Preview only show first 10 pages with watermark. For full document please download

Adc0007- Adc Phase 8.4.1 Control Board Software Flowchart-rev 1-6

   EMBED


Share

Transcript

ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART ADC CATALOG #: ADC0007 DIRECTORY LOCATION: \\ADC_CAD\F\ELECTRICAL ENGINEERS\PHASE 8.4.1 DMC ADC\CONTROL BOARD SOFTWARE SPECIFICATIONS\CONTROL BOARD SOFTWARE FLOWCHARTS\ADC0007- ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART-REV 1.6.DOC PRINCIPAL AUTHOR(S): VERSION: DATE: Jose Morales 1.6 8/3/2004 9:10 AM Page 1 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 DOCUMENT REVISIONS Revision 1.0 1.1 Revised By J.M. J.M. Description of Revisions This document was created. • • • • • • • • • • • • • • • • Added section 1- DOCUMENT RELEASE PROCESS. Removed 6.8 controlled cool down flowchart Update 8.5 section title to HEAT CONTROL AND DIAGNOSTICS and update HEAT ONE BURNER and HEAT TWO BURNER to reflect name change. Removed 12.2 water valve output test flowchart changed terminology in the PROGRAM MODE flowchart from "currency location" to "vending parameter." Corrected flowchart table of contents to include SWITCHING CYCLE flowchart. Added TEST BOOTH FLOWCHART to 14.1. Updated table of contents to reflect new section numbers. corrected COIN READY MODE flowchart, bottom pocket applying power up credit function was out of sequence. Updated PROGRAM MODE and OPL READY MODE flowcharts to reflect exiting program mode with the key pad, when control is in opl mode and had entered program mode using the UP and STOP keys. Added 30 sec fault resetting to exhaust and axial probe faults. updated REVERSING and ROTATION SENSOR DIAGNOSTICS flowcharts to handle new reversing diagnostics. Also added new REVERSING ROTATION SENSOR DIAGNOSTIC routine. Updated CYCLE START UP, WRINKLE GUARD, and S.A.F.E./ F.S.S. ACTIVATED flowcharts to reflect "active drive" instead of "drive" due to new reversing rotation sensor diagnostic routine. added NON CATASTROPHIC FAULT ROUTINE and updated HEAT CONTROL AND DIAGNOSTICS, added HEAT OFF DIAGNOSTICS routine and updated HEAT ONE BURNER SYSTEM, HEAT TWO BURNER SYSTEM, FAULT ROUTINE, HEAT CONTROL DIAGNOSTIC, COOL DOWN, PAUSE MAIN DOOR, LINT DOOR AND SAIL SWITCH OPEN flowcharts to reflect new HEAT OFF DIAGNOSTIC routine. Updated HEAT ROUTINE to reference BURNER SETUP setting. Date Released To MEC 9/13/04 To MEC 10/12/04 Page 2 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART ADC ENGINEERING CONTROLS GROUP • • • • • • • • • • • • • • • • • • • • ADC CATALOG #: ADC0007 corrected terminology used to describe OPL-AUTO CYCLE flowchart. changed LOW VOLTAGE DIAGNOSTICS to POWER LOSS DIAGNOSTICS change S.A.F.E. SYSTEM to just S.A.F.E. and correct all occurances of SAFE to S.A.F.E. Removed ERROR ERROR for Registration Routine flowchart added CLEARING ESCROW Routine and added routine call to READY MODE ROUTINE. corrected grammar and spelling errors throughout flow chart, all changes are in RED. added INTERPOSING RELAY routine and updated WRINKLE GUARD, CYCLE DONE, and CYCLE START UP. Updated POWER UP flowchart to reflect that the language file should be loaded before displaying any message. changed all mentions of FAN to FAN/HOUR LOGGER, so that any time the FAN turns on the hour logger should also be on. updated Cycle start up, removed dual motor option and model diagnostics in cycle start up, reorganized to make more efficient. removed DISPLAY DIAGNOSTICS flowchart reorganized REVERSING to make more efficient. added Model Fault monitoring to Drying Diagnostics updated heat control and diagnostics, complete restructuring of routine. routine will now account for different model types and will check for latched relay first. Added belco drive output option to CYCLE START UP, REVERSING, COIN/FREE CYCLE RUNNING STATE, OPL- AUTOCYCLE, OPL MANUAL CYCLE, AND ROTATION SENSOR DIAGNOSTICS. added belco burner option to HEAT TWO BURNER SYSTEM. added automatic view cycle to OPL READY MODE. added non catastrophic fault call from coin handling. added fault handling of BURNER RETURN VOLTAGE and LATCHED HEAT RELAY to FAULT ROUTINE to handle the drive and fan shutting off due to the opening of the interposing relay. removed DEMO mode, this feature is better covered in ADC0006 PROGRAMMING MENU DOCUMENT Page 3 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 and ADC0009 ADC DISPLAY USER INTERFACE. 1.2 J.M. • • • • • • • • • • • • Added MAINTAIN HEAT routine. Made changes to HEAT ONE BURNER SYSTEM AND HEAT TWO BURNER SYSTEM to call MAINTAIN HEAT. Made changes to HEAT CONTROL AND DIAGNOSTICS to account for EXH HIGH LIMIT or BURNER HIGH LIMIT issues and to release heat control while in the radiant sensor diagnostics if another BURNER is calling for heat. Added OUTPUT REVERSING MODE and DIRECTIONAL REVERSING MODE routines and updated REVERSING to include calls to these functions. THESE FUCTIONS ARE NOT FINISHED AT THIS TIME. MORE CHANGES ARE NEEDED WHICH WILL EFFECT ROTATION SENSOR FAULTS AS WELL. Corrected EXHAUST PROBE DIAGNOSTICS AND AXIAL PROBE DIAGNOSTICS in regards to fault self clearing to take into account the 3 minutes of fault cool down. Made changes to HEAT CONTROL AND DIAGNOSTICS to take into account cycle temp setting being reached before heat is successfully ignited. Removed INTERPOSING RELAY ROUTINE, and update CYCLE START UP, WRINKLE GUARD AND CYCLE DONE to just open or close the relay. Updated HEAT OFF routine to coincide with the changes that were made to the other heat routines. Changed messaging in the CYCLE DONE and WRINKLE GUARD routines to reflect latest software changes, also clarified the credit handling in these two locations. Added HEAT OFF DIAGNOSTIC routine calls to READY MODE DIAGNOSTICS, DRYING DIAGNOSTICS and WRINKLE GUARD DIAGNOSTICS Updated HEAT ONE BURNER SYSTEM, HEAT TWO BURNER SYSTEM, HEAT CONTROL AND DIAGNOSTICS , COOL DOWN , PAUSE, MAIN DOOR DIAGNOSTICS, LINT DOOR DIAGNOSTICS,SAIL SWITCH OPEN AND FAULT ROUTINE to combine the turn off heat command and the call for HEAT OFF DIAGNOSTICS. Made changes to HEAT 1 BURNER SYSTEM and HEAT 2 BURNER SYSTEM to account for axial thermistor temperature when deciding the need for heat in a cycle. To MEC 12/06/04 Page 4 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART • 1.3 J.M. 1.4 ?? 