Preview only show first 10 pages with watermark. For full document please download

A00-20-30x42

   EMBED


Share

Transcript

APPLIANCE AND PLUMBING SCHEDULE ITEMS USED/APPLICABLE AND PART OF CONTRACT ITEMS NOT USED - NOT IN CONTRACT ITEMS FOR WHICH CONTRACTOR SHALL PROVIDE CONNECTIONS ONLY AND ARE NOT PART OF CONTRACT ITEMS FOR WHICH CONTRACTOR SHALL PROVIDE AN ALTERNATE BID PLUMBING NOTES 1. E50.1 E50.2 REFRIGERATOR No. 1 - UNDERCOUNTER ULINE UNDERCOUNTER 1175RS-00 RIGHT HAND HINGE,110/115 VOLT, 60 HZ ELECTRICAL WITH 2.4 RUNNING AMPS AND 9.8 MAX. START-UP AMPS, STAINLESS STEEL FINISH, 23-15/16" W x 23-15/16"D x 34-1/8" H 2. REFRIGERATOR No.2: TOP/BOTTOM G.E.ENERGY STAR #GTH21SCXSS STAINLESS STEEL W/STAINLESS STEEL, 21.0 CU FT (120/60 HZ.15A) 32-3/4" W x 32-1/2" D x 66-3/4" H 3. 4. E50.3 REFRIGERATOR No.3: SIDE BY SIDE, 36" WIDE G.E.PROFILE ENERGY STAR #PSDS5YGXSS STAINLESS STEEL W/STAINLESS STEEL, 24.6 CU FT (120/60 HZ.15A) 35-3/4" W x 29-5/8" D x 72-1/8" H E50.4 REFRIGERATOR No.4: SIDE BY SIDE, 48" WIDE SUB-ZERO BI-48 S, 48" STAINLESS STEEL SIDE BY SIDE WITH OUT WATER OR ICE DISPENSER, STAINLESS STEEL TUBULAR BAR HANDLE.115 VOLT, 60 HZ, 15 AMP CIRCUIT. PROVIDE 1/4" COPPER WATER LINE. 48"WX84"X24"D E50.5 E51.1 E51.2 E51.3 PARTITION PLAN NOTES EQUIPMENT SCHEDULE REFRIGERATOR No. 5 - BEVERAGE COOLER, 36" WIDE SUB-ZERO BI-36RG/S/TH GLASS FRONT/STAINLESS STEEL REFRIGERATOR, STAINLESS STEEL TUBULAR BAR HANDLE.115 VOLT, 60 HZ, 15 AMP CIRCUIT. 36"WX84"X24"D. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON THE WORKING DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE DESIGNER OF ANY DISCREPANCIES PRIOR TO COMMENCEMENT OF ANY WORK. IN EVENT OF FAILURE TO DO SO, THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTION OF ANY ERROR. ITEMS USED/APPLICABLE AND PART OF CONTRACT ITEMS NOT USED - NOT IN CONTRACT ITEMS FOR WHICH CONTRACTOR SHALL PROVIDE CONNECTIONS ONLY AND ARE NOT PART OF CONTRACT ITEMS FOR WHICH CONTRACTOR SHALL PROVIDE AN ALTERNATE BID E53.1 E53.2 E53.4 E54.1 E54.2 E54.3 ALL DIMENSIONS SHOWN ARE TO FACE OF DRYWALL (NEW CONSTRUCTION) FINISH AND/OR FACE OF EXISTING WALLS, UNLESS SPECIFICALLY NOTED OTHERWISE. E2.1 FAX MACHINE: STANDARD DESKTOP - 3. ALL DIMENSIONS NOTED "VERIFY" ARE TO BE CHECKED BY CONTRACTOR PRIOR TO CONSTRUCTION ANY VARIANCES ARE TO BE REPORTED TO THE DESIGNER IMMEDIATELY FOR RESOLUTION PRIOR TO CONSTRUCTION. PLUMBING CONTRACTOR'S SCOPE OF WORK IS BASED ON ENGINEERING DRAWINGS, CONTRACTOR