Transcript
ACE-3000 Family
ACE-3402 Cellular Backhaul Aggregation Unit
• Dedicated station clock port • • • FEATURES
• ATM over Packet
• Carrier-class multiservice
access gateway, providing link aggregation over ATM and packet-switched networks (Ethernet, MPLS, IP) • ATM capabilities: ATM switching, including shaping and scheduling Up to 1024 ATM VPCs and VCCs UNI and NNI VP support Inverse multiplexing over ATM (IMA) 1.0 and 1.1 ATM OAM for end-to-end diagnostic control • Channelized STM-1/OC-3 capabilities: Up to 63 VC-12 channels for SDH Up to 84 VT1.5 channels for SONET
• TDM over ATM capabilities: CES as specified in the MFA's AF-VTOA-0078.00 Up to 8 bundles per VC-12/VT1.5
•
•
• •
capabilities: 1:1 and N:1 VP/VC mode Multiple cells per frame Up to 512 pseudowire connections TDM over Packet capabilities: CESoPSN for structured TDM traffic SAToP for unstructured TDM traffic Overcomes Ethernet network impairments via: Configurable jitter buffer Packet reordering Compensation for lost packets Configurable priority for pseudowire traffic, using VLAN, EXP bits or ToS/DSCP High accuracy clock mechanism: Reference and loopback timing over ATM Unicast clock distribution for up to 256 remote peers Multicast clock distribution (IP)
•
•
•
•
for an external timing reference Pseudowire connectivity verification ATM/TDM pseudowire alarm forwarding Advanced redundancy and protection options: APS (Automatic Protection Switching) on STM-1/OC-3 ports Dual power supply Multiple internal fans Full system redundancy Pluggable optical interface modules, including: STM-1/OC-3c ATM UNI Channelized STM-1/OC-3 Gigabit Ethernet Modular hot-swappable architecture for replacing the power supplies, fan tray or optical cards and modules in the field, while maintaining service continuity Inband and out-of-band management access using: ASCII terminal Telnet ConfiguRAD, RAD's Web-based management application RADview-Lite, RAD's SNMP-based management access system 2U high, fully modular unit with total front access architecture to simplify maintenance
ACE-3000 Family
ACE-3402 Cellular Backhaul Aggregation Unit DESCRIPTION • ACE-3402 delivers TDM and
ATM-based virtual containers in a channelized STM-1/OC-3 over ATM STM-1/OC-3c or packet-switched networks (PSNs), such as Ethernet, MPLS or IP.
• As a multiservice aggregation unit, ACE-3402 aggregates and optimizes multiple traffic types in 2G and 3G cellular backhaul applications.
ATM TRAFFIC
• The unit supports up to 1024
ATM connections with full UNI VPI and VCI ranges.
• Using ACE-3402, operators can
assign each virtual connection (VC) or virtual path (VP) to a service class, define the QoS parameters and shape the ATM egress traffic accordingly. This assures QoS in delay-sensitive applications.
• ACE-3402 provides traffic
scheduling according to CBR, VBR, UBR and UBR+.
• Rate limiting can be applied to each STM-1/OC-3c port.
• Inverse multiplexing over ATM
• The encapsulation of TDM traffic
ATM over PACKET
CHANNELIZED STM-1/OC-3
• ACE-3402 utilizes up to
• When equipped with channelized
(IMA) version 1.0 and 1.1 is supported.
512 pseudowire connections to emulate 3G ATM services over packet-switched networks .
• The following encapsulation
methods are supported according to draft-ietf-pwe3-atm-encap: 1:1 VC/VP – Each VCC/VPC is mapped to a single pseudowire (PW) connection N:1 VC/VP – Several VCs or VPs can be encapsulated to a single PW connection.
• ACE-3402 allows single or
multiple cells to be encapsulated per frame.
TDM over PACKET
• ACE-3402 allows 2G cellular traffic to be carried over packet-switched networks.
• To compensate for the jitter
caused by the packet-switched network, each TDM stream has a jitter buffer of up to 32 milliseconds.
APPLICATIONS
Figure 1. Hybrid Backhaul Solution
complies with ietf-pwe3-satop and ietf-pwe3-cesopsn requirements.
STM-1/OC-3 modules, ACE-3402 allows up to 63 VC-12 circuits (SDH) or up to 84 VT1.5 (SONET) circuits to be transmitted over a single STM-1/OC-3 UNI uplink or over a packet-switched network uplink.
• Each VC-12 or VT1.5 circuit can be channelized in UNI, CES or IMA mode.
• ACE-3402 allows CES bundles to
be transported over VC-12/VT1.5 traffic, with up to 8 bundles per port or 128/300 bundles in total.
