Preview only show first 10 pages with watermark. For full document please download

Access Control - Oz Security Systems

   EMBED


Share

Transcript

WARNING : TO PREVENT FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE RISK OF ELECTRIC SHOCK DO NOT OPEN Access control Small apartment intercom system CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER(OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO AUTHORIZED SERVICE PERSONNEL This symbol is intended to alert the user to the presence of uninsulated“dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. This symbol is intended to alert the user to the presence of important operating and maintenance(servicing) instructions in the literature accompanying the appliance. IMPORTANT SAFETY INSTRUCTIONS NOTE: Although the Doorbell itself is weather-resistant it is not waterproof. Choose a sheltered location (e. g., porch), so the unit is not directly exposed to shines. Read the user manual before installing it and retain it for future reference. Unplug this product from power outlet before cleaning with a damp (not wet) cloth. Do not clean with liquid cleaners, aerosol cleaners, gasoline or other type of flammable fluids. Keep it away from heat, heaters, oil and water, for example, near bath tubs, wash basins, kitchen sinks, or laundry tubs, in a wet basement or near a swimming pool. Never spill liquid of any kind on this product. Do not overload power outlet or extension cords. Do not attempt to service this product yourself. INSTALLING INSTRUCTION Small apartment intercom system Small apartment intercom system 5.Warning When the monitor is on, pressing siren for alarm purpose. Contents warning button will make a loud 6.MUSIC RING CHIME OPTION 1.Performances and specifications 2 2.Components 3-4 5-8 3.Installation 4.System operation 5.Instructions for Indoor Extension ONLY FOR HAND-FREE MODELS Under standby mode, depress 2 seconels and release, the system goes to ring chime options, press to select the chime your prefer .and Press to exit the selection 7.EXTENSION PROGRAMMING Depress the UNLOCK button until a long time beep sounds and the system shifts to Extension Programming mode. And then follows steps as below to assign room number to an extension. For example: we are going to assign the number 302 to extension (indoor station) . Floor Number: The maximumfloor number is 9. Number of floor is 3 , then press monitor button for 3 times and press unlock button to finish the setting of floor no.. There will be two times short beep after finishing setting and guide to room coding consecutively. Room Number: The room n umber is 02 ,likewise press monitor twice.Then finish the setting by pressing unlock button, subsequently one longtime beep sounds. The system returns to standby mode. Reprogram Floor & Room Number It is the same as programming. Notices: A. When pressing monitor button, there is always one short beep. B. While setting, time interval between operations is limited within 10 seconds; otherwise the operation will be aborted with two longtime beeps. C. Any mistake or overflow of maximum floor number capability happens, the system exits setting mode and shifts to standby mode automatically, subsequently two longtime beeps sound. Small apartment intercom system .Components This system consists of door entry station , indoor extensions . Please refer to the appearances and components as following diagram. Door Entry Station front view back view 21 22 20 NOTE: During operation, the key tone sounds once when keying, or any mistake, short DI beep sounds twice. During keying, if inputting digits by mistake, press clear button to Delete the wrong digits, and input again. The time interval when keying is not longer than 20 seconds. While operating, press password button to return to Previous mode. Microphone 8. Release the door by password. external cover Under standby mode following from step C. For example the unlock password series number is 020 and subpassword is 8888 . A. Press password button, and input series number 020 (picture25) firstly, and the screen shows CCC (picture26), B. Input 8888 (picture27)in succession, it's invisible. If password is accepted, screen shows series number., and door lock is released. Otherwise, screen shows --- (picture28)and two-longtime beep sounds, door remains locked. camera LED screen ID reader area speaker keypad 23 24 25 26 27 28 9. Release the door by ID card. V VIDEO VIDEO GND GND A AUDIO + + +18V +18V A Main Line 3 V 12 U U P 12 + GND PG V _ + Null Unlock- Unlock+ AUDIO A +18V + B Main Line Swipe the ID card close to the card reader area, if ID card is accepted , screen shows ID card' s series number and the Door lock is unlocked. 