Adc-apc Integrated Cisco Data Center Solutions

   EMBED


Share

Transcript

ADC-APC Integrated Cisco Data Center Solutions Advanced Infrastructure Solution for Cisco Data Center 3.0 Ordering Guide The evolution of data centers is happening before our eyes. This is due to the increased demand for bandwidth and storage requirements, as well as, consolidation and facility usage due to energy costs. In addition, new technologies such as Storage Area Networks, Blade Servers, Fiber Channel over Ethernet and IP Convergence are driving much of the evolution. Data centers face many challenges including density, reliability, scalability and power consumption. The amount of power required for data centers has doubled in the past five years and is expected to continue to rise in the coming years. One simple way to reduce the power and cooling costs within a data center is to promote proper airflow. Strategies such as implementing hot aisles and proper cable management can go along way towards reducing these costs and creating a more energy efficient data center. ADC-APC® Alliance ADC, a global leader in copper and fiber connectivity and cable management infrastructure solutions, and APC®, an industry leader in critical power and cooling services, have teamed up to provide a complete solution that addresses high density connectivity and management needs, as well as, power and cooling solutions required by today’s complex data center environments. ADC-APC Integrated Data Center Solutions The two companies have collaborated to simplify the data center design decisions, ease the installation process of new equipment and ensure a more efficient and economical data center. The result is an integrated solution that provides superior cable management, scalability in dense environments and industry leading power and cooling options for today’s robust data center environments. Simply choose your active gear and let ADC and APC take care of the rest. Electrical distribution and industrial control • Power distribution • Cooling solutions Data Center Solutions with leading cable management improved airflow, and easy to remove power supply. • IT infrastructure management • Fiber and copper connectivity • EF&I services Benefits of the Integrated Data Center Solutions ADC-APC Integrated Cisco Data Center Solutions, TrueNet/NetShelter MDS 9513 System, TrueNet/ NetShelter MDS 9509 System, TrueNet/NetShelter Catalyst 6509 System offer in-cabinet solutions, for three leading Cisco switches. All three solutions offer the following features: • Best-in-class cable management for easy adds, moves and changes • Improved air-flow and energy efficiency within your data center • Ease of installation 9/09 • 107947AE  Integrated Cisco Data Center Solutions ADC-APC® Integrated Cisco Data Center Solutions www.adc.com • +1-952-938-8080 • 1-800-366-3891 1 ADC-APC Integrated Cisco Data Center Solutions The ADC-APC® Integrated Data Center Solutions offer answers to the problems of cooling, airflow and cable management within your data center. The primary goal of thermal management and power management in the data center is to maximize the performance, uptime and life expectancy of the active equipment used by your enterprise. This goal is accomplished by managing the cold air delivered to every piece of equipment such that the internal temperature of all equipment in the data center never exceeds the manufacturer’s maximum allowable operating temperature. Two easy and effective approaches are designing your data center with hot aisles and cold aisles and using products and solutions that maximize cable management and airflow around equipment. The hot and cold aisle arrangement provides the most efficient means for IT equipment in a data center with traditional front-to-back airflow. Equipment with side-to-side airflow, common with many large, data center switches, presents some additional cooling challenges within an enclosure. The typical solution for side-to-side airflow switches is to direct the air to essentially convert the equipment to intake and exhaust air from the front and rear of the enclosure. The APC-ADC solution offers side airflow ducts to direct the cool air at the front of the enclosure, directly and predictably to the intake at the side of the switch. The Side Airflow Duct Kit shown below, consists of two 2U ducts that act as diverters utilizing the existing fan power of the switch. A baffle is located on the back of the switch and ducts to mitigate exhaust air from recirculating back into the air intake. The exhaust air from the equipment then exits from the rear of the rack with no opportunity to return to the equipment air intake. Proper use of blanking panels in conjunction with the APC NetShelter enclosure restricts any hot air from entering into the cold aisle. This, in essence, allows the cooling pattern for side-to-side equipment to become frontto-back thereby integrating seamlessly with other equipment in enclosures. • 107947AE  Integrated Cisco Data Center Solutions Airflow and Cooling Management 9/09 AR7715X900 Side Airflow Duct Kit shown with Cisco 6500 series switch www.adc.com • +1-952-938-8080 • 1-800-366-3891 2 ADC-APC Integrated Cisco Data Center Solutions The ADC-APC Integrated Cisco Data Center Solutions have been design around three industry leading Cisco switches, the 9509, 9513, and 6509. Simply choose your active gear and let ADC and APC take care of the rest. Cisco MDS 9509 The Cisco 9509 Series provides industry-leading availability, scalability, security, and management. The Cisco MDS 9509 allows you to deploy high-performance storage-area networks (SANs) with lowest total cost of ownership. Cisco MDS 9509 Cisco MDS 9513 the Cisco MDS 9513 Multilayer Director elevates the standard for director-class switches. Providing industry-leading availability, scalability, security, and management, the Cisco MDS 9513 allows you to deploy high-performance SANs with an extremely low total cost of ownership. Cisco MDS 6509 The Cisco Catalyst 6500 Series of enhanced (E-Series) switches, includes a chassis with up to 1440 Gbps of system bandwidth capacity (80 Gbps/ slot), Cisco Catalyst 6500 E-Series chassis provide superior investment protection by supporting multiple generations of products on the same chassis, lowering the total cost of ownership. Cisco MDS 9513 Cisco MDS 6509 9/09 • 107947AE  Integrated Cisco Data Center Solutions Cisco Equipment Courtesy of Cisco Systems, Inc. Unauthorized use is not permitted. These materials have been reproduced by ADC with the permission of Cisco Systems Inc. COPYRIGHT © 2009 CISCO SYSTEMS, INC. ALL RIGHTS RESERVED. www.adc.com • +1-952-938-8080 • 1-800-366-3891 3 ADC-APC Integrated Cisco Data Center Solutions NetShelter® SX 42U 750 mm Wide x 1070 mm Deep Enclosure feature-rich rack enclosures with advanced cooling, power distribution, and cable management for server and networking applications in IT environments. APC’s NetShelter SX enclosures offer the most standard, out-of-the-box features to ease installation and speed deployment. The SX utilizes a single, flexible enclosure design to accommodate various networking and server applications. Seamless integration with APC InfraStruXure products such as power distribution, in-row cooling and uninterruptible power supplies provides the building blocks for any data center. Features • Cable Access Roof • Half-height side panels • Easy adjustable vertical mounting rails • Integrated Rear cable channels for toolless mounting of PDUs and cable managers • Leveling feet and castors • Wider for more cable management and improved rear access • Ventilated Perforated front and rear doors provide ample ventilation APC's NetShelter SX Enclosure and Power Supply TrueNet/NetShelter MDS 9513 System Enclosure, Cooling, and Power Components: Enclosure: AR3150 NetShelter SX Enclosure (42U x 750 mm W x 1070 mm D) Power Distribution Unit: (2) AP7864 Rack mount PDUs for Dual Cisco 6000W power