Transcript
10.3Gb/s XFP Transceiver
Connects fiber to your home
AAPX55HM0xDL40
ATOP Corporation
10.3Gb/s XFP Transceiver APX55HM0xDL40 Product Features
Supports 9.95 to 11.3Gb/s
Duplex LC connector
Hot-pluggable XFP footprint
Cooled 1550nm EML laser
RoHS compliant and Lead Free
40Km link length
Metal enclosure for lower EMI
Built-in dual CDR
+5.0V and +3.3V power supply and power dissipation <2.5W
Applications
SONET OC-192 IR-2/IR-3 SDH STM S-64.2b/S-64.3b
XFP MSA INF-8077I Compliant
ITU-T G.709
10GBASE-ER/EW 10GBASE-ER/EW + FEC
10G Fibre Channel 10G Fibre Channel + FEC
General ATOP’s APX55HM0xDL40 Small Form Factor 10Gb/s XFP transceivers are compatible with XFP MSA Specification. They comply with SONET OC-192 IR-2,OC-192 IR-3,SDH STM S-64.2b,STM S-64.3b as well as with 10G Ethernet 10G BASE-ER/EW per IEEE802.3ae and 40km 10G Fibre Channel applications.
Product Selection Part Number
Operating Case temperature
DDMI
APX55HM0CDL40
Commercial(0~70℃)
Yes
APX55HM0EDL40
Extend(0~85℃)
Yes
APX55HM0IDL40
Industrial(-40~85℃)
Yes
www.atoptechnology.com
Rev1.0
2016-07
Page 1
10.3Gb/s XFP Transceiver
Connects fiber to your home
AAPX55HM0xDL40
ATOP Corporation
Regulatory Compliance
ESD to the Electrical PINs: compatible with MIL-STD-883 Method 3015
ESD to the Duplex LC Receptacle: compatible with IEC 61000-4-2
Immunity compatible with IEC 61000-4-3
EMI compatible with FCC Part 15 Class B EN55022 Class B (CISPR 22B) VCCI Class B
Laser Eye Safety compatible with FDA 21CFR 1040.10 and 1040.11 EN60950, EN (IEC) 60825-1,2
ROHS compliant with ROHS 2 (2011/65/EU)
Pin Descriptions Pin
Symbol
Name/Description
1
GND
Module Ground
2
VEE5
Optional -5.2 Power Supply – Not required
MOD_DESE
Module De-select; When held low allows the module to
L
respond to 2-wire serial interface. LVTTL-I
/INTERRUP
Interrupt; Indicates presence of an important condition which
T
can be read via the 2-wire serial interface. LVTTL-O
Ref.
3
4
2 Transmitter Disable. Logic1 indicates laser output disabled,
5
TX_DIS LVTTL-I
6
VCC5
+5V Power Supply
7
GND
Module Ground
8
VCC3
+3.3V Power Supply
9
VCC3
+3.3V Power Supply
10
SCL
2-Wire Serial Interface Clock. LVTTL-I
2
11
SDA
2-Wire Serial Interface Data Line. LVTTL-I/O
2
12
MOD_Abs
1
Indicates Module is not present. Grounded in the Module. 2 LVTTL-O Module Not Ready; Indicating Module Operational Fault. 13
MOD_NR
2 Open-collector. LVTTL-O
14
RX_LOS
www.atoptechnology.com
Loss of Signal indication. Logic 1 indicates loss of Signal.
Rev1.0
2016-07
2
Page 2
10.3Gb/s XFP Transceiver
Connects fiber to your home
AAPX55HM0xDL40
ATOP Corporation Open-collector. LVTTL-O 15
GND
Module Ground
1
16
GND
Module Ground
1
17
RD-
Receiver Inverted Data Output. CML-O
18
RD+
Receiver Non-Inverted Data Output. CML-O
19
GND
Module Ground
1
20
VCC2
+1.8V Power Supply (Not required).
3
Power down; When high, requires the module to limit power consumption to 1.5W or below. 2-Wire serial interface must be P_DOWN/R
functional in the low power mode. LVTTL-I
ST
Reset; The falling edge initiates a complete reset of the
21 module including the 2-wire serial interface, equivalent to a power cycle. LVTTL-I 22
VCC2
+1.8V Power Supply (Not
required)
3
23
GND
Module Ground
24
REFCLK+
Reference Clock (Not
required)
25
REFCLK-
Reference Clock (Not
required)
26
GND
Module Ground
1
27
GND
Module Ground
1
28
TD-
Transmitter Inverted Data Input. CML-I
29
TD+
Transmitter Non-Inverted Data Input. CML-I
30
GND
Module Ground
1
1
Notes: 1.
Module ground pins GND are isolated from the module case and chassis ground within the module.
2.
Open collector; Should be pulled up with 4.7K-10Kohms to a voltage between 3.15V and 3.6V on the host board.
3.
The pins are open within module.