QUALITY of SERVICE (QoS)
• Over packet-switched networks,
QoS is provided according to the network type: L2 network – outgoing pseudowire packets are assigned a dedicated VLAN ID according to 802.1Q and marked for priority using 802.1p bits MPLS network – outgoing pseudowire packets are assigned to a specific MPLS tunnel and marked for priority using EXP bits
IP network – outgoing pseudowire packets are marked for priority using ToS or DSCP bits. SYSTEM TIMING
• ACE-3402 provides a high
accuracy clock and flexible timing modes. The following transmit timing modes are supported for its STM-1/OC-3c interfaces: Loopback – derived from the receive clock of the current interface Reference – derived from the receive clock of the dedicated station clock port or any of the STM-1/OC-3c UNI or channelized STM-1/OC-3 ports.
• Over the packet-switched
network, ACE-3402 supports two timing options: Unicast clock distribution – the master clock is distributed with a dedicated stream towards up to 256 remote devices Multicast clock distribution – The master clock is distributed towards the PSN using a single IP multicast clock stream (IGMPv2 host).
STM-1/OC-3c/OC-3 INTERFACE
MANAGEMENT
• ACE-3402 features up to two
• ACE-3402 can be managed using
STM-1/OC-3c UNI interfaces, and up to two channelized STM-1/OC-3 interfaces: The STM-1/OC-3c UNI interface performs physical layer and ATM mapping into STM-1/OC-3c according to ITU I.432. The SDH or SONET operation mode is user-selectable. The channelized STM-1/OC-3 interface provides 63 VC-12 or 84 VT1.5 channels. Each channel can be set to ATM UNI/IMA or TDM mode.
• Automatic Protection Switching (APS) is supported by both interface types, to ensure a fail-safe, continuous operation.
GIGABIT ETHERNET INTERFACE
• ACE-3402 includes one
Gigabit Ethernet interface module, which supports fiber optic Small Form-Factor Pluggable (SFP) transceivers. Electrical 1000BaseT interface is also supported. • The Gigabit Ethernet interface is used for uplink connection and inband management access.
• The unit supports standard IP
different access methods, via: Dedicated RS-232 or 10/100BaseT ports Dedicated ATM VC defined on an STM-1/OC-3c ATM port Gigabit Ethernet uplink port (inband management). • The unit can be managed by and report to up to 16 different managers simultaneously. This enables viewing the network status from different locations.
• The following applications can be
used for management: Menu-driven terminal utility via an ASCII terminal connection Telnet via an IP-based connection ConfiguRAD, Web-based element management tool via an IP-based connection RADview-Lite, RAD’s SNMP-based management access system.
• Software upgrades and
configuration files can be downloaded/uploaded to/from ACE-3402 via TFTP or XMODEM.
features, such as ICMP (ping), ARP, next hop and default gateway.
Figure 2. 3G Backhaul over SDH/SONET Network
ACE-3000 Family
ACE-3402 Cellular Backhaul Aggregation Unit OAM and DIAGNOSTICS
• Comprehensive monitoring and
diagnostic capabilities include: Pseudowire connectivity check External and internal physical loopbacks on STM-1/OC-3c ports Cell test towards the ATM connections.
• For ATM cross-connects (XCs),
OAM is supported according to ITU I.610 requirements: F4 and F5 OAM support Configurable OAM mode per connection point Segment/intermediate mode for user connections and end-to-end mode for the management connection AIS and RDI cell detection and generation upon physical layer and ATM layer failures CC cell generation and LOC state detection per VP/VC Loopback location ID and configurable loopback source ID per device.
• The connectivity status of
pseudowire connections is verified periodically by ACE-3402 using a VCCV-BFD according to the draft-ietf-bfd-base requirements. If a failure is detected, a notification is sent to both the remote peer and the ATM/TDM connection of the specific PW. This allows complete monitoring over the PSN pseudowires in real-time.
• ATM or TDM alarms are
forwarded over the packet-switched network to the management station. This includes the mapping of: Packet-switched network alarms to ATM/TDM alarms ATM/TDM alarms over the PSN to the remote CE Physical failures of ATM/TDM ports, over the packet-switched network towards both the local CE and the remote CE.
• Performance monitoring is
• ACE-3402 collects statistics per
physical port and per VCC for 15-minute intervals. Statistics for the last 6 hours are stored in the device and can be retrieved at the network management station.
• For diagnostics purposes,
ACE-3402 maintains a cyclic event log file that stores up to 4096 time-stamped events.
MODULAR ARCHITECHTURE
• The modular architecture of
ACE-3402 allows hot-swappable modules to be replaced in the field while maintaining uninterrupted service. The unit is also fully accessible from the front panel.
• The unit's full hardware
redundancy features (fans, power supplies, modules) ensure a fail-safe, continuous operation, making ACE-3402 ideal for carriers and service providers.
provided by Ethernet and IP-layer network condition statistics, such as packet sequence errors (loss or misorder) and packet delay variation (jitter), which are monitored and stored by the device.
