A C C E S S C ON T R O L
WARRANTY All Fermax products have a 24 months warranty. Fermax«obligation under this warrany, however, is expressly limited (at Fermax«option) to replacing, repairing, or issuing credit for any product returned to FERMAX within twenty four (24) months from date of shipment by FERMAX and then only if: (a) the defective product is returned to FERMAX, transport charges prepaid, (b) examination of the product discloses to FERMAX«satisfaction that defects in the product have not been caused by misuse, neglect, improper installation, repair alteration or accident and (c) returned material must attach the Authorization for return form. This warranty does not cover problems arising due causes with equipment (for example deficiencies in installation or incorrect wiring), nor breakdowns caused by incorrect manipulation of blows. LIMIT OF LIABILITY It is expressly understood and agreed that FERMAX is not an insurer that the products or services sold hereunder will perform functions or prevent: that FERMAX shall be exempt from liability for all loss or damage therefrom; and that insurance, if any, shall be obtained by the Distributor. Liability shall be limited to an amount to the consideration paid by the distributor for such products or services as the distributor exclusive remedy. DELIVERY 15 days after order confirmation and reception of payment. Allow 30 days for special orders. Every endeavour will be made by the Company to adhere to the delivery dates quoted, but such dates are only estimate and are not guaranteed neither shall they be a term of condition between the Buyer and the Company. The Buyer shall be responsible for arranging insurance on goods collected by their own carriers. Delay in delivery shall by no means entitle the Buyer to cancel the order or thereby render the Seller liable to the Buyer for any loss or expense arising from the delay unless otherwise agreed in writing. Ex works. ˚ OWNIRSHIP OF GOODS The goods shall remain the property of the Seller until paid for in full by the Buyer. CANCELLATION Cancellation of any order or goods or any part of an order will not be valid after the Buyer has placed the order unlessthe cancellation is accepted by the Seller in writing.
Dear partner, This fourth edition of the Access Control catalogue takes in the complete range of FERMAX solutions for access restriction. You can choose the most suitable option according to the specific needs and features of the installation: • Styling: for interiors, outdoors or vandal-proof version. • Reader technology: keypad, proximity, radio frequency, fingerprint and Bluetooth. • System: Stand-alone (1 access), stand-alone in network (32 accesses) and centralized (large installations). This new document has been designed to provide you with detailed and structured information on all the options, in technical file format, for easy understanding and use by the professional.
The main new features that you will find in this edition are: • Stand-alone system. The Bluetooth Kit lets you open the door with a mobile phone. It is a technological and innovating product. City Fingerprint Reader. Cutting-edge technology now at a highly competitive price. Includes thermal reader technology, recommended in exteriors. Storage capacity: 950 fingerprints. Marine Readers for exteriors made in stainless steel, now available in keypad version (Memokey) and proximity (Private). New RF remote control line with an exclusive design and more robust mechanics. We emphasize the versatility offered by our access control range for integration in any video entry system panel. Ask for the modular format of the desired reader and integrate it in an outdoor panel. • Stand-alone system in network. Recommended for average size applications - up to 32 accesses and 1000 users. Management handled from intuitive and practical PC software. An interesting balance between benefits and simplicity in system management and start-up.
• Centralized system. The new software that comes as standard with the Central Unit also includes management of user authorizations/cancellations and access permits/restrictions and now also time & attendance software for staff clock-in management and calculation of hours worked (for pays management). You can also find all updated information on our products in the product section of our website www.fermax.com. Thank you for your confidence.
Jeremy Palacio Access Control Product Manager
Stand-alone
1 1
Stand-alone in network
37
Centralized
49
Accessories
75
Content Guide
QUICK GUIDE Keypad
Description STAND-ALONE STAND-ALONE KIT STAND-ALONE IN NETWORK CENTRALIZED
City
Bruto
Loft
ref.
ref.
ref.
3610 3600 4480 23291
Citymax Module Description STAND-ALONE STAND-ALONE KIT STAND-ALONE IN NETWORK CENTRALIZED
4500 2133 2553
4540 3623 4550 4550+4420
Bruto Module
Marine
ref.
ref.
ref.
2520 2561
2523 22371
4699 -
Proximity
City Description STAND-ALONE STAND-ALONE KIT STAND-ALONE IN NETWORK CENTRALIZED
STAND-ALONE STAND-ALONE KIT STAND-ALONE IN NETWORK CENTRALIZED
06
Loft
ref.
ref.
ref.
2347 2260 4490 23351
4520 4510 2552
4530 3624 4560
or 4490+4420
or 4510+4420
Citymax Module Description
Bruto
Bruto Module
4560+4420
Marine
ref.
ref.
ref.
2263 2560
2288 2268
4698 -
QUICK GUIDE Radio frequency
Box Receiver
PCB Module Description
ref.
7900 STAND-ALONE STAND-ALONE KIT STAND-ALONE IN NETWORK CENTRALIZED
DIN Rail MDS
Single Channel Receiver
MDS Secondary Receiver
ref.
ref.
ref.
ref.
7960 7912 -
7903 7910 -
7952 7911 1065
2464
Key button
City ref.
ref.
2315 23261
2554
Description STAND-ALONE STAND-ALONE KIT STAND-ALONE IN NETWORK CENTRALIZED
Bruto
or 2315+4420
Bluetooth
Bluetooth
TM
Bluetooth
Description STAND-ALONE STAND-ALONE KIT STAND-ALONE IN NETWORK CENTRALIZED
TM
City
Citymax Module
ref.
ref.
4477 4478 -
4476 -
Fingerprint
City
Citymax Module
ref.
ref.
ref.
-
6990 6988 6990
6989 6989
4470+4420
6990+4420
6989+4420
Optical Reader Description STAND-ALONE STAND-ALONE KIT STAND-ALONE IN NETWORK CENTRALIZED
07
Stand-alone - The easiest access control to install. No PC required. An ideal access control solution for indoors and outdoors, to manage a single access or door in the most practical and simple way. Swift and easy to install: only two power supply cables. Reader technologies available are keypad, proximity readers, radio frequency systems, Bluetooth technology and digital fingerprint.
Stand-alone in network - Secure and practical access control. PC required. The stand-alone access control system in network is recommended when you want to manage permits/restrictions for up to 32 accesses or doors from a PC. The on–line events record enables a fast graphic view of incoming and outgoing user flow.
Centralized - The most complete and versatile solution. PC Required. Enables complete management of an installation with multiple accesses (up to 2048) and advanced access control functions. There are two systems: MDS and CAC. MDS is recommended in installations with audio or video door entry systems and access control functions, alarms and automation. CAC is the best option for purely access control installations thanks to its new functions: vehicle control and time & attendance for salary management. Also includes alarms management and automation.
Accessories - Common to all the access control systems. 08
Reference chart/index
READER
STAND-ALONE R
E
F
STAND-ALONE IN NETWORK E
R
E
N
CENTRALIZED (MDS and CAC) C
E
S
KEYPAD 4480 * (0)
CITY
3610
CITYMAX MODULE
2520
-
2561
BRUTO
4500
-
2553
BRUTO MODULE
2523
-
22371
LOFT
4540
MARINE
4699
-
-
CITY
2347
4490
23351 o 4490+4420
CITYMAX MODULE
2263
-
2560
BRUTO
4520
4510
2552 o 4510+4420
BRUTO MODULE
2288
-
2268
LOFT
4530
4560
4560+4420
MARINE
4698
-
-
CITY
-
2315
23261 o 2315+4420
CITYMAX MODULE
-
-
-
BRUTO
-
-
2554
BRUTO MODULE
-
-
-
PCB MODULE RECEIVER
7900
-
-
BOX RECEIVER
7960
-
-
DIN RAIN MODEL RECEIVER
7903
-
-
SINGLE CHANNEL RECEIVER
7952
-
1065
MDS SECUNDARY RECEIVER
-
-
2464
CITY
4477
-
-
CITYMAX MODULE
4476
-
-
-
-
4470+4420
CITY N
6990
6990
6990+4420
CITYMAX MODULE
6989
6989
6989+4420
4550 *(1)
23291
4550* (1)+4420
PROXIMITY
KEY BUTTON
RADIOFREQUENCY
BLUETOOTH
FINGERPRINT OPTICAL READER A
NOTE: The symbol “-” indicates that there is no such combination. *(0) Ref.4480 is a keypad and proximity reader. *(1) Ref.4550 is a keypad and proximity reader.
09
Simple access control system managing one access.
Stand-alone access control
STAND-ALONE
Memokey stand-alone
City Memokey (ref.3610) Access control keypad with capacity for up to 100 different of 4 to 6-digit codes. Manufactured in aluminium. Flush or surface mounted (ref.8851). Recommended for interiors and exteriors. Reader and controller in the same module (ref.3610) or separate (ref.3620 and ref.3621).
Technical features
Programming
Installation
230Vac Power supply
Exit pushbutton and free access button input. Electric lock activation by relay. With auxiliary relay for other functions. Programmable relay times (monostable, bistable). Each code can activate one or two relays simultaneously. Multi-function OC output: coercion alarm, wrong code or tamper.
Programming from the keypad by Master code.
Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.
2
2
Door release
1
2
3
4
5
6
7
8
9
A
0
B
Ref.3610 2
Exit button
Specifications
12
Dimensions (WxHxDmm): 130x128x18 Flush box (included): 115x114x45 Surface box (WxHxDmm): 130x128x33 Environmental protection (IP): 43 Protection against knocks (IK): 07
Power supply (V): 12V (ac/dc) Consumption (mA) without door release: 6/60 Relay Contact: 2A (NA,NC) Programmable from 01 to 99 sec. or bistable Operating temperature: 0 to 70ºC
Available in kit (ref.3600)
STAND-ALONE
Memokey stand-alone
City Memokey CR (ref.3620+3621)
Memokey City CR (ref.3620)
Memokey controller CR (ref.3621)
Technical features
Programming
Installation 2
230Vac Power supply
Reader (ref.3620) and controller (ref.3621) in two stand-alone modules for enhanced security. The controller is installed indoors next to the power supply and door release. Metallic box included with controller (measurements: 154x203x50mm). A second CR keypad can be added on the inside. Maximum distance: 100 meters.
Exit pushbutton and free access button input. Electric lock activation by relay. With auxiliary relay for other fuctions. Programmable relay times (monostable, bistable). Each code can activate one or two relays simultaneously. Multi-function OC output: coercion alarm, wrong code or tamper. Electric lock unblocking by code (free access).
Programming from keypad by Master code.
The CR keypad is located on the outside, connected to the controller situated in the interior, the same as the rest of the devices: power supply and electric lock. Optionally, an exit pushbutton can be used (if there is no door handle) and a second CR keypad on the inside.
2
Ref.3620 1
2
3
4
5
6
7
8
9
A
0
B
6
Ref.3621
2
2
Exit button
Door release
Specifications
Available in kit (ref.3591)
Dimensions (WxHxDmm): 130x128x18 Flush box (included): 115x114x45 Surface box (WxHxDmm): 130x128x33 Metallic box (WxHxDmm): 154x203x50 Environmental protection (IP): 43 Protection against knocks (IK): 07
Power supply (V): 12V (ac/dc) Consumption (mA) without door release: 6/60 Relay contact: 2A (NA,NC) Programmable from 01 to 99 sec. or bistable Operating temperature: 0 to 70ºC
13
STAND-ALONE
Memokey stand-alone
City Memokey Module (ref.2520) Access control keypad with capacity for up to 100 different 4 to 6-digit codes. Manufactured in aluminium. To be fitted in CityMax audio or video door entry system outdoor panels to improve home security. Reader and controller integrated in the same module (ref.2520).
Technical features
Programming
Installation 230Vac Power supply
Exit pushbutton and free access button input. Electric lock activation by relay. With auxiliary relay for other functions. Programmable relay times (monostable, bistable). Each code can activate one or two relays simultaneously. Open collector auxiliary output (150mA max) to indicate sabotage attempt or door open/forced. Electric lock unblocking by code (free access).
Programming from keypad by Master code.
Audio or video door entry panel located in the outside area. It is possible to set up the panel intuitively to include a keypad (ref.2520) for greater security and more convenient access.
2
2
Door release 1
2
3
4
5
6
7
8
9
A
0
B
Ref.2520 2
Exit button
Specifications
14
Environmental protection (IP): 43 Protection against knocks (IK): 07 Power supply (V): 12V (ac/dc) Consumption (mA) without door release: 6/60 Relay contact: 2A (NA,NC) Programmable from 01 to 99 sec. or bistable Operating temperature: 0 to 70ºC
STAND-ALONE
Memokey stand-alone
Bruto Memokey (ref.4500) Access control keypad with capacity for up to 100 different 4 a 6-digit codes. Vandal-proof panel. Flush or surface mounted (ref.2778). Recommended for interiors and exteriors. Reader and controller integrated in the same module. Ideal for troubled zones or districts, offices, banks, etc.
Technical features
Programmation
Installation 230Vac Power supply 2
2
1
2
3
A
4
5
6
0
7
8
9
B
Door release
Programming from keypad by Master code.
Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.
Ref.4500 2
Exit button
Specifications
Available in kit (ref.2133)
Exit pushbutton and free access button input. Electric lock activation by relay. With auxiliary relay for other functions. Programmable relay times (monostable, bistable). Each code can activate one or two relays simultaneously. Multi-function OC output: coercion alarm, wrong code or tamper.
