Transcript
A C SERIES -Deep Cycle AC12-100 (12V100AH)
Specification Nomial Voltage
12V
Nomial Capacity(10HR)
100.0AH
330 3mm (12.99 inches) Length 173 2mm (6.81 inches) Width 212 2mm (8.35 inches) Container Height Total Height (with Terminal) 220 2mm (8.66 inches) Approx 30.0 Kg (66.2 Ibs)
Dimension
Approx Weight Terminal
T11
Container Material
ABS
Rated Capacity
107.2 AH/5.36A 100.0 AH/10.0A 87.7 AH/17.5A 79.5 AH/26.5A 64.6 AH/64.6A
Mai nten anc
R
MH268 66
LEOCH BATTE RY CO.,LTD. MADE IN CHINA
(20hr ,1.80V/cell,250C/77 0F) 0 0 (10hr,1.80V/cell,25 C/77 F) (5hr,1.75V/cell,250C/77 0F) (3hr,1.75V/cell,250C/77 0F) (1hr,1.60V/cell,250C/77 0F)
Max. Discharge Current
1200A (5s)
Internal Resistance
Approx 4.9mÙ
Operating Temp.Range
Discharge : -15 500C (5 1220F) Charge : 0 400C (32 1040F ) Storage : -15 400C (5 1040F)
Nominal Operating Temp. Range
25
Cycle Use
Initial Charging Current less than 30.0A.Voltage 14.4V~15.0V at 25 0 C(77 0 F)Temp. Coefficient -30mV/ 0C
Standby Use
No limit on Initial Charging Current Voltage 13.5V~13.8V at 25 0 C(77 0 F)Temp. Coefficient -20mV/ 0C
Self Discharge
Pb.
Non-spillable
BATTERY MUST BE RECYCLED
Applications Electric tools Vehicle in place of walking Lawn mowers Golf trolleys and golf cart Portable apparatus, lights and instruments; Electric toys Illumination light Fire alarms Portable power Wheelchairs Medical equipments.
3 0C (77 5 0F )
103% 40o C (104o F) 100% 25o C ( 77o F ) 86% 0o C ( 32o F ) Synergy A C series batterys may be stored for up to 6 months at 25 0 C(77 0F) and then a freshening charge is required. For higher temperatures the time interval will be shorter.
Capacity affected by Temperature
e-fr ee Sea led Lea d-ac id Batt ery
Warnin g: Risk of fire, explos ion, or burns . Do heat above the 50 O C, or not disass emble , incine rate.
VdS
t est ed
9 0
Germany
0
Constant Current Discharge (Amperes) at 25 C (77 F ) F.V/Time
10min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
146.4
123.2
107.7
77.5
61.5
49.9
31.0
24.2
19.6
15.9
13.9
11.3
9.4
5.31
1.80V/cell
187.1
148.9
127.3
91.4
71.6
55.9
33.9
26.0
20.9
17.1
14.9
12.0
10.0
5.36
1.75V/cell
205.6
162.6
136.9
94.9
74.3
58.5
35.1
26.5
21.4
17.5
15.3
12.2
10.1
5.41
1.70V/cell
224.1
173.6
143.9
98.8
77.2
60.4
36.5
27.2
22.0
18.0
15.6
12.4
10.2
5.51
1.65V/cell
241.8
184.6
152.8
104.2
79.2
62.4
37.5
28.4
22.7
18.5
16.0
12.6
10.4
5.58
1.60V/cell
262.5
197.4
162.8
110.0
82.5
64.6
38.8
29.3
23.4
19.1
16.3
12.7
10.5
5.61
Constant Power Discharge (Watts) at 25 0C (77 0F ) F.V/Time
10min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
273.2
232.3
205.2
148.8
119.0
96.9
60.4
47.2
38.4
31.3
27.4
22.4
18.7
10.6
1.80V/cell
344.4
276.5
238.8
173.5
137.3
107.9
65.6
50.6
40.8
33.5
29.3
23.7
19.8
10.7
1.75V/cell
373.8
299.1
254.8
179.3
141.8
112.5
67.8
51.4
41.6
34.3
30.1
24.1
20.0
10.8
1.70V/cell
401.7
316.9
266.3
185.8
147.0
115.7
70.3
52.7
42.6
35.1
30.7
24.5
20.2
11.0
1.65V/cell
430.4
334.8
281.5
195.2
150.2
119.2
72.1
54.8
44.0
36.0
31.3
24.8
20.6
11.1
1.60V/cell
459.4
353.8
296.8
204.0
155.1
122.5
74.1
56.2
45.1
37.0
31.9
25.0
20.8
11.2
1
Dimensions T11 Terminal Unit: mm [inches] 20 [0.787]
173 2
220 2 212 2
7 [0.276]
M8 [0.315]
Maintenance-free Sealed Lead-acid Battery Warning: Risk of fire, explosion, or burns. Do not disassemble, O heat above the 50 C, or incinerate.
R
MH26866
Pb.
LEOCH BATTERY CO.,LTD.
Non-spillable
MADE IN CHINA
BATTERY MUST BE RECYCLED
330
Discharge Characteristics
Charging Characteristics (cycle use)
6V Battery12V Battery (V) (V)
Terminal Voltage(V)
6.5
0 Temperature 25C
Charging Characteristics Charge Volume
13.0
6.0
12.0
5.5
11.0 0.1C 0.054C 0.214C
5.0
10.0
4.5
9.0
Charging Current
Charged Voltage
% 120
(A)
(V/cell)
100
0.1C
2.5
80
0.08C
2.4
60
0.06C
2.3
40
0.04C
2.2
20
0.02C
2.1
Charge At 0.1C Amp initial charging current and 2.45V/Cell Constant o Voltage at 25C
Charged Volume
Charge Voltage (Constant 2.45v/cell)
0.365C 3.8C
4.0
3
2.6C
1.1C
0.646C
After 50% Discharge
8.0
1
4
2
6 8 10 min
20
40 60
4
2
6 8 10 H
After 100% Discharge
Charging Current (initial at 0.1c Amp)
0C
20
0
4
8
12
16
20
24
28
Charging Time(hours)
Discharge Time
Temperature Effects in Relation to Battery Capacity
Cycle Life in Relation to Depth of Discharge Testing condition Discharging:current 0.17C (FV 1.7V/cell); Charging:current 2.45V/cell,max. 0.25CA; Charging volume:125% of discharged capacity.
120 120
0.1CA 0.12CA 0.21CA
80
1CA
60
2CA 3CA
100 80
Capcity(%)
Capacity (%)
100
40 20
60
100% DOD
50% DOD
30% DOD
40 20
0 -20
-10
10
0
20
30
40
0
50
0
Temperature(0C)
200
400
600
800
1000 1200 1400 1600 1800
Number of Cycles
Self Discharge Characteristics 100
Remaining Capacity(%)
100C
80
A
A
0
25 C
B
60 30 C
40 C
40
Supplementary charge required before use.Optional charging way as below:
0
0
No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.)
B
2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell.
C
20
1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 3.Charged for 8~10hours at limted current 0.05CA .
0 0
2
4
6
8
10
C
12
Storage Time(Months)
Sales Office Innovative Energies Ltd 1 Heremai Street, Auckland, New Zealand Ph: +64 9 8350700 Email:
[email protected] www.innovative.co.nz 2
Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached.