Transcript
AD380A and AD381A PCIe 2-Port Gigabit Ethernet Card Installation Guide
HP Part Number: 5991–5976 Published: June 2007
Legal Notices © Copyright 2007 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation. Intel and Itanium are registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Java is a U.S. trademark of Sun Microsystems, Inc. UNIX is a registered trademark of The Open Group.
Table of Contents About this document..........................................................................................................9 1 Hardware and software installation procedures......................................................11 Installing the hardware.........................................................................................................................11 Access the system card bay.............................................................................................................11 Install the card.................................................................................................................................11 Connect the card to the network.....................................................................................................12 Installing the software...........................................................................................................................14 Prepare for the Installation..............................................................................................................15 Open the Computer Management program...................................................................................15 Install the adapter driver.................................................................................................................15 Ping a host on the network..............................................................................................................16 Troubleshooting....................................................................................................................................16 Check the connection.......................................................................................................................17
2 Specifications and Regulatory Information................................................................19 Card Specifications...............................................................................................................................19 Cable specifications...............................................................................................................................20 AD380A (copper).............................................................................................................................20 AD381A (fiber)................................................................................................................................20 RJ-45 pinouts and crossover function (applies to AD380A only).........................................................20 10/100 pinouts using internal, straight-through crossover.............................................................20 10/100 pinouts using external crossover through twisted-pair media............................................21 Gigabit over copper pinouts using internal crossover....................................................................22 Gigabit over copper pinouts using external crossover through twisted pair media......................23 Regulatory compliance information.....................................................................................................24 Regulatory compliance identification numbers..............................................................................24 Federal Communications Commission notice................................................................................24 Class A equipment...........................................................................................................................24 Class B equipment...........................................................................................................................24 Declaration of conformity for products marked with the FCC logo, United States only...............25 Modifications...................................................................................................................................25 Canadian notice (Avis Canadien).........................................................................................................25 European Union regulatory notice.......................................................................................................25 Japanese notice......................................................................................................................................26 Korean Class A notice...........................................................................................................................27 Korean Class B notice............................................................................................................................27 BSMI notice...........................................................................................................................................27 Disposal of waste equipment by users in private households in the European Union.......................27 Electrostatic discharge..........................................................................................................................28 Preventing electrostatic discharge...................................................................................................28 Grounding methods to prevent electrostatic discharge..................................................................28
Table of Contents
3
4
List of Figures 1-1 1-2 1-3 1-4 1-5 1-6 2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8 2-9 2-10 2-11
Inserting the card...........................................................................................................................12 Connecting the AD380A (copper) card.........................................................................................13 Connecting the AD381A (fiber) card.............................................................................................14 Ipconfig command output ............................................................................................................16 Adapter error display in the taskbar.............................................................................................16 Adapter error display in the Network Connections window.......................................................17 10/100 pinouts using internal, straight-through crossover...........................................................21 10/100 pinouts using external crossover through twisted-pair media..........................................22 Gigabit over copper pinouts using internal crossover..................................................................23 Gigabit over copper pinouts using external crossover through twisted pair media....................24 Harmonized European standards product marking....................................................................26 Non-telecom and EU harmonized telecom products marking.....................................................26 Japanese product notice................................................................................................................26 Korean Class A notice...................................................................................................................27 Korean Class B notice....................................................................................................................27 BSMI notice....................................................................................................................................27 EU waste disposal marking...........................................................................................................27
5
6
List of Tables 2-1 2-2
AD380A and AD381A card specifications....................................................................................19 Operating distances for AD381A adapter.....................................................................................20
7
8
About this document The instructions in this document apply to the AD380A (copper) and AD381A (fiber) 2-Port GbE Ethernet cards for Windows™ and Linux systems. You can download the driver at: http://www.hp.com/support/itaniumservers
Audience This document is for those who install and configure network interface cards.
Organization This document is organized as follows: Chapter 1
Describes the steps to install and configure the AD380A and AD381A 2-Port GbE Ethernet card.
Chapter 2
Provides information about the physical and environmental specifications of the AD381A 2-Port GbE Ethernet card.
9
10
1 Hardware and software installation procedures The HP AD380A (copper) and AD381A (fiber) PCI Express Dual Port Gigabit Server Adapters are high-performance, low-profile PCI Express Ethernet adapters that deliver up to 1000 Mb/s Ethernet over twisted-pair copper cabling or optical fiber cabling. They have a fully integrated controller capable of auto-negotiating a link at 10, 100, or 1000 Mb/s. Network connections are made through two RJ-45 connectors (AD380A) or two duplex LC connectors (AD381A). LED indicators show the link speed and activity. These adapters are supported on selected HP Integrity servers. You can add or replace them in your system without shutting down or rebooting, using a process called Online Addition and Replacement (OLAR). However, they must be installed in a PCI Express slot. If your AD380A or AD381A card is factory installed, you do not need to perform the hardware and software installation steps described in this chapter. However, you need to configure the card's IP address and possibly set other parameters and options, such as those mentioned in the Network Card Configuration worksheet.
Installing the hardware The following instructions guide you through the hardware installation process. These instructions assume you are not using the OLAR process.
Access the system card bay To access the system card bay, complete the following steps: 1. 2.
If the system is running, issue the sync command. Then, shut down the system by executing the shutdown -h command. Enter Y to continue to the shutdown prompt. Wait for the system to shut down completely, and then power off the system by pressing the system off button. Ensure that the system is grounded, and unplug the server power cord. WARNING! You must turn off and unplug the power to the HP server before removing its cover. Failure to do so could inflict a dangerous shock to you and may damage the adapter or the server.
3. 4.
Open the system to gain access to the PCIe backplane. Select an unused PCIe slot and remove the slot cover.
Install the card To install the card, complete the following steps: 1.
Check the latest 1 Gb Ethernet support matrix to see the systems that support this card, how many cards are allowed per system, and if any software updates are needed. The support matrix is available in the “I/O Cards and Networking Software” section at: http://docs.hp.com
2.
Record the serial number and MAC address located on the card for future reference. CAUTION: Electrostatic discharge can damage electronic components. You must observe antistatic precautions and wear electrostatic discharge (ESD) straps before installing the card. Refer to the section about electrostatic discharge in Chapter 2 for more information.
3.
Grasp the card by its edges or faceplate with both hands. Insert the card into the slot and firmly, but gently, press the card in until it is fully seated (see Figure 1–1).
Installing the hardware
11
Figure 1-1 Inserting the card
4.
Secure the adapter bracket, replace the access panel, and plug in the system power cord.
Connect the card to the network To connect the card to the network, complete the following steps: 1.
Attach the network cable (or cables) to the card, ensuring that the tab on each plug clicks into position, indicating proper seating. • For AD380A adapters (copper), the cabling must be Cat 5 UTP or better with RJ-45 connectors (see Figure 1–2). NOTE: The AD380A adapter can use existing UTP CAT5 cable to deliver Gigabit Ethernet over copper, according to the IEEE 802.3ab specifications. For new installations, CAT5e (enhanced CAT5) cable is recommended. •
12
For AD381A adapters (fiber), the cabling can be either 62.5 micron or 50 micron multimode fiber optic (MMF) cable with LC connectors (see Figure 1–3). If the remote connection is type SC, you will need an LC-to-SC conversion cable.
Hardware and software installation procedures
Figure 1-2 Connecting the AD380A (copper) card
Installing the hardware
13
Figure 1-3 Connecting the AD381A (fiber) card
Refer to the tables in the next chapter for maximum operating distances. 2.
Attach the free end of the LAN cable (or cables) to any unused port on the Gigabit switch. Ensure that the switch is configured to support any new connections. If you are using Jumbo Ethernet frames, ensure that the following conditions exist: • All end stations on a given LAN have the same maximum transmission unit (MTU) setting. • Intermediate stations such as switch ports in your LAN have an MTU equal to or greater than the end station’s MTU.
3. 4.
Ensure that the power cable is connected to system. Power up the system.
NOTE:
To obtain updates for the adapter driver, check the HP Driver Support site:
http://www.hp.com/support/itaniumservers.
Installing the software HP Integrity servers automatically detect and configure PCI-compliant adapters when restarting. The adapter IRQ level is automatically set by the Extensible Firmware Interface (EFI) each time the server restarts. If configuration problems are encountered, see the HP Support site: http://support.hp.com/.
14
Hardware and software installation procedures
Prepare for the Installation After installing the adapter in the server and booting the system, you must install the correct driver. You can download the driver from the Web or get it from the HP SmartSetup media that came with the adapter. NOTE: When using the HP SmartSetup media, the Hardware Update Wizard finds the driver automatically. To download from the Web, complete the following steps: 1. 2. 3. 4. 5. 6. 7.
