EVO / DGP Programming ACM24D-EI00 TM ACM24D 4-Wire Access Control Module V1.0 When used on an EVO/DGP system, the ACM24 appears in WinLoad as two ACM12 modules. Serial Numbers Example: ACM24D = 3500556A ACM12 #1 = 3500556A ACM12 #2 = 3500556B (plus 1 number / letter) Locate Mode • • For Imperial panels, a Module Locate can be started or stopped using BabyWare software or by pushing the module’s LOC button. When a Module Locate is initiated, a flashing occurs of the module’s LEDs (BUS RX and TX flash at 1Hz) as well as the module’s representation in BabyWare. For DGP/EVO panels, a Module Locate can be initiated using section [4002] (EVO) or [952] (DGP-48 / DGP-848). To end a Module Locate, press the LOC button. Detachable Terminals Instructions Pry with screwdriver if necessary. PARADOX.COM Printed in Canada - 01/2009 The ACM24D Access Control Module can control two doors and can support REX devices, readers, locking devices and door contacts. Door contacts that are connected to the ACM24D are programmed using BabyWare software and can be assigned to zones in the Imperial system. Door Labels Space is provided to label each door. Imperial V32 EVO48, EVO192 DGP-848, DGP-NE96, EVO96 Installation Fuse - not used Figure 1: DIN Rail Mounting The ACM24D is a standard 35mm DIN rail module. Using the supplied DIN rail, 35mm the ACM24D can DIN rail be mounted in any location. Release Alternatively, it clip can be mounted in a standard DIN rail enclosure. To attach the module, align the top of the DIN rail as shown in Figure 1 and apply pressure to the module until it clicks into place. To remove the ACM24D from a DIN rail, pull the release clip and remove the module. Door LED Feedback To facilitate installation and servicing, the ACM24D terminals can be detached from the module. Wires can be labeled using the supplied tie wraps. Communication LED Feedback Door contacts connected to the system follow the control panel’s EOL definition. When EOL is enabled and door contacts are not used, place a 1kΩ resistor across the CT and C input terminals. If EOL is disabled, use a jumper. If the REX device is not used, place a jumper across the RX and C terminals. Stand-Alone Mode The ACM24D stores all access codes and cards in memory. If panel communication is lost, the ACM24D will continue to function normally. Events will be stored in memory. When communication is restored, events are automatically uploaded to the panel. Upgrading the Firmware Imperial The firmware of the ACM24D can be in-field upgraded through the V32’s RS485 ACCESS port using BabyWare. EVO/DGP The ACM24D firmware can be upgraded through WinLoad using the CV4USB RS-485/RS-232 Converter. Refer to the firmware upgrade instructions found at: paradox.com - Software WinLoad - Firmware Upgrade Instructions. DOOR1 and DOOR2 manual control buttons display door status and can override door programming. Manually unlocked doors remain unlocked for the minimum period programmed in BabyWare. Colour Condition green on red on Door unlocked Door locked Reader LED Feedback red flash red on green on off Reader auxiliary power failure Reader is missing Readers OK No reader programmed for this door Bus RX TX off off red green - flash off off red off red red flash red flash blue blue flash green off green - flash --off green - flash OK (panel communication in progress) off OK (no data RX/TX) off Short on GRN or YEL Communication failure / Too many modules on green Multibus green Multibus lines reversed (Green / Yellow) off Bus power too low green - flash Locate mode --Communication with V32 panel / Multibus mode off Firmware upgrade in progress Condition Power LED Feedback LED Colour Condition AC green green CHRG green (less than 4 sec.) AC or DC power is supplied Battery is low / charging Battery test . Transformer Sharing Connect to other modules compatible with transformer sharing. Transformer Modules can share a central AC transformer (16 to 24VAC) throughout the system. Ensure that the total power output of the transformer is respected. 