Dimensions (WxHxDmm): 135x130x18 Flush box (included): 115x100x45 Surface box(WxHxDmm): 135x131x42 Environmental protection (IP): 53 Protection against knocks (IK): 09
Power supply (V): 12V (ac/dc) Consumption (mA) without door release: 6/60 Relay contact: 2A (NA,NC) Programmable from 01 to 99 sec. or bistable Operating temperature: 0 to 70ºC
15
STAND-ALONE
Memokey stand-alone
Bruto Memokey Module (ref.2523) Access control keypad with capacity for up to 100 different 4- to 6-digit codes. Vandal-proof keypad. To be fitted in Bruto audio or video door entry panel viewers for enhanced security in the home. Reader and controller integrated in the same module (ref.2523).
Technical features
Programmation
Installation
230Vac
Exit pushbutton and free access button input. Electric lock activation by relay. With auxiliary relay for other functions. Programmable relay times (monostable, bistable). Each code can activate one or two relays simultaneously. Multi-function OC output: coercion alarm, wrong code or tamper.
Programming from keypad by Master code.
Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.
Power supply 2
2
Door release Ref.2523 2
Exit button
Specifications
16
Environmental protection (IP): Protection against knocks (IK): Power supply (V): Consumption (mA) without door release: Relay contact: Programable from 01 to 99 sec. or bistable Operating temperature:
53 09 12V (ac/dc) 6/60 2A (NA,NC) 0 to 70ºC
STAND-ALONE
Memokey stand-alone
Loft Memokey (ref.4540) Access control keypad with capacity for up to 100 different 4 to 6-digit codes. Manufactured in ABS plastic. Surface mounted. Recommended for interiors. Reader and controller integrated in the same module Ideal for screen profiles in offices. Includes a 50cm cable.
Technical features
Programmation
Installation 2 230Vac
Exit pushbutton and free access button input. Electric lock activation by relay. Multi-function OC output: coercion alarm, wrong code and forced door. Electric lock unblocking by code (free access). Status LEDs: door open/closed/power supply.
Programming from keypad by Master code.
Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.
Power supply 2
2
Ref.4540 1
2
3
4
5
6
7
8
9
A
0
B
Door release
2
Exit button
Specifications
Availalble in kit (ref.3623)
Dimensions (WxHxDmm): 60x130x23 Flush box: Not required Superface box (WxHxDmm):Not required Environmental protection (IP): 66 Protection against knocks (IK): 06
Power supply (V): 12V (ac/dc) Consumption (mA) without door release: 20/70 Relay contact: 2A (NA,NC) Operating temperature: 0 to 70ºC
17
STAND-ALONE
Memokey stand-alone
Marine Memokey (ref.4699) Access control keypad with capacity for up to 100 different 4- to 6-digit codes. Stainless steel panel 2.5mm thickness. Keypad with 4x3 layout and orange backlight. Flush or surface mounted (ref.4645). Recommended for interiors and exteriors. Reader and controller integrated in the same module.
Technical features
Programmation
Installation 230Vac Power supply
Exit pushbutton and free access button input. Electric lock activation by relay. With auxiliary relay for other functions. Programmable relay times (monostable, bistable). Each code can activate one or two relays simultaneously. Multi-function OC output: coercion alarm, wrong code or tamper.
Programming from keypad by Master code.
Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.
2
2
Door release
1
2
3
4
5
6
7
8
9
0
B
A
Ref.4699 2
Exit button
Specifications
18
Dimensions (WxHxDmm): 153x123x50 Flush box (included): 130x160x55 Superface box (WxHxDmm):154x184x73 Environmental protection (IP): 53 Protection against knocks (IK): 09
Power supply (V): 12V (ac/dc) Consumption (mA) without door release: 6/60 Relay contact: 2A (NA,NC). Programmable from 01 to 99 sec. or bistable Operating temperature: 0 to 60ºC
STAND-ALONE
Private stand-alone
City Private (ref.2347) Proximity card reader with capacity for up to 400 users. Manufactured in aluminium. Flush or surface mounted (ref.8851). Recommended for interiors and exteriors. Reader and controller integrated in the same module.
Technical features
Programmation
Installation 2 230Vac Power supply
Exit pushbutton and free access button input. Electric lock activation by relay with programmable timing. Programming help LEDs.
Can be done in 3 ways: Master card: The first time that the power supply is connected, the system waits for a proximity card which will be considered as “master card”. Keypad: Recommended if we want to cancel lost cards (ref. 2306). PC software: The most convenient solution for authorization and cancellation management (ref.2351).
Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.
2
2 Ref.2347
( restricted area ) PRIVATE ACCESS CONTROL
Door release
2
Exit button
Identifiers Specifications
Available in kit (ref.2260)
Without Without Customizable personalizing personalizing and (photo, name, or magnetic strip. with magnetic strip. company...)
ref.23361
ref.2336
For replacement with magnetic strip.
Proximity keyring.
ref.2364
ref.44501
ref.2336
Dimensions (WxHxDmm): 130x128x18 Flush box (included): 115x114x45 Superface box (WxHxDmm):130x128x33 Environmental protection (IP): 43 Protection against knocks (IK): 07 Power supply (V): 12V (ac/dc) Cons. (mA) without door release: 80/120
Relay contact:
2A (NA,NC). Programmable from 01 to 99 sec. or bistable Operating temperature: 0 to 60ºC Reading distance (card/keyring): 6/5 cm IP Interface: RS-232
19
STAND-ALONE
Private stand-alone
City Private Module (ref.2263) Proximity card reader with capacity for up to 400 users. To be fitted in the viewer of CityMax audio or video door entry panels for enhanced security in the home. Reader and controller integrated in the same module.
Technical features
Exit pushbutton and free access button input. Electric lock activation by relay with programmable timing. Programming help LEDs.
Programmation
Can be done in 3 ways: Master card: The first time that the power supply is connected, the system waits for a proximity card which will be considered as “master card”. Keypad: Recommended if we want to cancel lost cards (ref. 2306). PC software: The most convenient solution for authorization and cancellation management (ref.2351).
Installation
The audio or video door entry panel is located in the outside area. It is possible to set up the panel intuitively to include a keypad (ref.2263) for greater security and more convenient access.
2 230Vac Power supply 2
2
( restricted area )
Door release
PRIVATE ACCESS CONTROL
Ref.2263 2
Exit button
Identifiers Specifications
20
Without Without Customizable personalizing personalizing and (photo, name, or magnetic strip. with magnetic strip. company...)
ref.23361
ref.2336
ref.2336
Environmental protection(IP): 43 Protection against knocks (IK): 07 Power supply (V): 12V (ac/dc) Cons. (mA) withot door release: 80/120 Relay contact: 2A (NA,NC).
For replacement with magnetic strip.
ref.2364
Operating temperature: Reading distance (card/lkeyring): PC Interface:
Proximity keyring.
ref.44501
0 to 60ºC 6/5 cm RS-232
STAND-ALONE
Private stand-alone
Private Bruto (ref.4520) Proximity card reader with capacity for up to 400 users. Vandal-proof reader. To be fitted in the viewer of the Bruto audio or video door entry panels for enhanced security in the home. Reader and controller integrated in the same module.
Technical features
Exit pushbutton and free access button input. Electric lock activation by relay with programmable timing. Programming help LEDs.
Programmation
Can be done in 3 ways: Master card: The first time that the power supply is connected, the system waits for a proximity card which will be considered as “master card”. Keypad: Recommended if we want to cancel lost cards (ref. 2306). PC software: The most convenient solution for authorization and cancellation management (ref.2351).
Installation
Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.
2 230Vac Power supply 2
2 ( restricted area )
Ref.4520
PRIVATE ACCESS CONTROL
Door release
2
Exit button
Identifiers Specifications
Without Without Customizable personalizing personalizing and (photo, name, or magnetic strip. with magnetic strip. company...)
ref.23361
ref.2336
For replacement with magnetic strip.
ref.2336
Dimensions (WxHxDmm): 135x130x18 Flush box (included): 115x100x45 Superface box (WxHxDmm):135x131x42 Environmental protection (IP): 53 Protection against knocks (IK): 09 Power supply (V): 12V (ac/dc) Comsumption (mA) door release 80/120
ref.2364
Proximity keyring.
ref.44501
Relay contact
2A (NA,NC). Programmable from 01 to 99 sec. or bistable Operating temperature 0 to 60ºC Reading distance: (card/keyring): 4/2 cm PC Interface: RS-232
21
STAND-ALONE
Private stand-alone
Bruto Private Module (ref.2288) Proximity card reader with capacity for up to 400 users. Vandal-proof reader. To be fitted in the viewer of the Bruto audio or video door entry panels for enhanced security in the home. Reader and controller integrated in the same module.
Technical features
Programmation
Installation 2 230Vac Power supply 2
Exit pushbutton and free access button input. Electric lock activation by relay with programmable timing. Programming help LEDs. Can be done in 3 ways: Master card: The first time that the power supply is connected, the system waits for a proximity card which will be considered as master card. Keypad: Recommended if we want to cancel lost cards. PC software: The most convenient solution for authorization and cancellation management (ref.2351).
Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.
2
Door release Ref.2288
2
Exit button
( restricted area )
PRIVATE ACCESS CONTROL
Identifications Specifications
22
Without Without Customizable personalizing personalizing and (photo, name, or magnetic strip. with magnetic strip. company...)
ref.23361
ref.2336
For replacement with magnetic strip.
ref.2363
Environmental protection (IP): 53 Protection against knocks (IK): 09 Power supply (V): 12V (ac/dc) Consumption (mA) without door release: 80/120 Relay contact: 2A (NA,NC) Programmable from 01 to 99 sec. or bistable Operating temperature: 0 to 70ºC
ref.2364
Proximity keyring.
ref.44501
STAND-ALONE
Private stand-alone
Loft Private (ref.4530) Access control keypad with capacity for up to 100 different 4 to 6-digit codes. Manufactured in ABS plastic. Surface mounted. Recommended for interiors. Reader and controller integrated in the same module Ideal for screen profiles in offices. Includes a 50cm cable .
Technical features
Exit pushbutton and free access button input. Electric lock activation by relay with programmable timing. Programming help LEDs.
Programmation
Can be done in 3 ways: Master card: The first time that the power supply is connected, the system waits for a proximity card which will be considered as master card. Keypad: Recommended if we want to cancel lost cards (ref. 2306). PC software: The most convenient solution for authorization and cancellation management (ref.3625)
Installation
Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.
2 230Vac Power supply 2
2 Ref.4530 Door release
2
Exit button
Identifiers Specifications
Available in kit (ref.3624)
Without Without Customizable personalizing personalizing and (photo, name, or magnetic strip. with magnetic strip. company...)
ref.23361
ref.2336
ref.2336
Dimensions (WxHxDmm): 60x130x23 Flush box (included): Not required Superface box (WxHxDmm): Not required 66 Environmental protection (IP): 06 Protection against knocks (IK): 12V (ac/dc) Power supply (V):
For replacement with magnetic strip.
ref.2364
Proximity keyring.
ref.44501
Cons. (mA) without door release: 45/75 Relay contact: 2A (NA,NC). Operating temperature: 0 to 60ºC Reading distance (card/keyring): 8/6 cm PC Interface: RS-485
23
STAND-ALONE
Private stand-alone
Marine Private (ref.4698) Proximity card reader with capacity for up to 400 users. Stainless steel panel 2.5mm thickness. Flush or surface mounted (ref.4645). Recommended for interiors and exteriors. Reader and controller integrated in the same module.
Technical features
Exit pushbutton and free access button input. Electric lock activation by relay with programmable timing. Programming help LEDs.
Programmation
Can be done in 3 ways: Master card: The first time that the power supply is connected, the system waits for a proximity card. which will be considered as master card. Keypad: Recommended if we want to cancel lost cards (ref.1306). PC software: The most convenient solution for authorization and cancellation management (ref.2351)
Installation
Keypad is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.
2 230Vac Power supply 2
2 ( restricted area )
Ref.4698
PRIVATE ACCESS CONTROL
Door release
2
Exit button
Identifiers
Without Without Customizable personalizing personalizing and (photo, name, or magnetic strip. with magnetic strip. company...)
ref.23361
ref.2336
ref.2336
For replacement with magnetic strip.
ref.2364
Proximity keyring.
ref.44501
Specifications Dimensions (WxHxDmm): 153x123x50 Flush box (included): 130x160x55 Superface box (WxHxDmm):154x184x73 Environmental protection (IP): 53 Protection against knocks (IK): 09 Power supply (V): 12V (ac/dc)
24
Cons. (mA) without door release: 80/120 Relay contact: 2A (NA,NC). Operating temperature: 0 to 60ºC Reading distance (card/keyring): 6/5 cm PC Interface: RS-232
STAND-ALONE
Radiofrequency stand-alone
Trinary RF emitter (ref.79561) Radiofrequency emitter 433.92MHz. Trinary technology. New and highly robust design. Dual channel emitter that can activate two relays. Configuration of the sequence of digits required by means of microswitches. Simple and easy to use.
Technical features
Dip switch configuration (8 microswitches in 3 positions). Unlimited number of users admitted by the receiver. Includes battery 12Vdc. Range: 30m. Frequency: 433.92 MHz. Consumption in transmission: 10mA Consumption in standby: 0.1mA
Installation
2 Door release
RF Emitter Ref.79561
Compatible with
Receiver
ref.7952 Single channel receiver for garages.
ref.7900 Single channel receiver PCB (OEM).
ref.7903 Single channel receiver DIN rail.
Specifications
Available in kit (ref.7910 y ref.7911)
Dimensions (WxHxDmm): 53x36x13mm
25
STAND-ALONE
Radiofrequency stand-alone
Receiver for garages (ref.7952) Single channel receiver 433.92MHz. Trinary technology. When the code emitted by the trinary emitter (ref.79561) is received, the receiver closes a circuit that triggers the electric lock or door automation. Mounted in watertight box (IP65) in ABS. Programming by 8 microswitches in 3 positions.