Go to http://www.hp.com/support/itaniumservers. Select one of the HP Integrity servers that supports this adapter (for example, rx2660). Click Download drivers and software. Click the link that describes the server operating system. Click Driver-NIC. Select the appropriate driver. Download the driver to the server or to another system with a floppy or DVD writer.
Open the Computer Management program Once the driver is available, open the Computer Management program by clicking Start > Programs > Administrative Tools > Computer Management. If the Programs menu displays Administrative Tools, skip this section and go to the next section and install the adapter driver using the Computer Management software. If the Programs menu does not display Administrative Tools, complete the following steps: 1. Right-click on the system taskbar. 2. Select Properties. 3. Click the Start Menu tab. 4. Click the Start menu radio button. 5. Click Customize. 6. Click the Advanced tab. 7. Select Display Administrative Tools as a Start Menu item. 8. Click Okay. 9. Click Okay again. 10. Click Start > Programs > Administrative Tools > Computer Management.
Install the adapter driver To install the adapter driver, complete the following steps: 1. 2. 3. 4. 5. 6. 7. 8.
In the left panel of the Computer Management window, under System Tools, click Device Manager. In the right panel of Computer Management, under Network Adapters, double-click the name of the adapter you just installed. Click the Driver tab. Click Update Driver..., and the Hardware Update Wizard displays. Select No, not this time when prompted to let Windows find the driver. Then click Next. Select Install the software automatically (Recommended) and click Next. Click Finish to close the Hardware Update Wizard. The driver is now installed and the device Properties page displays the new driver version.
Installing the software
15
Ping a host on the network Once the adapter is properly connected to the network, ensure that its IP addresses is consistent with your network by completing the following steps: 1. Click Start > Run to open the Run dialog box. 2. Type cmd in the Run dialog box and click OK to run the command. 3. At the prompt, type ipconfig and press Enter. This command displays all of the IP addresses, subnet masks, and default gateways configured for the server (see Figure 1–4). Figure 1-4 Ipconfig command output
4.
5.
Now use the ping command to verify adapter connectivity. Use the adapter's IP address (that was displayed as output from the ipconfig command in Step 3) as your input for the ping command. Once the adapter is pinged and indicates no problems, ping another host on the same network. If the server is within the same IP group and subnet mask as the target host and valid replies are not received, check the network parameters to ensure that the server IP address and subnet mask are correct.
Troubleshooting This section describes some of the methods you can use to solve problems you may have with the operation of your AD380A or AD381A adapter. During system startup, network interface cards (NICs) attempt to load the latest available drivers. If there is a problem after the system has booted and configured the adapters (and as long as Show Icon in notification area when connected is enabled in the Network Properties window), you may see the following display in the system taskbar: Figure 1-5 Adapter error display in the taskbar
16
Hardware and software installation procedures
IMPORTANT: This display indicates that the adapter is not connected to the network. Verify that the adapter is properly connected using the appropriate cable.
Check the connection In some cases, the operating system may not even display the network icon in the system taskbar. To verify network connections in this situation, complete the following steps: 1. Click Start > Settings > Control Panel. 2. Double-click Network Connections. 3. If an adapter is not connected to the network, a red X appears over its network icon in the Network Connections window (see Figure 1–6). Figure 1-6 Adapter error display in the Network Connections window
4.
Once again, verify that the adapter is properly connected using either Category 5 or better cable (for AD380A) or fiber optic cable (for AD381A). Once the adapter is connected to a viable network, the red X should go away.
Troubleshooting
17
18
2 Specifications and Regulatory Information This chapter provides an overview of the AD380A and AD381A 2-Port GbE Ethernet cards and lists their physical and environmental specifications.
