Preview only show first 10 pages with watermark. For full document please download

Accelink Triplexer - Anshan Topticom Tele

   EMBED


Share

Transcript

10Gb/s SFP+ Optical Transceiver (TTP-10G-SR) SFP+,LC, +3.3V 850nm, VECSEL Features:           Hot-pluggable SFP+ footprint Supports 9.95 to 11.3 Gb/s Power dissipation < 1W RoHS-6 compliant (lead-free) Commercial temperature rang 0°C to 70°C Single 3.3Vpower supply Maximum link length of 300m on 2000 MHZ-km MMF Uncooled 850nm VCSEL laser, Duplex LC connector Receiver limiting electrical interface Built-in digital diagnostic functions Applications:  10GBASE-SR/SW 10G Ethernet  Data Center  SONET/SDH Description: Topticom’s TTP-10G-SR SFP+ transceivers are designed for use in 10-Gigabit Ethernet links over multimode fiber. They are compliant with SFF-8431, SFF-8432 and IEEE 802.3ae 10GBASE-SR/SW. Digital diagnostics functions are available via a 2wire serial interface, as specified in SFF-8472 Specification: Pin Descriptions Pin Symbol 1 2 3 4 5 6 7 VEET TFAULT TDIS SDA SCL MOD_ABS RS0 8 9 10 11 12 13 14 15 RX_LOS RS1 VEER VEER RDRD+ VEER VCCR Name/Description Ref. Transmitter Ground (Common with Receiver Ground) Transmitter Fault. Transmitter Disable. Laser output disabled on high or open. 2-wire Serial Interface Data Line 2-wire Serial Interface Clock Line Module Absent. Grounded within the module No connection required 1 2 3 4 4 4 Loss of Signal indication. Logic 0 indicates normal operation. No connection required Receiver Ground (Common with Transmitter Ground) Receiver Ground (Common with Transmitter Ground) Receiver Inverted DATA out. AC Coupled Receiver Non-inverted DATA out. AC Coupled Receiver Ground (Common with Transmitter Ground) Receiver Power Supply 5 1 1 1 Anshan Topticom Technology Co.,ltd Page 1 of 7 Floor 3, Building 6, Laser Industrial Park, Yueding Road, New and High-tech Zone, Anshan City, Liaoning Province, China. Tel: +86 755 3682 1780 Fax: +86 755 2161 2318 Issued Date: 2011-06-15 Web: www.topticom.com E-mail: [email protected] Http://topticom.en.alibaba.com 10Gb/s SFP+ Optical Transceiver (TTP-10G-SR) SFP+,LC, +3.3V 850nm, VECSEL 16 17 18 19 20 VCCT VEET TD+ TDVEET Transmitter Power Supply Transmitter Ground (Common with Receiver Ground) Transmitter Non-Inverted DATA in. AC Coupled. Transmitter Inverted DATA in. AC Coupled. Transmitter Ground (Common with Receiver Ground) 1 1 Notes: 1. 2. Circuit ground is internally isolated from chassis ground. Tfault is an open collector/drain output, which should be pulled up with a 4.7k – 10k Ohms resistor on the host board if intended for use. Pull up voltage should be between 2.0V to Vcc + 0.3V. A high output indicates a transmitter fault caused by either the TX bias current or the TX output power exceeding the preset alarm thresholds. A low output indicates normal operation. In the low state, the output is pulled to <0.8V. 3. Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V. 4. Should be pulled up with 4.7kΩ – 10kΩon host board to a voltage between 2.0V and 3.6V. MOD_ABS pulls line low to indicate module is plugged in. 5. LOS is open collector output. Should be pulled up with 4.7kΩ – 10kΩon host board to a voltage between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal. Pin out of Connector Block on Host Board Absolute Maximum Ratings Exceeding the limits below may damage the transceiver module permanently. Symbol Min Max Unit Ref. Maximum Supply Voltage Storage Temperature Case Operating Temperature Parameter Vcc TS TA -0.5 -40 0 Typ 4.0 85 70 Relative Humidity RH 0 85 V °C °C % 1 Electrical Characteristics (TOP = 0 to 70 °C, VCC = 3.14 to 3.46 Volts) Parameter Supply Voltage Supply Current Symbol Min Vcc Icc 3.14 Typ Max Unit 3.46 250 V mA Ref. Transmitter Input differential impedance Rin 100 Ω 1 Anshan Topticom Technology Co.,ltd Page 2 of 7 Floor 3, Building 6, Laser Industrial Park, Yueding Road, New and High-tech Zone, Anshan City, Liaoning Province, China. Tel: +86 755 3682 1780 Fax: +86 755 2161 2318 Issued Date: 2011-06-15 Web: www.topticom.com E-mail: [email protected] Http://topticom.en.alibaba.com 10Gb/s SFP+ Optical Transceiver (TTP-10G-SR) SFP+,LC, +3.3V 850nm, VECSEL Differential data input swing Transmit Disable Voltage Transmit Enable Voltage Vin,pp VD VEN 180 2 Vee 700 Vcc Vee+ 0.8 mV V V Differential data output swing Vout,pp 300 850 mV 2 Data output rise time, fall time LOS Fault LOS Normal Power Supply Noise Tolerance tr VLOS fault VLOS norm VccT/VccR ps V V mVpp 3 4 4 5 Receiver 28 VccHOST 2 Vee Vee+0.8 Per SFF-8431 Rev 2.1 Notes: 1. 