Figure 3. Emulated ATM/TDM Services over a Packet-Switched Network (PSN)
ACE-3000 Family
ACE-3402 Cellular Backhaul Aggregation Unit SPECIFICATIONS STM-1/OC-3c/OC-3 INTERFACE
ETHERNET CONTROL PORT
• Type
• Data Rate
100BaseTx, full-duplex • Compliance IEEE 802.3 • Connector RJ-45
• Operation Mode
TERMINAL CONTROL PORT
• Number of Ports
Up to 3 (field-replaceable modules) 155 Mbps
SDH or SONET UNI
• Compliance
Physical layer and ATM mapping into STM-1/OC-3 according to I.432 Automatic protection switching (APS) according to G.841 Annex B
• Jitter Performance
Output: according to G.825 Tolerance: according to G.823 Transfer: according to G.783
• Fiber Optic Interface Type
1310 nm – multimode, single mode or single mode long haul
• Fiber Optic Connector SC
GIGABIT ETHERNET INTERFACE
• Number of Ports
1 (field-replaceable module)
• Data Rate
1000 Mbps
• Compliance
IEEE 802.3z, 802.1Q, 802.1p
• Max. Frame Size 1600 bytes
• Operation Mode Full duplex
• Connector
Small Form-Factor Pluggable (SFP), fiber optic RJ-45, electrical
Note: Fiber optic Gigabit Ethernet modules require SFP transceivers that are fitted into the empty cage. For technical specifications and ordering information, refer to the SFP Transceivers data sheet.
• Type
RS-232/V.24 (DCE) • Data Rate 9.6, 19.2, 38.4, 57.6 or 115.2 kbps, user-configurable • Connector RJ-45 (adapter cable is supplied) STATION CLOCK INTERFACE
• Type
E1, balanced E1, unbalanced (via an adapter cable) T1 • Impedance Balanced E1: 120Ω Unbalanced E1: 75Ω (via an adapter cable) T1: 100Ω • Connector RJ-45 GENERAL
• Fan Tray
Field-replaceable, two independent cooling fans
• Power
Two hot-swappable AC or DC power supplies: AC: 100 to 240 VAC, 47–63 Hz DC: -48 VDC, nominal Note: AC and DC power supplies cannot be installed together in the same unit.
• Power Consumption 80W max
• Physical
Height: 87.4 mm (3.4 in / 2U) Width: 440.0 mm (17.3 in) Depth: 250.0 mm (9.0 in) Weight: 8.0 kg (17.6 lb)
• Environment
Temperature: Operating: 0°–50°C (32°–122°F) Storage: -20°–70°C (-4°–158°F) Humidity: Up to 90%, non-condensing
ACE-3000 Family
ACE-3402 Cellular Backhaul Aggregation Unit ORDERING ACE-3402/# Cellular Backhaul Aggregation Unit # Specify power supply type and redundancy: AC for single 100 to 240 VAC DC for single -48 VDC ACR for dual 100 to 240 VAC DCR for dual -48 VDC ACE-MC/*/~ ACE-3402 main card * Specify main card type: 155 for STM-1/OC-3 to GbE 155-CH for channelized STM-1/OC-3 to ATM STM-1/OC-3c with redundancy ~ Specify the required software license pack: Leave empty for ATM network functionality PACK1 for both ATM and packet-switched network functionality
SUPPLIED ACCESSORIES AC power cord or a DC power connection kit (if a DC-powered unit is ordered) RM-36 Hardware kit for mounting one ACE-3402 unit into a 19-inch rack CBL-RJ45/D9/F/STR RJ-45 to DB-9 control port adapter cable OPTIONAL ACCESSORIES CBL-RJ45/2BNC/E1 Interface adapter for converting a balanced E1 RJ-45 station clock connector to a pair of BNC unbalanced coaxial connectors (if unbalanced E1 station clock source is used) ACE-FTC/ACE-3402 Fan tray card (for replacement)
ACE-IF-155/^/& ACE-3402 ATM interface module ^ Specify fiber type: 13L for single mode, 1310 nm 13LH for SM, 1310 nm, long haul 13M for multimode, 1310 nm & Specify SC for SC connector type ACE-IF-GbE/@ ACE-3402 GbE interface module @ Specify port type: SFP for SFP cage (empty) UTP for 1000BaseT, electrical Note: Fiber optic Gigabit Ethernet modules require SFP transceivers that are fitted into the empty cage. For technical specifications and ordering information, refer to the SFP Transceivers data sheet, available on RAD's Web site.
www.rad.com International Headquarters 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel: 972-3-6458181 Fax: 972-3-6498250 Email:
[email protected] North America Headquarters 900 Corporate Drive Mahwah, NJ 07430, USA Tel: (201) 529-1100 Toll free: 1-800 444-7234 Fax: (201) 529-5777 Email:
[email protected] 367-102-10/06
© 1998–2006 RAD Data Communications Ltd. All other trademarks are the property of their respective holders.
Specifications are subject to change without prior notice.