Technical features
Includes rigid antenna 25 cm. Optionally, by adding card ref.7934, the receiver can be turned into dual channel to trigger a second relay. Reception frequency: 433.92 MHz. Sensitivity: 3 mV Relay contact: 2 A max. Power supply: 220Vac/50Hz Consumption: 110 mA in standby.
Installation
Ref.7934
Ref.7952 2
RF emitter Ref.79561
Alarm
2 Door release
Compatible with
Specifications
26
Trinary emitter (ref.79561)
Dimensions (WxHxDmm): 90x165x55mm
Available in kit (ref.7911)
STAND-ALONE
Radiofrequency stand-alone
Single Channel Receiver (ref.7900) Single channel receiver 433.92MHz. Trinary technology. The receiver admits all emitters (ref.79561) programmed with the same code. Can be installed in any FERMAX audio or video door entry panel.
Technical features
Trinary dip switch configuration (8 microswitches in 3 positions). Power supply: 12 Vdc/12 Vac. Frequency: 433.92 MHz. Output 12Vac to activate an electric lock. Output for pushbutton connection to open the door from inside.
230Vac Power supply
Installation
2
2
Ref.7900 (To be installed inside the flush box).
Door release 2
Exit button
RF emitter (ref.79561)
Compatible with
Specifications
Trinary emitter (ref.79561)
Dimensions (WxHxDmm): 20x70x60mm
27
STAND-ALONE
Radiofrequency stand-alone
DIN rail receiver (ref.7903) Single channel receiver 433.92MHz. Trinary technology. The receiver admits all emitters (ref.79561) programmed with the same code. Includes, in DIN6 format, the RF receiver and transformer or power supply. Ideal for shops, offices and businesses.
Technical features
Direct connection to 220Vac/50Hz. DIN rail or wall mounted. Output for pushbutton connection to open door from inside. Frequency: 433.92 MHz. Trinary dip switch configuration (8 microswitches in 3 positions). Output 12Vac for an electric lock activation. Dimensions: 6-element DIN.
Installation
Electric cabinet
REF.7903
RF emitter Ref. 79561
Compatible with
Specifications
28
Trinary emitters (ref.79561)
Dimensions (WxHxDmm): 105x90x60mm
Available in kit (ref.7910)
Ref. 7903
STAND-ALONE
Radiofrequency stand-alone
RF digital emitter (ref.24651) Radiofrequency emitter 433.92MHz. Digital Technology. New and highly robust design. Dual channel emitter that can activate two relays. Secure code, unique, non configurable and exclusive as standard per emitter. It is necessary to authorize/cancel emitters in the receivers.
Technical features
Unique and exclusive code per emitter. Includes battery 12Vdc. Range: 30m. Frequency: 433.92 MHz. Consumption in transmission: 10 mA. Consumption in standby: 0.1mA
REF. 24561
RECEPTOR SEGURIDAD SECURITY RECEIVER
Installation
Door release
RF emitter Ref. 24651
Compatible with
2
RF receiver Ref.7960
Ref.7960 Villa receiver (stand-alone).
Ref.1065 MDS receiver (centralized).
Ref.2464 MDS Secondary receiver (centralized).
Specifications
Available in kit (ref.7912)
Dimensions (WxHxDmm): 53x36x13mm
29
STAND-ALONE
Radiofrequency stand-alone
Villa Receiver (ref.7960) Radiofrequency receiver 433.92MHz. Digital technology. Only authorized digital (ref.24651) or dual (ref.25511) emitters will trigger the device. Reduced size enables installation in electrical cabinets (embeddable in standard boxes 10x10cm). Emitters must be authorized in the receiver.
Technical features
Power supply 12Vac/12Vdc. Lets you store up to 10 emitters (users) in memory with unique and different codes. Electric lock activation by relay. Programmable timing. Exit pushbutton input. Frequency: 433.92 MHz. Door open time programming by dip-switch.
REF. 7960
RECEPTOR SEGURIDAD SECURITY RECEIVER
Installation
Door release
RF emitter Ref. 24651
Compatible with
Specifications
30
2
Receiver Ref.7960
Digital (ref.24651) or dual (ref.25511) emitters.
Dimensions (WxHxDmm): 62x70x20mm
Available in kit (ref.7912)
STAND-ALONE
Radiofrequency stand-alone
Dual RF emitter (ref.25511) Radiofrequency emitter 433.92MHz. Dual technology. New and highly robust design. Dual channel emitter can activate two relays. Secure code, unique, non configurable and exclusive as standard per emitter. It is necessary to authorize/cancel emitters in the receivers. Internally integrates proximity card electronics so can be used as a dual channel emitter and as substitute identifier for proximity cards or keyrings.
Technical features
In addition to the RF functions, incorporates proximity card electronics for use in any proximity reader. Includes battery 12Vdc. Range: 30m. Proximity reader distance: 2 cm. Frequency: 433.92 MHz. Consumption in transmission: 10mA. Consumption in standby: 0.1mA
2
Installation
Door release RF emitter Ref.25511
Compatible with
Receiver for garages
Ref.7960 Villa receiver (stand-alone).
Ref.1065 MDS receiver (centralized).
Ref.2464 MDS secundary receiver (centralized).
Specifications
Dimensions (WxHxDmm): 53x36x13mm
31
STAND-ALONE
Bluetooth stand-alone
City Bluetooth (ref.4477)
Bluetooth
Access control reader by Bluetooth technology where the mobile telephone acts as user identifier. Manufactured in aluminium. Flush or surface mounted (ref.8851). Recommended for interiors and exteriors. Reader and controller in the same module.
TM
Technical features
Electric lock activation by relay. Programmable relay time (monostable, bistable). Several operating modes: authorized personnel only (capacity 40 users) or without user limits. In “authorized personnel only” mode the door can be opened totally hands free, with key confirmation or PIN code. In “no user limit” mode the door is always opened by a PIN. Configurable reader range: up to 2m, 9m or 20m.
Programmation
Programming can be done in three ways: through a master mobile (recognized by the reader when powered up the first time) with simple and intuitive commands, by PC with Bluetooth connection (software downloadable from www.fermax.com) or by PDA with Bluetooth.
Installation
The reader is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock.
230Vac
Power supply 2 Door release 2 Ref.4477 Bluetooth
TM
2
Exit button
Specifications
32
Dimensions (WxHxDmm): 130x128x18 Flush box (included): 115x114x45 Surface box (WxHxDmm): 130x128x33 Enviromental protection (IP): 43 Protection against knocks (IK): 07
Power supply (V): 12V (ac/dc) Cons. (mA) without door release: 80/200 Relay contact: 2A (NA,NC) Programmable from 01 to 99 sec. or bistable Operating temperatue: 0 to 70ºC
Available in kit (ref.4478)
STAND-ALONE
Bluetooth stand-alone
CityMax Bluetooth (ref.4476)
Bluetooth
Access control reader by Bluetooth technology where the mobile telephone acts as user identifier. To be fitted in the viewer of CityMax audio or video door entry panels for enhanced security in the home. Reader and controller in the same module.
TM
Technical features
Electric lock activation by relay. Programmable relay time (monostable, bistable). Several operating modes: authorized personnel only (capacity 40 users) or without user limits. In “authorized personnel only” mode the door can be opened totally hands free, with key confirmation or PIN code. In “no user limit” mode the door is always opened by a PIN. Configurable reader range: up to 2m, 9m or 20m.
Programmation
Programming can be done in three ways: through a master mobile (recognized by the reader when powered up the first time) with simple and intuitive commands, by PC with Bluetooth connection (software downloadable from www.fermax.com) or by PDA with Bluetooth.
Installation
The audio or video door entry panel is located in the outside area. It is possible to set up the panel intuitively to include a reader (ref.4476) for greater security and more convenient access.
2 230Vac
Power supply 2 Door release 2 Ref.4476 Bluetooth
TM
2
Exit button
Specifications
Enviromental protection (IP): 43 Protection against knocks (IK): 07 Power supply (V): 12V (ac/dc) Consumption (mA) without door release: 6/60 Relay contact: 2A (NA,NC) Programmable from 01 to 99 sec. or bistable Operating temperature: 0 to 70ºC
33
STAND-ALONE
Fingerprint stand-alone
City fingerprint (ref.6990) Fingerprint reader with thermal sensor and storage capacity for 950 prints. Manufactured in aluminium in new City styling. Flush or surface mounted. Recommended for interiors and exteriors. Reader and controller integrated in the same module.
Technical features
Exit pushbutton and free access button input. Number of users: - 950 in 1 fingerprint per person mode. - 630 in 2 fingerprints per person mode. 2 status signal LEDs: door open/closed. Display 7-3-digit segments. Infrared receiver for programming. Electric lock activation by relay and one auxiliary relay. Programmable relay times (monostable, bistable).
Programmation
The system is programmed with one fingerprint (the administrator’s) and with a remote infrared keypad for user authorizations/cancellations.
Installation
The reader is located in the outside zone. The rest of the devices, installed indoors, are connected to it: power supply and electric lock. Optionally, an exit pushbutton can be used if there is no door handle (LOFT model) to detect if the door remains open.
2 230Vac
Power supply 2 Door release 2 Ref.6990 2
Exit button
Specifications
34
Dimensions (WxHxDmm): 130x128x18 Flush box (included): 115x114x45 Superface box (WxHxDmm):130x128x33 Environmental protection (IP): 43 Protection against knocks (IK): 07
Power supply (V): 12V (ac/dc) Consumtion (mA) without door release: 6/60 Relay contact: 2A (NA,NC) Operating temperature: 0 to 60ºC
Available in kit (ref.6988)
STAND-ALONE
Fingerprint stand-alone
City fingerprint module (ref.6989) Fingerprint reader with thermal sensor and storage capacity for 950 prints. To be fitted in the viewer of CityMax audio or video door entry panels for enhanced security in the home. Reader and controller integrated in the same module.
Technical features
Exit pushbutton and free access button input. Number of users: - 950 in 1 fingerprint per person mode. - 630 in 2 fingerprint per person mode. 2 status signal LEDs: door open/closed. Display 7 3-digit segments. Infrared receiver for programming. Electric lock activation by relay and one auxiliary relay. Programmable relay times (monostable, bistable).
Programmation
The system is programmed with one fingerprint (the administrator) and with a remote infrared keypad for user authorizations/cancellations.
Installation
The audio or video door entry panel is located in the outside area. It is possible to set up the panel intuitively to include a reader (ref. 6989) for greater security and more convenient access.
230Vac Power supply 2
2
Door release Ref.6989 2
Exit button
Specifications
Environmental protection (IP): 43 Protection against knocks (IK): 07 Power supply (V): 12V (ac/dc)
Consumption (mA) without door release: 6/60 Relay contact: 2A (NA,NC) Operating temperature: 0 to 60ºC
35
Access control systems consisting of several accesses (up to a maximum of 32) and PC managed.
Stand-alone
access
control
in
network
Controller stand-alone in network
Door Controller (ref.44201)
STAND-ALONE IN NETWORK
Door controller with 500 event memory (ref.44201). Includes CD with management software. The door controller manages the devices in each access: up to two readers (if they are used as entrance and exit), electric lock, door sensor and exit button. Up to 32 door controllers can be connected in series to manage 32 entry and exit accesses. Thanks to the internal memory, it enables user authorizations/cancellations and access permits/restrictions from a PC. On-line incidents record. Capacity: 1.000 users. Indoor installation and separate from the reader for greater security. Admits Wiegand-26 input or magstrip.
Technical features
Each door controller manages 1.000 users. The connection between controllers consists of 2 power wires and a twisted pair for data. Admits an exit and entrance reader, electric lock relay, auxiliary relay for other functions, pushbutton connection, door sensor and free access button. Necessary for vehicle accesses for connection of entrance or exit detection coils. Status LEDs: transmission and reception. Lets you connect any reader with Wiegand-26 output or Magstrip (Aba TrackII or Dataclock). Admits Dallas i-button key readers and matrix keypads in 8-bit burst format. One power supply (ref.4813) recommended every 6 readers.
Programmation
Programmed from a PC with the corresponding software (included in ref.44201).
Installation
Installation in mechanism box 100x100mm or surface mounted with 2 screws (included).
2 wires Readers
Up to 32 Readers
2 wires
power supply
twisted pair 2 wires ( restricted area )
PRIVATE ACCESS CONTROL
twisted pair 2 wires
PC connection accessory (needed) ref.24661
2 wires
( restricted area )
PRIVATE ACCESS CONTROL
twisted pair
twisted pair
2 wires twisted pair 2 wires
PC Door controllers (ref.44201)
twisted pair
Specifications 38
Dimensions (WxHxDmm): Power supply (V):
85x88x25 Consumption (mA): 12Vdc Operating temperature:
15/100 0 to 60ºC
Memokey&Private WG stand-alone in network
City Memokey&Private WG combination (ref.4480)
Technical features
Programmation
Installation 2 wires Readers 2 wires
Power supply
( restricted area )
PRIVATE ACCESS CONTROL
Up to 32 Readers
1
2
3
4
5
6
7
8
9
A
0
B
twisted pair 2 wires
STAND-ALONE IN NETWORK
Access control reader with dual technology: proximity and keypad with capacity for up to 1.000 users. Stand-alone or joint operation for greater security: PIN code + card. Manufactured in aluminium in City styling. Flush or surface mounted. Recommended for interiors and exteriors. Door controller (ref.44201) required for operation.
Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers equip the installation with access control with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by the door controller with memory (ref.44201). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: door open/closed/power supply.
Programming and start-up from PC software (included in ref.44201).
The reader is located outdoors and connected to the controller located in the interior. Optionally, an exit pushbutton can be used (if there is no door handle). Can be combined with any Wiegand-26 bit or Dataclock output reader.
