Preview only show first 10 pages with watermark. For full document please download

Ac6471 Switching Module With A Test Point

   EMBED


Share

Transcript

PRODUCT SPECIFICATION Kari Mäki AC6471471 2.9.2010 1(2) AC6471 SWITCHING MODULE WITH A TEST POINT This product is used in AC8800 optical node instead of normal switching module AC6470. At the output there is a test point connection. Out coming signal of optical receiver can be measured there before mid-stage slope and gain controls. AC8800 software must have a version 1.4.0 when this product is used. Adapter cable (SMB=>f) BFB015 is available. Technical specifications Parameter Specification Note Signal parameters Frequency range Return loss Feed through loss Tap loss Nominal signal level 47…1006 MHz 20 dB 0.7 dB 17 dB 54 dBuV General Test point connector Supply voltages Dimensions SMB male, 75 Ω 24 V / 0 mA 12 V / 0 mA 3 V / 0.01 mA 12 x 33 x 27 mm 1 PRODUCT SPECIFICATION Kari Mäki 2.9.2010 AC6471471 2(2) Notes 1) This is the nominal output level measured at tp. Optical receiver AC6610 is having a nominal output level 72.5 dBuv in this case. Block diagram TP Rx1 Rx2 To motherboard