Preview only show first 10 pages with watermark. For full document please download

Ac Rectangular Fg Series Photoelectric Sensors Tech Specs

   EMBED


Share

Transcript

Prices as of October 22, 2014. Check Web site for most current prices. FG Series Photoelectric Sensors Rectangular plastic - AC/DC • Universal supply voltage: 12-240 VDC or 24-240 VAC • Diffuse w/background suppression and through-beam models • Plastic housing • SPDT electrically isolated output • Adjustable sensitivity • IP67 rated FG Series Photoelectric Sensors Selection Chart Part Number Price Sensing Range Diffuse with background suppression $104.00 up to 550mm (21.65in) FGRW-DT-0A Through-beam* $108.00 up to 20m (65.62ft) FGRHD-DT-0A Output Connection Wiring Dimensions Characteristic Curves SPDT Relay 2m (6.5) axial cable Diagram 1 Figure 1 Chart 1 SPDT Relay 2m (6.5) axial cable Diagram 1 and 2 Figure 2 Chart 2 *Through-beam model consists of an emitter and receiver pair. Switching Element Function Reflective Thru-beam Models Diffuse Models Light on N.C. Dark on N.O. N.O. N.C. Wiring diagrams Diagram 1 Diagram 2 Emitter Dimensions (mm) Figure 1 Figure 2 1) Emitter center of optical axis 2) Receiver center of optical axis Book 2 (14.1) ePH-78 Photoelectric Sensors 1-800-633-0405 Prices as of October 22, 2014. Check Web site for most current prices. FG Series Photoelectric Sensors Specifications Diffuse Models Type Sensing Distance Light Spot Diameter Emission Sensitivity Output Type Operating Voltage No-load Supply Current Operating (Load) Current Off-state (Leakage) Current Voltage Drop Switching Frequency Ripple Time Delay before Availability (tv) Short-Circuit Protection Operating Temperature Protection Degree (DIN 40050) LED Indicators - Switching Status Housing Material Lens Material Shock/Vibration Tightening Torque Weight Connectors Agency Approvals Company Information Through-Beam Models Diffuse reflection Through-beam 550mm1 20m – 1.5m @ 20m Drives 2 Soft Starters Motors Red LED (visable) Power Transmission Adjustable SPDT relay electrically isolated Motion: Servos and Steppers 12-240VDC or 24-240VAC Motor Controls m2VA 3A @ 240VAC/30VDC Sensors: Proximity – – Sensors: Photoelectric 33Hz – Sensors: Encoders 150 ms Sensors: Limit Switches Yes, switch autoresets after load is removed -25 to 55°C (-13° to 131° F) Sensors: Current IEC IP67 Red LED - Switching status Sensors: Pressure ABS Polycarbonate (PC) Sensors: Temperature See terminology section N/A 160g (5.64oz) Sensors: Level Emitter/Receiver pair 290g(10.23oz) 2m (6.5’) axial cable Sensors: Flow Switches UL Recognized E224302, CE Pushbuttons and Lights 1With 100x100mm white matte paper 2Each through-beam part number consists of an emitter and receiver pair. Stacklights Signal Devices Characteristic curves Chart 1 Excess Gain 100 30 Relays and Timers Pneumatics: Air Prep 20 18%/90% Gain % of Sensing Distance Process Chart 2 Background Suppression 2 6%/90% Pneumatics: Directional Control Valves 10 3 1 90%/90% 10 Pneumatics: Cylinders 0 200 300 400 500 Distance (mm) 0 (m) 4 8 12 16 20 24 Pneumatics: Tubing 28 Distance (m) Pneumatics: Air Fittings 1) Sensing range on black with white background. 2) Sensing range on gray with white background. 