2. 3. Connected directly to TX data input pins. AC coupling from pins into laser driver IC. Into 100Ω differential termination. 20 – 80 % . Measured with Module Compliance Test Board and OMA test pattern. Use of four 1’s and four 0’s in sequence in the PRBS^9 is an acceptable alternative. SFF-8431 Rev 2.1 4. LOS is an open collector output. Should be pulled up with 4.7kΩ – 10kΩ on the host board. Normal operation is logic 0; loss of signal is logic 1. Maximum pull-up voltage is 5.5V. 5. Testing methodology per SFF-8431. Rev 2.1 Optical Characteristics (TOP = 0 to 70 °C, VCC = 3.14 to 3.46 Volts) Parameter Symbol Min Typ Max Unit Ref. dBm 1 -1 860 0.45 dBm nm dB 2 1 1 3.9 dB dB -30 dBm Transmitter Optical Modulation Amplitude (OMA) Average Launch Power Optical Wavelength RMS Spectral Width Optical Extinction Ratio Transmitter and Dispersion Penalty Average Launch power of OFF transmitter Tx Jitter Encircled Flux Relative Intensity Noise POMA PAVE λ Δ λ rms ER TDP -1.5 -5 840 850 3.0 5.5 POFF Txj <4.5μm <19μm RIN12OMA Per IEEE 802.3ae requirements 30 86 % -128 dB/Hz -11.1 dBm -7.5 dBm 3 Receiver Receiver Sensitivity (OMA) @ 10.3Gb/s Stressed Receiver Sensitivity (OMA) @ 10.3Gb/s Maximum Input Power Wavelength Range RSENS1 RSENS2 Receiver Reflectance LOS De-Assert LOS Assert LOS Hysteresis PMAX λ C Rrx LOSD LOSA +0.5 840 860 -12 -14 -30 0.5 -23 4 5 dBm nm dB dBm dBm dB Notes: Anshan Topticom Technology Co.,ltd Page 3 of 7 Floor 3, Building 6, Laser Industrial Park, Yueding Road, New and High-tech Zone, Anshan City, Liaoning Province, China. Tel: +86 755 3682 1780 Fax: +86 755 2161 2318 Issued Date: 2011-06-15 Web: www.topticom.com E-mail: [email protected] Http://topticom.en.alibaba.com 10Gb/s SFP+ Optical Transceiver (TTP-10G-SR) SFP+,LC, +3.3V 850nm, VECSEL 1. 2. 3. Per Tradeoff Table 52.8, IEEE 802.3ae 2005 Average Power figures are informative only, per IEEE802.3ae. Measured into Type A1a (50/125 μm multimode) fiber per ANSI/TIA/EIA-455-203-2. 4. 5. Measured with worst ER; BER<10 ; 2 – 1 PRBS. Per IEEE 802.3ae. -12 31 General Specifications Parameter Symbol Min Typ BR BER 9.95 10.3 Bit Rate Bit Error Ratio Max Units Ref. Gb/s 1 2 10-12 Maximum Supported Distances 850nm OFL Bandwidth 160 MHz-km Fiber Type 62.5μm OM1 200 MHz-km 26 Lmax 33 400 MHz-km OM2 500 MHz-km 50μm m 66 82 Lmax OM3 2000 MHz-km m 300 Notes: 1. 10GBASE-SR/SW. Contact XGIGA’s for higher data-rate support. 31 2. Tested with a 2 – 1 PRBS Environmental Specifications TOPTICOM’s 850nm SFP transceivers have a commercial operating temperature range from 0°C to +70°C case temperature. Symbol Min Max Units Case Operating Temperature Parameter Top 0 Typ 70 °C Storage Temperature Tsto -40 85 °C Ref. Regulatory Compliance TOPTICOM’s transceivers are Class 1 Laser Products and comply with US FDA regulations. These products are certified by TÜV and CSA to meet the Class 1 eye safety requirements of EN (IEC) 60825 and the electrical safety requirements of EN (IEC) 60950. Copies of certificates are available at TOPTICOM’s Corporation upon request. Anshan Topticom Technology Co.,ltd Page 4 of 7 Floor 3, Building 6, Laser Industrial Park, Yueding Road, New and High-tech Zone, Anshan City, Liaoning Province, China. Tel: +86 755 3682 1780 Fax: +86 755 2161 2318 Issued Date: 2011-06-15 Web: www.topticom.com E-mail: [email protected] Http://topticom.en.alibaba.com 10Gb/s SFP+ Optical Transceiver (TTP-10G-SR) SFP+,LC, +3.3V 850nm, VECSEL Digital Diagnostic Functions TOPTICOM’s TTP-10G-SR SFP+ transceivers support the 2-wire serial communication protocol as defined in 2 the SFF-8472. It is very closely related to the E PROM defined in the GBIC standard, with the same electrical specifications. The