( restricted area )
PRIVATE ACCESS CONTROL
twisted pair
PC connection accessory (needed) ref.24661
2 wires
2 wires
twisted pair
twisted pair
( restricted area )
PRIVATE ACCESS CONTROL
2 wires twisted pair 2 wires
PC Door controllers (ref.44201)
Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)
For replacement with magnetic strip.
Proximity keyring
ref.2364
ref.44501
twisted pair
Identifiers
Specifications
ref.23361
ref.2336
ref.2336
Dimensions (WxHxDmm): 130x175x18 Flush box (included): 115x162x45 Surface box (WxHxDmm): 130x175x33 Environmental protection (IP): 43
Protection against knocks (IK): 07 Power supply (V): 12Vdc Cons. (mA) without door release: 30mA Operating temperature: 0 to 60ºC
39
Memokey&Private WG stand-alone in network
Loft Memokey&Private WG (ref.4550)
STAND-ALONE IN NETWORK
Access control reader with dual technology: proximity and keypad with capacity for up to 1.000 users. Stand-alone or joint operation for greater security: PIN code + card. Manufactured in ABS plastic. Surface mounted. Recommended for interiors. Ideal for screen profiles in offices. Includes a 50cm cable. Door controller (ref.44201) required for operation.
Technical features
Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers equip the installation with access control with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by the door controller with memory (ref.44201). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: door open/closed/power supply.
Programmation
Programming and start-up from PC software (included in ref.44201).
Installation
The reader is located outdoors and connected to the controller located in the interior. Optionally, an exit pushbutton can be used (if there is no door handle). Can be combined with any Wiegand-26 bit or Dataclock output reader.
2 wires Readers 2 wires 1
2
Power supply
3
4
5
6
7
8
9
A
0
B
twisted pair 2 wires
Up to 32 Readers
( restricted area )
PRIVATE ACCESS CONTROL
PC connection accessory (needed) ref.24661
twisted pair 2 wires
2 wires
twisted pair
twisted pair
( restricted area )
PRIVATE ACCESS CONTROL
2 wires twisted pair 2 wires
PC
Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)
For replacement with magnetic strip.
Proximity keyring
Door controllers (ref.44201)
twisted pair
Identifiers Specifications
40
ref.23361
ref.2336
ref.2336
Dimensions (WxHxDmm): 60x130x23 Flush box (Not required): Surface box (Not required): 66 Environmental protection (IP):
ref.2364
ref.44501
Protection against knocks (IK): 06 12Vdc Power supply (V): Cons. (mA) without door release: 40mA 0 to 60ºC Operating temperature:
Private WG stand-alone in network
City Private WG (ref.4490)
Technical features
Programmation
Installation 2 wires Readers 2 wires
STAND-ALONE IN NETWORK
Proximity card reader with capacity for up to 1.000 users. Manufactured in aluminium. Flush or surface mounted (ref.8851). Recommended for interiors and exteriors. Door controller (ref.44201) required for operation.
Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers equip the installation with access control with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by the door controller with memory (ref.44201). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: door open/closed/power supply.
Programming and start-up from PC software (included in ref.44201).
The reader is located outdoors and connected to the controller located in the interior. Can be combined with any Wiegand26 bit or Dataclock output reader.
Power supply
( restricted area )
PRIVATE ACCESS CONTROL
Up to 32 Readers
twisted pair 2 wires 1
2
3
4
5
6
7
8
9
A
0
B
PC connection accessory (needed) ref.24661
twisted pair 2 wires
2 wires
twisted pair
twisted pair
( restricted area )
PRIVATE ACCESS CONTROL
2 wires twisted pair 2 wires
PC
Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)
For replacement with magnetic strip.
Proximity keyring
ref.2364
ref.44501
Door controllers (ref.44201)
twisted pair
Identifiers Specifications
ref.23361
ref.2336
ref.2336
Dimensions (WxHxDmm): 130x128x18 Flush box (included): 115x114x45 Surface box (WxHxDmm): 130x128x33 Environmental protection (IP): 43 Protection against knocks (IK): 07 Power supply (V): 12Vdc
Cons. (mA) without door release: 30mA Operating temperature: 0 to 60ºC Reading distance (card/keyring): 6/5 cm PC Interface: RS-485/USB
41
Private WG stand-alone in network
Bruto Private WG (ref.4510)
STAND-ALONE IN NETWORK
Proximity card reader with capacity for up to 1.000 users. Vandal-proof panel. Flush or surface mounted (ref.2778). Recommended for interiors and exteriors. Door controller (ref.44201) required for operation.
Technical features
Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers equip the installation with access control with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by the door controller with memory (ref.44201). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: door open/closed/power supply.
Programmation
Programming and start-up from PC software (included in ref.44201).
Installation
The reader is located outdoors and connected to the controller located in the interior. Optionally, an exit pushbutton can be used (if there is no door handle). Can be combined with any Wiegand-26 bit or Dataclock output reader.
2 wires Readers 2 wires
Power supply
( restricted area )
PRIVATE ACCESS CONTROL
twisted pair 2 wires
Up to 32 Readers
1
2
3
4
5
6
7
8
9
A
0
B
PC connection accessory (needed) ref.24661
twisted pair 2 wires
2 wires
twisted pair
twisted pair
( restricted area )
PRIVATE ACCESS CONTROL
2 wires twisted pair
PC
2 wires
Door controllers (ref.44201)
Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)
For replacement with magnetic strip.
Proximity keyring
twisted pair
Identifiers Specifications
42
ref.23361
ref.2336
ref.2336
Dimensions (WxHxDmm): 135x130x18 Flush box (included): 115x100x45 Surface box (WxHxPmm): 135x131x42 Environmental protection (IP): 53 Protection against knocks (IK): 09 Power supply (V): 12Vdc
ref.2364
ref.44501
Cons. (mA) without door release: 30 Operating temperature: 0 to 60ºC Reading distance (card/keyring): 4/2 cm PC Interface: RS-485/USB
Private WG stand-alone in network
Loft Private WG (ref.4560)
Technical features
Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers equip the installation with access control with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by the door controller with memory (ref.44201). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: door open/closed/power supply.
Programmation
Programming and start-up from PC software (included in ref.44201).
Installation
The reader is located outdoors and connected to the controller located in the interior. Optionally, an exit pushbutton can be used (if there is no door handle). Can be combined with any Wiegand-26 bit or Dataclock output reader.
2 wires Readers 2 wires
Power supply
twisted pair 2 wires
STAND-ALONE IN NETWORK
Proximity card reader with capacity for up to 1.000 users. Manufactured in ABS plastic. Surface mounted. Recommended for interiors. Ideal for screen profiles in offices. Includes a 50cm cable. Door controller (ref.44201) required for operation.
Up to 32 Readers
( restricted area )
PRIVATE ACCESS CONTROL
twisted pair 2 wires
2 wires
twisted pair
twisted pair
PC connection accessory (needed) ref.24661
( restricted area )
PRIVATE ACCESS CONTROL
Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)
2 wires twisted pair 2 wires
For replacement with magnetic strip.
Proximity keyring
PC Door controller (ref.44201)
twisted pair
Identifiers Specifications
ref.23361
ref.2336
Dimensions (WxHxDmm): 60x130x23 Flush box (included): Not required Surface box (WxHxDmm): Not required Environmental protection (IP): 66 Protection against knocks (IK): 06 Power supply (V): 12V (ac/dc)
ref.2336
ref.2364
ref.44501
Cons. (mA) without door release: 40 Operating temperature: 0 to 60ºC Reading distance (card/keyring): 6/5 cm PC Interface: RS-485/USB
43
Fingerprint WG stand-alone in network
City fingerprint WG (ref.6990) WG fingerprint (ref.6990)
STAND-ALONE IN NETWORK
Fingerprint reader with thermal sensor and storage capacity for 1.000 prints. Manufactured in aluminium in new City styling. Flush or surface mounted. Recommended for interiors and exteriors. Door controller (ref.44201) required for operation.
Technical features
Door controller (ref.44201) required for operation. Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers equip the installation with access control with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by door controller with memory (ref.44201). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: door open/closed/power supply. Display 7 3-digit segments. Infrared receiver for programming. Number of users: - 950 in 1 person mode. - 630 in 2 fingerprint mode.
Programmation
The system is programmed with one fingerprint (the administrator’s) and with a remote infrared keypad for user authorizations/cancellations. User authorizations and cancellations can be done from a PC with the software included in the door controller (ref.44201).
Installation
The reader is located outdoors and connected to the controller located in the interior. Can be combined with any Wiegand-26 bit or Dataclock output reader.
2 wires 2 wires
Power supply
twisted pair 2 wires
PC connection accessory (needed) ref.24661
Up to 32 Readers
( restricted area )
PRIVATE ACCESS CONTROL
twisted pair
PC connection accessory (needed) ref.24661
2 wires
2 wires
twisted pair
twisted pair
( restricted area )
PRIVATE ACCESS CONTROL
2 wires twisted pair 2 wires
PC Door controller (ref.44201)
twisted pair
Readers
Specifications
Dimensions (WxHxDmm): 130x128x18 Flush box (included): 115x114x45 Surface box (WxHxDmm): 130x128x33 Environmental protection (IP): 43
Protection against knocks (IK): 07 Power supply (V): 12Vdc Consumption (mA) without door release: 30 Operating temperature: 0 to 60ºC
44
Fingerprint WG stand-alone in network
City WG Module Fingerprint (ref.6989)
Technical features
Programmation
The system is programmed with one fingerprint (the administrator’s) and with a remote infrared keypad for user authorizations/cancellations. User authorizations and cancellations can be done from a PC with the software included in the door controller (ref.44201).
Installation
The reader is located outdoors and connected to the controller located in the interior. Optionally, an exit pushbutton can be used (if there is no door handle). Can be combined with any Wiegand-26 bit or Dataclock output reader.
2 wires 2 wires
Power supply
twisted pair 2 wires ( restricted area )
Up to 32 Readers
Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers equip the installation with access control with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by the door controller with memory (ref.44201). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: door open/closed/power supply. Display 7 3-digit segments. Infrared receiver for programming. Number of users: - 950 in 1 person mode. - 630 in 2 fingerprint mode.
PRIVATE ACCESS CONTROL
twisted pair 2 wires
2 wires
twisted pair
twisted pair
PC connection accessory (needed) ref.24661
PC conection accessory (needed) ref.24661
( restricted area )
PRIVATE ACCESS CONTROL
2 wires twisted pair 2 wires
PC Door controllers (ref.44201)
twisted pair
Readers
Specifications 45
Environmental protection (IP): 43 Protection against knocks (IK): 07 Power supply (V): 12Vdc
Consumption (mA) without door release: 30 Operating temperature: 0 to 60ºC
STAND-ALONE IN NETWORK
Fingerprint reader with thermal sensor and storage capacity for 1.000 prints. To be fitted in the spare space of CityMax audio or video door entry panels for enhanced security in the home. Door controller (ref.44201) required for operation.
Systems that let you approach complex installations with advanced functions and a multitude of accesses.
Centralized Access Control
CAC Central Unit centralized
CAC Central Unit (ref.4410) Central Unit that lets you approach complex access control installations handling up to 32 accesses or doors with a total of 2048 users. A maximum of 64 central units can be connected (2048 accesses). Includes four management softwares: CAC Data Base Server, CAC Server, CAC Access and CAC Time & Attendance. The Central Unit also monitors up to 1.000 sensors and 1.000 relays for automatic functions. Local (USB, RS-232) or remote (IP) connection to PC via the corresponding module (see accessories section).
CENTRALIZED
Technical features
Each Central Unit manages: 2.048 users. 32 accesses. 3.000 incidents (entries, exits, access denied, alerts, etc) in memory, with no need to download to PC. Managing up to 1.000 intercom panels, 1.000 sensors and 1.000 relays. The readers connectable to the Central Unit are with builtin or external controller (ref.4420).
Programmation
All programming is done with CAC software from one or several duly authorized on line or remote computers.
Power supply 12 Vdc
Installation Up to 64 Central Units 2 wires
2 wires
2 wires
twisted pair
twisted pair Central Unit (ref.4410)
twisted pair
Central Unit (ref.4410) ( restricted area )
PRIVATE ACCESS CONTROL
1
2
3
4
5
6
7
8
9
A
0
B
........
1
2
4
5
3
8
9
0
B
Up to 32 readers 2 wires
1
2
3
4
5
6
7
8
9
A
0
B
6
7 A
........
1
2
3
4
5
6
7
8
9
A
0
B
Up to 32 readers
2 wires ( restricted area )
1
2
3
4
5
6
7
8
9
A
0
B
1
2
3
A
4
5
6
0
7
8
9
B
PRIVATE ACCESS CONTROL
1
twisted pair Reader
twisted pair Reader
2
3
4
5
6
7
8
9
A
0
B
Reader
Up to 32 readers
Specifications 48
150 Dimensions (WxHxDmm): 175x90x40 Cons. (mA) without door release: Operating temperature: 0 to 60ºC Fixation: DIN rail or 2 screws to wall Power supply (V): 12Vdc
Software CAC Access centralized
CAC Access Needs CAC Data Base Server software installed (manages the SQL database) and CAC Server. Both included in the central unit. Software included in the Central Unit (ref.4410) to manage readers, user groups and advanced access control functions. Friendly graphic interface, simple and intuitive with © a framework similar to Outlook . All the options can be viewed in a hierarchic tree: doors, user profiles, schedules, automation. TCP/IP client server architecture.
