Access Control | PAC 530 Output Controller Overview The PAC 530 Output Controller communicates directly with the PAC 500 Access and Alarm Server, ensuring complete system security, resilience and reliability, when integrated with Stanley PAC security management software. It often acts as a key component in elevator access control. The PAC 530 monitors and controls ten 2-Amp and two 8-Amp programmable output relays are configurable as latched, momentary, toggling or pulsing. Two control inputs are configurable as Normally Open (NO) or Normally Closed (NC), with optional supervision via three or four state monitoring allowing the connection of devices like alarms, motion detectors and temperature sensors. The Output Controller can also be used to integrate an elevator system within a Stanley PAC access control environment. Each PAC 530 can control up to 12 floors and multiple PAC 530s can be combined per car. Operating in conjunction with an PAC 500 and Two-Door Controllers (PAC 512 series) each floor is configured as an area and can be programmed with a specific period during which only access is possible to cardholders with appropriate access privileges. Options also include out of hours access and exit, together with an optional additional button selection time (ADA compliance). The One-Touch™ installation mode shows the state of each input and output providing instantaneous polling and communication status at the controller with just the press of a single button, avoiding the need for a PC, complex programming and DIP switch configuration. Key Features Ten Form-C 2-Amp contacts for load switching Two Form-C 8-Amp contacts for load switching Two programmable supervised or non-supervised user inputs 10.5 to 28VDC input power Dedicated override and tamper inputs Up to 48 output controllers can be multi-dropped via RS-485 from a single PAC 500 Connects to the PAC 500 via RS-485 Receives and processes real time commands from the PAC 500 Reports all activity to the PAC 500 Enables complex input and output linking with the PAC 500 and PAC 520 Status LEDs show the states of all Inputs and Outputs Watchdog timer for maximum reliability One-Touch installation test mode. This installer test facility enables the TM functionality of each controller and its associated circuits to be tested locally, by simply pressing a single button without the need for a PC or programming Elevator control Onboard RS-485 termination jumper One polyfused 100mA auxiliary voltage output AC status monitored and reported Downloadable firmware updates DIN-Rail mounting for ease of installation (removable) READYKEY ™ COMPATIBLE ELEVATOR CONTROL CCTV THE OUTPUT CONTROLLER IS A KEY COMPONENT IN AN ELEVATOR ACCESS CONTROL SYSTEM. IN NC NC TAMPER NC NO NO 2 www.stanleypac.com 1 0V INPUTS ALARM BEACON POWER VIN NO COM COM COM AIR CONDITIONING RELAY 1 One-Touch™ Testing To enter View Mode press the One-Touch button momentarily. To enter Active Mode press and hold the One-Touch button for 2 to 4 seconds. To leave One-Touch testing, press the button momentarily again. Note that One-Touch Active mode will automatically time out after 1 hour. For details of One-Touch modes see the enclosed Quick Start Guide . RELAY 2 0V MSTAT 0V SIG NC NO COM NC COM NO NO LED COM VOUT Made in UK Model No. PAC530 Output Controller X Date Code NC NC COM NC RELAY 12 NO RELAY 11 NO RELAY 10 COM NC NO NC VOUT 1-2 - VIN: 100mA RELAY 1-2 - 30V; 2A RELAY 11-12 - 30V; 8A 0V TAMP NGND NC NO NO COM COM NC VOUT2 0V 0V 0V TAMP OVRD MSTAT VOUT2 MSTAT www.stanleypac.com One-Touch™ Testing To enter Active Mode