Transcript
Prices as of October 22, 2014. Check Web site for most current prices.
FG Series Photoelectric Sensors Rectangular plastic - AC/DC
• Universal supply voltage: 12-240 VDC or 24-240 VAC • Diffuse w/background suppression and through-beam models • Plastic housing • SPDT electrically isolated output • Adjustable sensitivity • IP67 rated
FG Series Photoelectric Sensors Selection Chart Part Number
Price
Sensing Range
Diffuse with background suppression $104.00 up to 550mm (21.65in) FGRW-DT-0A Through-beam* $108.00 up to 20m (65.62ft) FGRHD-DT-0A
Output
Connection
Wiring
Dimensions
Characteristic Curves
SPDT Relay
2m (6.5) axial cable
Diagram 1
Figure 1
Chart 1
SPDT Relay
2m (6.5) axial cable
Diagram 1 and 2
Figure 2
Chart 2
*Through-beam model consists of an emitter and receiver pair.
Switching Element Function Reflective Thru-beam Models Diffuse Models Light on N.C. Dark on N.O.
N.O. N.C.
Wiring diagrams Diagram 1
Diagram 2 Emitter
Dimensions (mm)
Figure 1
Figure 2
1) Emitter center of optical axis 2) Receiver center of optical axis Book 2 (14.1)
ePH-78
Photoelectric Sensors
1-800-633-0405
Prices as of October 22, 2014. Check Web site for most current prices.
FG Series Photoelectric Sensors Specifications
Diffuse Models
Type Sensing Distance Light Spot Diameter Emission Sensitivity Output Type Operating Voltage No-load Supply Current Operating (Load) Current Off-state (Leakage) Current Voltage Drop Switching Frequency Ripple Time Delay before Availability (tv) Short-Circuit Protection Operating Temperature Protection Degree (DIN 40050) LED Indicators - Switching Status Housing Material Lens Material Shock/Vibration Tightening Torque Weight Connectors Agency Approvals
Company Information
Through-Beam Models
Diffuse reflection
Through-beam
550mm1
20m
–
1.5m @ 20m
Drives
2
Soft Starters Motors
Red LED (visable)
Power Transmission
Adjustable SPDT relay electrically isolated
Motion: Servos and Steppers
12-240VDC or 24-240VAC
Motor Controls
m2VA 3A @ 240VAC/30VDC
Sensors: Proximity
– –
Sensors: Photoelectric
33Hz –
Sensors: Encoders
150 ms
Sensors: Limit Switches
Yes, switch autoresets after load is removed -25 to 55°C (-13° to 131° F)
Sensors: Current
IEC IP67 Red LED - Switching status
Sensors: Pressure
ABS Polycarbonate (PC)
Sensors: Temperature
See terminology section N/A 160g (5.64oz)
Sensors: Level
Emitter/Receiver pair 290g(10.23oz) 2m (6.5’) axial cable
Sensors: Flow Switches
UL Recognized E224302, CE
Pushbuttons and Lights
1With 100x100mm white matte paper 2Each through-beam part number consists of an emitter and receiver pair.
Stacklights Signal Devices
Characteristic curves Chart 1
Excess Gain
100
30
Relays and Timers Pneumatics: Air Prep
20
18%/90%
Gain
% of Sensing Distance
Process
Chart 2
Background Suppression
2
6%/90%
Pneumatics: Directional Control Valves
10
3
1
90%/90%
10
Pneumatics: Cylinders 0
200
300
400
500
Distance (mm)
0
(m)
4
8
12
16
20
24
Pneumatics: Tubing
28
Distance (m)
Pneumatics: Air Fittings
1) Sensing range on black with white background. 2) Sensing range on gray with white background. 3) Sensing range on white with white background.
Appendix Book 2
Dimensions
Terms and Conditions
(mm) Warning: These products are not safety sensors and are not suitable for use in personal safety applications.
Horizontal mounting bracket supplied with each unit
www.automationdirect.com/photoelectric
Photoelectric Sensors
Book 2 (14.1)
ePH-79
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors
Company Information Terminal Blocks
Cables with quick-disconnect plugs
• PVC (polyvinyl chloride) jacket for typical industrial applications • PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 rated
• Industry standard axial and right-angle M8/M12 screw-lock connectors with open leads. The cables listed can be used with patch cables • 2m, 3m, 5m, 7m, 10m and 15m cable lengths
Power Distribution Blocks Wiring Accessories
CD08-0A-020-C1 and -A1 shown
Multi-wire Connectors
M8 Quick-Disconnect Cables (Pico, Nano) Part Number Price M8 Quick-Disconnects $7.75 CD08-0A-020-A1 $7.75 CD08-0A-020-C1 $10.50 CD08-0A-050-A1 $11.25 CD08-0C-050-A1 $10.50 CD08-0A-050-C1 $11.25 CD08-0C-050-C1 $12.00 CD08-0A-070-A1 $12.00 CD08-0A-070-C1
Length
Poles
Connector
Sensor Cables and Connectors
Jacket
Dimensions CD08-0A-050-C1 and -A1 shown
2m (6.5 ft.)