Technical features
CENTRALIZED
2.048 users. 64 user groups (profiles). Each one defines the restrictions that are applied to the group by allocation of up to 3 areas and 3 schedules. 4 special profiles without user restrictions. Special treatment for vehicles (parking areas). 32 areas. They define the doors to which access is allowed. 32 schedules. They define the periods of time when access is allowed to users. On-line record of the last 3000 incidents (entries, exits, access denied, alerts, etc). 32 weekly device activation schedules (sensors/relays). Capacity limitation in certain rooms or premises to a number of people. Door blocking/unblocking. Temporary user blocking individually or by groups. Access not permitted until they are unblocked. Option to assign timed and physical expiry of proximity cards (typical application in hotels). Automatic change of winter/summer time. Anti-pass back function, which prevents two people using the same identifier to access the facility. The doors that belong to the installation perimeter are defined and are checked to see if the user is inside or outside the perimeter when coming through them. There are two anti-passback levels associated with the same identifier, depending on how the facility is accessed, by pedestrian door or for vehicles (the type of door is defined by the «CAC Control Server» application). All the users may be located outside the perimeter at a set programmed time. Continuous testing of devices. Firmware update in installation. Lets you update the central unit with new versions or functions and resolve problems. Activation of devices associated to each user, presenting the identifier in a reader. Relay activation from a reader with keyboard and proximity. Alarms connection and disconnection.
49
Software CAC Time & Attendance centralized
CAC Time & Attendance Needs CAC Data Base Server software installed (manages the SQL database) and CAC Server. Both included in the central unit. Software included in Central Unit (ref.4410) for managing entry/exit of people, clock-ins and calculating hours worked for wages processing. Friendly graphic interface, simple and intuitive with © a framework similar to Outlook . All the options can be viewed in a hierarchic tree: doors, user profiles, schedules, automation.
Technical features
CENTRALIZED
2048 users. 64 user groups (profiles). Each one defines the restrictions that are applied to the group by allocation of up to 3 areas and 3 schedules. 4 special profiles without user restrictions. 32 schedules. They define the periods of time when access is allowed to users. Vacations (20 holidays and 3 vacation periods). Record of the last 3.000 incidents (entries, exits, etc). People location control for emergency evacuations. Allocation of events in the exit readers by PIN code (doctor, commercial visit, etc). Generation of daily, weekly or monthly information: actual hours, delays, overtime, etc. Door blocking/unblocking. Temporary user blocking individually or by groups. Access not permitted until they are unblocked. Automatic change of winter/summer time. Manual change of anomalies in employee presence. Continuous testing of devices. Firmware update in installation. Lets you update the central unit with new versions or functions and resolve problems. Activation of devices associated to each user, presenting the identifier in a reader. Relay activation from a reader with keyboard and proximity. Alarms connection and disconnection.
50
Central Unit MDS centralized
Central Unit MDS (ref.2405)
Technical features
Each Central Unit manages: 1.022 users. 31 accesses (audio, video door entry or access control readers). 3.000 incidents (entries, exits, access denied, alerts, etc.) in memory, with no need to download to PC. Managing up to 1.000 intercom panels, 1.000 sensors and 1.000 relays. Capacity of 10 guard units. The readers connectable to the Central Unit are with builtin or external controller (ref.4420).
Programmation
All programming is done with Wincom+ software from one or several duly authorized on-line or remote computers.
Power supply 12Vdc
CENTRALIZED
Central Unit that lets you approach complex MDS audio and video door entry systems combined with access control functions. Each Central Unit is able to manage up to 10.000 houses, 1.022 users and 31 audio or video door entry or access control panels. Can connect up to a maximum of 63 central units (approx. 2.000 accesses). Wincom+ management software included. The Central Unit also monitors up to 1.000 sensors and 1.000 relays for automatic functions. Local (USB, RS-232) or remote (IP) connection to PC via the corresponding module (see accessories section).
Installation Up to 64 Central Units
2 wires
2 wires
twisted pair
twisted pair
twisted pair
Central Unit (ref.2405)
2 wires
................
2
3
5
6
7
8
9
A
0
B
2 wires
twisted pair Reader
PRIVATE ACCESS CONTROL
Up to 32 elements 2 wires
1 4
( restricted area )
twisted pair Video panel Up to 32 elements
Audio panel
51
Wincom+ Software centralized
Wincom+ Software Software included in Central Unit (ref.2405) to manage complex audio, video door entry and access control installations. Management of all the parameters from a unique software with framework similar to Outlook©. All the options can be viewed in a hierarchic tree: doors, user profiles, schedules, automation.
Technical features
CENTRALIZED
1022 users 64 user groups (profiles). Each one defines the restrictions that are applied to the group by allocation of up to 3 areas and 3 schedules. 32 areas. They define the doors to which access is allowed. 32 schedules. They define the periods of time when access is allowed to users. On-line record of the last 3.000 incidents (entries, exits, access denied, alerts, etc), all exportable to Excel. Vacations (20 holidays and 3 vacation periods). Installation configuration and testing. 2 user levels (administrator, operator). Lift control. Perimeter anti-passback function. Capacity limitation in certain rooms or premises to a number of people. Door blocking/unblocking. Activation of devices associated to each user, presenting the identifier in a reader. Relay activation from a reader with keyboard and proximity. Alarms connection and disconnection.
52
Controller centralized
Door Controller (ref.4420)
Technical features
Connection between controllers consists of 2 power cables and one twisted pair for data. Admits an exit and entry reader, electric lock relay, auxiliary relay for other functions, connection button, door sensor and free access. Dip switch to encode the door number, reader type and access type (pedestrian or vehicle). Necessary in vehicle accesses for connection of entrance or exit detection coils. Lets you connect any reader with Wiegand-26 input, Magstrip (Aba Track II or Dataclock). Lets you connect button key type readers Dallas i-button and matrix keypads in 8-bit burst format. Test button to check the correct installation of all devices connected to the controller.
Installation
Installation in mechanism box 100x100mm or surface mounted with 2 screws (included).
CENTRALIZED
Door controller without memory (ref.4420). Manages the devices present in each access: up to two readers (if they are entry and exit), electric lock, door sensor and exit button. Installation indoors and separated from reader for higher security. Input Wiegand-26, magstrip or ibutton.
Power supply 12Vdc
Up to 64 Central Units 2 wires
2 wires
Door controller ref.4420
twisted pair
Door controller ref.4420
Door controller ref.4420
Door controller ref.4420
7 wires
twisted pair
twisted Central Unit pair (ref.4410 o ref.2405)
7 wires
2 wires
Reader
Reader
7 wires
7 wires
7 wires
Door controller ref.4420
( restricted area )
( restricted area )
1
2
3
4
5
6
7
8
9
A
0
B
PRIVATE ACCESS CONTROL
Reader
PRIVATE ACCESS CONTROL
Reader
Reader Up to 32 readers
Specifications
Dimensions (WxHxDmm): 85x88x25 Power supply (V): 12Vdc
Consumption: 15mA / 100mA Operating temperature: 0 to 60ºC
53
Memokey centralized
City Memokey MDS (ref.23291) Access control keypad with capacity up to 100 different 4- to 6-digit codes. Manufactured in aluminium. Flush or surface mounted (ref.8851). Recommended for interiors and exteriors. Reader and controller in the same module. No door controller required (ref.4420).
Exit pushbutton input, door sensor input and electric lock relay. 2-wire cables for power supply and twisted pair for data. Dip switch to encode door number and electric lock activation timing. Requires external relay (ref.2013) if activating electric lock with consumption over 500mA, inverted function or external device (motor, barrier).
Programmation
Programming from PC software corresponding to installed Central Unit (ref.2405 or ref. 4410).
Power supply 12 Vdc
Up to 64 Central Units 2 wires
Central Unit (ref.2405 or 4410)
2 wires
2 wires
twisted pair
twisted pair
1
twisted pair
CENTRALIZED
Technical features
2
1
3
4
5
6
7
8
9
A
0
B
........
2
Central Unit (ref.4410)
3
4
5
7
8
9
A
0
B
1
6
Up to 32 readers 2 wires 1
2
3
4
5
6
7
8
9
A
0
B
Reader
twisted pair
2
1
3
4
5
6
7
8
9
A
0
B
........
2
3
4
5
6
7
8
9
A
0
B
Up to 32 readers
2 wires 1
2
3
A
4
5
6
0
7
8
9
B
Reader
1
twisted pair
2
3
4
5
6
7
8
9
A
0
B
Reader
Up to 32 readers
Specifications
54
Dimensions (WxHxDmm): 130x128x18 Flush box (included): 115x114x45 Surface box (WxHxDmm): 130x128x33 Environmental protection (IP): 43
Protection against knocks (IK): 07 Power supply (V): 12Vdc Cons. (mA) without door release: 20 Operating temperature: 0 to 60ºC
Memokey centralized
Bruto Memokey MDS (ref.2553)
Technical features
Exit pushbutton input, door sensor input and electric lock relay. 2-wire cable for power supply and twisted pair for data. Dip switch to encode door number and electric lock activation timing. Requires external relay (ref.2013) if activating electric lock with consumption over 500mA, inverted function or external device (motor, barrier).
Programmation
Programming from PC software corresponding to installed Central Unit (ref.2405 or ref.4410).
CENTRALIZED
Access control keypad with capacity up to 100 different 4- to 6-digit codes. Vandal-proof panel. Flush or surface mounted (ref.2778). Recommended for interiors and exteriors. Reader and controller integrated in the same module. Ideal for troubled zones or districts, offices, banks, etc. No door controller required (ref.4420).
Installation
Power supply 12 Vdc
Up to 64 Central Units 2 wires
2 wires
twisted pair
twisted pair
twisted pair
Central Unit (ref.2405 or 4410)
2 wires
( restricted area )
........
1
2
4
5
Central Unit (ref.4410)
3 6
7
8
9
A
0
B
1
2
3
4
5
6
7
8
9
A
0
B
........
1
2
3
4
5
6
7
8
9
A
0
B
PRIVATE ACCESS CONTROL
Up to 32 readers 2 wires
Up to 32 readers
2 wires
1
2
3
A
1
2
3
4
5
6
0
4
5
6
7
8
9
B
7
8
9
A
0
B
( restricted area )
PRIVATE ACCESS CONTROL
Reader
twisted pair
Reader
twisted pair
Reader
Up to 32 readers
Specifications
Dimensions (WxHxDmm): 135x130x18 Protection against knocks (IK): 09 Flush box (included): 115x100x45 Power supply (V): 12Vdc Surface box (WxHxDmm): 135x131x42 Operating temperature: 0 to 60ºC Environmental protection (IP): 53
55
Memokey&Private WG centralized
City Memokey&Private WG (ref.4480) Dual technology access control reader: proximity and keypad. Stand-alone or joint operation for greater security: PIN code + card. Manufactured in aluminium in City style. Flush or surface mounted. Recommended for interiors and exteriors. Door controller (ref.4420) required for operation.
Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers let you equip the access control installation with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by door controller (ref.4420). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: open door / closed / power supply.
Programmation
Programming from PC software corresponding to installed Central Unit (ref.2405 or ref.4410).
Installation
Power supply 12 Vdc
Up to 64 Central Units 2 wires
2 wires
twisted pair
CENTRALIZED
Technical features
2 wires
twisted Central Unit (ref.2405 or 4410) pair
2 wires
7 wires
2
2
3
5
6
8
9
A
0
B
Reader
twisted pair
2
3
4
5
6
1
2
3
4
5
6
3
4
5
6
7
8
9
A
0
B
7
8
9
7
8
9
A
0
B
A
0
B
........
7 wires
7 wires
Up to 32 readers
1
2
3
4
5
6
Up to 32 readers
7
8
9
A
0
B
2 wires
2 wires 7
1 PRIVATE ACCESS CONTROL
1
7 wires 4
Central Unit (ref.4410)
( restricted area )
Door controller (ref.4420)
1
twisted pair
1
2
3
A
4
5
6
0
7
8
9
B
Reader
twisted pair
1
2
3
4
5
6
7
8
9
A
0
B
Reader
Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)
For replacement with magnetic strip.
Proximity keyring
Up to 32 readers
Identifiers Specifications
56
ref.23361
ref.2336
ref.2336
Dimensions (WxHxDmm): 130x175x18 115x162x45 Flush box (included): Surface box (WxHxDmm): 130x175x33 Metalic box (WxHxDmm): 154x203x50 Environmental protection (IP): 43
ref.2364
ref.44501
Protection against knocks (IK): 07 Power supply (V): 12Vdc Cons. (mA) without door release: 30mA Operating temperature: 0 to 60ºC
Memokey&Private WG centralized
Loft Memokey&Private WG (ref.4550) Dual technology access control reader: proximity and keypad. Stand-alone or joint operation for higher security: PIN code + card. Manufactured in ABS plastic. Surface mounted. Recommended for interiors. Ideal for office screen profiles. Includes a 50cm cable. Door controller (ref.4420) required for operation.
Technical features
Programmation Power supply 12 Vdc
CENTRALIZED
Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers let you equip the access control installation with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by door controller (ref.4420). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: open door / closed / power supply. Programming from PC software corresponding to installed Central Unit (ref.2405 or ref.4410).
Installation
Up to 64 Central Units 2 wires
twisted pair
2 wires
2 wires
twisted Central Unit (ref.2405 or 4410) pair
2 wires
7 wires
twisted pair
Central Unit (ref.4410)
( restricted area )
1
2
3
4
5
6
4
5
6
7
8
9
7
8
9
A
0
B
A
0
B
1
2
3
1
2
3
PRIVATE ACCESS CONTROL
Door controller (ref.4420)
1
2
3
4
5
6
7
8
9
A
0
B
Up to 32 readers
5
6
8
9
A
0
B
Up to 32 readers
2 wires
2 wires 2
4 7
7 wires
7 wires 1
........