3) Sensing range on white with white background. Appendix Book 2 Dimensions Terms and Conditions (mm) Warning: These products are not safety sensors and are not suitable for use in personal safety applications. Horizontal mounting bracket supplied with each unit www.automationdirect.com/photoelectric Photoelectric Sensors Book 2 (14.1) ePH-79 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Company Information Terminal Blocks Cables with quick-disconnect plugs • PVC (polyvinyl chloride) jacket for typical industrial applications • PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 rated • Industry standard axial and right-angle M8/M12 screw-lock connectors with open leads. The cables listed can be used with patch cables • 2m, 3m, 5m, 7m, 10m and 15m cable lengths Power Distribution Blocks Wiring Accessories CD08-0A-020-C1 and -A1 shown Multi-wire Connectors M8 Quick-Disconnect Cables (Pico, Nano) Part Number Price M8 Quick-Disconnects $7.75 CD08-0A-020-A1 $7.75 CD08-0A-020-C1 $10.50 CD08-0A-050-A1 $11.25 CD08-0C-050-A1 $10.50 CD08-0A-050-C1 $11.25 CD08-0C-050-C1 $12.00 CD08-0A-070-A1 $12.00 CD08-0A-070-C1 Length Poles Connector Sensor Cables and Connectors Jacket Dimensions CD08-0A-050-C1 and -A1 shown 2m (6.5 ft.) 3 Axial female PVC Figure 1 2m (6.5 ft.) 3 Right-angle female PVC Figure 2 5m (16.4 ft.) 3 Axial female PVC Figure 4 5m (16.4 ft.) 3 Axial female PUR Figure 3 5m (16.4 ft.) 3 Right-angle female PVC Figure 5 5m (16.4 ft.) 3 Right-angle female PUR Figure 5 7m (23 ft.) 3 Axial female PVC Figure 1 7m (23 ft.) 3 Right-angle female PVC Figure 2 Wiring Duct Cable Ties CD12L-0B-020-A0 and -C0 shown Poles Connector 5m (16.4 ft) 3 Axial female PVC 5m (16.4 ft) 3 Axial female PUR Figure 9 5m (16.4 ft) 3 Right-angle female PVC Figure 10 5m (16.4 ft) 3 Right-angle female PUR Figure 11 2m (6.5 ft) 4 Axial female PVC Figure 6 2m (6.5 ft) 4 Right-angle female PVC Figure 7 7m (23 ft) 4 Axial female PVC Figure 6 Flexible Cord Jacket Dimensions Data Cables Figure 8 7m (23 ft) 4 Right-angle female PVC Figure 7 10m (32.8 ft) 15m (49.2 ft) 10m (32.8 ft) 4 4 4 Axial female Axial female Right-angle female PVC PVC PVC Figure 13 Figure 13 Figure 14 15m (49.2 ft) 4 Right-angle female PVC Figure 14 3m (9.8 ft) 5 Axial female PVC Figure 15 5m (16.4 ft) 5 Axial female PVC Figure 15 10m (32.8 ft) 5 Axial female PVC Figure 15 3m (9.8 ft) 5 Right-angle female PVC Figure 16 5m (16.4 ft) 5 Right-angle female PVC Figure 16 10m (32.8 ft) 3m (9.8 ft) 5m (16.4 ft) 5 8 8 Right-angle female Axial female Axial female PVC PUR PUR Figure 16 Figure 17 Figure 17 10m (32.8 ft) 8 Axial female PUR Figure 17 3m (9.8 ft) 8 Right-angle female PUR Figure 18 5m (16.4 ft) 8 Right-angle female PUR Figure 18 10m (32.8 ft) 8 Right-angle female PUR Figure 18 3m (9.8 ft) 12 Axial female PUR Figure 19 5m (16.4 ft) 12 Axial female PUR Figure 19 10m (32.8 ft) 12 Axial female PUR Figure 19 3m (9.8 ft) 12 Right-angle female PUR Figure 20 5m (16.4 ft) 12 Right-angle female PUR Figure 20 10m (32.8 ft) 12 Right-angle female PUR Figure 20 CD12M-0B-050-C1 and -A1 shown Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection 7000-12221-2141000 Tools Test Equipment Enclosures 7000-12241-2150500 Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions 7000-17041-2951000 7000-19041-7050500 Book 3 (14.1) w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s Wire Multi-conductor Flex Cable Length * Note: Do not use with sensors that require 4-pole cables. M12 Junction Blocks Panel Interface Connectors M12 Quick-Disconnect Cables (Euro, Micro DC-Single Key) Part Number Price M12 Quick-Disconnects $10.50 CD12M-0B-050-A1* $12.50 CD12M-0D-050-A1* $10.50 CD12M-0B-050-C1* $12.50 CD12M-0D-050-C1* $7.75 CD12L-0B-020-A0 $7.75 CD12L-0B-020-C0 $12.00 CD12M-0B-070-A1 $12.00 CD12M-0B-070-C1 7000-12221-2141000 $14.00 7000-12221-2141500 $19.00 7000-12341-2141000 $14.00 7000-12341-2141500 $19.00 7000-12241-2150300 $9.00 7000-12241-2150500 $11.50 7000-12241-2151000 $17.00 7000-12361-2150300 $9.00 7000-12361-2150500 $11.50 7000-12361-2151000 $17.00 7000-17041-2950300 $20.50 7000-17041-2950500 $26.00 7000-17041-2951000 $39.50 7000-17061-2950300 $20.50 7000-17061-2950500 $26.00 7000-17061-2951000 $39.50 7000-19041-7050300 $32.00 7000-19041-7050500 $39.00 7000-19041-7051000 $56.50 7000-19061-7050300 $32.00 7000-19061-7050500 $39.00 7000-19061-7051000 $56.50 ZIPLink Connection System Wiring Solutions eWD-71 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Shielded M12 Cables with quick-disconnect plugs • Industry standard axial and right-angle M12 screw-lock connectors with open leads • Braided shield located inside the cord jacket and connected to the coupling nut • 5m and 10m cable lengths • PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 rated Shielded M12 Quick-Disconnect Cables (Euro, Micro DC-Single Key) Part Number Price Length M12 Quick-Disconnects (shielded) 7000-13201-3310500 $18.00 5m (16.4 ft) 7000-13201-3311000 $27.50 10m (32.8 ft) 7000-13261-3310500 $18.00 5m (16.4 ft) 7000-13261-3311000 $27.50 10m (32.8 ft) 7000-13221-3490500 $21.00 5m (16.4 ft) 7000-13221-3491000 $32.50 10m (32.8 ft) 7000-13281-3490500 $21.00 5m (16.4 ft) 7000-13281-3491000 $32.50 10m (32.8 ft) 7000-17121-2940500 $34.50 5m (16.4 ft) 7000-17121-2941000 $52.00 10m (32.8 ft) 7000-17141-2940500 $34.50 5m (16.4 ft) 7000-17141-2941000 $52.00 10m (32.8 ft) 7000-17121-2941000 7000-17141-2940500 Poles Connector Jacket Dimensions 4 Axial female PUR Figure 21 4 Axial female PUR Figure 21 4 Right-angle female PUR Figure 22 4 Right-angle female PUR Figure 22 5 Axial female PUR Figure 23 5 Axial female PUR Figure 23 5 Right-angle female PUR Figure 24 5 Right-angle female PUR Figure 24 8 Axial female PUR Figure 25 8 Axial female PUR Figure 25 8 Right-angle female PUR Figure 26 8 Right-angle female PUR Figure 26 Cables with LED and quick-disconnect plugs • Industry standard M12 right angle femaleplug with open leads • These cables can be used with patch cables. • 2m, 5m and 10m cable lengths • PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 /IP68 / IP69K, II rated • LED indication for 10-36 VDC PNP sensors only M12 Quick-Disconnect Cables with LED Indicator (Euro, Micro DC-Single Key) Part Number Price Length Poles Connector white wire Pin 2 black wire Pin 4 LED Jacket Dimensions M12 Quick-Disconnects EVC178* $11.00 2m (6.5 ft) 4 Right-angle female Yes PUR Figure 12 EVC179* $11.50 5m (16.4 ft) 4 Right-angle female Yes PUR Figure 12 EVC180* $14.00 10m (32.8 ft) 4 Right-angle female Yes PUR Figure 12 LED Models’ Wiring *Note: LED for 10 to 36 VDC PNP devices only. Do not use with NPN or analog ouput devices. Do not use when white wire (Pin 2) is used for selection of a sensor function. Do not use when emitter has check function. Book 3 (14.1) eWD-72 Wiring Solutions 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Company Information Terminal Blocks Cable Specifications Specification Length Nominal Voltage M8 CD Series 2m (6.5 ft) / 7m (23 ft) 5m (16.4 ft) 50 VAC/75 VDC 60 VAC/VDC Max Current 2m (6.5 ft) / 7m (23 ft) 4A 3/4 pin: 250 VAC/VDC, 4A 5 pin: 125 VAC/VDC, 4A 8 pin: 30 VAC/VDC, 2A 12 pin: 30 VAC/VDC, 1.5A IP67 IP65 / IP68 / IP69K Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks PVC: IP68 PUR: IP68 / IP69K IP67 Nickel plated brass Housing Material Panel Interface Connectors IP67 Nickel plated Zinc Wiring Duct Polyurethane (PUR) or Polyvinyl-chloride (PVC) Contacts Material Conductors Cross Section (AWG) ZIPLink Connection System N/A Material Nut Tightening Torque 5m (16.4 ft) Wiring Accessories 3m (9.8 ft) / 5m (16.4 ft) / 10m (32.8 ft) / 15m (49.2 ft) 30 VAC/VDC; 125 VAC/VDC; 250 VAC/VDC LED Current Loading Protection Degree M12 7000 Series (unshielded) 250 VAC/VDC 4A Power Distribution Blocks Gold plated Copper-Tin Alloy (CuSn) 0.5 Nm m 0.4 Nm 0.5 Nm m 0.4 Nm 0.6 Nm 0.25 mm2 0.25 mm2 0.25 mm2 0.34 mm2 4 x 