Card Specifications Adapter specs for the AD380A and AD381A are as follows: Table 2-1 AD380A and AD381A card specifications Specification
Description
Network Controller Chipset
Intel® 82571EB Dual MAC/PHY
Bus Type
x4 PCI Express v1.0a
Bus Width
Four lane
Clock Speed
100 MHz
On-board Memory
96 KB
Data Transfer Method
Bus Master DMA
Boot ROM Support
Yes
Management Capabilities
WOL, PXE 2.2, ACPI 1.1a
Power Requirement
1280 mA @ 3.3 VDC max
Data Transmission Rate
AD380A (copper): 10 Full/10 Half, 100 Full/100 Half, 1000 Full AD381A (fiber): 1000 Full
Standards Supported
IEEE 802.3, IEEE 802.3u, IEEE802.3ab, IEEE 802.3z, IEEE 802.3x (flow control), IEEE 802.3ad (link aggregation), IEEE 802.1p (QoS), IEEE 802.1q (VLAN tagging)
Dimensions
12.95 cm x 6.86 cm [5.1 in x 2.7 in (L x W)] (without bracket)
Connectors and Distances
AD380A (copper): 10BASE-T: Category 3, 4, or 5 UTP, 100 M (328 ft) 100BASE-TX: CAT5 UTP, 100 M (328 ft) 1000BASE-TX: CAT5 UTP, 100 M (328 ft) AD381A (fiber): 1000Base-SX: Multimode fiber (62.5 or 50 Micron)
Interrupts Supported
Automatically configured
Temperature Range
Operating: 0°C to 55°C (32°F to 131°F) Storage: -30°C to 60°C (-22°F to 140°F)
Relative Humidity (noncondensing)
Operating: 20% to 75% Storage: 20% to 80%
Safety Compliance
UL Mark (US and Canada) CE Mark EN 60590 RoHS (European Union)
Card Specifications
19
Cable specifications AD380A (copper) The AD380A 2–Port GbE adapter can use existing UTP CAT5 (or better) cable to deliver Gigabit Ethernet over copper, according to the IEEE 802.3ab specifications. For new installations, CAT5e (enhanced CAT5) cable is recommended. Maximum distance for Gigabit over copper cable is 100 meters (328 feet). To connect to the network, the AD380A card requires the following cable for 1000Base-T transmission: • CAT5 UTP or better twisted-pair • 22-26 AWG, 100Ω @ 1 MHz • EIA/TIA 568a or EIA/TIA 568b
AD381A (fiber) The AD381A 2-Port GbE adapter can use existing multimode fiber cable to deliver Gigabit Ethernet over fiber, according to the IEEE 802.3z specifications. Maximum distances for Gigabit over fiber cable are up to 550 meters (1804 ft). To connect to the network, the AD381A 2-port GbE adapter uses a 1000Base-SX fiber transceiver with low-profile LC fiber connectors. The maximum distance specifications for this adapter are as follows: Table 2-2 Operating distances for AD381A adapter Mode
Size
Maximum Distance
Multimode
62.5/125 μm
220 meters
Multimode
50/125 μm
550 meters
RJ-45 pinouts and crossover function (applies to AD380A only) The Ethernet standard also specifies that each segment implement a crossover function to connect the transmitter of one device to the receiver of a device at the other end. The crossover function may be implemented internally at the hub or switch or externally through the twisted-pair media.
10/100 pinouts using internal, straight-through crossover If the crossover function is implemented internally, the port is labeled MDI-X (Medium Dependent Interface-Crossover). When an MDI-X port is connected to an MDI port, the twisted pair media should be wired straight-through using the physical pinouts indicated. Pin
Function
Color match
Function
Pin
1
TD+
Orange
TD+
1
2
TD–
Orange/White
TD–
2
3
RD+
Green
RD+
3
4
Blue/White
4
5
Blue
5
6
20
RD–
Green/White
RD–
6
7
Brown
7
8
Brown/White
8
Specifications and Regulatory Information
Figure 2-1 10/100 pinouts using internal, straight-through crossover
10/100 pinouts using external crossover through twisted-pair media When the crossover function is not provided within the hub or switch, you must implement the crossover through the twisted-pair media using the physical pinouts indicated here. Pin
Function
Color match
Function
Pin
1
TD+
Orange
RD+
3
2
TD–
Orange/White
RD–
6
3
RD+
Green
TD+
1
TD–
2
4
Blue/White
5
Blue
6
RD–
Green/White
7
Brown
8
Brown/White
RJ-45 pinouts and crossover function (applies to AD380A only)
21
Figure 2-2 10/100 pinouts using external crossover through twisted-pair media
Gigabit over copper pinouts using internal crossover Unlike connections in which the crossover function is implemented internally at the hub or switch, the AD380A provides its own automatic crossover function. This means you can wire twisted-pair media straight-through for adapter-to-hub, adapter-to-switch, or adapter-to-adapter connections using the pinouts indicated.
