Preview only show first 10 pages with watermark. For full document please download

Acttg4p7sfls3rwe - Schneider Electric

   EMBED


Share

Transcript

ACTTG4P7SFLS3RWE Product datasheet Characteristics Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications Category7, 10G F/FTP Cable 305m White, LSZH Main Range of product Actassi Product or component type Copper cable Colour tint White Complementary Type of cable 4 pair cables Cable shielding type F/FTP Communication network category 7 Flame retardance LSZH Return loss 18.9 dB, at 150 MHz 17.3 dB, at 300 MHz 17.3 dB, at 600 MHz 23 dB, at 4 MHz 25 dB, at 10 MHz 25 dB, at 16 MHz 25 dB, at 20 MHz 24.3 dB, at 25 MHz 23.6 dB, at 31.25 MHz 21.5 dB, at 62.5 MHz 20.1 dB, at 100 MHz 24.5 dB, at 8 MHz 18 dB, at 200 MHz 17.3 dB, at 250 MHz Attenuation 3.74 dB at 4 MHz, cable length 100 m 5.24 dB at 8 MHz, cable length 100 m 5.86 dB at 10 MHz, cable length 100 m 7.41 dB at 16 MHz, cable length 100 m 8.29 dB at 20 MHz, cable length 100 m 9.29 dB at 25 MHz, cable length 100 m 10.41 dB at 31.25 MHz, cable length 100 m 14.88 dB at 62.5 MHz, cable length 100 m 19.02 dB at 100 MHz, cable length 100 m 23.56 dB at 150 MHz, cable length 100 m 27.47 dB at 200 MHz, cable length 100 m 30.97 dB at 250 MHz, cable length 100 m 34.19 dB at 300 MHz, cable length 100 m Sep 23, 2017 1 50.1 dB at 600 MHz, cable length 100 m Power sum near-end crosstalk [PS NEXT] 75 dB at 4 MHz 75 dB at 8 MHz 75 dB at 10 MHz 75 dB at 16 MHz 75 dB at 20 MHz 75 dB at 25 MHz 75 dB at 31.25 MHz 72.5 dB at 62.5 MHz 69.4 dB at 100 MHz 66.8 dB at 150 MHz 64.9 dB at 200 MHz 63.4 dB at 250 MHz 62.2 dB at 300 MHz 57.7 dB at 600 MHz Power sum attenuation to alien crosstalk ratio far-end [PS AACR-F] 75 dB at 4 MHz 72.9 dB at 8 MHz 71 dB at 10 MHz 66.9 dB at 16 MHz 65 dB at 20 MHz 633 dB at 25 MHz 61.1 dB at 31.25 MHz 55.1 dB at 62.5 MHz 51 dB at 100 MHz 47.5 dB at 150 MHz 45 dB at 200 MHz 43 dB at 250 MHz 41.5 dB at 300 MHz 35.4 dB at 600 MHz Near end crosstalk [NEXT] 78 dB at 4 MHz 78 dB at 8 MHz 78 dB at 10 MHz 78 dB at 16 MHz 78 dB at 20 MHz 78 dB at 25 MHz 78 dB at 31.25 MHz 75.5 dB at 62.5 MHz 72.4 dB at 100 MHz 69.8 dB at 150 MHz 67.9 dB at 200 MHz 66.4 dB at 250 MHz 65.2 dB at 300 MHz 60.7 dB at 600 MHz Loop resistance 95 Ohm/km Wire insulation material PE Conductor material Solid bare copper AWG gauge AWG 23 Cable outer diameter 7.1 mm Cable length 305 m Cable weight 56 kg/km Environment Temperature resistance 75 °C Standards IEC 61156-5 ISO/IEC 11801 2