supplies Cooling: AR7715X900 Side Airflow Duct Kit TrueNet/NetShelter MDS 9509 System Enclosure, Cooling, and Power Components: Enclosure: AR3150 NetShelter SX Enclosure (42U x 750 mm W x 1070 mm D) Power Distribution Unit: (2) AP7841 Rack mount PDUs for Dual Cisco 3000 W power supplies Cooling: AR7715X900 Side Airflow Duct Kit TrueNet/NetShelter Catalyst 6509 System Enclosure, Cooling, and Power Components: Enclosure: AR3150 NetShelter SX Enclosure (42U x 750 mm W x 1070 mm D) Power Distribution Unit: (2) AP7864 Rack mount PDUs for Dual Cisco 6000 W power supplies. For 8700W power supplies use (2) AP7868 Cooling: AR7715X900 Side Airflow Duct Kit 9/09 • 107947AE  Integrated Cisco Data Center Solutions APC Enclosure and Accessories Side Airflow Duct Kit Designed for optimal cooling for Cisco side-ventilating switches, the kit includes a top and bottom (2) U duct, (2) mounting zero U mounting brackets, rear isolation baffle, hardware, and an installation sheet. www.adc.com • +1-952-938-8080 • 1-800-366-3891 4 ADC-APC Integrated Cisco Data Center Solutions ADC’s TrueNet® Structured Cabling System is an end-to-end, integrated portfolio of high-performance copper and fiber cable, connectivity and cable management solutions. The following connectivity and cable management components are designed specifically for each of the TrueNet/NetShelter solutions. TrueNet/NetShelter MDS 9513 System Connectivity and Cable Management Components: (1) Rear Cable Manager (1) Vertical Slack Storage Panel (1) Storage Panel Vertical Cable Guide (1) Cross-through Trough (1) Horizontal Slack Storage Panel (2) 2 RU Blank Plate (4) TrueNet Fiber Panel (TFP) With New Cable Manager, 5 RU This kit does not include the patch cords, cassettes or adapters plates that go into the TrueNet Fiber Panels. TrueNet/NetShelter MDS 9509 System Connectivity and Cable Management Components: (1) Rear Cable Manager (1) Vertical Slack Storage Panel (1) Vertical Cable Guide (1) Cross Through Trough (1) Horizontal Slack Storage Panel (2) 2 RU Blank Plate (1) 5 RU Blank Plate (3) TrueNet Fiber Panel (TFP) With New Cable Manager, 5 RU TrueNet/NetShelter MDS 9513 System This kit does not include the patch cords, cassettes or adapters plates that go into the TrueNet Fiber Panels. TrueNet/NetShelter Catalyst 6509 System Connectivity and Cable Management Components: (2) Rear Cable Manager (7) Cable Ring (3) Fiber Bracket (1) Convoluted Tubing (1) Vertical Cable Guide (1) Crossover Trough (2) Horizontal Slack Storage Panel (2) 2 RU Blank Panel (7) Category 6 Patch Panel and Cable Bars ADC's 5 RU TrueNet Fiber Panel ADC's Category 6 Dynamic Angled Patch Panel This kit does not include the patch cords. 9/09 • 107947AE  Integrated Cisco Data Center Solutions ADC Connectivity and Cable Management www.adc.com • +1-952-938-8080 • 1-800-366-3891 5 ADC-APC Integrated Cisco Data Center Solutions Your network equipment can only perform as well as your cables. Cabling within the data center should be deployed with proper bend radius protection, well-defined cable routing paths, room to work on connectors and cables without affecting adjacent circuits or ports, and physical protection for equipment cables. Without proper management, problems can arise and lead to increased time required to decommission hardware and bring new hardware online or inefficiencies in the cooling of the data center. The ADC-APC Integrated Data Center Solutions take the guess work out of cable management with intuitive cable routing and the ease of using a single length of patch cord throughout. ADC-APC Integrated Data Center Solutions are designed for a speedy deployment. When installing a patch cord, first connect it to the active equipment, and then connect it to the patch panel, then route the patch cord appropriately through the cable guides. Refer to the diagrams below for illustrations on how to cable all three of the ADC-APC Integrated Data Center Solutions. How to Cable the TrueNet/NetShelter MDS 9513 System 