Preview only show first 10 pages with watermark. For full document please download

Abq-a_databook_ang

   EMBED


Share

Transcript

Air Conditioning Technical Data Concealed ceiling unit EEDEN13-131 ABQ-A • Indoor Unit • Concealed ceiling unit • ABQ-A TABLE OF CONTENTS ABQ-A 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety device settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3 Safety Device Settings 4 5 Piping diagrams Piping Diagrams 6 ...... .......... .......... .......... .......... . 4 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensional Drawings ........... .......... .......... .......... .......... . 6 . ........... .......... .......... .......... .......... . 6 Wiring diagrams ........... .......... .......... .......... .......... . 7 ..... .......... .......... .......... . 7 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sound Pressure Spectrum 8 Fan Characteristics 8 .. .......... .......... .......... .......... . 8 Fan characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Split - Sky Air • Indoor Unit 5 ...... .......... .......... .......... .......... . 5 Wiring Diagrams - Single Phase 7 3 9 ......... .......... .......... .......... .......... . 9 1 • Indoor Unit • Concealed ceiling unit • ABQ-A 1 tkc iS nd U-e l r at oeAi oc- dl Qn npBo •ISAC • Features Ideal solution for shops, restaurants or offices requiring maximum floor space for furniture, decorations and fittings Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible 1 1 2 • Split - Sky Air • Indoor Unit • Compact dimensions, can easily be mounted in a narrow ceiling void • Air filter removes airborne dust particles to ensure a steady supply of clean air • Easy installation and maintenance • Indoor Unit • Concealed ceiling unit • ABQ-A 2 Specifications 2-1 Technical Specifications Dimensions Unit Packed unit Weight Packing Fan Unit Packed unit Material Air flow rate External static pressure Fan motor Drive Speed Sound power level Cooling Sound pressure level Heating Cooling Heating Refrigerant Piping connections Type Liquid Gas Height/Width/ Depth Height/Width/ Depth AB Q125 A ABQ1 40A mm 378/1,388/541 378/1,588/541 mm 415/1,497/631 415/1,701/631 kg kg 50.0 54.0 56.0 62.0 cfm 1,430 1,720 cfm cfm cfm cfm 1,320 1,230 1,130 1,430 1,550 1,340 1,170 1,720 cfm cfm cfm Pa Pa Pa Pa 1,320 1,230 1,130 1,550 1,340 1,170 rpm 1,320/1,230/1,130 1,245/1,085/975 rpm 1,320/1,230/1,130 1,245/1,085/975 dBA 78/76/73/70 79/78/75/71 dBA dBA 76/73/70 53/52/50/47 78/75/71 55/53/50/47 dBA -/52/50/47 -/53/50/47 Cur rent 1 2 Car ton / EPS- Foam / strap Cooling Super high High Nom. Low Heating Super high High Nom. Low Super high High Nom. Low 147 126 109 92 120 90 69 Direct drive Cooling High/ Mediu m/Low Heating High/ Mediu m/Low Super high/High/ Nom./Low High/Nom./Low Super high/High/ Nom./Low Super high/High/ Nom./Low R-410A 9.52 15.88 OD OD 2-2 Electrical Specifications Power supply 3 AB Q125 A Name Phase Frequency Voltage Nominal running Cooling current (RLA) - 50Hz Heating Hz V A A • Split - Sky Air • Indoor Unit ABQ1 40A V1 1~ 50 230 1.74 1.74 2.42 2.42 3 • Indoor Unit • Concealed ceiling unit • ABQ-A 3 Safety device settings 3-1 Safety Device Settings 1 3 4 • Split - Sky Air • Indoor Unit • Indoor Unit • Concealed ceiling unit • ABQ-A 4 Dimensional drawings 4-1 Dimensional Drawings 3 1 4 • Split - Sky Air • Indoor Unit 5 • Indoor Unit • Concealed ceiling unit • ABQ-A 5 Piping diagrams 5-1 Piping Diagrams 1 5 6 • Split - Sky Air • Indoor Unit • Indoor Unit • Concealed ceiling unit • ABQ-A 6 Wiring diagrams 6-1 Wiring Diagrams - Single Phase 3 1 6 • Split - Sky Air • Indoor Unit 7 • Indoor Unit • Concealed ceiling unit • ABQ-A 7 Sound data 7-1 Sound Pressure Spectrum 1 7 8 • Split - Sky Air • Indoor Unit • Indoor Unit • Concealed ceiling unit • ABQ-A 8 Fan characteristics 8-1 Fan Characteristics 3 1 8 • Split - Sky Air • Indoor Unit 9 • Indoor Unit • Concealed ceiling unit • ABQ-A 8 Fan characteristics 8-1 Fan Characteristics 1 8 10 • Split - Sky Air • Indoor Unit The present leaflet is drawn up by way of inf ormati on only and does not const itut e an of fer binding upon Daikin Europe N.V .. Daikin Europe N.V . has compiled the content of t his l eaf let t o the best of it s knowl edge. No express or i mplied warranty is given f or t he completeness, accuracy, reliability or fit ness f or parti cular purpose of its content and t he product s and services present ed therein. Specifications are subject t o change without prior not ice. Dai kin E urope N.V. expl icit ly rejects any liabi lity f or any direct or indirect damage, in the broadest sense, arising from or related t o t he use and/or int erpret ation of t hi s leaf let. Al l cont ent i s copyright ed by Daikin E urope N.V. Daikin Europe N. V. participat es in the Eurovent Cert ification programme for Air conditioners (AC), Liquid Chill ing Packages (LCP) and Fan coil unit s (FCU), Check ongoing validity of certifi cate online: www.eurovent -cert ificat ion.com or usi ng: www.certif lash.com” BARCODE Daikin products are dist ributed by: N aamloze Ve nnootschap - Z andvoordestraa t 30 0, B-8400 Oostend e - Be lgium - w ww.d aikin.eu - BE 0412 120 336 - R PR Ooste nde EED EN13 -131 • 0 1/13 • Cop yrigh t Da ikin The p resen t pu bli cation su perse des EEDEN 12-1 31 Daikin’s unique posit ion as a m anufact urer of air condit ioning equipment, com pressors and refrigerants has led to it s close involvement in environment al issues. For several years Daikin has had the int enti on to become a leader i n the provision of products that have limit ed i mpact on the environment. This chall enge demands t he eco desi gn and development of a wide range of products and an energy m anagement system, resulting in energy conservat ion and a reduct ion of waste.