0.34 mm2 (4 x 22 AWG) 5 x 0.34 mm2 (5 x 22 AWG) 8 x 0.25 mm2 (8 x 24 AWG) 12 x 0.14 mm2 (12 x 26 AWG) 5mm PVC: 4mm PUR: 4mm 5mm PVC: 4.2 mm PUR: 4.3 mm PVC: 5 - 5.2 mm PUR: 6.0 mm -25° to +80°C (-13° to 176°F) -25° to 90°C (-13° to 194°F) N/A Halogen/Silicone free (24 AWG) (24 AWG) (24 AWG) Cable Ties Gold plated brass (22 AWG) Wire Flexible Cord Multi-conductor Flex Cable Data Cables Ø Outer Cable Temperature Range Drag Chain (Roller Cable Tray) Suitability Environmental Function Display Power LED Switching Status LED PVC: -30° to 70°C -25° to +80°C (-22° to 158°F) (-13° to 176°F) PUR: -50° to 90°C (-58° to 194°F) N/A Halogen/Silicone free DC Converters Transformers and Filters N/A Circuit Protection N/A Tools min. 10 x cable diameter Bending Cycles N/A Travel Speed N/A Torsional Strain N/A RoHS Power Supplies PVC: -25° to +70°C (-13° to 158°F) PUR: -25° to +85°C (-13° to 185°F) N/A Bending Radius Agency Approvals Wire Management Products Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components RoHS (UL E325311 8/12 pole) Safety: Protective Wear Terms and Conditions Book 3 (14.1) w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s Wiring Solutions eWD-73 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Cable Specifications M12 7000 Series (shielded) M12 with LED Length 5m (16.4 ft) / 10m (32.8 ft) 2m (6.5 ft) / 5m (16.4 ft) / 10m (32.8 ft) Nominal Voltage 30 VAC/VDC / 60 VAC/VDC 10 to 36 VDC Specification Max Current 2A / 4A 4A LED Current Loading N/A 10 V input Brown wire LED: 1.7 mA White and/or Black LED: 0.9 mA 36V input Brown wire LED: 7.3 mA White and/or Black LED: 4.7 mA Protection Degree IP67 IP67 / IP68 / IP69K Nickel plated Zinc Nickel plated Brass Material Nut Jacket Material Polyurethane (PUR) Housing Material Contacts Material Tightening Torque Polyurethane (PUR) Gold plated Brass 0.6 Nm 0.6 to 1.5 Nm 4 x 0.34 mm2 (4 x 22 AWG) 5 x 0.34 mm2 (5 x 22 AWG) 8 x 0.25 mm2 (8 x 24 AWG) 4 x 0.34 mm2 Ø Outer Cable 4/5 pole: 5.9 mm 8 pole: 7mm 5mm Temperature Range -25° to +80°C (-13° to 176°F) -25° to +90°C (-13° to 194°F) Function Display Power LED N/A Green Switching Status LED Bending Radius Bending Cycles N/A Drag Chain (Roller Cable Tray) Suitability Conductors Cross Section (AWG) Travel Speed Torsional Strain Agency Approvals (4 x 22 AWG) 2 x Yellow min. 10 x cable diameter N/A N/A >5 million Max. 3.3 m/s for a horizontal travel length of 5 meters and max. acceleration of 5 m/s2 N/A ±180°/m RoHS UL File E191684, RoHS UL Reference Part Number Mini-Series Female Cord Connectors Series M12, UL Catalog Number ADOAH043MSS0002H04 EVC178 ADOAH043MSS0005H04 EVC179 ADOAH043MSS0010H04 EVC180 Note: Shown in UL file under Mini-series Female Cord Connectors using catalog number Book 3 (14.1) eWD-74 Wiring Solutions 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Company Information Terminal Blocks Dimensions Power Distribution Blocks mm [inches] Figure 1 Wiring Accessories Figure 2 ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Figure 3 Figure 4 Wire Flexible Cord Multi-conductor Flex Cable Data Cables Figure 5 Wire Management Products Figure 6 Power Supplies DC Converters Transformers and Filters Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Figure 7 Safety: Electrical Components Figure 8 Safety: Protective Wear Terms and Conditions Book 3 (14.1) w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s Wiring Solutions eWD-75 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Dimensions mm [inches] Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Book 3 (14.1) eWD-76 Wiring Solutions 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Company Information Terminal Blocks Dimensions Power Distribution Blocks mm [inches] Wiring Accessories Figure 17 ZIPLink Connection System Figure 18 Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Figure 19 Panel Interface Connectors Figure 20 Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Figure 21 Wire Management Products Figure 22 Power Supplies DC Converters Transformers and Filters Circuit Protection Tools Figure 23 Test Equipment Figure 24 Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Figure 25 Figure 26 Book 3 (14.1) w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s Wiring Solutions eWD-77 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Patch cables with quick-disconnect plugs on each end Available patch cables include: • Industry standard M8 and M12 screw-lock connectors • One male and one female connector • Axial and right-angle connector models • 1m and 3m cable lengths • PVC (polyvinyl chloride)jacket for typical industrial applications • IP67 rated M8 Patch Cables with Quick-Disconnect on Each End (Pico, Nano) Part Number Price Length M8 Quick-Disconnect Patch Cables Poles Connectors Jacket Dimensions 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector PVC Figure 1 PVC Figure 3 PVC Figure 2 PVC Figure 3 CDP08-0A-010-AA $7.75 1m (3.28 ft) 3 CDP08-0A-010-BB $7.75 1m (3.28 ft) 3 CDP08-0A-030-AA $9.50 3m (9.84 ft) 3 CDP08-0A-030-BB $7.75 3m (9.84 ft) 3 M12 Patch Cables with Quick-Disconnect on Each End (Euro, Micro DC-Single Key) Part Number Price Length M12 Quick-Disconnect Patch Cables Poles CDP12-0B-010-AA $7.75 1m (3.28 ft.) 4 CDP12-0B-010-BB $7.75 1m (3.28 ft.) 4 CDP12-0B-030-AA $7.75 3m (9.84 ft.) 4 CDP12-0B-030-BB $9.50 3m (9.84 ft.) 4 7000-40041-2150100 $11.50 1m (3.28 ft.) 5 7000-40041-2150300 $14.00 3m (9.84 ft.) 5 Connectors 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector 2 Axial - One male and one female connector 2 Axial - One male and one female connector Jacket Dimensions PVC Figure 4 PVC Figure 5 PVC Figure 4 PVC Figure 5 PVC Figure 7 PVC Figure 7 Patch Cables with LED Available patch cables with LED include: • Right-angle M12 female plug with LED indication on one end and axial male plug on the other end • 0.3m, 0.6m, 1m, 2m, 5m, and 10m cable lengths white wire Pin 2 • PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 /IP68 / IP69K, II rated • LED indication for 10 -36 VDC PNP sensors only M12 Patch Cables with LED Indicator (Euro, Micro DC-Single Key) Part Number Price Length M12 Patch Cables black wire Pin 4 LED Models’ Wiring Poles Connectors LED Jacket Dimensions EVC322* $11.00 0.3m (0.98 ft) 4 Right-angle female, axial male Yes PUR Figure 6 EVC323* $12.00 0.6m (1.97 ft) 4 Right-angle female, axial male Yes PUR Figure 6 EVC324* $12.50 1m (3.28 ft) 4 Right-angle female, axial male Yes PUR Figure 6 EVC325* $14.50 2m (6.5 ft) 4 Right-angle female, axial male Yes PUR Figure 6 EVC326* $17.00 5m (16.4 ft) 4 Right-angle female, axial male Yes PUR Figure 6 EVC327* $21.50 10m (32.8 ft) 4 Right-angle female, axial male Yes PUR Figure 6 *Note: L ED for 10 to 36 VDC PNP devices only. Do not use with NPN or analog ouput devices. Do not use when white wire (Pin 2) is used for selection of a sensor function. Do not use when emitter has check function. Book 3 (14.1) eWD-78 Wiring Solutions 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Company Information Terminal Blocks Power Distribution Blocks Cable Specifications Specification Length M8 M12 1m (3.28 ft.) / 3m (9.84 ft.) Nominal Voltage 4A LED Current Consumption N/A Material Nut Jacket Material Housing Material Contacts Material Conductors Cross Section (AWG) Tightening Torque Drag Chain (Roller Cable Tray) Suitability Ø Outer Cable Temperature Range Function Display LED Switching Status