3
Axial female
PVC
Figure 1
2m (6.5 ft.)
3
Right-angle female
PVC
Figure 2
5m (16.4 ft.)
3
Axial female
PVC
Figure 4
5m (16.4 ft.)
3
Axial female
PUR
Figure 3
5m (16.4 ft.)
3
Right-angle female
PVC
Figure 5
5m (16.4 ft.)
3
Right-angle female
PUR
Figure 5
7m (23 ft.)
3
Axial female
PVC
Figure 1
7m (23 ft.)
3
Right-angle female
PVC
Figure 2
Wiring Duct Cable Ties
CD12L-0B-020-A0 and -C0 shown
Poles
Connector
5m (16.4 ft)
3
Axial female
PVC
5m (16.4 ft)
3
Axial female
PUR
Figure 9
5m (16.4 ft)
3
Right-angle female
PVC
Figure 10
5m (16.4 ft)
3
Right-angle female
PUR
Figure 11
2m (6.5 ft)
4
Axial female
PVC
Figure 6
2m (6.5 ft)
4
Right-angle female
PVC
Figure 7
7m (23 ft)
4
Axial female
PVC
Figure 6
Flexible Cord
Jacket Dimensions
Data Cables
Figure 8
7m (23 ft)
4
Right-angle female
PVC
Figure 7
10m (32.8 ft) 15m (49.2 ft) 10m (32.8 ft)
4 4 4
Axial female Axial female Right-angle female
PVC PVC PVC
Figure 13 Figure 13 Figure 14
15m (49.2 ft)
4
Right-angle female
PVC
Figure 14
3m (9.8 ft)
5
Axial female
PVC
Figure 15
5m (16.4 ft)
5
Axial female
PVC
Figure 15
10m (32.8 ft)
5
Axial female
PVC
Figure 15
3m (9.8 ft)
5
Right-angle female
PVC
Figure 16
5m (16.4 ft)
5
Right-angle female
PVC
Figure 16
10m (32.8 ft) 3m (9.8 ft) 5m (16.4 ft)
5 8 8
Right-angle female Axial female Axial female
PVC PUR PUR
Figure 16 Figure 17 Figure 17
10m (32.8 ft)
8
Axial female
PUR
Figure 17
3m (9.8 ft)
8
Right-angle female
PUR
Figure 18
5m (16.4 ft)
8
Right-angle female
PUR
Figure 18
10m (32.8 ft)
8
Right-angle female
PUR
Figure 18
3m (9.8 ft)
12
Axial female
PUR
Figure 19
5m (16.4 ft)
12
Axial female
PUR
Figure 19
10m (32.8 ft)
12
Axial female
PUR
Figure 19
3m (9.8 ft)
12
Right-angle female
PUR
Figure 20
5m (16.4 ft)
12
Right-angle female
PUR
Figure 20
10m (32.8 ft)
12
Right-angle female
PUR
Figure 20
CD12M-0B-050-C1 and -A1 shown
Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection
7000-12221-2141000
Tools Test Equipment Enclosures
7000-12241-2150500
Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions
7000-17041-2951000
7000-19041-7050500 Book 3 (14.1)
w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s
Wire
Multi-conductor Flex Cable
Length
* Note: Do not use with sensors that require 4-pole cables.
