Transcript
Model No.
AC/DC/IR/SCAN Hipot Tester GPIB
RS-232
RS-422
9055/9056/9056-20kV
SCANNER
ORDERING INFORMATION
■ Key lock & test data protection ■ Optional 8 channels scanner (AC: 5kV max.) ■ Standard RS-232 interface ■ Optional GPIB, SCANNER, RS-422 Interface
Programmable Auto Safety Tester Model 9055/ 9056/ 9056-20kV KEY FEATURES ■ Programmable output voltage to 10kV ac (9055 only) ■ Programmable output voltage to 12kV dc (9056 only) and 20kV dc (9056-20kV only) ■ 50 internal instrument setups with 10 steps per setup ■ Electronic Fast discharge ■ ARC detection (Flashover) SPECIFICATIONS Model Mode Withstanding Voltage Test Output Voltage Load Regulation Voltage Resolution Voltage Accuracy Cutoff Current Current Resolution Current Accuracy Current Frequency Test Time Ramp up Time Waveform Insulation Resistance Test Output Voltage Voltage Resolution Voltage Accuracy IR Range Resistance Resolution Resistance Accuracy ARC Detection (Flashover) Setting Mode Detection Current Minimum Pulse Width Secure Protection Function Fast Output Cut-Off Panel Operation Lock Power on Data Rally GO/NG Judgment Window Indication, Alarm Data Hold Step Hold Memory Storage Remote Connector Real Panel 9 pin D-type connector General Operation Environment Power Consumption Power Requirement Dimension (H x W x D) Weight
13-11
The 9055/9056/9056-20kV are the Hipot Testers in super high voltage series. It is suitable for electronic products hi-pot test with super high voltage output. 9055 and 9056 are able to supply 10kV and 12kV/10mA output power, while 9056-20kV can supply super output power up to 20kV/5mA. Working with the optional 8 sets high voltage scanner box (A190301), it can perform super high voltage transformer safety test and is the best selection for high voltage output safety test.
9055 : Programmable Auto Safety Tester (AC) 9056 : Programmable Auto Safety Tester 12kV (DC/IR) 9056-20kV : Programmable Auto Safety Tester 20kV (DC/IR) A190301 : 8HV Scanning Box A190321 : GPIB Interface A190506 : RS-422 Interface A190507 : SCANNER Interface A190344 : HV Gun A190708 : ARC Verification Fixture
9055 AC
9056 DC/IR
9056-20kV DC/IR
AC : 0.1 ~ 10kV 1% + 10V 10V 1%+10counts AC : 20mA 1μA 1% + 5 counts 50Hz/ 60Hz
DC : 0.1 ~ 12kV 1 % + 10V 10 V 1 % + 5 counts DC : 10mA 0.1μA 1 % + 5 counts -0.3 ~ 999 sec, continue 0.1 ~ 999 sec, continue
DC : 0.1 ~ 20kV 1.5 % + 20V 10 V 1.5 % + 5 counts DC : 5mA 0.1μA 1 % + 5 counts --
Sine Wave
--
-------
DC : 0.1 ~ 1 kV 10V 5% + 5V 1MΩ ~ 50 GΩ 0.1MΩ 5% typical
1 ~ 20mA
Programmable setting 1 ~ 10mA 10 us approx.
1 ~ 5mA
0.4 ms after NG happen Present password Yes GO: Short sound; NG: Long sound Least tests data memories Step signal trigger ON / OFF 10 steps with 50 groups recall Input : Start, Stop, Interlock(at 11 pin terminal block only); Output : under test, Pass, Fail Temperature: 0℃ ~ 40 ℃, Humidity: ≦ 80 % RH No load : <100 W, With rated load : ≦ 500 W 100V / 120V / 220V / 240V, 50 / 60 Hz 133 x 430 x 440 mm / 5.24 x 16.93 x 17.32 inch 19 kg / 41.85 lbs
28 kg / 61.67 lbs
All specifications are subject to change without notice.