Preview only show first 10 pages with watermark. For full document please download

Aaua96tlav - Teamfujitsuvrf.com

   EMBED


Share

Transcript

Variable Refrigerant Flow System Submittal Data: AAUA96TLAV Inverter Driven Heat Pump 96,000 BTU Ducted Heat-Pump System Job Name:______________________________ Date:_______________________________ Location:_______________________________ Approval:____________________________ Engineer:_______________________________ Construction:_________________________ Submitted to:____________________________ Unit #:______________________________ Submitted by:___________________________ Drawing #:___________________________ Reference:______________________________ General Features: •Refrigerant Type R410A. •New style high power DC fan motor. •Wired and wireless remote controllers and web monitoring available. •Wide range of selectable static pressures. 0.20–0.96 in. WG (50-240Pa) •5- Years Parts, 7-Years Compressor Warranty (See Warranty Statement for details.) •Extensive training for Engineers, Architects, Contactors, and distributors. •Powerful output in even compact designs. Electrical …………………………………………...………. 208 / 230 1ph-60HZ Available Voltage Range……………………..……..….………..… 187 / 253 VAC Minimum Circuit Ampacity………………………………….....……........… 3.35A Max Circuit Breaker…………………………………....................................… 15A Input Power….…………………………………....…………...………........... 370W Current………………………………………………...……..…...…….......... 2.23A Dimensions HxWxD Uncrated in. (mm)…...................…. 17-11/16 x 62-5/16 x 27-9/16 (450x1583x700) Crated in. (mm)…………….………..... 20-1/2 x 68-11/16 x 32-/8 (520x1745x823) Piping Dimensions Liquid (High Pressure)…………………………..….……..… 1/2” / 12.70mm Flare Gas (Low Pressure)………………………..…..…….………. 7/8” / 22.22mm Flare Cooling………………………………………...……………………... 96,000 Btu/h Drainpipe………………………………....…………...…….. 3/4”(ID) 1-1/16”(OD) kW………………………………………………...…….……………………..…. 28 Weight Heating………………………………………………...…………....… 59,000 Btu/h Net…………………..…………………………….…….….............. 159 lbs (72 kg) kW………………………………………………………………...………….… 17.4 Gross………………..…….………………….……...…….………... 194 lbs (88 kg) Capacity Temperature Setting Range Cooling……………………………………...…...…..…. 64°F - 88°F (17°C - 31°C) Heating……………………………………...…………... 48°F – 88°F (8°C - 31°C) Remote Control Type………………………………………. Wired or Wireless Fan Motor Type: DC ………………………………………….………....……….... Sirocco x 1 Airflow Rate…………………………………………...…. 1,236 CFM (2100 m3/h) Motor Output……………………………………………………………... 700W x1 Available Controllers Individual Controllers Group Controllers Thermal Protector Off……………………………...……........................... 212+ 27 -18 ° F (100 +15 -10 °C) On……………………………………..…….……............ 203°+ 27 -18 F (95° +15 -10 C) Sound Pressure…………………….…...……....…...………..… 47 dB(A) Heat Exchanger Length………………………….……….….............………. 42-15/16 in. (1090mm) Fin Pitch……………………………………...…..……..………………….... 20 FPI Rows x Stages…………………………………....………...……...….…...…. 4 x 18 Face Area…………………………………………...….....……….... 5.1ft.² (0.47m²) Pipe Type (Material)………....………………...……....… Grooved H-Pin (Copper) Type (Material)……………………………...……...…..…...……. Slit (Aluminum) Surface Treatment……………………………....…..…...……. Hydrophilic Coating Note: Specifications are based on the following conditions. Cooling: Outdoor temperature of 91°F (33°C) DB / 82°F (28°C) WB. Heating: Outdoor temperature of 32°F (0°C) DB / 27°F (-2.9°C) WB. Pipe length: 25f t.(7.5 m); Height difference between outdoor unit and indoor unit: 0 ft. (0 m). Wired Remote UTY-RNKU Simple Wired Remotes: UTY-RSKU UTY-RHKU UTY-LNHU UTB-YWC (IR Receiver Unit Req’d) UTY-DCGY UTY-DTGY UTY-APGX UTY-ALGX Service Tool & Web Monitor UTY-AMGX 1 of 3 UTY-ASGX Fujitsu General America, Inc. 353 Route 46 West Fairfield, NJ 07004 Toll Free: 1-888-888-3424 Fax: (973) 836-0447 www.airstagevrf.com Variable Refrigerant Flow System Dimensions: AAUA96TLAV 2 of 3 1 Liquid line 2 Gas line 3 Drain line Fujitsu General America, Inc. 353 Route 46 West Fairfield, NJ 07004 Toll Free: 1-888-888-3424 Fax: (973) 836-0447 www.airstagevrf.com Variable Refrigerant Flow System Dimensions: AAUA96TLAV 3 of 3 Fujitsu General America, Inc. 353 Route 46 West Fairfield, NJ 07004 Toll Free: 1-888-888-3424 Fax: (973) 836-0447 www.airstagevrf.com