M12 Junction Blocks Panel Interface Connectors
M12 Quick-Disconnect Cables (Euro, Micro DC-Single Key) Part Number Price M12 Quick-Disconnects $10.50 CD12M-0B-050-A1* $12.50 CD12M-0D-050-A1* $10.50 CD12M-0B-050-C1* $12.50 CD12M-0D-050-C1* $7.75 CD12L-0B-020-A0 $7.75 CD12L-0B-020-C0 $12.00 CD12M-0B-070-A1 $12.00 CD12M-0B-070-C1 7000-12221-2141000 $14.00 7000-12221-2141500 $19.00 7000-12341-2141000 $14.00 7000-12341-2141500 $19.00 7000-12241-2150300 $9.00 7000-12241-2150500 $11.50 7000-12241-2151000 $17.00 7000-12361-2150300 $9.00 7000-12361-2150500 $11.50 7000-12361-2151000 $17.00 7000-17041-2950300 $20.50 7000-17041-2950500 $26.00 7000-17041-2951000 $39.50 7000-17061-2950300 $20.50 7000-17061-2950500 $26.00 7000-17061-2951000 $39.50 7000-19041-7050300 $32.00 7000-19041-7050500 $39.00 7000-19041-7051000 $56.50 7000-19061-7050300 $32.00 7000-19061-7050500 $39.00 7000-19061-7051000 $56.50
ZIPLink Connection System
Wiring Solutions
eWD-71
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors Shielded M12 Cables with quick-disconnect plugs • Industry standard axial and right-angle M12 screw-lock connectors with open leads • Braided shield located inside the cord jacket and connected to the coupling nut
• 5m and 10m cable lengths • PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 rated
Shielded M12 Quick-Disconnect Cables (Euro, Micro DC-Single Key) Part Number
Price Length
M12 Quick-Disconnects (shielded) 7000-13201-3310500 $18.00 5m (16.4 ft) 7000-13201-3311000 $27.50 10m (32.8 ft) 7000-13261-3310500 $18.00 5m (16.4 ft) 7000-13261-3311000 $27.50 10m (32.8 ft) 7000-13221-3490500 $21.00 5m (16.4 ft) 7000-13221-3491000 $32.50 10m (32.8 ft) 7000-13281-3490500 $21.00 5m (16.4 ft) 7000-13281-3491000 $32.50 10m (32.8 ft) 7000-17121-2940500 $34.50 5m (16.4 ft) 7000-17121-2941000 $52.00 10m (32.8 ft) 7000-17141-2940500 $34.50 5m (16.4 ft) 7000-17141-2941000 $52.00 10m (32.8 ft)
7000-17121-2941000
7000-17141-2940500
Poles
Connector
Jacket Dimensions
4
Axial female
PUR
Figure 21
4
Axial female
PUR
Figure 21
4
Right-angle female
PUR
Figure 22
4
Right-angle female
PUR
Figure 22
5
Axial female
PUR
Figure 23
5
Axial female
PUR
Figure 23
5
Right-angle female
PUR
Figure 24
5
Right-angle female
PUR
Figure 24
8
Axial female
PUR
Figure 25
8
Axial female
PUR
Figure 25
8
Right-angle female
PUR
Figure 26
8
Right-angle female
PUR
Figure 26
Cables with LED and quick-disconnect plugs • Industry standard M12 right angle femaleplug with open leads • These cables can be used with patch cables. • 2m, 5m and 10m cable lengths
• PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 /IP68 / IP69K, II rated • LED indication for 10-36 VDC PNP sensors only
M12 Quick-Disconnect Cables with LED Indicator (Euro, Micro DC-Single Key) Part Number Price Length Poles Connector
white wire Pin 2
black wire Pin 4
LED Jacket Dimensions
M12 Quick-Disconnects EVC178* $11.00 2m (6.5 ft)
4
Right-angle female Yes
PUR
Figure 12
EVC179* $11.50 5m (16.4 ft)
4
Right-angle female Yes
PUR
Figure 12
EVC180* $14.00 10m (32.8 ft)
4
Right-angle female Yes
PUR
Figure 12
LED Models’ Wiring
*Note: LED for 10 to 36 VDC PNP devices only. Do not use with NPN or analog ouput devices. Do not use when white wire (Pin 2) is used for selection of a sensor function. Do not use when emitter has check function.
