Abc Ant - Rf Solutions

   EMBED


Share

Transcript

     ANT POWER SYNC C RELAY 1 RELAY 2 RELAY 3 RELAY 4 ERASE TIMER SELECT  SIGNAL TEST RELAY 3 FUSE RELAY 2 FUSE FUSE FUSE RELAY 1  RELAY 4 FUSE   Fig 1.1 B A   LOAD 230V INPUT SUPPLY    QS-ELITE-1 Sync/Pair Button – Press once to auto pair. See Advanced operation for other pairing options. Status LEDs– Flash when signals are sent/received Erase Button – Press and hold to erase all pairings, see advanced operation for individual erase Timer Select Button – Used to select timer mode Mag sync – Touch a magnet to the plastic case in the cross hatched area to replicate the sync button on board without opening the case Signal Test mode – Press to enter signal test mode Momentary/Latching Jumper Links – It is possible to set the relay switches on the ELITE receiver to either momentary or latching operation. Latching (link fitted) - One press for on, one press for off. Momentary (link removed) - On while button is held only. To set a relay switch to either momentary/latching choose the associated link cap. NOTE: If link is changed, power cycle the receiver (turn off/on) otherwise it will stay in the same mode it was previously set in. POWER RELAY 1 RELAY 2 RELAY 3 RELAY 4 SYNC 8 ERASE 7 TIMER 6 TEST 5 4 RELAY 3 FUSE RELAY 2 FUSE FUSE FUSE RELAY 1 3 RELAY 4 2 FUSE L N 1 E L N E L N E L N E L N E Relay switch terminals: Output Fuses must be 4A (Slow blow fuses recommended) 230Vac power input Earth Neutral Live Power input fuse – must be 500mA (Fast blow fuse recommended)