LED Wiring Accessories 0.3m (0.98 ft) / 0.6m (1.97 ft) / 1m (3.28 ft) 2m (6.5 ft) / 5m (16.4 ft) / 10m (32.8 ft) 125 VAC/VDC 250 VAC/VDC 60 VAC/VDC Max Current Protection Degree M12 with LED ZIPLink Connection System 10 to 36 VDC Multi-wire Connectors 4A 10V input Brown wire LED: 1.7 mA White and/or Black LED: 0.9 mA 36V input Brown wire LED: 7.3 mA White and/or Black LED: 4.7 mA Sensor Cables and Connectors M12 Junction Blocks IEC IP67 Zinc pressure die casting surface Nickel plated brass (Ni4-6), Nickel plated brass PolyVinyl Chloride (PVC) IEC IP67/IP68/IP69K Polyurethane (PUR) Connector: Orange PUR, Socket: Black PUR Copper-tin(CuSn) plated brass Gold plated brass 0.34 mm² 0.34 mm² (22 AWG) Plug: 0.6 to 1.5 Nm (take into account the maximum value of the counterpart) Socket: 0.6 to 1.5 Nm 5mm 0.5 Nm 0.6 Nm, 0.5 Nm 5mm 5.2 mm, 5mm Panel Interface Connectors Nickel plated brass Wiring Duct Polyurethane (PUR) -25° to +70°C (-13° to 158°F) -25° to +90°C (-13° to 194°F) N/A Green N/A Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products 2 x Yellow Bending Radius min. 10 x cable diameter Power Supplies Bending Cycles >5 million DC Converters Travel Speed Torsional Strain Agency Approvals N/A Max. 3.3 m/s for a horizontal travel length of 5 m and max. acceleration of 5 m/s² N/A ±180°/m RoHS UL File E191684, RoHS Transformers and Filters Circuit Protection Tools Test Equipment UL Reference Part Number EVC322 EVC323 EVC324 EVC325 EVC326 EVC327 Enclosures Cable Assemblies Series M12, UL Catalog Number VDOAH043MSS00.3H04STGH040MSS VDOAH043MSS00.6H04STGH040MSS VDOAH043MSS0001H04STGH040MSS VDOAH043MSS0002H04STGH040MSS VDOAH043MSS0005H04STGH040MSS VDOAH043MSS0010H04STGH040MSS Note: S  hown in UL file under Cable Assemblies using catalog number Book 3 (14.1) w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s Wiring Solutions eWD-79 Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Dimensions Figure 1 mm [inches] Figure 2 Figure 4 Figure 3 Figure 6 Figure 5 Figure 7 Book 3 (14.1) eWD-80 Wiring Solutions 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Company Information Terminal Blocks Cables with quick-disconnect plugs for Sensor Models Power Distribution Blocks Do not use extension cables with the cables listed below. The physical pin configurations do not match. Wiring Accessories Available cables include: • Industry standard M8 screw-lock connectors • Axial and right-angle connector models • 2m, 5m and 10m cable lengths • PVC (polyvinyl chloride) jacket for typical industrial applications • IP68 rated ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors M8 Cables with Quick-Disconnect Part Number Price Length Poles Connectors Jacket Dimensions Wiring Duct M8 Quick-Disconnects Cable Ties CD08-0G-020-A1 $8.75 2m (6.56 ft.) 4 Axial female PVC Figure 1 CD08-0W-020-C1 $8.75 2m (6.56 ft.) 4 Right-angle female PVC Figure 2 Wire CD08-0G-050-A1 $10.50 5m (16.4 ft.) 4 Axial female PVC Figure 1 Flexible Cord CD08-0W-050-C1 $10.50 5m (16.4 ft.) 4 Right-angle female PVC Figure 2 CD08-0G-100-A1 $13.25 10m (32.8 ft.) 4 Axial female PVC Figure 1 CD08-0W-100-C1 $13.25 10m (32.8 ft.) 4 Right-angle female PVC Figure 2 Dimensions (mm) Cable Specifications M8 Use these cables if the sensor pin configuration looks like the connector pin-out below. M8 Connector Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies Figure 1 DC Converters Length 2m (6.56 ft.) 5m (16.4 ft.) 10m (32.8 ft.) Transformers and Filters Nominal Voltage 30VAC/30VDC Circuit Protection Nominal Current 4A Protection Degree Contact Body Material PUR Contacts Material CuSn Ø Outer Cable Temperature Range Test Equipment ABS Housing Material Conductors Section Tools IEC IP67 0.25 