Book 3 (14.1)
eWD-72
Wiring Solutions
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors
Company Information Terminal Blocks
Cable Specifications Specification Length Nominal Voltage
M8
CD Series
2m (6.5 ft) / 7m (23 ft)
5m (16.4 ft)
50 VAC/75 VDC
60 VAC/VDC
Max Current
2m (6.5 ft) / 7m (23 ft)
4A
3/4 pin: 250 VAC/VDC, 4A 5 pin: 125 VAC/VDC, 4A 8 pin: 30 VAC/VDC, 2A 12 pin: 30 VAC/VDC, 1.5A
IP67
IP65 / IP68 / IP69K
Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks
PVC: IP68 PUR: IP68 / IP69K
IP67
Nickel plated brass
Housing Material
Panel Interface Connectors
IP67 Nickel plated Zinc
Wiring Duct
Polyurethane (PUR) or Polyvinyl-chloride (PVC)
Contacts Material
Conductors Cross Section (AWG)
ZIPLink Connection System
N/A
Material Nut
Tightening Torque
5m (16.4 ft)
Wiring Accessories
3m (9.8 ft) / 5m (16.4 ft) / 10m (32.8 ft) / 15m (49.2 ft) 30 VAC/VDC; 125 VAC/VDC; 250 VAC/VDC
LED Current Loading Protection Degree
M12 7000 Series (unshielded)
250 VAC/VDC
4A
Power Distribution Blocks
Gold plated Copper-Tin Alloy (CuSn) 0.5 Nm
m 0.4 Nm
0.5 Nm
m 0.4 Nm
0.6 Nm
0.25 mm2
0.25 mm2
0.25 mm2
0.34 mm2
4 x 0.34 mm2 (4 x 22 AWG) 5 x 0.34 mm2 (5 x 22 AWG) 8 x 0.25 mm2 (8 x 24 AWG) 12 x 0.14 mm2 (12 x 26 AWG)
5mm
PVC: 4mm PUR: 4mm
5mm
PVC: 4.2 mm PUR: 4.3 mm
PVC: 5 - 5.2 mm PUR: 6.0 mm
-25° to +80°C (-13° to 176°F)
-25° to 90°C (-13° to 194°F)
N/A
Halogen/Silicone free
(24 AWG)
(24 AWG)
(24 AWG)
Cable Ties
Gold plated brass
(22 AWG)
Wire Flexible Cord Multi-conductor Flex Cable Data Cables
Ø Outer Cable
Temperature Range
Drag Chain (Roller Cable Tray) Suitability
Environmental Function Display Power LED Switching Status LED
PVC: -30° to 70°C -25° to +80°C (-22° to 158°F) (-13° to 176°F) PUR: -50° to 90°C (-58° to 194°F) N/A
Halogen/Silicone free
DC Converters Transformers and Filters
N/A
Circuit Protection
N/A
Tools
min. 10 x cable diameter
Bending Cycles
N/A
Travel Speed
N/A
Torsional Strain
N/A RoHS
Power Supplies
PVC: -25° to +70°C (-13° to 158°F) PUR: -25° to +85°C (-13° to 185°F)
N/A
Bending Radius
Agency Approvals
Wire Management Products
Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components
RoHS (UL E325311 8/12 pole)
Safety: Protective Wear Terms and Conditions
Book 3 (14.1)
w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s
Wiring Solutions
eWD-73
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors Cable Specifications
M12 7000 Series (shielded)
M12 with LED
Length
5m (16.4 ft) / 10m (32.8 ft)
2m (6.5 ft) / 5m (16.4 ft) / 10m (32.8 ft)
Nominal Voltage
30 VAC/VDC / 60 VAC/VDC
10 to 36 VDC
Specification
Max Current
2A / 4A
4A
LED Current Loading
N/A
10 V input Brown wire LED: 1.7 mA White and/or Black LED: 0.9 mA 36V input Brown wire LED: 7.3 mA White and/or Black LED: 4.7 mA
Protection Degree
IP67
IP67 / IP68 / IP69K
Nickel plated Zinc
Nickel plated Brass
Material Nut Jacket Material
Polyurethane (PUR)
Housing Material Contacts Material Tightening Torque
Polyurethane (PUR) Gold plated Brass 0.6 Nm
0.6 to 1.5 Nm
4 x 0.34 mm2 (4 x 22 AWG) 5 x 0.34 mm2 (5 x 22 AWG) 8 x 0.25 mm2 (8 x 24 AWG)
4 x 0.34 mm2
Ø Outer Cable
4/5 pole: 5.9 mm 8 pole: 7mm
5mm
Temperature Range
-25° to +80°C (-13° to 176°F)
-25° to +90°C (-13° to 194°F)
Function Display Power LED
N/A
Green
Switching Status LED Bending Radius Bending Cycles
N/A
Drag Chain (Roller Cable Tray) Suitability
Conductors Cross Section (AWG)
Travel Speed
Torsional Strain Agency Approvals
(4 x 22 AWG)
2 x Yellow min. 10 x cable diameter
N/A N/A
>5 million Max. 3.3 m/s for a horizontal travel length of 5 meters and max. acceleration of 5 m/s2
N/A
±180°/m
RoHS
UL File E191684, RoHS
UL Reference Part Number Mini-Series Female Cord Connectors Series M12, UL Catalog Number ADOAH043MSS0002H04 EVC178 ADOAH043MSS0005H04 EVC179 ADOAH043MSS0010H04 EVC180 Note: Shown in UL file under Mini-series Female Cord Connectors using catalog number
Book 3 (14.1)
eWD-74
Wiring Solutions
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors
Company Information Terminal Blocks
Dimensions
Power Distribution Blocks
mm [inches]
Figure 1
Wiring Accessories
Figure 2
ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties
Figure 3
Figure 4
Wire Flexible Cord Multi-conductor Flex Cable Data Cables