standard SFP+ serial ID provides access to identification information that describes the transceiver’s capabilities, standard interfaces, manufacturer, and other information. Additionally, TOPTICOM’s SFP+ transceivers provide a enhanced digital diagnostic monitoring interface, which allows real-time access to device operating parameters such as transceiver temperature, laser bias current, transmitted optical power, received optical power and transceiver supply voltage. It also defines a sophisticated system of alarm and warning flags, which alerts end-users when particular operating parameters are outside of a factory set normal range. 2 SFF-8472 defines a 256-byte memory map in E PROM that is accessible over a 2-wire serial interface at the 8 bit address 1010000X (A0h). The digital diagnostic monitoring interface makes use of the 8 bit address 1010001X (A2h), so the originally defined serial ID memory map remains unchanged. The interface is identical to, and is thus fully backward compatible with both the GBIC Specification and the SFP Multi Source Agreement. The operating and diagnostics information is monitored and reported by a Digital Diagnostics Transceiver Controller (DDTC) inside the transceiver, which is accessed through a 2-wire serial interface. When the serial protocol is activated, the serial clock signal (SCL, Mod Def 1) is generated by the host. The positive edge clocks 2 data into the SFP transceiver into those segments of the E PROM that are not write-protected. The negative edge clocks data from the SFP transceiver. The serial data signal (SDA, Mod Def 2) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially. For more information, please see the SFF-8472 documentation. Digital Diagnostic Specifications TTP-10G-SR transceivers can be used in host systems that require either internally or externally calibrated digital diagnostics. Parameter Symbol Min Typ Max Units Ref. Accuracy Internally measured transceiver temperature Internally measured transceiver supply voltage Measured TX bias current Measured TX output power Measured RX received average optical power DDTemperature -3 3 ºC DDVoltage -100 100 mV DDBias DDTx-Power -10 -2 10 2 % dB DDRx-Power -2 2 dB DDTemperature 0 70 ºC DDVoltage 3.14 3.46 V DDBias 0 20 mA 1 Dynamic Range for Rated Accuracy Internally measured transceiver temperature Internally measured transceiver supply voltage Measured TX bias current Anshan Topticom Technology Co.,ltd Page 5 of 7 Floor 3, Building 6, Laser Industrial Park, Yueding Road, New and High-tech Zone, Anshan City, Liaoning Province, China. Tel: +86 755 3682 1780 Fax: +86 755 2161 2318 Issued Date: 2011-06-15 Web: www.topticom.com E-mail: [email protected] Http://topticom.en.alibaba.com 10Gb/s SFP+ Optical Transceiver (TTP-10G-SR) SFP+,LC, +3.3V 850nm, VECSEL Measured TX output power Measured RX received average optical power DDTx-Power -9 -2.5 dBm DDRx-Power -20 0 dBm DDTemperature -40 125 ºC DDVoltage 2.8 4.0 V DDBias DDTx-Power 0 -10 20 -3 mA dBm DDRx-Power -22 0 dBm Max Reporting Range Internally measured transceiver temperature Internally measured transceiver supply voltage Measured TX bias current Measured TX output power Measured RX received average optical power Notes: 1. Accuracy of Measured Tx Bias Current is 10% of the actual Bias Current from the laser driver to the laser. Mechanical Specifications Mechanical Dimensions Anshan Topticom Technology Co.,ltd Page 6 of 7 Floor 3, Building 6, Laser Industrial Park, Yueding Road, New and High-tech Zone, Anshan City, Liaoning Province, China. Tel: +86 755 3682 1780 Fax: +86 755 2161 2318 Issued Date: 2011-06-15 Web: www.topticom.com E-mail: [email protected] Http://topticom.en.alibaba.com 10Gb/s SFP+ Optical Transceiver (TTP-10G-SR) SFP+,LC, +3.3V 850nm, VECSEL Recommended Circuit: Anshan Topticom Technology Co.,ltd Page 7 of 7 Floor 3, Building 6, Laser Industrial Park, Yueding Road, New and High-tech Zone, Anshan City, Liaoning Province, China. Tel: +86 755 3682 1780 Fax: +86 755 2161 2318 Issued Date: 2011-06-15 Web: www.topticom.com E-mail: [email protected] Http://topticom.en.alibaba.com