3
4
5
6
7
8
9
A
0
B
Reader
twisted pair
1
2
3
A
4
5
6
0
7
8
9
B
Reader
1
twisted pair
2
3
4
5
6
7
8
9
A
0
B
Reader
Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)
For replacement with magnetic strip.
Proximity keyring
ref.2364
ref.44501
Up to 32 readers
Identifiers Specifications
ref.23361
ref.2336
ref.2336
Dimensions (WxHxDmm): 60x130x23 Flush box (not required): Surface box (not required): Environmental protection (IP): 66
Protection against knocks (IK): 06 Power supply (V): 12Vdc Cons. (mA) without door release: 40mA Operating temperature: 0 to 60ºC
57
Private centralized
City Private MDS (ref.23351)
Technical features
Exit pushbutton input, door sensor input and electric lock relay. 2 wire cables for power supply and twisted pair for data to central unit. Dip switch to encode door number and electric lock activation timing. Requires external relay (ref.2013) if activating electric lock with consumption over 500mA, inverted function or external device (motor, barrier).
Programmation
Programming from PC software corresponding to installed Central Unit (ref.2405 or ref.4410).
Power supply 12 Vdc
Installation
Up to 64 Central Units 2 wires
Central Unit (ref.2405 or 4410)
2 wires
2 wires
twisted pair
twisted pair
1
twisted pair
CENTRALIZED
Proximity card reader with capacity up to: - 1.020 users with MDS central unit (ref.2405). - 2.048 users with CAC central unit (ref.4410). Manufactured in aluminium. Flush or surface mounted (ref.8851). Recommended for interiors and exteriors. Reader and controller integrated in the same module. No door controller required (ref.4420).
........
( restricted area )
2
Central Unit (ref.4410)
3
4
5
6
7
8
9
A
0
B
1
2
1
3
4
5
6
7
8
9
A
0
B
........
Up to 32 readers 2 wires
3
5
6
8
9
A
0
B
Up to 32 readers
2 wires 1
2
3
A
4
5
6
0
7
8
9
B
1
( restricted area )
2
3
4
5
6
7
8
9
A
0
B
PRIVATE ACCESS CONTROL
Reader
2
4 7
PRIVATE ACCESS CONTROL
twisted pair
Reader
twisted pair
Reader
Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)
For replacement with magnetic strip.
Proximity keyring
ref.2364
ref.44501
Up to 32 readers
Identifiers Specifications
58
ref.23361
ref.2336
ref.2336
Dimensions (WxHxDmm): 130x128x18 Flush box (included): 115x114x45 Surface box (WxHxDmm): 130x128x33 Environmental protection (IP): 43
Protection against knocks (IK): 07 Power supply (V): 12Vdc Cons. (mA) without door release: 55 Operating temperature: 0 to 60ºC
Private WG centralized
City Private WG (ref.4490) Proximity card reader with capacity up to: - 1.020 users with MDS central unit (ref.2405). - 2.048 users with CAC central unit (ref.4410). Manufactured in aluminium. Flush or surface mounted (ref.8851). Recommended for interiors and exteriors. Door controller (ref.4420) required for operation.
Programmation Power supply 12 Vdc
Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers let you equip the access control installation with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by door controller (ref.4420). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: open door / closed / power supply.
CENTRALIZED
Technical features
Programming from PC software corresponding to installed Central Unit (ref.2405 or ref.4410).
Installation Up to 64 Central Units 2 wires
2 wires
twisted pair
twisted pair
twisted pair
Central Unit (ref.2405 or 4410)
2 wires
Door Controller (ref.4420)
1
2
3
A
4
5
6
0
7
8
9
B
Reader
twisted pair
2 5
7
8
9
A
0
B
3
1
6
2
3
4
5
6
7
8
9
A
0
B
........
1
2
3
4
5
6
7
8
9
A
0
B
Up to 32 readers
2 wires
2 wires PRIVATE ACCESS CONTROL PRIVATE ACCESS CONTROL
1 4
Up to 32 readers
7 wires ( restricted area )
........
Central Unit (ref.4410)
1
2
3
A
4
5
6
0
7
8
9
B
Reader
1
twisted pair
2
3
4
5
6
7
8
9
A
0
B
Reader
Up to 32 readers
Identifiers Specifications
Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)
ref.23361
ref.2336
Dimensions (WxHxDmm): 130x128x18 Flush box (included): 115x114x45 Surface box (WxHxDmm): 130x128x33 Protection environmental (IP): 43 Protection against knocks (IK): 07 Power supply (V): 12Vdc
ref.2336
For replacement with magnetic strip.
ref.2364
Proximity keyring
ref.44501
Cons. (mA) without door release: 30mA Temperature operating: 0 to 60ºC Reading distance (card/keyring): 6/5 cm PC Interface: RS-485/USB
59
Private centralized
Bruto Private MDS (ref.2552)
CENTRALIZED
Proximity card reader with capacity up to: - 1.020 users with MDS central unit (ref.2405). - 2.048 users with CAC central unit (ref.4410). Vandal-proof panel. Flush or surface mounted (ref.2778). Recommended for interiors and exteriors. Reader and controller integrated in the same module. Ideal for troubled zones or districts, offices, banks, etc. No door controller required (ref.4420).
Technical features
Exit pushbutton input, door sensor input and electric lock relay. 2-wire cables for power supply and twisted pair for data. Dip switch to encode door number and electric lock activation timing. Requires external relay (ref.2013) if activating electric lock with consumption over 500mA, inverted function or external device (motor, barrier).
Programmation
Programming from PC software PC corresponding to installed Central Unit (ref. 2405 or ref.4410).
Power supply 12 Vdc
Installation Up to 64 Central Units 2 wires
2 wires
Central Unit (ref.2405 or 4410)
2 wires
twisted pair
twisted pair
twisted pair
1
1
2
3
A
4
5
6
0
7
8
9
B
........
2
Central Unit (ref.4410)
3
4
5
6
7
8
9
A
0
B
Up to 32 readers 2 wires ( restricted area )
PRIVATE ACCESS CONTROL
Reader
twisted pair
1
2
3
4
5
6
7
8
9
A
0
B
1
........
2
3
4
5
6
7
8
9
A
0
B
Up to 32 readers
2 wires 1
2
3
A
4
5
6
0
7
8
9
B
Reader
twisted pair
1
2
3
4
5
6
7
8
9
A
0
B
Reader
Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)
For replacement with magnetic strip.
Proximity keyring
Up to 32 readers
Identifiers Specifications
60
ref.23361
ref.2336
Dimensions (WxHxDmm): 135x130x18 Flush box (included): 115x100x45 Surface box (WxHxDmm): 135x131x42 Environmental protection (IP): 53
ref.2336
ref.2364
ref.44501
Protection against knocks (IK): 09 Power supply (V): 12Vdc Cons. (mA) without door release: 55 Operating temperature: 0 to 60ºC
Private WG centralized
Bruto Private WG (ref.4510)
Technical features
Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers let you equip the access control installation with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by door controller (ref.4420). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: open door / closed / power supply.
Programmation
Programming from PC software PC corresponding to installed Central Unit (ref. 2405 or ref.4410).
Power supply 12 Vdc
CENTRALIZED
Proximity card reader with capacity up to: - 1.020 users with MDS central unit (ref.2405). - 2.048 users with CAC central unit (ref.4410). Vandal-proof panel. Flush or surface mounted (ref.2778). Recommended for interiors and exteriors. Ideal for troubled zones or districts, offices, banks, etc. Door controller (ref.4420) required for operation.
Installation Up to 64 Central Units 2 wires
2 wires
twisted pair
twisted pair
twisted pair
Central Unit (ref.2405 or 4410)
2 wires
7 wires
( restricted area )
PRIVATE ACCESS CONTROL
Door Controller (ref.4420)
........
Central Unit (ref.4410)
1
2
4
5
6
1
2
3
7
8
9
4
5
6
A
0
B
3
Up to 32 readers
7
8
9
A
0
B
........
1
2
3
4
5
6
7
8
9
A
0
B
Up to 32 readers
7 wires 2 wires ( restricted area )
PRIVATE ACCESS CONTROL
Reader
twisted pair
2 wires 1
2
3
A
4
5
6
0
7
8
9
B
Reader
twisted pair
1
2
3
4
5
6
7
8
9
A
0
B
Reader
Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)
For replacement with magnetic strip.
Proximity keyring
ref.2364
ref.44501
Up to 32 readers
Identifiers
Specifications
ref.23361
ref.2336
ref.2363
Dimensions (WxHxDmm): 135x130x18 Flush box (included): 115x100x45 Surface box (WxHxDmm): 135x131x42 Environmental protection (IP): 53 Protection against knocks (IK): 09 Power supply (V): 12Vdc
Cons. (mA) without door release: 30 Operating temperature: 0 to 60ºC Reading distance (card/keyring): 4/2 cm PC Interface: RS-485/USB
61
Private WG centralized
Private Loft WG (ref.4560)
CENTRALIZED
Proximity card reader with capacity up to: - 1.020 users with MDS central unit (ref.2405). - 2.048 users with CAC central unit (ref.4410). Manufactured in ABS plastic. Surface mounted. Recommended for exteriors. Ideal for office screen profiles. Door controller (ref.4420) required for operation. Includes a 50 cm cable.
Technical features
Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers let you equip the access control installation with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by door controller (ref.4420). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. Built-in status LEDs: open door / closed / power supply.
Programmation
Programming from PC software corresponding to installed Central Unit (ref.2405 or ref.4410).
Power supply 12 Vdc
Installation
Up to 64 Central Units 2 wires
2 wires
twisted pair
twisted pair
twisted pair
Central Unit (ref.2405 or 4410)
2 wires
7 wires
.........
1
2
4
5
7
8
9
A
0
B
Central Unit (ref.4410)
3
1
6
2
3
4
5
6
7
8
9
A
0
B
........
1
2
3
4
5
6
7
8
9
A
0
B
Door Controller (ref.4420) Up to 32 readers
Up to 32 readers
7 wires
2 wires
Reader
twisted pair
2 wires 1
2
3
A
4
5
6
0
7
8
9
B
Reader
twisted pair
1
2
3
4
5
6
7
8
9
A
0
B
Without personalizing Without Customizable and without personalizing and with (photo, name, magnetic strip. magnetic strip. company...)
For replacement with magnetic strip.
Proximity keyring
Reader
Up to 32 readers
Identifiers
Specifications 62
ref.23361
ref.2336
Dimensions (WxHxDmm): 60x130x23 Environmental protection (IP): 66 Protection against knocks (IK): 06 Power supply (V): 12Vdc Cons. (mA) without door release: 40
ref.2336
ref.2364
Operating temperature: Reading distance (card/keyring): PC Interface:
ref.44501 0 to 60ºC 8/6 cm RS-485/USB
Key Button centralized
City key button MDS (ref.23261)
Technical features
Exit pushbutton input, door sensor input and electric lock relay. 2-wire cables for power supply and twisted pair for data. Dip switch to encode door number and electric lock activation timing. Requires external relay (ref.2013) if activating electric lock with consumption over 500mA, inverted function or external device (motor, barrier).
Programmation
Programming from PC software corresponding to installed Central Unit (ref.2405 or ref.4410).
Power supply 12 Vdc
CENTRALIZED
Access control reader whose operation is based on physical contact between the reader head (socket) and authorized identifier (plug ref.2328). Number of users: - 1.020 users with MDS central unit (ref.2405). - 2.048 users with CAC central unit (ref.4410). Manufactured in aluminium. Flush or surface mounted. Recommended for interiors and exteriors. No door controller required (ref.4420).
Installation
Up to 64 Central Units 2 wires
Central Unit (ref.2405 or 4410)
2 wires
2 wires
twisted pair
twisted pair
twisted pair
........
1
2
3
4
5
6
7
8
9
A
0
B
Central Unit (ref.4410)
Up to 32 readers 2 wires
Reader
twisted pair
1
2
3
4
5
6
7
8
9
A
0
B
........
1
2
3
4
5
6
7
8
9
A
0
B
Up to 32 readers
2 wires 1
2
3
A
4
5
6
0
7
8
9
B
Reader Up to 32 readers
twisted pair
1
2
3
4
5
6
7
8
9
A
0
B
Reader
Identifiers Specifications
Key button identifier (ref.2328). Dimensions (WxHxDmm): 130x128x18 Flush box (included): 115x114x45 Surface box (WxHxDmm): 130x128x33 Environmental protection (IP): 43
Protection against knocks (IK): 07 Power supply (V): 12Vdc Cons. (mA) without door release: 25 Operating temperature: 0 to 60ºC
63
Key Button WG centralized
City key button WG (ref.2315)
Technical features
Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers let you equip the access control installation with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by door controller (ref.4420). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols.
Programmation
Programming from PC software corresponding to installed Central Unit (ref.2405 or ref.4410).
Power supply 12 Vdc
Installation Up to 64 Central Units 2 wires
Central Unit (ref.2405 or 4410) twisted pair
CENTRALIZED
Access control reader whose operation is based on physical contact between the reader head and authorized identifier (ref.2328). Number of users: - 1.020 users with MDS central unit (ref.2405). - 2.048 users with CAC central unit (ref.4410). Manufactured in aluminium. Flush or surface mounted. Recommended for interiors and exteriors. Door controller (ref.4420) required for operation.
2 wires
2 wires
twisted pair
twisted pair 1
7 wires
........
Door controller (ref.4420)
2
Central Unit (ref.4410)
3
4
5
6
7
8
9
1
2
3
A
0
B
4
5
6
Up to 32 readers
7
8
9
A
0
B
........
