Transcript
Instruction manual
_____________________________________ Dehumidifier
AD 810
_____________________________________
valid: 10-2010
page 1 of 14
Index 1.
Illustration 1.1. View from the rear AD 810
3
2.
General advice
3
3.
Mode of functioning
4
4.
Safety
5
5.
Installation and transport
5
6.
Operation 6.1. Electrical connection 6.2. Putting into operation 6.3. Operation panel 6.4. Hygrostat control 6.5. Condensate removal 6.6. Automatic defrosting
6 6 7 7-8 8-9 9
7.
Operating conditions
9 - 10
8.
Technical data
10 - 11
9.
Service and maintenance
11
10. Trouble shooting
12 - 13
11. Disposal
13
12. Manufacturer´s declaration
14
page 2 of 14
1.Illustration 1.1 View from the rear AD 810 Air inlet with air filter
Filter holder Condensate hose connector for connector nipple or for hose 12 x 2 mm Button for manual pump out (to empty the pump completely before moving the device) Main cable approx. 4,5 m, with plug 4 pcs. Cators, fixable (D= 100 mm)
2.General advice You have bought an air dryer made by AERIAL thus deciding for a proven quality product "Made in Germany". If there are any questions, you will find some advice in this manual how to eliminate such difficulties as quickly as possible. ATTENTION: Immediately after receipt, you should check your air dryer for transport damage! In the case of damage, you should inform the forwarding agent, parcel service, post office etc. accordingly upon receipt, and make a note of it on the forwarding documents! If a transport damage should be noticed after unpacking the equipment, please contact immediately your respective seller or specialized dealer. Before putting your air dryer into operation for the very first time, these instructions for operation should be studied very thoroughly. Thus, you can make sure that this appliance will operate perfectly for a long period of time saving yourselves unnecessary repairs and expenses. In the case of malfunction disconnect your appliance and ensure that it is not connected again by taking the mains plug out of the socket. page 3 of 14
Please, keep the device wrapping in order to be able to send the device safe for guarantee repair. In order to save space you open simply the adhesive tape with a knife and you fold the carton.
3.Mode of functioning The AD-air dryer is built particularly for air drying in closed rooms. That dehumidifier can prevent the formation of condensation, eliminate too high air humidity and hold a specific air humidity constant. The time which the dryer requires in order to achieve a specific humidity depends essentially on the environmental conditions. The attainable humidity value is equally dependent on the environmental conditions. The AD-dehumidifier works according to the condensation principle with heat recovery. The fan (shown indicatively below) suck the moist air through a cool register (evaporator). The air becomes so far chilled under the point of condensation here, that the moist air condense as water and flows through the pump, out into a sump. The chilled and dried air is warmed up at the condenser again. Through the heat pump effect, the outlet air is some degrees warmer than the sucked room air. Useful energy can conducted up to 3-fold of the electrical power consumption. The absolute moisture of air is lowered continuously by the continuous circulation of the room air through the device. The surplus moisture is removed safely and efficiently. 1 – wet room air 2 – dry air 3 – evaporator 4 – condenser 5 – built in pump 6 – compressor 7 - fan
page 4 of 14
4. Safety The condensation dryers AD 810 are furnished with protective devices. The devices were subjected to a safety examination. Dangers threaten in the case of operating error or abuse - for the user. - for the machine and other real values. - for the efficient work of the machine. All persons who have to do with the installation, service and maintenance of the devices must be qualified correspondingly and consider this operating manual precisely. Using as directed The condensation dryers are intended for the drying of air with atmospheric pressure. Risk by accessory Hoses for condensate removal and air filters must be fit expertly and must not take the protective devices of the condensation dryers out of operation. The control elements must always remain freely amenable. Authorized users The service of the condensation dryers AD 550 / AD 650 may only be carried out by persons, that were instructed from the operator. The user is responsible in the field of action third parties compared to. Responsibilities for different activities on the device must of course be determined and kept. Unclear competences are a safety hazard. The operator must make the operating instruction available for the user and make sure that the user did understand the manual.