16 / 24 Vac ACM24D 16 / 24 Vac ACM24D Readers Each ACM24D on a V32 can be assigned with up to 4 readers / 2 per door (EVO/DGP - 2 readers / 1 per door). The ACM24D supports R910 (V2.0 or higher) and/or R915 (any version) 4-wire card readers (up to 500mA). Readers 3 and 4 are optional and can be used as passback or SAS readers (one man trap, two-door access). Readers are assigned to the ACM24D in BabyWare (Imperial) or WinLoad/keypad assignment (EVO/DGP). Reader LED Orange slow flash = reader start up / too many readers on module Orange fast flash = reader not assigned Red on = reader is assigned to a door Connecting an External Trigger The external negative trigger can also be activated using a push button. When the push button is pressed, the door will unlock. The PGM or push button must ground the negative trigger. Energy Saving Feature When door locks are activated, voltage increases*. When the activation period expires*, the ACM24D will go into power saving mode and voltage will be reduced*. This feature is only available when using internal power (J2 on). * These settings are configurable with BabyWare software. REX Devices Door 1 Door 2 1 3 2 4 Optional external trigger Contact 1 kΩ** Input Power ~ ~ 16 - 24Vac Use a 16-24VAC (50/60 Hz) transformer with minimum 75VA. as shown in the connection diagram. Do not use switch-controlled outlets to power the transformer. It is possible for modules to share a central AC supply (16 to 24 VAC) throughout the system. Power supply or - + 16 - 36Vdc * Power supply Fail secure latch (N.O.) V32 control panel (RS485 ACCESS) Jumper Settings (J2) G R1 T1 RG TP PHONE LINE C 1 2 3 4 C 5 6 7 8 C ZONES 2-WIRE SMOKE BELL 13.8 Vdc AUX 700 mA MAX. 1 2 3 4 COM NC NO BELL PGM PGM 5 100mA 5A 16 / 24 Vac Remove J2 jumper before supplying external power. USB 2.0 PORT USB POWER BATTERY TBL USB RX/TX RS485 RX/TX ETHERNET MULTIBUS RED BLK GRN YEL ETHERNET 10/100 Mbps V32 RS485 ACCESS A+ B- BATTERY When the J2 jumper is ON, internal power is fed to COM of both relays (up to 2A at 12V). If using external power, remove the J2 jumper and supply power to the COM input (see below). COM Jumper Internal Power Supply To COM of relays TM External Power * + 12Vdc Power Supply To power the module’s door lock relay during a power failure, connect a 12Vdc (minimum capacity of 7Ah) rechargeable acid/lead or gel cell backup battery as shown in the connection diagram. Apply AC power before connecting the battery. Use supplied cable. If using custom wiring, add a fuse near the battery. Battery charge current: 350mA/500mA (configurable in BabyWare). The V32’s RS485 bus must be supplied with 12Vdc power. Technical Specifications 16-24Vac / 16-36Vdc Transformer Sharing compatible Power Input Rating: 75VA / 50W Current Consumption: min. 127mA max. 183mA Aux. Readers: 12Vdc, 500mA max. Aux. Locks: 6-12Vdc, 3.1A (internal) Battery: 12Vdc, 7Ah 2 x form C relay rated at 3.5A per door / 28Vdc, No. of Outputs: N.O. / N.C. No. of Zones: 4 (Door Contact & REX device - 2 per door) No. of Inputs: 2 (Negative Trigger - 1 per door) Operating 0ºC to 50ºC (32ºF to 122ºF) temperature: Software: BabyWare, WinLoad V4.6 Power Input Voltage: 24Vac Latch 24Vac Latch Battery Backup Battery PS27D Power supply - * J2 OFF = External power ~ 24Vac ~ Power supply J2 * 1N4007 Diode Connect the cathode to + voltage Anode Connect anode to - voltage Do not use a diode with AC power Cathode ** Follows control panels EOL definition Warranty For complete warranty information on this product please refer to the Limited Warranty Statement found on the website www.paradox.com/terms. Your use of the Paradox product signifies your acceptance of all warranty terms and conditions. Paradox Imperial, Mama, Paradox Mama and BabyWare are trademarks or registered trademarks of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries. Mark X is a registered trademark of Koninklijke Philips Electronics N.V For the latest information on products approvals, such as UL and CE, please visit www.paradox.com. © 2008 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111, 5119069, 5077549 and RE39406 and other pending patents may apply. Canadian and international patents may also apply.