AD8C311 1 Form A Solid State Relay
DESCRIPTION The AD8C311 is a bi-directional, single-pole, single-throw, normally open multipurpose solid-state relay. It is designed to replace electromechanical relays in general purpose switching applications. The relay consists of an integrated circuit that drives two rugged source-to-source enhancement type DMOS transistors - optically coupled to a light emitting diode. The output MOS transistors are protected with free-wheeling diodes that can handle up to 5A of inrush current, making the relay ideal for switching lamps and highly inductive loads.
FEATURES
APPLICATIONS
•
High input-to-output isolation
•
Telecom switching
•
Low input control power consumption
•
Tip/Ring control
•
200mA maximum continuous load current
•
PCMCIA modules
•
10 ohms maximum on-resistance
•
Multiplexers
•
Long life/high reliability
•
Meter reading systems
•
Data acquisition
•
Medical equipment
•
Battery monitoring
•
Home/Safety security systems
OPTIONS/SUFFIXES
•
-S
Surface Mount Option
•
-TR
Tape and Reel
SCHEMATIC DIAGRAM
MAXIMUM RATINGS PARAMETER
UNIT
MIN
Storage Temperature
°C
-55
125
Operating Temperature
°C
-40
85
Continuous Input Current
mA
40
Transient Input Current
mA
400
Reverse Input Control Voltage
V
Output Power Dissipation
TYP
MAX
6
mW
500
APPROVALS
rev 1.0
•
BABT CERTIFICATE #608204: BS EN 60950, BS EN 41003, BS EN 60065
•
CSA CERTIFICATE #LR111581-1
•
UL FILE #E90096
Solid State Optronics, Inc. 1.888.377.4776 www.ssousa.com
AD8C311 1 Form A Solid State Relay
ELECTRICAL CHARACTERISTICS - 25° PARAMETER
UNIT
MIN
TYP
MAX
1.2
1.5
TEST CONDITIONS
INPUT SPECIFICATIONS LED Forward Voltage
V
LED Reverse Voltage Turn-On Current Turn-Off Current
mA
If = 10mA
V
6
12
Ir = 10uA
mA
5
2.5
Io = 150mA
0.5
OUTPUT SPECIFICATIONS Blocking Voltage
V
Continuous Load Current
mA
On-Resistance
Ω
400
Io = 10uA 200
If = 5mA
6
10
Io = 200mA
µA
0.2
10
Vo = 400V
Output Capacitance
pF
25
50
Vo = 25V, f = 1.0MHz
Offset Voltage
mV
0.2
If = 5mA
Leakage Current
COUPLED SPECIFICATIONS Isolation Voltage -H Suffix Turn-On Time
2500
V
3750
T = 1 minute T = 1 minute
ms
2
Turn-Off Time
ms
0.2
Isolation Resistance
GΩ
Coupled Capacitance
pF
Contact Transient Ratio
rev 1.0
V
V/
5
If = 5mA, Io = 200mA
0.5
If = 5mA, Io = 200mA
100 2 µs
2000
7000
dV = 50V
Solid State Optronics, Inc. 1.888.377.4776 www.ssousa.com
AD8C311 1 Form A Solid State Relay
AD8C311
AD8C311
Typical Turn-On Time Distribution N = 100, Ambient Temperature = 25°C
Typical Turn-Off Time Distribution N = 100, Ambient Temperature = 25°C
60 50 40 30 20 10 0
Device Count 0.8
1
1.2
1.4
1.6
1.8
2
60 50 40 30 20 10 0
2.2
0
0.04 0.08 0.12 0.16 0.2 0.24 0.28
Turn-On Tim e (m s)
Turn-Off Tim e (m s)
AD8C311
AD8C311
Typical On-Resistance Distribution N = 100, Ambient Temperature = 25°C
Typical Leakage Current Distribution N = 100, Ambient Temperature = 25°C
80 Device Count
20 10 0 5.25 5.5 5.75
6
6.25 6.5 6.75
60 40 20 0
7
0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5
On-Resistance (ohm s)
Leakage Current (uA)
AD8C311
AD8C311
Typical Blocking Voltage Distribution N = 100, Ambient Temperature = 25°C
400 410 420 430 440 450 460 470 Blocking Voltage (V)
rev 1.0
0 20
0
100 50
0
10
200 150
-2 0
20
250
-4 0
30
Load Current (mA)
Device Count
40
Typical Load Current vs. Temperature
80
30
60
Device Count
40
40
Device Count
PERFORMANCE DATA
Tem perature (C)
Solid State Optronics, Inc. 1.888.377.4776 www.ssousa.com
AD8C311 1 Form A Solid State Relay
MECHANICAL DIMENSIONS 8 PIN DUAL IN-LINE PACKAGE
rev 1.0
8 PIN SURFACE MOUNT DEVICE
END VIEW
END VIEW
TOP VIEW
TOP VIEW
BOTTOM VIEW/ BOARD PATTERN
BOTTOM VIEW/ BOARD PATTERN
Solid State Optronics, Inc. 1.888.377.4776 www.ssousa.com