Preview only show first 10 pages with watermark. For full document please download

Activboard System Shelf / Lockable Shelf Installation And User Guide

   EMBED


Share

Transcript

x1 x1 x1 x1 x2 x1 x2 x2 x1 ActivBoard System Shelf / Lockable Shelf Installation and User Guide For further support visit www.prometheankb.com For further information about the ActivBoard System visit www.prometheanworld.com TP1818 / 04 50kg/110lbs I II ActivBoard 95” ActivBoard 87” ActivBoard 78” 460mm 50kg/110lbs III IV www.prometheanworld.com V www.prometheankb.com GETTING STARTED 6. Lift the ActivBoard off the stand. • The installation work should be performed by a qualified installer. Attempting to install the product without relevant experience is done so at your own risk. • Ensure sufficient space to work around the ActivBoard System, including somewhere to put the ActivBoard whilst the Shelf is installed. • Take care when lifting and moving equipment. • Two people will be required to remove the ActivBoard and to replace it once the brackets are fitted. • The images used in this Guide refer to installation onto an ActivBoard Mobile System. If your System is wall-mounted you will not have the base shown in the picture, but the installation instructions remain the same. • Check you have all of the contents. INSTALLING THE ACTIVBOARD SYSTEM SHELF / LOCKABLE SHELF The Shelf can be fitted to either side of the stand. A maximum of two Shelves can be installed- one on either side- on the stand. Consider the room layout and the user’s personal preference when deciding which side to fit the Shelf. 1. Confirm if the shelf will be installed on the left or right of the System. 2. Slide the shelf on to the tube, ensuring the plastic end caps are behind the mounting bracket so they are not visible from the front of the system. 3. Tighten the thumb screw to ensure the shelf does not slip during assembly. 4. Attach the second bracket by hand, pushing the tube firmly into the hole on the bracket. DO NOT use a hammer. LOCKABLE SHELF: The tube is supplied separately from the brackets. 1. The tube must be inserted from the top of the shelf (Fig 2). III 1. Disconnect power to the System. Fig 1 3. Unplug cables at the back of the ActivBoard (Fig 1). 4. Depending on the set-up of the ActivBoard System, there may be additional cables on the ActivBoard to disconnect. 5. Slide back the safety retainer brackets on the back of the System to allow the ActivBoard to be removed. 1 II 2. Attach the brackets firmly by hand, with a push fit. Ensure the brackets are orientated appropriately for the shelf to be installed on the correct side of the stand. DO NOT use a hammer. I 2. For the Mobile System ensure the two front wheels are locked. 7. You will now have access to the stand frame, where the Shelf will be fitted. 1. Insert the brackets into the stand frame. Be careful not to disturb the cables attached to the motor switch or connectivity panel. IV 1. Fix the brackets in place using the two screws and washers supplied, using the hole that corresponds with the size of the ActivBoard. If you are unsure of the size of your ActivBoard, check the product code label on the left hand side of the board. 2 USER INSTRUCTIONS ABVX78XXX = 78 Adjusting the height of the shelf: ABVX87XXX = 87 ABVX95XXX = 95 2. Ensure brackets are firmly in place. 3. If you are fitting two Shelves, repeat II to IV on the other side of the stand. Adjusting the height of the lockable shelf: To raise the shelf• lift using 2 hands. V 2 1. Replace the ActivBoard on to the stand mounting brackets. Ensuring the upper ActivBoard brackets sit over the upper brackets on the frame. The bottom of the ActivBoard should rest on the lower brackets (Fig 3). 1 ! Fig 3 IMPORTANT Fig 4 THE SAFETY RETAINER BRACKETS MUST BE REPOSITIONED OVER THE ACTIVBOARD BRACKETS (Fig 4). THIS IS DONE BY SLIDING THE SAFETY RETAINER BRACKETS TOWARDS THE ACTIVBOARD. ENSURE THE BRACKETS ARE FIRMLY FITTED OVER THE BOARD BRACKETS, SO THAT THE ACTIVBOARD CANNOT BE LIFTED OFF THE STAND. 2. Reconnect the ActivBoard cables. 3. Reconnect power to the ActivBoard System. 3 • Loosen the thumb screw beneath the shelf (Fig 4). • Move the shelf to the desired height. • Retighten the thumb screw. ENSURE the thumb screw is tightened before using the shelf. 1 To lower the shelf• Lifting the shelf slightly, push in the orange button at the back of the shelf (Fig 5- 1). • Keeping the button depressed, lower the shelf to the desired height and release the button (Fig 5- 2). 2 USER GUIDELINES • DO NOT lean, or place heavy items on the shelf. The maximum load is 15kg. • DO NOT place drinks on the shelf. • LOCKABLE SHELF- Take care when opening and closing the lid. • LOCKABLE SHELF- DO NOT drop the lid on the lockable shelf. When used with the ActivBoard Mobile System: • Promethean recommends the wheels are locked. • When moving the ActivBoard Mobile System, use the orange handles on the back of the frame, do not pull or push on the shelf or brackets. 4