TO PROVIDE AND/OR INSTALL THE APPLIANCES & FIXTURES INDICATED. E2.2 SCANNER: STANDARD DESKTOP - 4. CONTRACTOR SHALL NOT SCALE DRAWINGS. ALL DIMENSIONS ON DRAWINGS TAKE PRECEDENCE OVER SCALE. DISCREPANCIES IN DIMENSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER PRIOR TO CONSTRUCTION. CONTRACTOR TO PROVIDE WATER DETECTION DEVICE (E61.1) AT ALL SINK/WET SPOT LOCATIONS. E3.1 PRINTER: STANDARD DESKTOP - 5. ALL PARTITIONS SHALL BE ANCHORED FIRMLY AT BASE AS REQUIRED BY CODE. CONTRACTOR SHALL PROVIDE SEISMIC BRACING TO PARTITIONS AND CEILINGS AS REQUIRED BY CODE. E3.2 PRINTER: STANDARD HIGH SPEED - 6. GLASS DOORS AND/OR GLASS PARTITIONS AT ALL GLAZED OPENINGS WITHIN 18" OF THE ADJACENT FLOOR SHALL BE OF GLASS APPROVED FOR IMPACT HAZARD IN ACCORDANCE WITH CHAPTER 24, UBC STANDARD NO. 24-2, PART I E3.3 PRINTER: STANDARD NETWORK HIGH SPEED COLOR - 7. E3.4 PRINTER: STANDARD COUNTERTOP MULTI-FUNCTION HIGH SPEED - CONTRACTOR TO REPAIR DAMAGED MATERIALS OF EXISTING AREAS AFFECTED BY REMODELING AND ARE EXISTING TO REMAIN AFTER DEMOLITION. PATCH, FILL & PREP FOR SMOOTH FINISH AS REQUIRED FOR PROPER INTERFACE W/NEW CONSTRUCTION AND FINISH. PROVIDE NEW 5/8" TYPE 'X' GYPSUM BOARD WHERE APPLICABLE. 8. CONTRACTOR SHALL COORDINATE WITH MILLWORK CONTRACTOR FOR BACKING AND/OR BLOCKING REQUIREMENTS. CONTRACTOR TO PROVIDE SUBMITTALS FOR A&A'S REVIEW FOR ALL SPECIFIED APPLIANCES & FIXTURES. SUBMITTAL SHALL INCLUDE A FULL AND COMPLETE SCHEDULE OF FIXTURES, INDICATING THE QUANTITY, PART NUMBER INSTALLATION, LOCATION AND FINISH OF EACH ITEM AS NEEDED FOR A COMPLETE AND PROPER INSTALLATION. E3.5 PRINTER: FREE STANDING MULTI-FUNCTION - 9. A FINISH OR FIRE RATING INDICATION ON A WALL SHALL MEAN THE ENTIRE LENGTH OF WALL IS TO BE FINISHED OR FIRE RATED AS INDICATED. E4.1 COPIER: MID-SIZE - ICE MAKER No. 2: UNDERCOUNTER ULINE ADA151M (00 FOR RIGHT HAND, 01 FOR LEFT HAND), NO DRAIN REQUIRED, 110/115 VOLT, 60 HZ, 2.5 AMP, 15"W x 24 7/8"D x 32"H, PROVIDE 1/4" COPPER WATER LINE, STAINLESS STEEL FINISH 10. SEE MILLWORK DRAWINGS AND PLUMBING DRAWINGS FOR LOCATION OF PLUMBING PARTITION REQUIREMENTS TO ACCOMMODATE PLUMBING FIXTURES. E4.2 COPIER: LARGE - 11. ICE MAKER No. 3: FREESTANDING OR UNDERCOUNTER SCOTSMAN CSE60A-1A STAINLESS STEEL (115V, 60 CYCLE, 15A) 18" W x 20-1/4" D x 31-1/4" H WITH DRAIN NOTIFY A&A IMMEDIATELY OF ANY DISCREPANCIES OR ANY WORK AFFECTING THE STRUCTURAL INTEGRITY OF THE BUILDING OR TENANT SPACE BEFORE PROCEEDING WITH THE WORK. E4.3 COPIER: LARGE PRODUCTION - 12. REFER TO ELECTRICAL AND MECHANICAL ENGINEERED DRAWINGS FOR REMOVAL AND REMODEL OF SECONDARY DISTRIBUTION FEED FOR AREA OF NEW CONSTRUCTION. 