1
2
3
4
5
6
7
8
9
A
0
B
Up to 32 readers
7 wires
2 wires
2 wires
Reader
twisted pair
1
2
3
A
4
5
6
0
7
8
9
B
Reader
twisted pair
1
2
3
4
5
6
7
8
9
A
0
B
Reader
Up to 32 readers
Identifiers Specifications
64
Key button identifier (ref.2328). Dimensions (WxHxDmm): 130x128x18 Flush box (included): 115x114x45 Surface box (WxHxDmm): 130x128x33 Environmental protection (IP): 43
Protection against knocks (IK): 07 Power supply (V): 12Vdc Cons. (mA) without door release: 30 Operating temperature: 0 to 60ºC
Key Button centralized
Bruto key button MDS (ref.2554)
Technical features
Exit pushbutton input, door sensor input and electric lock relay. 2-wire cables for power supply and twisted pair for data. Dip switch to encode door number and electric lock activation timing. Requires external relay (ref.2013) if activating electric lock with consumption over 500mA, inverted function or external device (motor, barrier).
Programmation
Programming from PC software corresponding to Central Unit installed (ref.2405 or ref.4410).
CENTRALIZED
Access control reader whose operation is based on physical contact between the reader head and authorized identifier (ref.2328). Vandal-proof panel. Manufactured in aluminium. Flush or surface mounted. Reader and controller integrated in the same module. Recommended for interiors and exteriors. Ideal for troubled zones or districts, offices, banks, etc. No door controller required (ref.4420).
Power supply 12 Vdc
Installation Up to 64 Central Units 2 wires
Central Unit (ref.2405 or 4410)
2 wires
2 wires
twisted pair
twisted pair
twisted pair
........
2
3
4
5
6
7
8
9
A
0
B
Up to 32 readers 2 wires
Reader
1
Central Unit (ref.4410)
twisted pair
1
2
3
4
5
6
7
8
9
A
0
B
........
1
2
3
4
5
6
7
8
9
A
0
B
Up to 32 readers
2 wires 1
2
3
A
4
5
6
0
7
8
9
B
Reader Up to 32 readers
twisted pair
1
2
3
4
5
6
7
8
9
A
0
B
Reader
Identifiers Specifications
Key button identifier (ref.2328). Dimensions (WxHxDmm): 135x130x18 Flush box (included): 115x100x45 Surface box (WxHxDmm): 135x131x42 Environmental protection (IP): 53
Protection against knocks (IK): 09 Power supply (V): 12Vdc Cons. (mA) without door release: 25 Operating temperature: 0 to 60ºC
65
Radiofrequency centralized
Digital RF emitter (ref.24651) Radio frequency emitter 433,92 MHz. Digital Technology. New and highly robust design. Dual channel emitter that can trigger two relays. Secure, unique, non configurable code exclusive series per emitter. Emitters must be authorized/cancelled in the receivers.
Technical features
Unique and exclusive code per emitter. Includes 12Vdc battery. Range: 30m. Frequency: 433,92 MHz. Consumption in transmission: 10mA Consumption in standby: 0.1mA
CENTRALIZED
Power supply 12 Vdc
Installation
2
twisted pair RF emitter ref. 24651
Compatible with
RF Receiver ref. 1065
Central Unit ref.4410
Ref.7960 Villa Receiver (stand-alone).
Ref.1065 MDS Receiver (centralized).
Ref.2464 Secondary MDS Receiver (centralized).
Specifications
66
Dimensions (WxHxDmm): 53x42x12mm
Radiofrequency centralized
RF Dual emitter (ref.25511) Radio frequency emitter 433,92 MHz. Dual technology. New and highly robust design. Dual channel emitter that can trigger two relays. Secure code, unique, non configurable and exclusive as standard per emitter. Emitters must be authorized/cancelled in the receivers. Internally integrates proximity card electronics so can be used as a dual channel emitter or a substitute identifier for proximity cards or keyrings.
In addition to the RF functions, incorporates proximity card electronics for use in proximity reader. Includes 12Vdc battery. Range: 30m. Proximity reader range: 2 cm. Frequency: 433,92 MHz. Consumption in transmission: 10mA Consumption in standby: 0.1mA
CENTRALIZED
Technical features
Power supply 12 Vdc
Installation
2
twisted pair RF emitter ref.25511
Compatible with
RF receiver ref.1065
Central Unit ref.4410
Ref.7960 Villa Receiver (stand-alone).
Ref.1065 MDS Receiver (centralized).
Ref.2464 Secondary MDS Receiver (centralized).
Specifications
Dimensions (WxHxDmm): 53x36x13mm
67
Radiofrequency centralized
MDS Receiver (ref.1065) Single channel receiver 433.92MHz Digital Technology. When code emitted by the digital (ref.24651) or dual (ref.25511) remote control is received, the receiver closes the circuit activating the electric lock or automatic door. Mounted in watertight box (IP65) in ABS.
Technical features
Includes rigid antenna, 25 cm. Optionally, by adding card (ref.7934), we can convert the receiver into dual channel. Reception frequency: 433,92 MHz. Sensitivity: 3 mV Relay contact: 2 A max. Power supply: 12Vdc Consumption: 110 mA in standby. Dip-switch to configure access number.
CENTRALIZED
Power supply 12Vdc
Up to 64 Central Units 2 wires
2 wires
twisted pair
twisted pair
twisted pair
2 wires
Central Unit (ref.2440 or 2405) 1
2
3
4
5
6
7
8
9
A
0
B
........
1
2
4
5
3 6
7
8
9
A
0
B
Up to 32 readers 2 wires
2
3
5
6
7
8
9
A
0
B
1
........
4
2 5
3 6
7
8
9
A
0
B
Up to 32 readers
2 wires
twisted pair Receiver
1 4
1
2
3
4
5
6
7
8
9
A
0
B
twisted pair Video panel
Reader
Up to 32 readers
Emitter RF Ref.79561
Compatible with
Digital emitters (ref.24651)
Dual emitters (ref.25511)
Specifications 68
Dimensions (WxHxDmm): 90x165x55mm
Fingerprint WG centralized
City Fingerprint WG (ref.6990)
Technical features
Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers let you equip the access control installation with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are builtin. These functions are supported by door controller (ref.4420). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. 2 status signal LEDs: door open/closed. Display 7 3-digit segments. Infrared receiver for programming. Programmable relay timings (monostable, bistable).
Programmation
Programming from PC software corresponding to Central Unit installed (ref.2405 or ref.4410).
Power supply 12Vdc
CENTRALIZED
Fingerprint reader with thermal sensor with storage capacity: - 1.020 users with MDS central unit (ref. 2405). - 2.048 users with CAC central unit (ref.4410). Operating mode: 1 or 2 fingerprints per person. Manufactured in aluminium in new City style. Flush or surface mounted. Recommended for interiors and exteriors. Reader and controller separated. Door controller required (ref.4420).
Installation Up to 64 Central Units 2 wires
2 wires
2 wires
twisted pair
Central Unit twisted pair (ref.2405 or ref.4410)
7 wires
Door Controller (ref.4420)
twisted pair
2
3
4
5
6
7
8
9
A
0
B
1
........
2
3
4
5
6
7
8
9
A
0
B
Up to 32 readers
1
2
3
4
5
6
7
8
9
A
0
B
1
........
2
3
4
5
6
7
8
9
A
0
B
Up to 32 readers
2 wires
2 wires
1
2
3
A
4
5
6
0
7
8
9
B
twisted pair
twisted pair Reader
1
Video panel
Audio panel
Up to 32 readers
Specifications
Dimensions (WxHxDmm): 130x128x18 Environmental protection (IP): 43 Flush box (included): 115x114x45 Protection against knocks (IK): 07 Surface box (WxHxDmm): 130x128x33 Operating temperature: 0 to 60ºC
69
Fingerprint WG centralized
City fingerprint module WG (ref.6989)
CENTRALIZED
Fingerprint reader with thermal sensor with storage capacity: - 1.020 users with MDS central unit (ref. 2405). - 2.048 users with CAC central unit (ref.4420). Fitted in CityMax audio or video door entry system outdoor panel spare spaces for enhanced security in the home. Door controller (ref. 4420) required for operation.
Technical features
Output in Wiegand-26 bit or Dataclock format. Wiegand (WG) readers let you equip the access control installation with anti-sabotage security, as neither the door opening mechanism nor the exit button connection are built-in. These functions are supported by door controller (ref.4420). The reader can be used with other door controllers using Wiegand-26 or Dataclock protocols. 2 status signal LEDs: door open/closed. Display 7 3-digit segments. Infrared receiver for programming. Programmable relay timings (monostable, bistable).
Programmation
Programming from PC software corresponding to installed Central Unit (ref. 2405 or ref. 4410).
Installation
The audio or video door entry panel is located on the outside. It is possible to set up a configuration in the panel intuitively including a reader (ref.6989) for greater security and more convenient access.
Power supply 12Vdc
Up to 64 Central Units 2 wires
2 wires
2 wires
twisted pair
twisted pair
twisted pair
Central Unit (ref.2405 or ref.4410)
2
3
4
5
6
7
8
9
A
0
B
........
1
2
3
4
5
6
7
8
9
A
0
B
Up to 32 readers
2 wires
1
2
3
4
5
6
7
8
9
A
0
B
........
1
2
3
4
5
6
7
8
9
A
0
B
Up to 32 readers
2 wires
twisted pair Reader
1
twisted pair Video panel
Reader
Up to 32 elements
Specifications 70
Environmental Protection (IP): 43 Protection against knocks (IK): 07 Power supply (V): 12Vdc
Cons. (mA) without door release: 6/60 Relay contact: 2A (NA,NC) Operating temperature: 0 to 60ºC
Fingerprint Reader centralized
Fingerprint (ref.4470)
Technical features
Dual technology: fingerprint and Mifare proximity card. The reader compares the fingerprint stored in the card and the sample read by the sensor. Power supply 12Vdc. 2-wire cables for power supply and twisted pair for data. One Mifare card (ref.4440) required for each user.
Programmation
Programming from PC software corresponding to installed Central Unit (ref.2405 or ref.4410). Card programmer (ref.4460) required to memorize fingerprint samples in the Mifare cards.
Identificadores
CENTRALIZED
Fingerprint reader with optical sensor and capacity to store: - 1.020 users with MDS central unit (ref.2405). - 2.048 users with CAC central unit (ref.4410). Surface mounted for interiors. Door controller (ref.4420) required for operation.
Mifare card with memory (ref.4440).
Power supply 12Vdc
Installation Up to 64 Central Units 2 wires
2 wires
twisted pair
Central Unit (ref. 4410 or ref.2405) twisted pair
2 wires
Door Controller (ref.4420)
twisted pair
1
2
3
4
5
6
7
8
9
A
0
B
........
1
2
3
4
5
6
7
8
9
A
0
B
Up to 32 readers
1
2
3
4
5
6
7
8
9
A
0
B
1
........
4
2 5
3 6
7
8
9
A
0
B
Up to 32 readers
7 wires 2 wires
2 wires 1
3
5
6
8
9
A
0
B
twisted pair
twisted pair Reader
2
4 7
Video panel
Reader
Up to 32 readers
Specifications
Power supply (V):
12Vdc
71
Accessories common to all systems.
Accessories
Accessories stand-alone/stand-alone in network/centralized
Electric Lock
ACCESSORIES
3051 3052
Squares for emagnetics door lock:
E E E E E E M 300Kg M 500Kg M 300Kg
N N N N I I
12Vac 12Vac 12Vdc 12Vdc 12Vdc 12Vdc
I
12/24 Vdc
era Op -40 -40 -40 -40 -40 -40
+120ºC +120ºC +120ºC +120ºC +120ºC +120ºC
E E E E E E
250
229x39x26
-40 a +120ºC
E
250
229x39x26
-40 a +120ºC
S
250
229x39x26
-40 a +120ºC
S
• •
a a a a a a
Flu Su sh rfa ce
tem ting
ion ens
21x75x27 20x101x28 20x101x28 20x101x28 20x101x28 20x101x28
•
500 I
12/24 Vdc 500
I
12/24 Vdc
- For doors that open from inside to outside. - For doors that open from outside to inside.
74
Dim
sen Do
or
nsu Co 780 780 150 150 150 150 500
s
sor
tio mp
up rs we Po
No Inv rmal ert ed
ref. 3071 2953 2958 29580 2967 29670 3050
Ele eM ctric agn etic
ply
n (m
A)
per
atu
re
centralizado
Device that lets you unblock the door temporarily in safe conditions: identifier accepted or opening from inside by means of the exit button. There are several models distinguished by different operating features, installation and power supply. Depending on the type of protection against electrical power cuts: Normal operation (fail secure). The door is unblocked when the electric lock is powered. As an advantage, if there is a power cut the door does not unlock. The NO (normally open) terminal is connected from the electric lock relay. Inverted operation (fail safe). The door remains blocked while the electric lock is powered. It is unlocked by cutting off the power. An advantage is that if there is a power cut, the door does not block (fire systems). According to the type of installation, there are: Electrical lock/door release. Recommended in installations where we want to combine with the traditional lock and are normally installed embedded in the door frame. When activated, releases the latch to allow the door to open. Electromagnetic door release. Usually installed when there are security requirements against fire: outward opening doors, power shutoff during the fire alarm to facilitate evacuation. They are inverted type. An iron strip is placed in the leaf of the door and an electromagnet in the frame so that when the door is closed their faces are touching. The door stays closed while the electromagnet attracts the strip. Depending on the force with of attraction, it can resist pulling or pushing to try to open the door. The force is usually measured in Kg. When there is no space in the door frame to fit the lock or if we do not want to drill it, it can be mounted on the wall with special brackets. According to the type of power supply, there are: DC current. Characterized by being quiet. Inverted operation electric locks must be this type. AC current. They are noisy compared with DC locks. They generally have a higher consumption and work better in doors subject to some type of pressure: wind, bolt friction, etc. There are door release models with a built-in door sensor to detect if the door stays open accidentally.
ref.3077 Square for ref.3051 ref.3079 Doble square Z ref.3078 Square for ref. 3052
Accessories stand-alone/stand-alone in network/centralized
Power Supplies When choosing a suitable power supply it is necessary to consider the consumption of all the elements in the system, especially the electric lock. It is recommended to use a magneto-thermal switch not shared with any other equipment to avoid power supply disconnections caused by them. It is recommendable to use an emergency supply system (with battery) to prevent doors blocking or unblocking in the event of power cuts. In centralized installations with long distances it will be necessary to place additional power sources in the access to prevent tension drops in the wiring.