mm2 Enclosures Figure 2 Enclosure Climate Control 4.5 mm Safety: Electrical Components -5° to +70°C (23° to 158°F) Safety: Protective Wear Terms and Conditions Book 3 (14.1) w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s Wiring Solutions eWD-81 Prices as of April 16, 2014. Check Web site for most current prices. Accessories: Reflectors and Shutters Company Information Drives RL series reflectors for polarized Retroreflective photoelectric sensors (all models) Soft Starters Motors • S uitable for use with polarized light photoelectric sensors • S hapes and sizes for most applications •M  iniature types for close mounting in multiple sensor installations • S ingle hole, dual hole and stud mounting types available • 1 0 reflectors per package Power Transmission Motion: Servos and Steppers Motor Controls Sensors: Proximity Installation notes •K  eep the reflector surface clean to ensure peak detection performance. This is especially true when the maximum sensing range is being used. Clean using a damp cloth. •W  hen selecting a reflector, it is important to consider the ambient conditions it will be exposed to. Dusty or high humidity conditions may reduce the sensing range as much as 90%. •R  eflectors should be positioned at a 90° angle to the optical axis with a tolerance of ±15°. Sensors: Photoelectric Sensors: Encoders Sensors: Limit Switches Sensors: Current Specifications Model Price (10 per pack) RL102 RL103 RL104 RL105 RL106G RL110 3 RL116 $33.50 $43.50 $43.50 $43.50 $66.00 $22.00 $24.00 % Sensing Range Using SSP 1 50% 40% 50% 50% 50% 100% 85% % Sensing Range Using QXP 1 -- 35% 60% 50% 45% Dimensions Degree of Protection Mounting Materials Ø26mm (1.024 in) Ø36mm (1.42 in) 100% -- 182 x 42 mm (7.17 x 1.65 in) Ø84mm (3.31 in) 41 x 60 mm (3.54 x 2.36 in) two Ø4.3 mm holes two Ø6mm holes one Ø5mm hole two M3 holes 90 x 40 mm Ø47mm (1.85 in) (3.54 x 1.5748 in) 2 IEC IP67 Customer-supplied adhesive or other mounting method required Reflective face: PMMA Polymethylmethacrylate (acrylic); base material: ABS (Acrylonitrile-butadiene-styren) 1 Refer to individual catalog pages for detailed explanations of these photoelectric sensors. 2 Not recommended for applications involving moist air environments or water immersion. 3 All reflective sensors are shipped with an RL116 reflector. Sensors: Pressure Sensors: Temperature Sensors: Level Sensors: Flow Switches Pushbuttons and Lights Stacklights Signal Devices Process Relays and Timers Dimensions Pneumatics: Air Prep inches [mm] Pneumatics: Directional Control Valves Pneumatics: Cylinders 1.14” 29 mm 1.38” 35 mm Pneumatics: Tubing Pneumatics: Air Fittings 5.7 mm thickness Appendix Book 2 Terms and Conditions www.automationdirect.com/photoelectric Photoelectric Sensors Book 2 (14.1) e101 Prices as of April 16, 2014. Check Web site for most current prices. Accessories: Reflectors and Shutters Dimensions inches [mm] RL116 ST0S1 through ST0S8 shutters for M18 (18mm) through-beam sensors (SSE / SSR) •  Reduces the emitted beam, allowing the detection of small targets •  Shutter consists of an aluminum cap and aperture with an O-ring and glass lens, which can screw onto the optical head of either the emitter or receiver. The following table shows the sensing distance and minimal detectable object. Sensing Distance (when used with SSE / SSR Model Photoelectric switches) Model ST0S1 ST0S2 ST0S4 ST0S6 ST0S8 Price $13.50 $13.50 $13.50 $13.50 $9.50 1 2 4 6 8 N/A N/A N/A N/A 1.5 2 3.5 3 6.5 4 Ø x shutter (mm) Distance (m) object (mm) Book 2 (14.1) e102 Photoelectric Sensors 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. Accessories: Reflectors, Adapters & Mounting Brackets RL series reflectors