Lockmod Series 1500 & Power Supply Modification advantage: You supply the lock and ACSI supplies the modification. The 1500s feature concealed modifications to standard architectural locking devices, allowing you to remotely control and/or monitor your building openings. Most manufacturers have locking hardware suitable for modification which allows you to maintain uniform trim throughout the building. Please consult the lock section guide located on the price list when selecting a specific device for modification. Contact ACSI for assistance with your special requirements. All manufacturers: Arrow, Baldwin, Best, Corbin, Dominion, Falcon, General, Lockwood, Monarch, Russwin, Sargent, Schlage, Von Duprin, Yale, and more. Lockmode functions: A choice of two U.L.-listed control modes and four patented monitoring options are available. When energized, the FAIL SAFE control mode operates as a storeroom function (latch bolt by trim inside and key outside, outside trim rigid, auxiliary latch deadbolts latch bolt) and, when de-energized, it operates as a passage set (latch bolt by trim either side). The FAIL SECURE control mode operates as a passage set when energized and a storeroom function then de-energized. A special LATCH RETRACTION modification is available on selected locking devices. Some may require special door preparation. Four types of monitoring may be used alone or in combination. Monitoring may also be used in conjunction with control functions. AUTHORIZED EGRESS generates an alarm shunt signal when the inside trim is operated. AUTHORIZED PASSAGE generates an alarm shunt signal when either inside or outside trim is operated. SECURITY MONITORING can provide either a closed circuit (CLS) or an open circuit (OLS), when the lock is in the secure condition (auxiliary latch depressed and solenoid in lock position). 1406 ACSI power supplies are designed to operate exit devices equipped with ACSI Series 1550 Electric Latch Retraction. Features: • UL listed • Provides power and control electronics for up to two ACSI ` 1550 Electric Latch Retraction Exit Devices • Select from independent control of single exit devices from separate inputs (one or two single doors) or sequential operatio of two exit devices from a single input (pair of doors) • Automatic door operator interface • Fire alarm interface 19
• Field adjustable latch retraction time delay • 24VDC, 12VDC constant voltage outputs (250 mA each) East – Pennsylvania
Midwest – Missouri
Southwest – Texas
800-233-4210
800-211-4607
866-693-6903
800-722-4210
Fax 800-854-4146
Fax 800-211-4608
Fax 866-693-6904
Fax 800-248-3620
www.topnotchinc.com
West – Nevada
[email protected]
Electric Hinges/Pivots 1100 Series ACSI 1100 Series Electric Hinges/Pivots are designed for doors that require concealed low voltage current transfer, concealed electric monitoring, or concealed low voltage current transfer with monitoring. ACSI 1100 Series products are UL Listed and carry a full one-year warranty.
Features • UL Listed. • Provide current transfer to electrified mortise or cylindrical locks, exit devices with electric latch retraction, electric strikes (pairs of doors), and locks with monitoring or request to exit switches. • Rated for 3.5 amp continuous and 16 amp pulse. • Available in Hager, Stanley, McKinney, Bommer, Rixson, Ives, and more. • Standard weight or heavy weight models. • Steel, brass, or stainless steel hinges. • Available in five knuckle and three knuckle hinges. • All architectural finishes in sizes 4 x 4 through 6 x 6.
Electrical Specifications • Concealed electric through-wire: 50 volts AC/DC @ 3.5 amps continuous, 16 amps pulse (maximum pulsewidth: 400 msec., 10 sec minimum off time between pluses). • Concealed electric monitor: 30 VDC @ .5 amps.
Model
Hinge Modification Description
1104
Concealed electric through-wire (4 wire) • Electric hinge must be placed in the center position only. • ACSI requires NON-NRP hinges for modification. Hinge pin is not field removable after modification. • ACSI part no. 302-03-03 mortar guard is required for all application with grout-filled frames. Failure to install mortar guard with void the electric hinge warranty.
20
Note:
East – Pennsylvania
Midwest – Missouri
Southwest – Texas
800-233-4210
800-211-4607
866-693-6903
800-722-4210
Fax 800-854-4146
Fax 800-211-4608
Fax 866-693-6904
Fax 800-248-3620
www.topnotchinc.com
West – Nevada
[email protected]
Series 1500 Electric Lock Modifications How to Order 4. LOCKING
1. LOCK TYPE (Select type of lock to be modified). Model M C MU
Model 1 2
Description Mortise Lock Cylindrical Lock Unit Lock
5. LOCK PART NO. Distributors supply ACSI with mortise, cylindrical or unit locks for modification. Please supply the lock manufacturer’s part number.
2. MODIFICATION NUMBER (Select type of modification required). Model 1510 1520 1550
Description Standard control locks outside (secure side) trim. Locks both sides — Mortise locks only.
Description Fail Safe Control Fail Secure Control Latch Retraction
Example: L9070, 8237, 8708, D80, 3357, etc.
6. OPERATING VOLTAGE Model
Note: Consult factory for 1550 modifications — Special door prep required.
24 VDC 24 VAC/DC 12 VDC
3. OPTIONS Model AE
12 VAC/DC
Description Authorized Egress (Request to Exit)
Note: Mortise locks can be supplied with pneumatic control. Consult factory.
ACSI Authorized Egress is a SPDT switch which monitors the activation of the INSIDE trim. The AE switch can be used to:
7. QUICK CONNECT CABLE Model QC
• Shunt a door alarm to allow egress. • Signal a control console when the trim is activated. • Activate a door alarm. • Control an electromagnetic lock for egress. LM
Description Quick Connect Cable • QC4 - 22AWG 2 conductor 6' quick-connect cable with two-position connector. Allows for ease of installation in transfer of power from the lock to the electrice hinge.
Latch Bolt Monitor
• Latch bolt monitoring is a SPDT switch which monitors the full extension of the main latch. SM
Security Monitoring
• The ACSI SM option monitors, in series, solenoid status (locked or unlocked) and latch status (deadlatch position). Note: Leave #3 blank if no options are required. 1
2
3
4
5
6
7
8
Lock type
Modification Number
Options
Locking
Lock Part No.
Operating Voltage
Handing
1510 1520 1550
AE LM SM
1 2
Full Part Number
24 VDC 24 VAC/DC 12 VDC
Quick Connect Cable QC
1510
AE
1
L9070 (Schlage)
24 VDC
RH LH RHR RH
East – Pennsylvania
Midwest – Missouri
Southwest – Texas
800-233-4210
800-211-4607
866-693-6903
800-722-4210
Fax 800-854-4146
Fax 800-211-4608
Fax 866-693-6904
Fax 800-248-3620
www.topnotchinc.com
West – Nevada
[email protected]
21
M C MU EXAMPLE: M
22
Note:
East – Pennsylvania
Midwest – Missouri
Southwest – Texas
800-233-4210
800-211-4607
866-693-6903
800-722-4210
Fax 800-854-4146
Fax 800-211-4608
Fax 866-693-6904
Fax 800-248-3620
www.topnotchinc.com
West – Nevada
[email protected]