22
Pin
Function
Color match
Function
Pin
1
BI_DA+
Orange
BI_DA+
1
2
BI_DA–
Orange/White
BI_DA–
2
3
BI_DB+
Green
BI_DB+
3
4
BI_DC+
Blue/White
BI_DC+
4
5
BI_DC–
Blue
BI_DC–
5
6
BI_DB–
Green/White
BI_DB–
6
7
BI_DD+
Brown
BI_DD+
7
8
BI_DD–
Brown/White
BI_DD–
8
Specifications and Regulatory Information
Figure 2-3 Gigabit over copper pinouts using internal crossover
Gigabit over copper pinouts using external crossover through twisted pair media When a crossover function is not provided by the adapter, hub or switch, you must implement it through the twisted-pair media using the physical pinouts indicated here. Pin
Function
Color match
Function
Pin
1
BI_DA+
Orange
BI_DB+
3
2
BI_DA–
Orange/White
BI_DB–
6
3
BI_DB+
Green
BI_DA+
1
4
BI_DC+
Blue/White
BI_DD+
7
5
BI_DC–
Blue
BI_DD–
8
6
BI_DB–
Green/White
BI_DA–
2
7
BI_DD+
Brown
BI_DC+
4
8
BI_DD–
Brown/White
BI_DC–
5
RJ-45 pinouts and crossover function (applies to AD380A only)
23
Figure 2-4 Gigabit over copper pinouts using external crossover through twisted pair media
Regulatory compliance information Regulatory compliance identification numbers For the purpose of regulatory compliance certifications and identification, this product has been assigned a unique regulatory model number. The regulatory model number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to this regulatory model number. The regulatory model number is not the marketing name or model number of the product.
Federal Communications Commission notice Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio Frequency (RF) emission limits to provide an interference-free radio frequency spectrum. Many electronic devices, including computers, generate RF energy incidental to their intended function and are, therefore, covered by these rules. These rules place computers and related peripheral devices into two classes, A and B, depending upon their intended installation. Class A devices are those that may reasonably be expected to be installed in a business or commercial environment. Class B devices are those that may reasonably be expected to be installed in a residential environment (for example, personal computers). The FCC requires devices in both classes to bear a label
Class A equipment This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense.
Class B equipment This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and 24
Specifications and Regulatory Information
can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit that is different from that to which the receiver is connected. • Consult the dealer or an experienced radio or television technician for help.
Declaration of conformity for products marked with the FCC logo, United States only This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions regarding this product, contact us by mail or telephone: • Hewlett-Packard Company P. O. Box 692000, Mail Stop 530113 Houston, Texas 77269-2000 • •
1-800-HP-INVENT (1-800-474-6836). (For continuous quality improvement, calls may be recorded.) Hewlett-Packard Company P. O. Box 692000, Mail Stop 510101 Houston, Texas 77269-2000
•
To identify this product, refer to the part, series, or model number found on the product.
Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user’s authority to operate the equipment.
Canadian notice (Avis Canadien) Class A This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Class B Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
European Union regulatory notice This product complies with the following EU Directives: • Low Voltage Directive 73/23/EEC • EMC Directive 89/336/EEC Compliance with these directives implies conformity to applicable harmonized European standards (European Norms) which are listed on the EU Declaration of Conformity issued by Hewlett-Packard for this product or product family. Canadian notice (Avis Canadien)
25
This compliance is indicated by the following conformity marking placed on the product: Figure 2-5 Harmonized European standards product marking
This marking is valid for non-telecom products and EU harmonized telecom products (e.g. Bluetooth). Figure 2-6 Non-telecom and EU harmonized telecom products marking
This marking is valid for EU non-harmonized Telecom products. * Notified body number (used only if applicable—refer to the product label)
Japanese notice Figure 2-7 Japanese product notice
26
Specifications and Regulatory Information
Korean Class A notice Figure 2-8 Korean Class A notice
Korean Class B notice Figure 2-9 Korean Class B notice
BSMI notice Figure 2-10 BSMI notice
Disposal of waste equipment by users in private households in the European Union Figure 2-11 EU waste disposal marking
Korean Class A notice
27
This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
Electrostatic discharge The following sections provide information on preventing electrostatic discharges and grounding methods to prevent electrostatic discharge.
Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device. To prevent electrostatic damage: • Avoid hand contact by transporting and storing products in static-safe containers. • Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations. • Place parts on a grounded surface before removing them from their containers. • Avoid touching pins, leads, or circuitry. • Always be properly grounded when touching a static-sensitive component or assembly.
Grounding methods to prevent electrostatic discharge Several methods are used for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts: • Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megaohm ±10 percent resistance in the ground cords. To provide proper ground, wear the strap snug against the skin. • Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats. • Use conductive field service tools. • Avoid touching pins, leads, or circuitry. • Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part. For more information on static electricity or assistance with product installation, contact an authorized reseller.
28
Specifications and Regulatory Information
29
*5991–5976* Printed in the US