Figure 5
Wire Management Products
Figure 6
Power Supplies DC Converters Transformers and Filters Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control
Figure 7
Safety: Electrical Components
Figure 8
Safety: Protective Wear Terms and Conditions
Book 3 (14.1)
w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s
Wiring Solutions
eWD-75
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors Dimensions mm [inches]
Figure 9
Figure 10
Figure 11
Figure 12
Figure 13
Figure 14
Figure 15
Figure 16
Book 3 (14.1)
eWD-76
Wiring Solutions
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors
Company Information Terminal Blocks
Dimensions
Power Distribution Blocks
mm [inches]
Wiring Accessories
Figure 17
ZIPLink Connection System
Figure 18
Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks
Figure 19
Panel Interface Connectors
Figure 20
Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables
Figure 21
Wire Management Products
Figure 22
Power Supplies DC Converters Transformers and Filters Circuit Protection Tools
Figure 23
Test Equipment
Figure 24
Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions
Figure 25
Figure 26
Book 3 (14.1)
w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s
Wiring Solutions
eWD-77
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors Patch cables with quick-disconnect plugs on each end Available patch cables include: • Industry standard M8 and M12 screw-lock connectors • One male and one female connector • Axial and right-angle connector models
• 1m and 3m cable lengths • PVC (polyvinyl chloride)jacket for typical industrial applications • IP67 rated
M8 Patch Cables with Quick-Disconnect on Each End (Pico, Nano) Part Number Price Length M8 Quick-Disconnect Patch Cables
Poles
Connectors
Jacket
Dimensions
2 Axial - One male and one female connector 2 Right-angle - One male and one female connector 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector
PVC
Figure 1
PVC
Figure 3
PVC
Figure 2
PVC
Figure 3
CDP08-0A-010-AA
$7.75
1m (3.28 ft)
3
CDP08-0A-010-BB
$7.75
1m (3.28 ft)
3
CDP08-0A-030-AA
$9.50
3m (9.84 ft)
3
CDP08-0A-030-BB
$7.75
3m (9.84 ft)
3
M12 Patch Cables with Quick-Disconnect on Each End (Euro, Micro DC-Single Key) Part Number Price Length M12 Quick-Disconnect Patch Cables
Poles
CDP12-0B-010-AA
$7.75 1m (3.28 ft.)
4
CDP12-0B-010-BB
$7.75 1m (3.28 ft.)
4
CDP12-0B-030-AA
$7.75 3m (9.84 ft.)
4
CDP12-0B-030-BB
$9.50 3m (9.84 ft.)
4
7000-40041-2150100 $11.50 1m (3.28 ft.)
5
7000-40041-2150300 $14.00 3m (9.84 ft.)
5
Connectors 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector 2 Axial - One male and one female connector 2 Axial - One male and one female connector
Jacket
Dimensions
PVC
Figure 4
PVC
Figure 5
PVC
Figure 4
PVC
Figure 5
PVC
Figure 7
PVC
Figure 7
Patch Cables with LED Available patch cables with LED include: • Right-angle M12 female plug with LED indication on one end and axial male plug on the other end • 0.3m, 0.6m, 1m, 2m, 5m, and 10m cable lengths
white wire Pin 2
• PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 /IP68 / IP69K, II rated • LED indication for 10 -36 VDC PNP sensors only
M12 Patch Cables with LED Indicator (Euro, Micro DC-Single Key) Part Number Price Length M12 Patch Cables
black wire Pin 4
LED Models’ Wiring
Poles Connectors
LED Jacket Dimensions
EVC322* $11.00 0.3m (0.98 ft)
4
Right-angle female, axial male
Yes
PUR
Figure 6
EVC323* $12.00 0.6m (1.97 ft)
4
Right-angle female, axial male
Yes
PUR
Figure 6
EVC324* $12.50 1m (3.28 ft)
4
Right-angle female, axial male
Yes
PUR
Figure 6
EVC325* $14.50 2m (6.5 ft)
4
Right-angle female, axial male
Yes
PUR
Figure 6
EVC326* $17.00 5m (16.4 ft)
4
Right-angle female, axial male
Yes
PUR
Figure 6
EVC327* $21.50 10m (32.8 ft)
4
Right-angle female, axial male
Yes
PUR
Figure 6
*Note: L ED for 10 to 36 VDC PNP devices only. Do not use with NPN or analog ouput devices. Do not use when white wire (Pin 2) is used for selection of a sensor function. Do not use when emitter has check function. Book 3 (14.1)
eWD-78
Wiring Solutions
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors
Company Information Terminal Blocks Power Distribution Blocks
Cable Specifications Specification Length
M8
M12
1m (3.28 ft.) / 3m (9.84 ft.)
