Preview only show first 10 pages with watermark. For full document please download

Absorbent Glass Mat (agm) Technology For Superior • Performance

   EMBED


Share

Transcript

12 Volt 100.0 AH PS-121000 Features • Absorbent Glass Mat (AGM) technology for superior performance • Valve regulated, spill proof construction allows safe operation in any position • Power/volume ratio yielding unrivaled energy density • Rugged impact resistant ABS case and cover (UL94-HB) • Integrated ABS carrying handles for ease of movement • Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and &$%FHUWLÀHG • 8/UHFRJQL]HGXQGHUÀOHQXPEHU0+ Terminals 3HUIRUPDQFH6SHFLÀFDWLRQV (mm) Positive Terminal 10 10 9 8.5 22 18 9 13 22 8.5 Nominal Capacity 15.9 18 • U: Universal terminals: Heavy-duty posts with ‘nut & bolt’ fasteners Nominal Voltage ........................................................................ 12 volts (6 cells) Negative Terminal 17.4 13 Physical Dimensions: in (mm)  KU $WRYROWV  ............................................................. 100.0 AH  KU $WRYROWV  ............................................................ 92.0 AH  KU $WRYROWV  .......................................................... 79.0 AH  KU $WRYROWV  ............................................................ $+  PLQ $WRYROWV ............................................................... 43.8 AH Approximate Weight ...................................................... 68.00 lbs. (30.84 kg) Energy Density (20-hr. rate) .............................. :KLQ :KO 6SHFLÀF(QHUJ\ (20-hr. rate) .............................. :KOE :KNJ Internal Resistance (approx.) ........................................................ PLOOLRKPV W Max Discharge Current (7 Min.) ............................................. 300.0 amperes Max Short-Duration Discharge Current (7 Sec.) ..................DPSHUHV Shelf Life (% of nominal capacity at 68°F (20°C)) 1 Month ...................................................................................................... 97% Sealed Rechargeable Battery HT H MODEL PS-121000 U 12 Volt 100.0 Amp. Hr. T TE RY BA Pb YCL ED EC ST B E R MU ® MH20845 www.power-sonic.com NONSPILLABLE L 3 Months ..................................................................................................... 91% 6 Months .................................................................................................... 83% Operating Temperature Range Charge .. ........................................................... ƒ) ƒ& WRƒ) ƒ& Discharge ....................................................... -40°F (-40°C) to 140°F (60°C) L:  W: 6.60 (168) H:  HT: 8.98 (228) Case ...................................................................................................... ABS Plastic Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. Power-Sonic Chargers ............................................................PSC-1210000A-C 7RHQVXUHVDIHDQGHI¿FLHQWRSHUDWLRQDOZD\VUHIHUWRWKHODWHVWHGLWLRQRIRXU7HFKQLFDO0DQXDODVSXEOLVKHGRQRXUZHEVLWH $OOGDWDVXEMHFWWRFKDQJHZLWKRXWQRWLFH www.power-sonic.com PS-121000 12 Volt 100.0 AH Constant Power Discharge Ratings MODEL WATTS PER CELL @ 25° C FINAL VOLTAGE 5 MIN 10 MIN 15 MIN 20 MIN 30 MIN 45 MIN 60 MIN    312 267 207  128 1.70  413 324 277 212  129 1.67  421 330 283   130 PS-121000 Discharge Characteristics Discharge Time vs. Discharge Current 14.0 Terminal Voltage (V) h o 13.0 5 Discharge Time o Ambient Temperature 20 C (68 F) 20 15 10 Final Voltage 10.5V 2 10.2V 1 12.0 11.0 10.0 50 9.0 Final Voltage 9.6V 30 min 8.0 9.0V o 5 1.2 o 40 C (104 F) o o 20 C (68 F) o o 0 C (32 F) 10 100 200 2.4 6 12 10 20 50 100 200 “Float” or “Stand-By” Service: Hold battery across constant voltage source of WRYROWVFRQWLQXRXVO\:KHQKHOGDWWKLVYROWDJHWKHEDWWHU\ZLOOVHHNLWV own current level and maintain itself in a fully charged condition. Note: Due to the self-discharge characteristics of this type of battery, it is imperative that they be charged within 6 months of storage, otherwise permanent loss of capacity might occur as a result of sulfation. Chargers 4 6 8 10 20 4 0 h Shelf Life & Storage Capacity Retention Ratio (%) Cycle Applications: Limit initial current to 20A. Charge until battery voltage (under charge) reaches 14.4 to 14.7 volts at 68°F (20°C). Hold at 14.4 to 14.7 volts until current drops to under 1A. Battery is fully charged under these FRQGLWLRQVDQGFKDUJHUVKRXOGEHGLVFRQQHFWHGRUVZLWFKHGWR´ÁRDWµYROWDJH 2 Discharge Time Discharge Current (A) Charging 24 36 48 1 min 8.1V 5.0 5.0 10 20 100 Charging is not necessary unless 100% of capacity is required. 80 Charging before use is necessary to help recover full capacity. 5oC (41oF) 60 40 0 o 40oC (104oF) 0 2 4 6 30 C o (86 F) 8 10 Charge may fail to restore full capacity. Do not let batteries reach this state. 20oC (68oF) 12 14 16 18 20 Standing Period (Months) Further Information Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. 3OHDVHUHIHUWRWKH&KDUJHU6HOHFWLRQ*XLGHLQRXUVSHFLÀFDWLRQVKHHWVIRU´&6HULHV 6ZLWFK0RGH&KDUJHUVµDQG´7UDQVIRUPHU7\SH$DQG)6HULHVµ3OHDVHFRQWDFWRXU 7HFKQLFDOGHSDUWPHQWIRUDGYLFHLI\RXKDYHGLIÀFXOW\LQORFDWLQJVXLWDEOHPRGHOV Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material safety data sheets (MSDS), ISO FHUWLÀFDWLRQHWF Contact Information DOMESTIC SALES Tel: +1-619-661-2020 )D[ [email protected] www.power-sonic.com CUSTOMER SERVICE Tel: +1-619-661-2030 Fax: +1-619-661-3648 [email protected] TECHNICAL SUPPORT Tel: +1-619-661-2020 Fax: +1-619-661-3648 [email protected] INTERNATIONAL SALES 7HO )D[ [email protected] CORPORATE OFFICE • 3DQDVRQLF:D\‡6DQ'LHJR&$‡86$‡7HO‡)D[ 408 1M