REF. 4800 POWER SUPPLY 12VAC/1,5A Recommended for stand-alone readers when we want to use AC locks. DIN4. ref.4800
REF. 8791 EMERGENCY POWER SUPPLY 12Vac/1,5A Includes Ni-Cd battery 750mA. In emergency supplies 12Vdc. Includes Ni-Cd battery 750mA. In emergency supplies 12Vdc. REF. 4813 POWER SUPPLY 12VDC/2A General installation power supply for centralized system. REF. 2060 BATTERY ADAPTER 12VDC Installed between 12Vdc power supply and the system. With external Lead-Acid battery connection. If the input tension falls below 11Vdc it switches automatically to the battery. REF. 2070 BATTERY 12V/2,2A Lead-Acid battery without maintenance for small installations or an access power supply.
ref. 4813
ref.2060
ACCESSORIES
REF. 2337 BATTERY 12V/ 7A Lead-Acid battery without maintenance for large installations.
75
Accessories stand-alone/stand-alone in network/centralized
Door Sensor REF. 1076 MAGNETIC CONTACT Surface installation between door and frame. Connected to the door sensor input of the controllers.
Power Cutoff REF. 4475 POWER CUTOFF Lets you disconnect the electrical current to the devices in a room when the user is not in. For connection, it is necessary to introduce the user proximity card in the cutoff (only works with proximity cards). When the user leaves the room they remove the card from the cutoff and then have 10 seconds courtesy to leave the room. Designed to be used as a complement to the stand-alone or centralized proximity readers, since the same cards are used. The user is obliged to remove the card from the cutoff; otherwise they will not be able to open the door of the room.
centralizado
Embedded installation in mechanism box 60x70mm. Operating at 230V. Cutoff power: 6000W. Proximity technology: EM, TEMIC, RF256 and TK cards.
Desktop Proximity Reader Lets you authorize proximity identifiers quickly and easily by PC with management software. PC connection: RS-232. Cable included. Power supply 230Vac by adaptor (included).
ACCESSORIES
230Vac power supply
3
installation
RS-232 ref.2349
76
Accessories stand-alone in network/centralized
PC Management Modules The system operating mode configuration, user authorizations and cancellations and restrictions are handled via PC and sent to the central unit so that it works independently. The information generated by the installation (events) must be communicated to the PC in real time. To set up these communications, the PC must be connected to the central unit. The connection can be made locally or remotely, using one of the following devices:
Adaptor RS-232 to RS-485 (ref.2338) Connection between PC and central unit (or network of CUs). Also lets you connect the modem to the central unit for remote management. PC connection: RS-232 max. 30 mts. (cable 3 mtrs included). Connection to central: RS-485 (twisted pair). Max. 1200 mts. DIN6 format (surface mounted and DIN rail). Power supply 230Vac.
Adaptor RS-232 to RS-485 (ref.2466) Programming of addresses and parameters to decoders from the PC. Used for maintenance of facilities that do not have the PC permanently connected, as an installer tool. Includes an RS-232 cable with DB-9 connector for PC connection.
ref. 2466 3 RS-232 2
ref.2338
twisted pair
IP Adaptor (ref.1087)
2 3 RS-232 twisted pair 2
RS-485
Adaptor USB to RS-485 (ref.24661) Connection between PC (USB) and central unit. Direct power supply from USB. Includes driver.
Communication between management PC and the installation using IT network (Ethernet), avoiding additional wiring. Connection to central unit by programmer (ref. 2466). An IP address must be configured to connect to the network using the software included. Remote management via Internet if the protection devices (Firewall) in the IT installation allow it (specialized personnel required to configure router for Internet access).
Power supply 230Vac by adaptor included. Ethernet connection RJ45.
ACCESORIES
230 Vac
ref.1087 ref. 2466 3 RS-232 2
Ref.24661 2 RS-485 twisted pair
RJ-45
RJ-45 IP PC
twisted pair
USB PC
77
Accessories centralized
Technical Alarms and Automation Several sensors may be connected to the installation (up to 1000) to carry out automated activities based on the source of the detection. The sensors must be potential free contact, such as switches, pushbuttons, magnetic contacts, volumetric detectors, photoelectric barriers, etc. These sensors are managed by 'sensor decoders’, with capacity for 8 entrances, and connected to the central unit by the decoder bus, from which it is powered. NA or NC operating mode and the type of trigger (instant or delay up to 127 minutes) must be configured. For each group (100 sensors), the actions to take are indicated (not exclusive): Communicate the incident to the central console (security post). Activate one or several relays (ref. 2430) (always the same or different depending on the sensor). Switch status of a relay. Monitor the incident on the control computer (control post). Activate the electric lock of a given door. Subordinate the action to the simultaneous activation of another sensor (double signalling to avoid false alarms). Sensors can be enabled and disabled during a set schedule by means of the schedule planner or from the access control readers, when a user identifier associated with a sensor is presented.
centralizado
The most frequent applications of the sensors are the following: Technical alarms: Alarm messages in the PC control. Power failure, water leak, intrusion, etc... Construction of pushbutton panels for timed activation of devices: vehicle barriers, opening doors, hallway lighting, etc. Door blocking depending on the status of other doors.
SENSOR DECODER ref.2429
ACCESSORIES
In the installation it is possible to connect up to 1000 relays in the same decoder bus, to activate different devices in response to the activation of sensors or trigger them independently. The relays are implemented by 'relay decoder' containing 8 2 Amp. relays with NA and NC output. The relay decoder connects to the decoder bus, which powers it. For each output, timing (1 to 255 seconds or indefinite) and the initial status (active or standby) are configured.
RELAY DECODER ref.2430
78
There are several ways to trigger the relays: Schedule planner: activates and deactivates relays according to a set weekly schedule (up to 32 daily plans). From the access control readers. Each user can have a relay associate with their identifier so that when it is presented, the associated relay status is switched while activating the door release. From the central guard - unit. Any relay can be activated or deactivated by entering its number and the desired status (active / standby). When a sensor or combination of sensors is activated. When the maximum capacity of a zone is reached. When there is someone in a zone.
Typical applications are: Automatic connection and disconnection of devices: heating, refrigeration, lighting, etc. Alarms connection and disconnection. Activation of sirens and warning lights. Unblocking of doors during a set schedule.
Specifications Programming the sensor and relay decoders is done with the decoder programmer (ref. 2466).
Dimensions (WxHxDmm): Nº devices Maximum capacity/central Activation type Prog. detection/activation Detection/activation. Power supply Consumption (mA) min/max. Temperature operating:
SENSOR DECODER
RELAY DECODER
175x90x37 8 inputs
175x90x37 8 outputs 1000
Potential free contact 26 sec. 1sec./127 min. 10 -10ºC to +60ºC
2 A NC/NA 1 sec. 1..255 sec./indefinite 12Vdc 7/170 -10ºC to +60ºC
Desktop guard unit
In installations with several guard units all calls and alarms can be centralized in one main guard unit. To be connected to the door bus by means of two additional wires for the audio (ref.5918).
ACCESSORIES
Can recieve calls from the interphone panels and allow access to visitors. Permits access management of any door within the installation. Receives sensor reports in the case of manipulated or open doors.
ref.2537
From the main guard unit a simple user configuration can be done (without restrictions), no PC configuration necessary. PANEL DECODER Dimensions (WxHxDmm): Power supply: Consumption (mA) min/max.: Operating temperature:
175x90x37 12 Vdc 15/30 -10ºC to +60ºC
MAIN GUARD UNIT 215x205x250 12 Vdc 300 -10ºC to +60ºC
ref.5918
79
Index of references
80
REF.
DESCRIPTION
01065 01087 02013 02060 02070 02133 02260 02263 02268 02288 02306 02315 02328 02336 02337 02338 02347 02349 02351 02363 02405 02429 02430 02464 02466 02520 02523 02552 02553 02554 02560 02561 02778 02953 02958 02967 03050 03051 03052 03071 03077 03078 03079
RF MDS RECEIVER REMOTE MANAGEMENT IP MODULE RELAY STAIRS LIGHT EMERGENCY BATTERY MODULE 12V EMERGENCY BATTERY 12V-2 A. BRUTO KIT MEMOKEY STAND-ALONE CITY KIT PRIVATE STAND-ALONE CITY PROXIMITY READER STAND-ALONE MODULE BRUTO PROXIMITY MDS MODULE BRUTO PROXIMITY READER STAND-ALONE MODULE PROGRAMMATION KEYPAD PRIVATE READER KEY-BUTTON READER WG KEY BUTTON IDENTIFICATOR PROXIMITY CARD WITH MAGNETIC STRIPE BATTERY 12VDC.6,5AMP DIN TERMINAL DIG.FX-L 220V CITY PRIVATE READER STAND-ALONE CITY PRIVATE READER DESKTOP PROGRAMMING KIT WINPROX PROXIMITY CARD WITHOUT MAGNETIC STRIPE CENTRAL UNIT MDS DECODER OF 8 SENSORS MDS DECODER OF 8 RELAYS MDS SECUNDARY RF RECEIVER PC INTERFACE DECODER CITYMAX MEMOKEY MODULE BRUTO MEMOKEY MODULE BRUTO PROXIMITY READER MDS BRUTO MDS DIGITAL KEYPAD BRUTO KEY-BUTTON READER MDS CITY PROXIMITY MDS MODULE CITY KEYPAD MDS MODULE BRUTO 1 SURFACE BOX MODULE DOOR LOCK MOD.3000N-S DOOR LOCK N-412-S DOOR LOCK N-512-S FLUSH EMAGNETIC DOOR LOCK 300Kg EMAGNETIC SURFACE DOOR LOCK 500Kg EMAGNETIC SURFACE DOOR LOCK 300Kg UNIVERSAL MOD.450N-S DOOR LOCK SQUARE L-2 FOR REF.3051 SQUARE L-3 FOR REF.3052 DOUBLE SQUARE
Index of references REF.
DESCRIPTION
03591 03491 03600 03610 03619 03620 03621 03623 03624 04410 04420 04440 04460 04470 04475 04476 04477 04478 04480 04490 04500 04510 04520 04530 04540 04550 04560 04642 04698 04699 04800 04810 04813 06988 06989 06990 07900 07903 07910 07911 07912 07952 07960
CITY MEMOKEY CR 230V KIT DIN RAIL 12 VDC 12A RELAY KIT MEMOKEY CITY STAND-ALONE CITY MEMOKEY READER STAND-ALONE CITY PRIVATE KIT WITH PROXIMITY KEYRINGS CR MEMOKEY 100 CODES KEYPAD CR MEMOKEY 100C. CONTROLLER LOFT MEMOKEY STAND-ALONE KIT KIT PRIVATE LOFT STAND-ALONE CAC CENTRAL UNIT DOOR CONTROLLER WITHOUT MEMORY MIFARE PROXIMITY CARD FINGERPRINT PROGRAMMER FINGERPRINT READER ENERGY CUTOFF CITYMAX BLUETOOTH MODULE CITY BLUETOOTH READER BLUETOOTH READER KIT CITY MEMOKEY/PROXIMITY WG CITY PROXIMITY READER WG BRUTO MEMOKEY MODULE BRUTO PROXIMITY READER WG BRUTO 1 PRIVATE MODULE LOFT PROXIMITY READER STAND-ALONE LOFT MEMOKEY READER STAND-ALONE LOFT MEMOKEY/PRIVATE READER WG LOFT PRIVATE READER WG MARINE FLUSH BOX ST-2 MARINE PROXIMITY READER MODULE STAND-ALONE MARINE MEMOKEY KEYPAD POWER SUPPLY 12VAC/1,5A POWER SUPPLY DIN10 230VAC/12VAC+18VDC-1.5A POWER SUPPLY 12VDC/2A CITY FINGERPRINT READER KIT CITY FINGERPRINT MODULER READER CITY FINGERPRINT READER SINGLE CHANNEL 433Mhz RF RECEIVER RF RECEIVER FOR SHOPS 433Mhz - 230 V RADIOFRECUENCY FOR SHOPS KIT STANDARD RADIOFRECUENCY KIT SECURITY RADIOFRECUENCY KIT RF RECEIVER FOR GARAGES RF VILLA RECEIVER
81
Index of references
82
REF.
DESCRIPTION
08791 08851 22371 23261 23291 23351 23361 24651 24661 25511 29518 29628 44201 44501 79561
EMERGENCY POWER SUPPLY 12VAC/1,5A CITY SUPERFACE BOX SERIES 1 BRUTO KEYPAD MDS MODULE MDS KEY BUTTON READER CITY MEMOKEY READER MDS CITY PRIVATE READER MDS STANDARD PROXIMITY CARD WITHOUT MAGNETIC STRIPE RF SEGURITY EMITTER USB CONVERTER RF DUAL EMITTER DOOR LOCK AD-2005 DOOR LOCK MOD.N-424-S MAX DOOR CONTROLLER WITH MEMORY PROXIMITY KEYRING RF TRINARY EMITTER
A C C ES S C ON TRO L 1 Edi t i on . M a rc h 2 0 0 9 st
PU00430
Audio and Video Door Entry Systems www.fermax.com