Nominal Voltage
4A
LED Current Consumption
N/A
Material Nut Jacket Material Housing Material Contacts Material Conductors Cross Section (AWG) Tightening Torque
Drag Chain (Roller Cable Tray) Suitability
Ø Outer Cable Temperature Range Function Display LED Switching Status LED
Wiring Accessories
0.3m (0.98 ft) / 0.6m (1.97 ft) / 1m (3.28 ft) 2m (6.5 ft) / 5m (16.4 ft) / 10m (32.8 ft)
125 VAC/VDC 250 VAC/VDC
60 VAC/VDC
Max Current
Protection Degree
M12 with LED
ZIPLink Connection System
10 to 36 VDC
Multi-wire Connectors
4A 10V input Brown wire LED: 1.7 mA White and/or Black LED: 0.9 mA 36V input Brown wire LED: 7.3 mA White and/or Black LED: 4.7 mA
Sensor Cables and Connectors M12 Junction Blocks
IEC IP67 Zinc pressure die casting surface Nickel plated brass (Ni4-6), Nickel plated brass PolyVinyl Chloride (PVC)
IEC IP67/IP68/IP69K
Polyurethane (PUR)
Connector: Orange PUR, Socket: Black PUR
Copper-tin(CuSn) plated brass
Gold plated brass
0.34 mm²
0.34 mm² (22 AWG) Plug: 0.6 to 1.5 Nm (take into account the maximum value of the counterpart) Socket: 0.6 to 1.5 Nm 5mm
0.5 Nm
0.6 Nm, 0.5 Nm
5mm
5.2 mm, 5mm
Panel Interface Connectors
Nickel plated brass
Wiring Duct
Polyurethane (PUR)
-25° to +70°C (-13° to 158°F)
-25° to +90°C (-13° to 194°F)
N/A
Green
N/A
Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products
2 x Yellow
Bending Radius
min. 10 x cable diameter
Power Supplies
Bending Cycles
>5 million
DC Converters
Travel Speed Torsional Strain
Agency Approvals
N/A
Max. 3.3 m/s for a horizontal travel length of 5 m and max. acceleration of 5 m/s²
N/A
±180°/m
RoHS
UL File E191684, RoHS
Transformers and Filters Circuit Protection Tools Test Equipment
UL Reference Part Number EVC322 EVC323 EVC324 EVC325 EVC326 EVC327
Enclosures
Cable Assemblies Series M12, UL Catalog Number VDOAH043MSS00.3H04STGH040MSS VDOAH043MSS00.6H04STGH040MSS VDOAH043MSS0001H04STGH040MSS VDOAH043MSS0002H04STGH040MSS VDOAH043MSS0005H04STGH040MSS VDOAH043MSS0010H04STGH040MSS
Note: S hown in UL file under Cable Assemblies using catalog number
Book 3 (14.1)
w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s
Wiring Solutions
eWD-79
Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors Dimensions Figure 1
mm [inches]
Figure 2
Figure 4
Figure 3
Figure 6
Figure 5
Figure 7
Book 3 (14.1)
eWD-80
Wiring Solutions
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors
Company Information Terminal Blocks
Cables with quick-disconnect plugs for Sensor Models
Power Distribution Blocks
Do not use extension cables with the cables listed below. The physical pin configurations do not match.
Wiring Accessories
Available cables include: • Industry standard M8 screw-lock connectors • Axial and right-angle connector models • 2m, 5m and 10m cable lengths • PVC (polyvinyl chloride) jacket for typical industrial applications • IP68 rated
ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors
M8 Cables with Quick-Disconnect Part Number
Price
Length
Poles
Connectors
Jacket
Dimensions
Wiring Duct
M8 Quick-Disconnects
Cable Ties
CD08-0G-020-A1
$8.75
2m (6.56 ft.)
4
Axial female
PVC
Figure 1
CD08-0W-020-C1
$8.75
2m (6.56 ft.)
4
Right-angle female
PVC
Figure 2
Wire
CD08-0G-050-A1
$10.50 5m (16.4 ft.)
4
Axial female
PVC
Figure 1
Flexible Cord
CD08-0W-050-C1
$10.50 5m (16.4 ft.)