10. Short circuit inspection 29 If the short circuit happens to an audio or signal wire in one main line, the door entry station will cut the connection with the main line, but another line is not influenced. When calling, Screen shows ---I . The short circuit happens to the line B. When calling, screen shows I--- , the short circuit happens to the line A. When calling, screen shows -H- , the short circuit happens to both line A and B in Audio and video. 5 ID card programming/reset The system will assign a series number to each blank card , the series number consists of three digits. It is illustrated by assigning the series number 032 to a blank card. Under system setup mode following from step C. Press 8 and screen shows HHH (picture14). Input 032 , screen shows 032 (picture15). Make the ID card close to the card reader area, and swipe the card, a DI beep sounds if programmed successfully. Do please take the programmed ID card away immediately. After that, the screen shows 033 (picture16) for the next ID card, program next card without keying in the ID card series number. After finishing the programming, press Clear button to quit setup mode, or password button to return to previous mode. Small apartment intercom system Extension (Indoor Monitor) front view screen Handset Unlock Alarm Monitor Contrast Volume back view V A + VIDEO GND AUDIO +18V 13 14 15 6 Erase ID card record 16 Under system setup mode following from step C. For example an ID card with series number 055 . Press 9 to erase card from the system(picture17), screen shows ddd (picture18), Input 055 , screen shows don (picture19) if successfully, and the card becomes a blank card. After that, press Clear button to quit, or password button to return to previous mode. Extension (Hand free) front view Unlock Warn 17 18 19 7 Erase all the data The date includes all the information of ID cards, user passwords. The operation has no influence on the administrator password. All Under System Setup Mode. following from step C. Press 5 to be ready to erase all the data from the system(picture20), screen shows ALL (picture21), input the administrator's subpassword. After that screen shows progress bar: --- (picture22), and then the screen shows DON and system will quit to standby mode soon. Talk Monitor Speaker Screen Talk indicator lamp Power indicator lamp Brightness control Chroma control Call volume control back view V VIDEO GND A AUDIO + +18V 4 Small apartment intercom system Small apartment intercom system 11. Call extension Under standby mode following from step C. A. Call the extension by dialing the room number(picture30). Screen shows room number. If the room number is assigned then confirming ring returns. B. The call chime lasts 10 seconds, and if no answer after 30 seconds, system returns to standby mode. Press the Clear button to end the calling. C. If the room number is not assigned, or any mistakes, screen shows --- (picture31) and two longtime beep sounds, and system return to standby mode immediately. 12. Others .Performances and specifications A.System features 30 31 A. While under monitor mode, if any calls from the door entry station, the system will change to communicating mode. B. While under monitor mode, if any setup action done in the door entry station, the system will end the monitor mode and transfer to setup mode. .Instructions for Indoor Extension 1.Talk When visitors presses the call button on the door entry station, ring is heard at the monitor. You can pick up the handset and talk with the visitor. 2.Unlock After identifying of the visitors, you can directly unlock the electric door lock by pressing unlock button. And LED screen at the door shows The door phone is automatically off after 5 seconds. 3.Monitor Press monitor button, the camera area view is on screen. It is Off automatically by pressing it again. 4.Engaged Press Monitor button, there is DiDi beep from monitor when the door entry station is engaged. And please try again later. Maximum number of floor:9 Maximum user capacity: 32 Maximum key password user: 32 Maximum ID Card available: 480 Indoor monitor programming Wiring: in series connection System auto shut-off time: 30/60 seconds The maximum communicative distance:depending on wire applied according to PART B. System function Monitor from indoor monitor Remote door release Programming in indoor monitor Intercom with outdoor camera Bi-directional communicati ID card to release door lock Password to release door lock Auto shut-off Engaged tone C.Technical specification Door entry station DC input: 18V 500mA Power: 1.2W standby , 5W working Minimum illumination: 0.1 Lux Resolution: 400 TVL Signal standard system: PAL/NTSC View