstruments.de (2017-07-10) SI-CON8 / Page 6 of 6 (0628.00) Subject to alteration