4
Right-angle female
PVC
Figure 2
CD08-0G-100-A1
$13.25 10m (32.8 ft.)
4
Axial female
PVC
Figure 1
CD08-0W-100-C1
$13.25 10m (32.8 ft.)
4
Right-angle female
PVC
Figure 2
Dimensions (mm) Cable Specifications
M8
Use these cables if the sensor pin configuration looks like the connector pin-out below. M8 Connector
Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies
Figure 1
DC Converters
Length
2m (6.56 ft.) 5m (16.4 ft.) 10m (32.8 ft.)
Transformers and Filters
Nominal Voltage
30VAC/30VDC
Circuit Protection
Nominal Current
4A
Protection Degree Contact Body Material
PUR
Contacts Material
CuSn
Ø Outer Cable Temperature Range
Test Equipment
ABS
Housing Material Conductors Section
Tools
IEC IP67
0.25 mm2
Enclosures
Figure 2
Enclosure Climate Control
4.5 mm
Safety: Electrical Components
-5° to +70°C (23° to 158°F)
Safety: Protective Wear Terms and Conditions
Book 3 (14.1)
w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s
Wiring Solutions
eWD-81
Prices as of April 16, 2014. Check Web site for most current prices.
Accessories: Reflectors and Shutters
Company Information Drives
RL series reflectors for polarized Retroreflective photoelectric sensors (all models)
Soft Starters Motors
• S uitable for use with polarized light photoelectric sensors • S hapes and sizes for most applications •M iniature types for close mounting in multiple sensor installations • S ingle hole, dual hole and stud mounting types available • 1 0 reflectors per package
Power Transmission Motion: Servos and Steppers Motor Controls Sensors: Proximity
Installation notes
•K eep the reflector surface clean to ensure peak detection performance. This is especially true when the maximum sensing range is being used. Clean using a damp cloth. •W hen selecting a reflector, it is important to consider the ambient conditions it will be exposed to. Dusty or high humidity conditions may reduce the sensing range as much as 90%. •R eflectors should be positioned at a 90° angle to the optical axis with a tolerance of ±15°.
Sensors: Photoelectric Sensors: Encoders Sensors: Limit Switches Sensors: Current
Specifications Model Price (10 per pack)
RL102
RL103
RL104
RL105
RL106G
RL110
3
RL116
$33.50
$43.50
$43.50
$43.50
$66.00
$22.00
$24.00
% Sensing Range Using SSP
1
50%
40%
50%
50%
50%
100%
85%
% Sensing Range Using QXP
1
--
35%
60%
50%
45%
Dimensions Degree of Protection Mounting Materials
Ø26mm (1.024 in) Ø36mm (1.42 in)
100%
--
182 x 42 mm (7.17 x 1.65 in)
Ø84mm (3.31 in)
41 x 60 mm (3.54 x 2.36 in)
two Ø4.3 mm holes two Ø6mm holes
one Ø5mm hole
two M3 holes
90 x 40 mm Ø47mm (1.85 in) (3.54 x 1.5748 in)
2
IEC IP67 Customer-supplied adhesive or other mounting method required
Reflective face: PMMA Polymethylmethacrylate (acrylic); base material: ABS (Acrylonitrile-butadiene-styren)
1 Refer to individual catalog pages for detailed explanations of these photoelectric sensors. 2 Not recommended for applications involving moist air environments or water immersion. 3 All reflective sensors are shipped with an RL116 reflector.
Sensors: Pressure Sensors: Temperature Sensors: Level Sensors: Flow Switches Pushbuttons and Lights Stacklights Signal Devices Process Relays and Timers
Dimensions
Pneumatics: Air Prep
inches [mm]
Pneumatics: Directional Control Valves Pneumatics: Cylinders
1.14” 29 mm 1.38” 35 mm
Pneumatics: Tubing Pneumatics: Air Fittings
5.7 mm thickness
Appendix Book 2 Terms and Conditions
www.automationdirect.com/photoelectric
Photoelectric Sensors
Book 2 (14.1)
e101
Prices as of April 16, 2014. Check Web site for most current prices.
Accessories: Reflectors and Shutters Dimensions inches [mm]
RL116
ST0S1 through ST0S8 shutters for M18 (18mm) through-beam sensors (SSE / SSR) • Reduces the emitted beam, allowing the detection of small targets • Shutter consists of an aluminum cap and aperture with an O-ring and glass lens, which can screw onto the optical head of either the emitter or receiver. The following table shows the sensing distance and minimal detectable object.