13. FINISH FLOOR LINE REFERS TO TOP OF CONCRETE SLAB. 14. ALL DOUBLE LAYER GYPSUM BOARD FOR SOUND PARTITIONS TO HAVE STAGGERED JOINTS. 15. CONTRACTOR TO SEAL ALL PENETRATIONS AT RATED CONDITIONS, NEW OR EXISTING, WITHIN THE TENANT SPACE AS REQUIRED TO COMPLY WITH LOCAL BUILDING CODES. 16. CONTRACTOR SHALL PROVIDE, AS INDICATED AT PARTITION TYPES, FIBERGLASS BATT INSULATION BY OWENS/CORNING, FIBERGLASS NOISE BARRIER BATTS, OCF FRICTION FIT BUILDING INSULATION OR APPROVED EQUAL. FIBERGLASS THICKNESS SHALL EQUAL METAL STUD DEPTH. 17. ALL 1/2" REVEALS AT DRYWALL PARTITIONS AND CEILINGS TO BE BY FRY REGLET MOULDING (DRM-50 OR APPROVED EQUAL.) ALL REVEALS AT DOOR FRAMES TO RECEIVE FRY REGLET MOULDING END CAP (DRM 50-25 OR APPROVED EQUAL.) FRY REGLET TEL. (818)289-4744. 18. CONTRACTOR SHALL PROVIDE FIBERGLASS REINFORCED GYPSUM ACCESS PANELS AT DRYWALL CEILINGS AS REQUIRED: PANEL FRAME SHOULD BE TAPED, SPACKLED, AND SANDED SMOOTH TO CEILING AND PANELS SHALL BE FLUSH WITH CEILING. VERIFY EXACT LOCATION ON WITH DESIGNER. 19. CONTRACTOR TO PROVIDE CHALK LAYOUT OF ALL PARTITIONS FOR A&A REVIEW AND APPROVAL. 20. AT SEMI-RECESSED FIRE EXTINGUISHER CABINET CONTRACTOR SHALL PROVIDE POTTER ROEMER ALTA SERIES EXTINGUISHER CABINET 7022-DV. PAINT CABINET TO MATCH THE ADJACENT PARTITION. MOUNT CABINET 36" A.F.F. TO CENTER OF THE CABINET HANDLE. PROVIDE COMPATIBLE FIRE EXTINGUISHER SECURELY MOUNTED IN EACH CABINET AND TEMPORARY EXTINGUISHERS, PER CODE, ON EACH FLOOR. ICE MAKER No. 1 - UNDERCOUNTER HOSHIZAKI C-100BAF-ADDS, WITH DRAIN, 115 VOLT/60 HZ, AAMPS, 14-7/8"W x 22-5/8"D x 31-1/2"H, STAINLESS STEEL FINISH DISHWASHER No. 1: UNDERCOUNTER ASKO LOGIC D5634ADAHS, STAINLESS STEEL, 120V, 60HZ, 15 AMP, 24 W x 22 7/8 D x 32-1/2" TO 34"H MICROWAVE OVEN No.1 G.E. PROFILE SPACEMAKER II, PEM31SMSS, STAINLESS STEEL, (800 WATTS) 23-25/32"W x 12-9/32"D x 11-3/16"H PROVIDE BUILT IN TRIM KIT AS REQUIRED MICROWAVE OVEN No.2 G.E. PROFILE SERIES 2.2 CU. FT., PEB7226SF, STAINLESS STEEL, (1100 WATTS) 24"W x 19-13/32"D x 13-25/32"H, PROVIDE BUILT IN TRIM KIT AS REQUIRED E5 19" OPEN PATCH PANEL RACK - (2) DEDICATED ELECTRICAL OUTLETS. 