press and hold the One-Touch button for 2 to 4 seconds. To leave One-Touch testing, press the button momentarily again. Note that One-Touch Active mode will automatically time out after 1 hour. For details of One-Touch modes see the enclosed Quick Start Guide (17473). - + TX RELAY 3 RELAY 4 OUTPUT CONTROLLER (PAC 530) (12 OUTPUTS AND 2 INPUTS PER PAC 530) FUSE 2 TRIPPED FUSE 1 TRIPPED PLANT ELEVATOR CAB STATUS POWER BATTERY VIN Made in UK Model No. X Date Code READER 0V RS-232 0V N0 N1 OUT PAC 500 Access and Alarm Server This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may VOUT 1-2 - VIN; 5A CAUTION - INTERNAL BATTERY See manual for disposal of unit. INPUT: 10.5-28.0VDC; 0.4A (SERVER ONLY) RS-485 NGND NET2 RXNet MAINS ON POWER OUT RX RS-485 CTS N1 N0 NGND LAN TXNet TXNet This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. INPUT: 10.5-28.0VDC; 0.4A (CONTROLLER ONLY) TX 1416/2 COMPACT FLASH DTR NET1 RXNet OVRD N1 N0 RX IN 1400/2 AUX RELAY 7 RELAY 9 RS-485 TERM1 OUT RELAY 6 RELAY 7 NO RELAY 8 COM ON PRESENTATION OF A VALID CREDENTIAL TO THE CAB CARD READER, THE PAC 500 SENDS A COMMAND TO THE PAC 530 WHICH ENABLES THE CORRESPONDING DOOR BUTTONS. THE CARDHOLDER CAN THEN PRESS A BUTTON AND BE TAKEN TO THEIR FLOOR SELECTION. COM LIGHTING RELAY ON TERM2 RX TX ACCESS AND ALARM SERVER (PAC 500) TX RX CTS 0V DTR RS-232 CAB CARD READER ACCESS CONTROLLER (PAC 512) CONTROLLERS AND OPTIONS 7S-530 PAC 530 Output Controller (DIN-Rail Mount) 7S-DIN4X 7S-DIN6X 7S-PSU3A 7S-PSU7A Metal, lockable DIN-Rail Enclosure (20.47 in x 19.69 in. x 3.74 in.) accommodates 4 devices, UL Listed Metal, lockable DIN-Rail Enclosure (27.56 in. x 19.69 in. x 3.74 in.) accommodates 6 devices, UL Listed 12 or 24 VDC 3 A power supply with built-in charger for sealed lead acid or gel type batteries (DIN-Rail Mount) 12 or 24 VDC 7.2 A power supply with built-in charger for sealed lead acid or gel type batteries (DIN-Rail Mount) SPECIFICATIONS Primary Power Input Power: Communication Ports Outputs Inputs Input Control Points Tamper and Door Override: Power Fail Monitors (MSTAT): Status LEDs Wiring Requirements Mechanical Dimensions: Weight: Environmental Temperature: Humidity: Approvals: Warranty The PAC 530 is for use in low voltage, power limited, class 2 circuits only 10.5VDC @ 60mA to 28VDC @ 30mA RS-485 Ten 2-Amp Relay Outputs, configurable as latched, momentary, toggling or pulsing Two 8-Amp Relay Outputs, configurable as latched, momentary, toggling or pulsing 2 programmable supervised or non-supervised contacts Software configurable as N/O (normally open), N/C (normally closed) and two, three and four state sensor configuration Programmable as supervised or unsupervised circuits, dedicated Unsupervised, dedicated RS-485, Input Status, Output, System Status RS-485: CAT5 or CAT 6 up to 3000ft or 22AWG cable up to 500ft total cable H: 7.3" W: 5.1" D: 5.1" 14oz. nominal Operating: 14F to 130F Storage: -13F to 176F 0 to 85% RHNC ETL certified for UL 294. CE-marked and ROHS compliant 5-Year Limited Warranty © Copyright 2015, Stanley Security Solutions, Inc. All Rights Reserved. The information contained herein is subject to change without notice. Stanley shall not be liable for technical or editorial errors or omissions contained herein. Stanley, PAC, Stanley PAC, One-Touch are registered trademarks of Stanley Security Solutions, Inc. Readykey is a registered trademark of Stanley Security Solutions, Inc in the European Union, UK and Australia and of Bosch Security Inc. in the USA. All other trademarks are the property of their owners. Rev. AJM5/15 Visit us at... LIFT