Sensing Distance (when used with SSE / SSR Model Photoelectric switches) Model
ST0S1
ST0S2
ST0S4
ST0S6
ST0S8
Price
$13.50
$13.50
$13.50
$13.50
$9.50
1
2
4
6
8
N/A N/A
N/A N/A
1.5 2
3.5 3
6.5 4
Ø x shutter (mm) Distance (m) object (mm)
Book 2 (14.1)
e102
Photoelectric Sensors
1-800-633-0405
Prices as of April 16, 2014. Check Web site for most current prices.
Accessories: Reflectors, Adapters & Mounting Brackets RL series reflectors for polarized reflective Laser photoelectric sensors (FALN series) • Suitable for use with polarized light Laser photoelectric sensors • Sizes for most applications • Miniature types for close mounting in multiple sensor installations • 5 reflectors per package
Company Information Drives Soft Starters
Specifications Model Sensing Range Using FALN
1
Dimensions Mounting Degree of Protection
Motors
RL201
RL203
RL204
30m
7m
7m
60mm x 82mm
19mm x 60mm
20mm x 32mm
two Ø4mm holes
two Ø5mm holes
two Ø3mm holes
2
Motion: Servos and Steppers Motor Controls
IEC IP67
Materials
Power Transmission
Acrylic/polycarbonate
Sensors: Proximity
1 Refer to individual catalog pages for detailed explanations of these photoelectric sensors. 2 Not recommended for applications involving moist air environments or water immersion. Note: All reflective sensors are shipped with an RL110 reflector. Purchase additional reflectors separately.
Sensors: Photoelectric Sensors: Encoders
RL201
RL203
Sensors: Limit Switches
RL204
Sensors: Current
20mm
Sensors: Pressure
10mm
Sensors: Temperature 50mm
$27.00
Sensors: Level
60 mm
$27.00
5 mm
$27.00
(5 per pack)
(5 per pack)
Sensors: Flow Switches
(5 per pack)
Pushbuttons and Lights
ST02 plastic swivel bracket M18 (18 mm)
ST03 right-angle M18 (18 mm) beam adapter For use with M18 retroreflective and through-beam photoelectric switches (not for use with diffuse reflection sensors). Allows 90° light detection using an internal mirror set at 45° to the optical axis. Sensitivity loss is about 20-30%.
$13.50
Plastic mounting bracket for use with M18 photoelectric switches. Has a ball-joint and set screws to adjust sensor orientation. Allows orientation in all directions for retroreflective and through-beam sensors. (Will not work with C18 series).
Stacklights Signal Devices Process Relays and Timers
$8.25
Pneumatics: Air Prep Pneumatics: Directional Control Valves Pneumatics: Cylinders Pneumatics: Tubing Pneumatics: Air Fittings Appendix Book 2 Terms and Conditions
www.automationdirect.com/photoelectric
Photoelectric Sensors
Book 2 (14.1)
e103
Prices as of April 16, 2014. Check Web site for most current prices.
Accessories: Mounting Brackets ST12A axial bracket For mounting M12 (12 mm) sensors. Has two mounting holes (use 3 mm screws) and allows the rotation of an optical axis for right-beam angle adapter sensors.
Brackets
ST12C right-angle bracket Angular mounting bracket for use with M12 (12 mm) sensors. Has two mounting holes (use 3 mm screws) and allows the rotation of an optical axis for axial sensors.
Brackets
Part Number Price Description $2.00 Metal axial bracket for 12 mm sensors, 1/pk ST12A $6.00 316L stainless steel axial bracket for 12 mm sensors, 1/pk ST12A7W
Part Number Price Description $2.00 Metal right angle bracket for 12 mm sensors, 1/pk ST12C $6.00 316L stainless steel right angle bracket for 12 mm sensors, 1/pk ST12C7W
ST18A axial bracket
ST18C right-angle bracket
Mounting bracket for M18 (18mm) sensors. Has two mounting holes (use 4 mm screws) and allows the rotation of an optical axis for right-beam angle adapter sensors.
Angular mounting bracket for M18 (18 mm) sensors. Has two mounting holes (use 4 mm screws) and allows the rotation of an optical axis for axial sensors.
Brackets
Brackets
Part Number Price Description $1.25 Metal axial bracket for 18 mm sensors, 1/pk ST18A $6.00 316L stainless steel axial bracket for 18 mm sensors, 1/pk ST18A7W
Part Number Price Description $1.25 Metal right angle bracket for 18 mm sensors, 1/pk ST18C $6.00 316L stainless steel right angle bracket for 18 mm sensors, 1/pk ST18C7W
slot for M4 screw fixing slot for M4 screw fixing
Book 2 (14.1)
e104
Photoelectric Sensors
1-800-633-0405