5. Installation and transport The dehumidifiers of series AD 810 are conceived for the mobile or stationary employment. During the setting up and transportation of the dehumidifier, the following items are to be considered: Ø That dehumidifier must be installed so that the air can circulate without obstruction through him. The air filter and also the outlet grille of the front wall must not be covered. The open space before the outlet grille, the air filter and the ventilation slot near the operation panel must at least conduct 1 meter. Ø Before every local alternation of the device, empty the condensate pump (see Pt. 6.5 – condensate removal), switch off the device at the on/off-switch and pull the power plug from the socket. Ø The air dryer must be installed on a plane base only. It must be secured against rolling off! Ø That dehumidifier can be transported upright or laid flat! The upright transportation is to be preferred if possible. Ø The appliance must be used exclusively for air drying. ATTENTION: Do never pull or move the device at the power cable page 5 of 14
6. Operation 6.1 electrical connection Before connecting the air dryer, the following items must be checked: Ø Does the mains voltage coincide with the voltage of the appliance? Ø Adequate fusing of socket and supply system? Ø Has a residual-current-operated circuitbreaker (r.c.c.b) been installed? Ø If a cable drum is used: has it been unwound completely? Ø Is the appliance connector suitable for the building socket? Ø Is the socket provided with an earth connection? ATTENTION: Before putting the air dryer into operation, the technical data of the appliance should be compared to the conditions prevailing in the room of installation!
6.2 Putting into operation ATTENTION: Before putting the air dryer into operation, the instruction manual should be studied carefully. Thus, damages by a false or inappropriate operation as well as by inadequate environmental conditions can be avoided. For using the air dryer, please proceed as follows: Ø After having been transported, the air dryer should rest for about 15 min. During this period of time, the oil inside the refrigerating system, that was foamed during transport will return into the compressor. We recommend this procedure since it extends the service life of the compressor. Ø Put the plug of the device into a suitable socket. Ø Connect a hose to the hose connector at the back of the device and guide this hose into a sump. Fix the hose and make sure that the condensate is guided away safely. (Pt. 6.5) Ø Switch on the unit by actuating the ON-OFF-switch. Ø Set the required humidity value at the hygrostat (please refer in this respect to 'Hygrostat Control' - 6.4). Ø If the existing humidity is higher than the set value, the air dryer will start to operate. If the existing humidity is lower than the set value, the air dryer will not start to operate.
page 6 of 14
6.3 Operation panel On-/Off-switch
Hygrostat (Pkt. 6.4)
neon: Check pump (Pt. 6.5) Ventilation slot for room air flow for hygrostat (do not cover!!!)
Operation time counter
6.4 Hygrostat control The air dryers of the AD-series dispose of a hygrostat for setting the required humidity value. This hygrostat is located in the operation panel of the unit. It makes that the air dryer cuts in as soon as the ambient humidity exceeds the preset value. If the humidity value falls below the set value, the hygrostat will switch off the unit. The hygrostat is placed in the operation panel laterally at the unit. Pos. 0
= Unit is switched off
Pos. 1
= Continues operation
80-100% = The dehumidifier switches off when a humidity of approx. 80 - 95% r.h. has achieved. And switches on again when humidity is higher than 80-95%. 60 - 80% = The dehumidifier switches off when a humidity of approx. 60 - 80% r.h. has achieved. And switches on again when humidity is higher than 60-80%. 40 - 60% = The dehumidifier switches off when a humidity of approx. 40 - 60% r.h. has achieved. And switches on again when humidity is higher than 40-60%. 20 - 40% = The dehumidifier switches off when a humidity of approx. 20 - 40% r.h. has achieved. And switches on again when humidity is higher than 20-40%.
page 7 of 14
The smooth setting option of the hygrostat makes a very convenient humidity control possible for you. If very precise values are requested, you should match the hygrostat with the information on a precise hygrometer. Please consider: Humidity values of a minimum of 40 % - 45 % r.h. can be achieved with a condensation dryer. An adsorption dryer is to be employed if lower values are required. For this purpose, ask your technical consultant. Optimal climate: For living rooms, environmental conditions of 20°-25°C and 50 - 60 % r.h. are recommended. For building drying, the hygrostat becomes turned at continues running (POS. I). In the case of the drying rooms with wood equipment (e.g. floors) or paintings, antiques and similar things should not be fallen below a humidity of 55%. Ask your technical consultant in the case of special applications. 6.5 Condensate removal The dehumidifier AD 810 is serially equipped with a built in condensate pump. The condensate pump is placed below the air filter, behind the back plate. In the back plate a connector and a button is placed. Afitting connection piece is included with the delivery.
a) Taster zum manuellen Abpumpen
b) Stecknippel zum Anschluss des Ablaufschlauches
Connection piece: At the hose connector you can connect a hose 12 x 2 mm directly. Alternative the hose can be connected at the connection piece (see following picture). That connection piece can be fixed and removed again at the hose connector very easy.