9/09 • 107947AE  Integrated Cisco Data Center Solutions How to Cable the Solutions www.adc.com • +1-952-938-8080 • 1-800-366-3891 6 ADC-APC Integrated Cisco Data Center Solutions How to Cable the Solutions TrueNet/NetShelter Catalyst 6509 System 9/09 • 107947AE  Integrated Cisco Data Center Solutions How to Cable the TrueNet/NetShelter MDS 9509 System www.adc.com • +1-952-938-8080 • 1-800-366-3891 7 ADC-APC Integrated Cisco Data Center Solutions Below is the ordering information for the ADC-APC Integrated Cisco Data Center Solutions. Choose the connectivity and cable management solution that corresponds to the Cisco equipment selected. All three kits coordinate with the APC NetShelter SX 42U enclosure. For Cisco equipment, please order through the proper channels. Ordering Information Description Catalog Number Enclosure, Cooling, and Power – APC NetShelter SX, 42U x 750mm wide x 1070mm deep enclosure AR3150 Side Airflow Duct Kit for 6509, 9509, 9513 AR7715X900 Power Distribution Unit for MDS 9513 with 6000W PS AP7864 Power Distribution Unit for MDS 9509 with 3000W PS AP7841 Power Distribution Unit for Catalyst 6509 with 6000W PS AP7864 Power Distribution Unit for Catalyst 6509 with 8700W PS AP7868 Connectivity and Cable Management – ADC TrueNet MDS 9513 system connectivity and cable management kit ADCC9D1FT04 TrueNet MDS 9509 system connectivity and cable management kit ADCC991FT03 TrueNet catalyst 6509 system connectivity and cable management kit ADCC691C607 For APC sales support call 877-272-2722 For ADC sales support call 800-366-3891 9/09 • 107947AE  Integrated Cisco Data Center Solutions Integrated Solutions – Ordering Information www.adc.com • +1-952-938-8080 • 1-800-366-3891 8 ADC-APC Integrated Cisco Data Center Solutions The following items can be ordered separately to support the ADC-APC Integrated Cisco Data Center Solutions: Ordering Information Description Catalog Number TrueNet/NetShelter MDS 9513 and 9509 Systems Multimode Adapter only Packs; LC adapters with zirconia sleeve, aqua color, 12 adapters or 24 fiber ports per adapter pack Singlemode Adapter Packs; LC adapters with zirconia sleeve, blue color, 12 adapters or 24 fiber ports per adapter pack Angle LEFT adapter only pack TFP-24APLQ2 Angle RIGHT adapter only pack TFP-24APRQ2 Angle LEFT adapter only pack TFP-24APLQ5 Angle RIGHT adapter only pack TFP-24APRQ5 MPO Adapter Pack; Contains 6 MPO adapters, can be installed in either left or right position Length of ZipCord Fiber Patch Cords 50/125 multimode – 150 meters @ 10 Gigabit; LC-LC connectors Length of Patch Cord 2 mm zipcord 1.6 mm zipcord 50/125 multimode – 300 meters @ 10 Gigabit; LC-LC connectors 2 mm zipcord 1.6 mm zipcord Singlemode; LC-LC connectors TFP-72AP0MP 2 mm zipcord 1.7 mm zipcord Catalog Number 2 meters PAT-LM5EQ-002MPT 3 meters PAT-LM5EQ-003MPT 2 meters PAT-LM5EV-002MPT 3 meters PAT-LM5EV-003MPT 2 meters PAT-LM5UQ-002MPT 3 meters PAT-LM5UQ-003MPT 2 meters PAT-LM5UV-002MPT 3 meters PAT-LM5UV-003MPT 2 meters FPC2E-SDLC-2M 3 meters FPC2E-SDLC-3M 2 meters FPCTE-SDLC-S-2M 3 meters FPCTE-SDLC-S-3M TrueNet/NetShelter Catalyst 6509 System CopperTen Category 6A RJ45-RJ45 UTP patch cord 568B 568A Category 6 RJ45-RJ45 plug UTP PVC patch cord T568B T568A crossover 7 feet 6645-2-8X5-07 11 feet 6645-2-8X5-11 7 feet 6645-2-8X0-07 11 feet 6645-2-8X0-11 7 feet 6645-2-78X-07 11 feet 6645-2-78X-11 7 feet 6645-2-77X-07 11 feet 6645-2-77X-11 7 feet 6645-2-79X-07 11 feet 6645-2-79X-11 9/09 • 107947AE  Integrated Cisco Data Center Solutions Accessories – Ordering Information www.adc.com • +1-952-938-8080 • 1-800-366-3891 9 ADC-APC Integrated Cisco Data Center Solutions Website: www.adc.com From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080 Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website. ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101 Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer 107947AE  9/09  Revision  ©  2009  ADC Telecommunications, Inc.  All Rights Reserved