angle: 60 degree Video output: 1.0Vpp/75 Night vision resource: Infrared Audio response: 400~3400Hz 3dB Dimension: 32.6x12.5x4.5CM Working temperature: -0 ~40 Extension Power: 0.18W standby---15W working Reproduction ratio: 90% Brightness scale rate: 8 Screen: 4 B/W CRT or color LCD 5.6 TFT color LCD Sound: 0~70dB Sound level Ringing : 8 Audio: 400~3400Hz +-3dB Maximum ring time: 30 second Dimension: 22.8x19x7CM Working temperature: -0 ~40 Small apartment intercom system Small apartment intercom system . Installation 3.Reset the password A. accessories Outdoor camera Indoor monitor UPS Lock Door closer EM ID card 1pcs/set 1pcs/set 1pc Not provided by factory 1pcs Not provided by factory 1pcs Not provided by factory 3pcs Provided by factory B. Cable CAT5E Computer LAN cable Type Power GND Video Audio Connection 2 wire 4 wire 1 wire 1 wire Length 50m NormalLAN net cable Refer to the following connection diagram between door entry station and indoor monitors Brown (1wire) connect video V All white (4wire) connect GND Green (1wire) connect to Audio A Blue+ Orang e (2wir e)connect to indoor monitor + 18V e + + Net cable Optional wiring:Connect the video and GND short circuit by 100 Resistor and 103PF capacitor to get good communication when main line is over 20 meters Lock wire Lock 2 wires 0m Under System Setup mode following from step C. It is going to takes one example to illustrate: the series number is 020 , and the sub-password is 8888 .Press 1 to reset the user password, and screen shows LLL (picture7). Input series number 020 , and screen shows bbb (picture8). Then input subpassword 8888 (picture9), and screen shows 021 (picture2and 10)(series number plus 1) if password accepted by the system. And you can set the sub password for the series number 021 without keying in series After finishing the setup, press CLEAR button to quit the setup mode or press password button to return to the previous mode. 8 9 10 7 Default administrator password recovery. Open the back cover, and there are two weld joints shorted-circuit where SI is printed . Make it open-circuit and then a DI beep sounds, that's to say the administrator password recovery is done. 4 Erase password record Under system setup mode following from step C. For example, erase the series number 020 and its sub-password. Press 2 to erase user password, screen shows EEE (picture11),input series number 020 and screen shows don (picture12) if done. Press clear button to quit setup mode, or password button to return to previous mode. RW1.0m/wire mm2wire Outdoor camera + 2 wires 18V 11 5 12 10 Small apartment intercom system Small apartment intercom system .System operation c. Install diagram Setup of the door entry station It s recommended to weld each jonit of wires 1. Password format There are two kinds of password in the door entry station: Administrator password and User password. Each password consists of Series Number (Three Digits) and Sub-password (Four digits). Main line Main line Administrator password: It is used to set and reset the system. The default series number is 000 , and sub-password is 1234 . User password: Users use it to release the door lock. 2. Set the system (System setup mode) A. Depress Password Button until a longtime beep sounds, the LED screen shows PPP (picture1). B. Input the Administrator password series number 000 (picture2), after that, the screen shows CCC (picture 3) 1 2 C. Input the Administrator's sub-password is invisible but several (picture4). 3 1234 , the password If the password is correct, and the screen shows FFF (picture5) , after that you can go on with the following operations. If incorrect, screen shows --- and system returns to standby mode(picture6) . 4 9 5 6 6 Small apartment intercom system Small apartment intercom system D. Installation for the door entry station E. Installation for indoor monitors a.Flush mount at the door Drill and trim a hole on the door and a passage for wires Fix the flush case to the door with screws Connecting wire to the terminals on the camera Putting the door unit into the flush case and fix it with 2 screws Before installation, please choose the right position where screen is not exposed to shine. Please do as following steps: a.According to fixing hole of bracket, it needs to make 3-4 holes at 6mm, and put the expansion rubber plug into the hole. expansion rubber plug Door 304mm Flush case Fixing screws B.To use self-screw for fixing in the wall Mounting bracket 123mm Hole For flush case Size:304(L)X123(W)X36.5(D)mm wire b Install on the wall Wall Flush case c.After connecting the wire of the extension, hang the extension and pull off to make the taps into the mounting holes Fixing screws wire 7 8