112BW/ L5-20RS E6 SERVER CABINET/RACK WITH RACK MOUNTED UPS - E7 TELEPHONE SWITCH/PBX CABINET/RACKWITH RACK MOUNTED UPS - E8 UPS (APC) - E9 SECURITY CARD KEY SYSTEM - COMPATIBLE WITH EXISTING. E10.1 HD PROJECTION SCREEN: SMALL, MOTORIZED - A STANDARD TOASTER OVEN No.1 - COFFEE MAKER No.1: LARGE DISPENSER NEWCO ACE-LP (VERIFY PRIOR TO INTALL), GC TO PROVIDE 1/2" FILTERED WATER CONNECTOR, 15.2 AMP, 120/240V 15 1/2"W X 16 3/8"D X 15 7/8"H, NOTE: PROVIDE 3" CLEARANCE ABOVE BREWER FOR HEAT RELEASE COFFEE MAKER No.2: TALL DISPENSER NEWCO ACE-D (VERIFY PRIOR TO INTALL), GC TO PROVIDE 1/2" FILTERED WATER CONNECTOR, 15.2 AMP, 120/240V 8 1/2"W X 17 5/8"D X 26 1/4"H, NOTE: PROVIDE 3" CLEARANCE ABOVE BREWER FOR HEAT RELEASE E10.2 HD PROJECTION SCREEN: MEDIUM, MOTORIZED - E10.3 HD PROJECTION SCREEN: LARGE MOTORIZED - E11 FLAT SCREEN DISPLAY MONITOR/WALL MOUNT TELEVISION - WATER FILTER No.1: HOT/COLD DISPENSER AT SINK - INSIKERATOR F-HC1100, FINISH: ----------------------------------, 2/3 GALLON STAINLESS STEEL TANK/FILTER SST-FLTR,120 V, 6.25 AMP E12 OVERHEAD HD VIDEO PROJECTOR - E55.2 WATER FILTER No.2: REVERSE OSMOSIS EVERPURE MRS-20T SYSTEM: EV9797-92, PROCESSOR - 25"H X 22.5"W X 5"D; TANK - 27"H X 22.5"W X 25"D, FINISH: E13 OVERHEAD PROJECTOR LIFT - E56.1 WATER HEATER No.1: INSTANTANEOUS CHRONOMITE M-20L/277 INSTANT FLOW MICRO-LOW FLOW INSTANTANEOUS HOT WATER HEATER WITH SATIN FINISH STAINLESS STEEL HOUSING, PRESET TEMPERATURE OF 110 DEGREES F, 20 AMP, 277V, 5,540 WATT E14 MOTORIZED ROLL-DOWN WINDOW COVERING - E15 MAIL MACHINE - E56.2 WATER HEATER No.2: FREESTANDING LOWBOY E16 BINDING MACHINE - E17 PAPER SHREDDER - E18 SUPPLEMENTAL 24/7 HVAC SYSTEM WITH WATER LEAK PROTECTION SYSTEM - E57.1 2. COMPUTER: STANDARD PERSONAL COMPUTER WITH MONITOR & CPU COFFEE MAKER No.3: SINGLE CUP BREWER KEURIG B3000SE, 120V, 1400 WATT, 17.4"Hx18"Dx12W, CONTRACTOR TO PROVIDE 1/2" FILTERED WATER CONNECTOR, 17.4"H X 12"W X18"D, NOTE: PROVIDE 3" CLEARANCE ABOVE BREWER FOR HEAT RELEASE E55.1 VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS BY TAKING FIELD MEASUREMENTS, PROPER FIT AND ATTACHMENT OF ALL PARTS IS REQUIRED. BEFORE COMMENCING WORK, CHECK ALL LINES AND LEVELS INDICATED AND SUCH OTHER WORK THAT HAS BEEN COMPLETED. SHOULD THERE BE ANY DISCREPANCIES, IMMEDIATELY REPORT TO THE DESIGNER FOR CORRECTION OR ADJUSTMENT. IN EVENT OF FAILURE TO DO SO, THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTION OF ANY ERRORS. E1 A E52.1 1. Southern California Gas Company Monterey Park Facilities Building 'C' Learning Center 1801 S. Atlantic Blvd. Monterey Park, CA 91754 SINGLE BOWL SINK No.1: BAR SINK, SMALL - E57.2 SINGLE BOWL