Preview only show first 10 pages with watermark. For full document please download

Abcd 1 2 3 4 5 6 Abcd 1 2 3 4 5 6 Max.835 L6 D6=max.1025 D5

   EMBED


Share

Transcript

1 2 Ansicht A View A 44x8.18 $ 3 4 Bestellschluessel / ordering key (x) 24 Schluessel L6 Key (x) 0 1 3 0 100 300 5 Bestellschluessel / ordering key (y) L16 L Masse ca. Weight approx. 140 875 362 kg 1 braun / brown 440 1175 436 kg 2 grau / gray 240 975 MICAFIL HIRIP Hochstromdurchfuehrung fuer Transformatoren (RIP) Transformer high current bushing (RIP) Schluessel Porzellan Farbe (y) Key Porcelain color 387 kg Technische Daten Technical Data 1 Variante 2 / option 2 7.5 $ 30 25.4 44.5 85 U 22 kV Pruefwechselspannung - trocken / nass 77/70 kV AC test voltage - dry / wet 80/75 kV Blitzstossspannung Lightning impulse voltage 170 kV 200 kV Teilentladung <5 pC bei Partial discharge <5 pC at 42 kV 44 kV Messanschluss - Pruefwechselspannung Test tap - AC test voltage Variante 2 / option 2 NC U 44.45 550 25.4 1 100 " /2 B -2 siehe HLJK014654 see HLJK014654 Porzellan / Porcelain Fadenmass min. Arcing distance min. 310 mm Kriechweg min. Creepage distance min. 1080 mm Trockenfuellung Micagel / Dry filling Micagel Umgebungstemperatur Ambient temperature siehe HLJK014654 see HLJK014654 Pruefbiegelast 1 min. Cantilever test load 1 min. Montage Installation C 5000 N max 1000 m. ΓΌ. M. senkrecht bis horizontal max 1000 m. a.s.l. vertical to horizontal Bestellschluessel / ordering key: 1ZCD061892R0xyz L6 Anschluss / terminal Porzellan Farbe / porcelain color 22 D3 D 5 30 $ 19 90 $ Comments Order - - Prepared Based on Reviewed Responsible department Approved Part lifecycle state 2011-10-24 D. Lazarevic 2011-10-24 D. Lazarevic 2011-10-24 A. Dais Scale 3:50 3 4 Units mm Format A3 - - Language PPHV/CHABB/PTMD EN Page RTXF_36-200/37000 OBSOLESCENCE 1 of 1 Revision 1ZCD061892 ABB Technology Ltd. 2 B 100 kA We reserve all rights in this document and in the information contained Document id. therein. Reproduction, use or disclosure to third parties without express authority is strictly fobidden. Copyright 2010 ABB 1 A 3 kV Thermischer Kurzzeitstrom 2 s Rated thermal short time current 2 sec. 44.5 550 21 kV Maximaler Betriebsstrom Max. rated current 85 20 50 12 19 D3=9 358 2" 1/ 53 2B NC Ansicht B View B $ D4=990 M Aluminium, versilbert Aluminium, silver plated 5 x1 D Variante 1 / option 1 20 B 24 Erdung, Gewinde 2xM12 Grounding thread $ 45 40 D6=max.1025 max.835 Oel Seite Oil side 2 M1 53 40 C D5=max.905 L6 Geerdete Laenge Grounded length 249 L16 L L2=486 Messanschluss Measuring tap B 131 Luft Seite Air side A 20 768 Aluminium, versilbert Aluminium, silver plated 34.5 kV Maximale Phase-Erde-Spannung Rated max. line to ground voltage Variante 1 / option 1 2 36 kV Systemspannung System voltage Anschluss (z) Terminal 100 A IEEE IEC 60137 C57.19.01 (2008) (2000) Maximale Spannung (50Hz/60Hz) Maximum voltage Bestellschluessel / ordering key (z) Schluessel Key 6 5 AG 6 Pro/Engineer-Drawing