ATTENTION: Make sure that the condensate can always be handled safely. Fix the end of the hose in a sump!
page 8 of 14
Red button: The built in condensate pump works automatically during the drying process. It pumps out the condensate whenever it is necessary. For technical reason a small rest of water stays in the pump. If the device should be transported, we recommend to empty the pump completely. This is to make sure that no water runs out when you tilt the unit. To empty the condensate pumpe completely, push the red button until no more water flows through the hose. Neon red in the operation panel (Pt. 6.3) If the red neon in the operation panel lights up, the dryer has been switched off because there is a fault in the condensate pump. Check the pump! Attention: This fault switch off does not function if a hose has been disconnected or damaged. Check the internal hose connections regularly to make sure that no condensate water flows next to the unit. 6.6 Automatic defrosting During air drying, ice may form at the evaporator. The volume of ice depends on the ambient conditions prevailing in the room to be dried. The AD 810 is equipped with an automatic hot-gas defrosting. It ensures that, depending on the extent of ice formation, the appliance will be defrosted automatically according to the following principle: Ø A temperature sensor measures the condition existing in a critical area of the evaporator. Ø It transmits the signal for defrosting to the DryLogic-electronic. The DryLogic finds out if defrosting is necessary, and it will start defrost-mode on its own. Ø During defrosting the compressor works and the fan does not work When the ice is defrosted, the dehumidifier will start again with dehumidifying.
7. Operating conditions AD-condensation dryers are suitable for the effort on construction sites, in residential buildings, in swimming halls, in garages and storerooms. ADcondensation dryers work problem-free at the temperature range of +3 to +32°C and in the case of relative humidity from 40% to 95% r.h. . The use in rooms with higher temperatures leads to disadvantages at the compressor. The use in rooms with lower temperatures is ineffective and can lead to icing. Also the storage of the dehumidifier at inadmissible temperature conditions can lead to damages / problems while immediate switch-on. Therefore, make possible short time for adaptation for the device before switch-on.
page 9 of 14
ATTENTION: The appliance must not be used under the following conditions: Ø in rooms of potentially explosive atmosphere Ø in rooms of aggressive atmospheres, for example ammonia and wood acid Ø In rooms with water which shows a pH-value outside of 7,0 to 7,4. Remark: In The case of lower pH-value, corrosion occurs at all metals and damages occurs at mortar containing materials. In the case of higher pH-value, it comes to irritation of skin and eye mucous membrane and extreme lime deposits. Ø In rooms with salt or salty liquids. Salt content >1% (also sole baths). Ø In rooms of air treated with ozone Ø in rooms featuring a high concentration of solvents Ø in rooms of an extremely high ratio of dust. Ø Please consider also, that extremely air movings around the dryer can annoy or affect the function of the dryer as the air flow of the dryer can not flow as planned. In the case of doubtful operating conditions it is recommended to contact the Technical Department of Messrs. AERIAL or a specialized dealer. Using an AD-air dryer under inadequate operating conditions will entail that the warranty becomes null and void.
8.Technical data Among other things, many different components which are installed in the condensation dryer decide on the capacity of the device. Since these components can never be completely identical, in accordance to DIN EN 810 the capacity may deviate up to 5% of specified capacity. General: Operational range: Protection class: Voltage:
+3°C up to + 32°C / 40% r.h. up to 95% r.h. IP X4 230 V / 50 Hz
Type
AD 810
Air volume
cbm/h
1.300
Power consumption
Max. Watts
1.500
Noise level
dB(A)
60
refrigerant (filling charge see type plate) 30°C / 80% r.h
l/24h Watt
R407c 105,0 1.500
page 10 of 14
27°C / 60% r.h.
l/24h Watt
67,0 1.300
20°C / 60% r.h.
l/24h Watt
50,0 1.120
10°C / 70% r.h.
l/24h Watt
26,0 900
dimensions
mm
990 / 635 / 530
weight
kg
71
9. Service & Maintenance ATTENTION When performing any repair or maintenance, the general safety rules and provisions must be adhered to! In order to guarantee a troublefree function of the dryer the device should be cleaned regularly. The following procedure is recommended: Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø
Switch off the dryer Pull main cable from the socket Remove filter holder (see 1.1) Remove filter and clean or organize new one Remove cover (front/top-panel). Check pump, all hose connections and hoses Blow out device cautiously with compressed air. (wear protective goggles!) In this case, it might ensure that all components are cleaned. (Compressor, evaporator, condenser, ect.) mount cover (front/top-panel). Clean case with moist cloth. Do not use aggressive detergent Insert new or cleaned filter. Use only original AERIAL-filter for problemfree working. Insert filter holder Put plug into socket Switch on the dryer This cleaning is without fail regularly required! During construction site effort, after every effort or once a week!