SINK No.2: BAR SINK, MEDIUM JUST MFG - US - ADA 1818-A, 18 GA. STAINLESS STEEL, 18"L X 18"D. X 4 1/2", SINGLE LEVER FAUCET GROHE ESSENCE 32170 SINGLE SPRAY PULL-OUT, CHROME FINISH, TOP MOUNT SINK FOR P-LAM COUNTER, UNDERMOUNT SINK FOR STONE COUNTER E57.3 DOUBLE BOWL SINK No.1 JUST MFG - US - ADA 1832-A, 18 GA. STAINLESS STEEL, 18"L X 32"D. X 4 1/2", SINGLE LEVER FAUCET GROHE ESSENCE 32170 SINGLE SPRAY PULL-OUT, CHROME FINISH, TOP MOUNT SINK FOR P-LAM COUNTER, UNDERMOUNT SINK FOR STONE COUNTER 57.4 RESTROOM LAVATORY No.1: UNDERCOUNTER RECTANGULAR TOTO LT191 (G), 01 COTTON FINISH, VITREOUS CHINE, 20 1/2" X 12 3/8", RIMLESS, PROVIDE TOTO STANDARD ECOPOWER FAUCET TEL3GS10#CP (THERMAL MIXING), SENSOR OPERATED, SINGLE-HOLE MOUNT, POLISHED CHROME FINISH 57.5 RESTROOM LAVATORY No.2: UNDERCOUNTER OVAL TOTO LT569, 01 COTTON FINISH, VITREOUS CHINE, 19 1/4" X 16 1/4", RIMLESS, PROVIDE TOTO STANDARD ECOPOWER FAUCET TEL3GS10#CP (THERMAL MIXING), SENSOR OPERATED, SINGLE-HOLE MOUNT, POLISHED CHROME FINISH E58.1 GARBAGE DISPOSAL No.1 - INSINKERATOR BADGER 5, 1/2HP MOTOR, 120 V/60HZ, 6.9 AMP E59.1 VENDING MACHINE No. 1: STANDARD BEVERAGE STANDARD 115V, 60HZ, 20 AMPS, SIZE: 36"W X 32"D. X 72"H E59.2 VENDING MACHINE No. 2: BEVERAGE WITH FLOOR SINK PROVIDE FLOOR SINK (1/2" FILTERED WATER CONNECTOR) 115V, 60HZ, 20 AMPS, SIZE: 36"W X 32"D. X 72"H E59.3 VENDING MACHINE No. 3: SNACKS STANDARD 115V, 60HZ, 20 AMPS, SIZE: 36"W X 32"D. X 72"H A REFER TO INTERIOR ELEVATIONS FOR FURTHER INFORMATION. E60.2 GL SODA DISPENSER No. 1: FOUNTAIN DRINKS DORNELIUS VANTAGE POST MIX DISPENSER, 5-FLAVOR, #561600167 (115 VOLTS, 60 HZ, 7.4A) 15"W X 26"D X 21-1/2"H. WATER DETECTION DEVICE WITH LOCAL AUDIBLE ALARM AND WATER SHUT-OFF E62.1 MISC. BREAKROOM EQUIPMENT - GLASS TYPE A - NEW LOW PARTITION A ADDENDUM - A 09/05/2014 GLASS TYPE B - CLEAR GLASS WITH APPLIED FILM: SEE GLASS PARTITION TYPES (A12-10) FOR FURTHER INFORMATION AND GLASS THICKNESS NEW PARTITION WITH HORIZONTAL BRACE VERIFY HEIGHT FOR FURNITURE NEW GLASS PARTITION GL E63.1 WATER CLOSET No. 1: WALL HUNG, ADA COMPLIANTTOTO CT708E WALL MOUNTED TOILET, 1.28 GPF WITH HIGH EFFICIENCY FLUSHOMETER VALVE, ELONGATED BOWL, PROVIDE SEAT, 01 COTTON FINISH E63.3 URINAL No.1: ADA COMPLIANT FALCON F-5000 WATERLESS URINAL WITH SEALED CARTRIDGE, WHITE VITEOUS CHINA C- GLASS TYPE C - FEC BACK-PAINTED CLEAR ANNEALED GLASS WITH : SEE GLASS PARTITION TYPES (A12-10) FOR FURTHER INFORMATION AND GLASS THICKNESS GL D- GLASS TYPE D - MISC. RESTROOM EQUIPMENT - RESTROOM ACCESSORIES - BOBRICK TRIMLINE SERIES, SATIN STAINLESS STEEL FINISH (UON), CONTRACTOR TO PROVIDE SUBMITTALS FOR A&A'S REVIEW FOR ALL SPECIFIED ACCESSORIES FIRE EXTINGUISHER CABINET (SEMI-RECESSED) TYPE C1 - WHITE: PULP STUDIO REF #: LIBP WHITE 06 OR APPROVED EQUAL TYPE C1 - METALLIC: PULP STUDIO REF #: LIBP WHITE METALLIC OR APPROVED EQUAL TYPE C2 - OTHER: -- E- LAMINATED CLEAR GLASS WITH INTERLAYER MEMBRANE: SEE GLASS PARTITION TYPES (A12-10) FOR FURTHER INFORMATION AND GLASS THICKNESS TYPE D1: OBSCURE MEMBRANE, XX% LIGHT TRANSMITTANCE TYPE D2: OBSCURE MEMBRANE, XX% LIGHT TRANSMITTANCE TYPE D3: WHITE MEMBRANE GL E65.1 CLEAR VISION GLASS: SEE GLASS PARTITION TYPES (A12-10) FOR FURTHER INFORMATION AND GLASS THICKNESS TYPE B1 - SAFETY DECAL: 3M TYPE B2 - OBSCURE: 3M 'DUSTED CRYSTAL' OR APPROVED EQUAL TYPE B3 - PATTERNED FILM: 3M A E64.1 EXISTING CONSTRUCTION TO REMAIN NEW PARTITION GL B- SODA DISPENSER No. 2: FOUNTAIN DRINKS MANITOWOC SERVEND #SV-200 SELECTABLE ICE/BEVERAGE DISPENSER WITH ICE CRUSHER AND S500 ICE MACHINE, (120V, 60HZ, APPROX. 12A, NEMA6-20P POWER CORD PROVIDED) 30"W X 31.13"D X 34.88"H E61.1 DATE MM/DD/YYYY ISSUE DESCRIPTION EXISTING CONSTRUCTION TO BE REMOVED AE60.1 PARTITION PLAN LEGEND GLASS SPECIFICATIONS GLASS TYPE E - CLEAR GLASS MIRROR, 1/4" THICK WITH POLISHED EDGES A. RECESSED PAPER TOWEL DISPENSER & TRASH CAN COMBO - B-38034 DRAWN BY: DF B. LIQUID SOAP DISPENSER - B-822 WITH 304 PISTON, SPOUT, AND TOP COVER (BRIGHT POLISHED FINISH) REVIEWED BY: JA/FAA/MHA C. TOILET SEAT COVER DISPENSER - AT WALL: B-3013, AT PARTITION PROJECT NO.: S:\SEM15B\CAD\Sheets SCALE: N.T.S. D. TOILET PAPER DISPENSER - ISSUE: 08/22/2014 E. FEMININE NAPKIN DISPENSERS - F. RECESSED PAPER TOWEL DISPENSER G. 30" WIDE FRAMELESS WITH POLISHED EDGES MIRROR H. 24" WIDE X 44" HIGH FRAMELESS MIRROR W/POLISHED EDGES I. ADA GRAB BAR; ONE - 36"W, ONE - 48"W - B-6806 J. COAT HOOK - AT BACK OF EACH STALL DOOR. (MENS), (WOMENS) E66.1 TOILET AND URINAL PARTITIONS: ADA COMPLIANT METPAR CH700, POWDER SHIELD TOILET ENCLOSURE, CEILING HUNG FINISH: 997 SILVER LAVA. CO E67.1 DRINKING FOUNTAIN No.1: ADA COMPLIANT - ALL DRAWINGS, AND WRITTEN MATERIAL HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF AREF & ASSOCIATES AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF AREF & ASSOCIATES. SHEET TITLE: PARTITION NOTES & LEGENDS, EQUIPMENT, APPLIANCE, & PLUMBING NOTES & SPECIFICATIONS 1 FLOOR NO.: SHEET NO.: A00-20