Pin-out Connector Block on Host Board
www.atoptechnology.com
Rev1.0
2016-07
Page 3
10.3Gb/s XFP Transceiver
Connects fiber to your home
AAPX55HM0xDL40
ATOP Corporation
Pin-out of Connector Block on Host Board
Recommend Circuit Schematic
Absolute Maximum Ratings Parameter
Symbol
Min
Vcc3
Typ
Max
Unit
-0.5
+4.0
V
Vcc5
-0.5
+6.0
V
Storage Temperature
TS
-40
+85
°C
Operating Humidity
RH
0
85
%
www.atoptechnology.com
Rev1.0
Ref.
Maximum Supply Voltage
2016-07
Page 4
10.3Gb/s XFP Transceiver
Connects fiber to your home
AAPX55HM0xDL40
ATOP Corporation
Recommended Operating Conditions Parameter
Symbol
Min
Typ
Max
Unit
Vcc3
3.13
3.30
3.47
V
Vcc5
4.75
5.0
5.25
V
Icc3
600
mA
Icc5
100
mA
Ref.
Power Supply Voltage
Power Supply Current
Case Operating Temperature
Bit Rate 9/125um G.652 SMF
Tc
0
+70
Te
0
+85
TI
-40
+85
Br
9.95
11.3
Gbps
40
km
Lmax
Commercial °C
Extend Industrial
Electrical Characteristics (TOP=25°C, Vcc=3.3Volts) Parameter
Symbol
Min
Typ
Max
Unit
Ref.
Input differential impedance
Rin
80
100
120
Ω
1
Differential data input swing
Vin, pp
120
850
mV
TX Disable-High
Vcc – 0.8
Vcc
V
TX Disable-Low
Vee
Vee+ 0.8
V
TX Fault-High
Vcc-0.8
Vcc
V
TX Fault-Low
Vee
Vee+0.8
V
Vout, pp
300
850
mV
2
Data output rise time
Tr
30
ps
3
Data output fall time
Tf
30
ps
3
Transmitter
Receiver Single ended data output swing
LOS-High
Vcc – 0.8
Vcc
V
LOS-Low
Vee
Vee+0.8
V
Notes: 1.
AC coupled.
www.atoptechnology.com
Rev1.0
2016-07
Page 5
10.3Gb/s XFP Transceiver
Connects fiber to your home
AAPX55HM0xDL40
ATOP Corporation 2.
Into 100 ohm differential termination.
3.
20 – 80 %
Optical Characteristics (TOP=25°C, Vcc=3.3 Volts) Parameter
Symbol
Min
Output Opt. Power
PO
Optical Wavelength
Typ
Max
Unit
-1
4
dBm
λ
1530
1565
nm
SMSR
30
Ref.
Transmitter
Side-Mode Suppression Ratio
σ
RMS Spectral Width(-20dB)
1
nm
-
dB
Optical Extinction Ratio
ER
SONET Tx Jitter Generation(peak-to-peak)
Txj
0.1
UI
3
Txjrms
0.01
UI
4
2
dB
RIN
-128
dB/Hz
SENS
-16
dBm
Tx jitter Generation(RMS)
8.2
dB
Path penalty at 800ps/
[email protected]/s Relative Intensity Noise Receiver RX Sensitivity @10.3 Gb/s Receiver Overload
-1 λC
Optical Center Wavelength
1260
dBm 1600
nm
-20
dBm
LOS De-Assert
LOSD
LOS Assert
LOSA
-34
dBm
-
0.5
dB
LOS Hysteresis
1,2
Notes: 1. Measured with conformance signals defined in FC-PI-2 Rev. 10.0 specifications. 31
2. Measured with PRBS 2 -1 at 10
-12
BER.
3. Measured with a host jitter of 50 mUI peak-to-peak per Telcordia GR-253 4. Measured with a host jitter of 7 mUI RMS.
Mechanical Specifications
www.atoptechnology.com
Rev1.0
2016-07
Page 6
10.3Gb/s XFP Transceiver
Connects fiber to your home
AAPX55HM0xDL40
ATOP Corporation
APX55HM0xDL40
EEPROM Information EEPROM memory map specific data field description is as below:
Digital Diagnostic Monitoring Interface Five transceiver parameter values are monitored. The following table defines the monitored parameter’s accuracy.
Parameter
www.atoptechnology.com
Range
Rev1.0
Accuracy
2016-07
Calibration
Page 7
10.3Gb/s XFP Transceiver
Connects fiber to your home
AAPX55HM0xDL40
ATOP Corporation 0 to +70°C (C) Temperature
0 to +85°C (E)
±3°C
Internal
2.97 to 3.63V
±3%
Internal
Bias Current
0 to 100mA
±10%
Internal
TX Power
-1 to 4dBm
±3dB
Internal
RX Power
-16 to -1dBm
±3dB
Internal
-40 to +85°C (I) Voltage
Revision History Revision V1.0
Initiated xiaoaiyou
Reviewed wanggang
Approved
DCN New Released.
Release Date July 28, 2016
For More Information ATOP Corporation Tel:
+86-755-86674946
Fax:
+86-755-86296723
Email:
[email protected] Web:
www.atoptechnology.com
www.atoptechnology.com
Rev1.0
2016-07
Page 8