page 11 of 14
10. Trouble shooting Assign that dehumidifier a putative defect on, please, first check the following points. If this should provide no relief, please contact your technical consultant. 1) The dehumidifier shows a bad or no drying capacity - The humidity is lower than 40% r.h. or the temperature in that room is lower than +3°C. The using of the dryer is uneconomical in the case of these conditions. It is recommended to disconnect the dryer. Tipp: Put the built-in hygrostat on an attainable value (e.g. approx. 50%r.F.), with it the dryer punctually may switch off. - The air filter is soiled. The dryer does not receive air sufficiently. Clean the filter and/or install a new one. A soiled air filter can in the long run lead to disadvantages at the dryer. Tipp: Control the filter regularly. Do only use original air filters! 2) The fan of the dehumidifier does not work, the compressor still turns. - The unit is in defrost mode. In this case the compressor still runs and the fan does not run. After some minutes, the unit will start with regular working 3) The complete dryer is out of operation. Fan and compressor does not run. - Is the dryer switched on? The On-/Off-switch must be in position `I´ and must light up. - Is the unit supplied with voltage? The On/Off-switch must light up in Pos. `I´. Check the main cable, an additional cable, the socket and the main fuse. - The humidity value adjusted at the hygrostat is achieved. The dryer will start again after exceeding the adjusted humidity. - There is a fault at the condensate pumpe. In that case the red neon in the operation panel (see Pt. 1.1) lights up. Check the pump and all cables. Let repair the unit by an expert. 4) Strong icing up at the evaporator. - Put the dryer into a room with min. +10°C room temperature and wait until complete ice is defrosted. Switch on the unit again (in that room with min. +10°C) and let work for approx 3 hours. If there is icing up again, please contact your dealer. Otherwise make sure that the unit is only been used in rooms with more than +3°C. Also the storage of the dehumidifier at inadmissible temperature conditions can lead to damages / problems while immediate switch-on. 5) The humidity adjusted at the hygrostat does not become achieved and/or the device does not switch off automatic.: - Is the hygrostat adjusted on a value lower than 40 – 45% r.h.? Humidity values with a minimum of 40 % - 45 % r.h. can be achieved with a condensation dryer. Adjust the hygrostat to a reachable value. - Is the unit with enough capacity for your application? The air changing, number of the persons in the room and open water surfaces decide on the humidity burden in the room. Let calculate the necessary capacity from your dealer - Is there a lot of water in the walls or the floor? In that case the dryer needs some time to remove that water and to achieve an acceptable humidity in that room.
page 12 of 14
ATTENTION The appliance must be repaired by trained and expert personnel only. In the case of interventions by unauthorized people, any and all warranty claims shall become null and void! If you have any questions regarding defects and malfunctions of AERIAL-air dryers we recommend get in touch with your supplier. The producer AERIAL GmbH you reach under 0049-40-526879-0 or www.aerial.de
11. Disposal Please do not dispose this unit with the domestic waste and please do not dispose this unit in the environment. We dispose this unit for you – free of charge and environment-friendly. Please contact us! Alternative your local waste management enterprise takes this unit for environment-friendly disposal.
page 13 of 14
12. Manufacturer´s declaration (EU-directive 98/37/EG) (EU-directive 2004/108/EG) (EU-directive 73/23/EWG) manufacturer:
AERIAL GmbH - Systeme zur Luftbehandlung Oststraße 128, D-22844 Norderstedt
Product description:
dehumidifier type AD 810
capacity:
105,0 l/day
The product described above is an ambient air dryer ready for connection. Related standards:
EN ISO 12100 EN 61 000
Safety of Machinery Electromagnetic Compatibility (EMC) Basic Specification "Emitted Interference" EN 60 335-2-40 Safety of electric appliances for domestic use and similar purposes
In the case of changings at the unit this manufacturer´s declaration becomes void. Norderstedt, 01.10.2010
sign / stamp
Karsten Meier – General Manager AERIAL GmbH Oststrasse 128 22844 Norderstedt DEUTSCHLAND Niederlassung Schweiz: AERIAL GmbH Täfernstrasse 22a 5405 Baden-Dättwil SCHWEIZ
page 14 of 14