for polarized reflective Laser photoelectric sensors (FALN series) • Suitable for use with polarized light Laser photoelectric sensors • Sizes for most applications • Miniature types for close mounting in multiple sensor installations • 5 reflectors per package Company Information Drives Soft Starters Specifications Model Sensing Range Using FALN 1 Dimensions Mounting Degree of Protection Motors RL201 RL203 RL204 30m 7m 7m 60mm x 82mm 19mm x 60mm 20mm x 32mm two Ø4mm holes two Ø5mm holes two Ø3mm holes 2 Motion: Servos and Steppers Motor Controls IEC IP67 Materials Power Transmission Acrylic/polycarbonate Sensors: Proximity 1 Refer to individual catalog pages for detailed explanations of these photoelectric sensors. 2 Not recommended for applications involving moist air environments or water immersion. Note: All reflective sensors are shipped with an RL110 reflector. Purchase additional reflectors separately. Sensors: Photoelectric Sensors: Encoders RL201 RL203 Sensors: Limit Switches RL204 Sensors: Current 20mm Sensors: Pressure 10mm Sensors: Temperature 50mm $27.00 Sensors: Level 60 mm $27.00 5 mm $27.00 (5 per pack) (5 per pack) Sensors: Flow Switches (5 per pack) Pushbuttons and Lights ST02 plastic swivel bracket M18 (18 mm) ST03 right-angle M18 (18 mm) beam adapter For use with M18 retroreflective and through-beam photoelectric switches (not for use with diffuse reflection sensors). Allows 90° light detection using an internal mirror set at 45° to the optical axis. Sensitivity loss is about 20-30%. $13.50 Plastic mounting bracket for use with M18 photoelectric switches. Has a ball-joint and set screws to adjust sensor orientation. Allows orientation in all directions for retroreflective and through-beam sensors. (Will not work with C18 series). Stacklights Signal Devices Process Relays and Timers $8.25 Pneumatics: Air Prep Pneumatics: Directional Control Valves Pneumatics: Cylinders Pneumatics: Tubing Pneumatics: Air Fittings Appendix Book 2 Terms and Conditions www.automationdirect.com/photoelectric Photoelectric Sensors Book 2 (14.1) e103 Prices as of April 16, 2014. Check Web site for most current prices. Accessories: Mounting Brackets ST12A axial bracket For mounting M12 (12 mm) sensors. Has two mounting holes (use 3 mm screws) and allows the rotation of an optical axis for right-beam angle adapter sensors. Brackets ST12C right-angle bracket Angular mounting bracket for use with M12 (12 mm) sensors. Has two mounting holes (use 3 mm screws) and allows the rotation of an optical axis for axial sensors. Brackets Part Number Price Description $2.00 Metal axial bracket for 12 mm sensors, 1/pk ST12A $6.00 316L stainless steel axial bracket for 12 mm sensors, 1/pk ST12A7W Part Number Price Description $2.00 Metal right angle bracket for 12 mm sensors, 1/pk ST12C $6.00 316L stainless steel right angle bracket for 12 mm sensors, 1/pk ST12C7W ST18A axial bracket ST18C right-angle bracket Mounting bracket for M18 (18mm) sensors. Has two mounting holes (use 4 mm screws) and allows the rotation of an optical axis for right-beam angle adapter sensors. Angular mounting bracket for M18 (18 mm) sensors. Has two mounting holes (use 4 mm screws) and allows the rotation of an optical axis for axial sensors. Brackets Brackets Part Number Price Description $1.25 Metal axial bracket for 18 mm sensors, 1/pk ST18A $6.00 316L stainless steel axial bracket for 18 mm sensors, 1/pk ST18A7W Part Number Price Description $1.25 Metal right angle bracket for 18 mm sensors, 1/pk ST18C $6.00 316L stainless steel right angle bracket for 18 mm sensors, 1/pk ST18C7W slot for M4 screw fixing slot for M4 screw fixing Book 2 (14.1) e104 Photoelectric Sensors 1-800-633-0405