AD8C311 1 Form A Solid State Relay DESCRIPTION The AD8C311 is a bi-directional, single-pole, single-throw, normally open multipurpose solid-state relay. It is designed to replace electromechanical relays in general purpose switching applications. The relay consists of an integrated circuit that drives two rugged source-to-source enhancement type DMOS transistors - optically coupled to a light emitting diode. The output MOS transistors are protected with free-wheeling diodes that can handle up to 5A of inrush current, making the relay ideal for switching lamps and highly inductive loads. FEATURES APPLICATIONS • High input-to-output isolation • Telecom switching • Low input control power consumption • Tip/Ring control • 200mA maximum continuous load current • PCMCIA modules • 10 ohms maximum on-resistance • Multiplexers • Long life/high reliability • Meter reading systems • Data acquisition • Medical equipment • Battery monitoring • Home/Safety security systems OPTIONS/SUFFIXES • -S Surface Mount Option • -TR Tape and Reel SCHEMATIC DIAGRAM MAXIMUM RATINGS PARAMETER UNIT MIN Storage Temperature °C -55 125 Operating Temperature °C -40 85 Continuous Input Current mA 40 Transient Input Current mA 400 Reverse Input Control Voltage V Output Power Dissipation TYP MAX 6 mW 500 APPROVALS rev 1.0 • BABT CERTIFICATE #608204: BS EN 60950, BS EN 41003, BS EN 60065 • CSA CERTIFICATE #LR111581-1 • UL FILE #E90096 Solid State Optronics, Inc. 1.888.377.4776 www.ssousa.com AD8C311 1 Form A Solid State Relay ELECTRICAL CHARACTERISTICS - 25° PARAMETER UNIT MIN TYP MAX 1.2 1.5 TEST CONDITIONS INPUT SPECIFICATIONS LED Forward Voltage V LED Reverse Voltage Turn-On Current Turn-Off Current mA If = 10mA V 6 12 Ir = 10uA mA 5 2.5 Io = 150mA 0.5 OUTPUT SPECIFICATIONS Blocking Voltage V Continuous Load Current mA On-Resistance Ω 400 Io = 10uA 200 If = 5mA 6 10 Io = 200mA µA 0.2 10 Vo = 400V Output Capacitance pF 25 50 Vo = 25V, f = 1.0MHz Offset Voltage mV 0.2 If = 5mA Leakage Current COUPLED SPECIFICATIONS Isolation Voltage -H Suffix Turn-On Time 2500 V 3750 T = 1 minute T = 1 minute ms 2 Turn-Off Time ms 0.2 Isolation Resistance GΩ Coupled Capacitance pF Contact Transient Ratio rev 1.0 V V/ 5 If = 5mA, Io = 200mA 0.5 If = 5mA, Io = 200mA 100 2 µs 2000 7000 dV = 50V Solid State Optronics, Inc. 1.888.377.4776 www.ssousa.com AD8C311 1 Form A Solid State Relay AD8C311 AD8C311 Typical Turn-On Time Distribution N = 100, Ambient Temperature = 25°C Typical Turn-Off Time Distribution N = 100, Ambient Temperature = 25°C 60 50 40 30 20 10 0 Device Count 0.8 1 1.2 1.4 1.6 1.8 2 60 50 40 30 20 10 0 2.2 0 0.04 0.08 0.12 0.16 0.2 0.24 0.28 Turn-On Tim e (m s) Turn-Off Tim e (m s) AD8C311 AD8C311 Typical On-Resistance Distribution N = 100, Ambient Temperature = 25°C Typical Leakage Current Distribution N = 100, Ambient Temperature = 25°C 80 Device Count 20 10 0 5.25 5.5 5.75 6 6.25 6.5 6.75 60 40 20 0 7 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 On-Resistance (ohm s) Leakage Current (uA) AD8C311 AD8C311 Typical Blocking Voltage Distribution N = 100, Ambient Temperature = 25°C 400 410 420 430 440 450 460 470 Blocking Voltage (V) rev 1.0 0 20 0 100 50 0 10 200 150 -2 0 20 250 -4 0 30 Load Current (mA) Device Count 40 Typical Load Current vs. Temperature 80 30 60 Device Count 40 40 Device Count PERFORMANCE DATA Tem perature (C) Solid State Optronics, Inc. 1.888.377.4776 www.ssousa.com AD8C311 1 Form A Solid State Relay MECHANICAL DIMENSIONS 8 PIN DUAL IN-LINE PACKAGE rev 1.0 8 PIN SURFACE MOUNT DEVICE END VIEW END VIEW TOP VIEW TOP VIEW BOTTOM VIEW/ BOARD PATTERN BOTTOM VIEW/ BOARD PATTERN Solid State Optronics, Inc. 1.888.377.4776 www.ssousa.com