1.5 S.G. TO MEC 12/13/04 ?? – Unsure what has been updated in this revision. To MEC 5/17/05 • To MEC 6/2/05 • • • • • A.L. S.G. Updated Lint Cleaning Routine to no longer show every 2 minutes in a drying cycle, the control will constantly show the message CLEAN LINT. • made changes to the HEAT DIAGNOSTIC AND CONTROL routine to account for excessive heat relay cycling while also providing some level of auto recoverability. • NOTE: Directional reversing is still not complete. • 1.6 ADC CATALOG #: ADC0007 • • • Made changes to the HEAT CONTROL AND DIAGNOSTIC routine to remove the option to have only one pockets heat turn on at a time & to remove a functions that created relay chatter. Added a note to the ADC WEB ADDRESS that states that the web address timer is reset when not in ready mode. Reviewed MODEL DIAGNOSTIC to see if electric model was accounted for. Electric model fault is covered in HEAT CONTROL AND DIAGNOSTIC. Corrected OUTPUT REVERSING MODE. The stop timer was being ignored after it had been started. Updated DIRECTIONAL REVERSING MODE. This section was currently incomplete. Removed ENERGY SAVING routine. Added an exhaust temperature limit of 120 when the Belco drive option is “disabled”. Format and grammar changes Corrected 13.1 FSS monitoring. Added description of OPL auto cycle Note: The latest revisions will be identified with RED text color formatting. Document changes that do not affect software functionality, such as document formatting, will not be indicated. Page 5 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 Page 6 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 TABLE OF CONTENTS DOCUMENT REVISIONS ...........................................................................................................................................................................2 1 DOCUMENT NOTES........................................................................................................................................................................10 1.1 1.2 DOCUMENT TITLE AND STORAGE NAME ........................................................................................................................ 10 ENGINEERING DOCUMENT RELEASING PROCESS ........................................................................................................10 2 PURPOSE OF THIS DOCUMENT ................................................................................................................................................. 10 3 SUPPORTING DOCUMENTS ......................................................................................................................................................... 10 4 FLOWCHART NOTES .....................................................................................................................................................................10 5 CONTROL POWER UP ROUTINES..............................................................................................................................................11 5.1 5.2 5.3 5.4 5.5 5.6 6 CREDIT HANDLING ROUTINES.................................................................................................................................................. 17 6.1 6.2 6.3 6.4 6.5 7 COIN HANDLING.....................................................................................................................................................................17 COIN APPLYING MONEY TO POCKET ................................................................................................................................ 18 BAD COIN ................................................................................................................................................................................. 19 DEBIT CARD HANDLING ....................................................................................................................................................... 20 DEBIT CARD EXTRACT MONEY ..........................................................................................................................................21 CYCLE START UP AND TIME MONITORING ROUTINES ....................................................................................................22 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 7.9 8 POWER UP ROUTINE .............................................................................................................................................................. 11 READY MODE ROUTINE ........................................................................................................................................................ 12 PROGRAM MODE ....................................................................................................................................................................13 COIN READY MODE ............................................................................................................................................................... 14 FREE READY MODE ............................................................................................................................................................... 15 OPL READY MODE..................................................................................................................................................................16 COIN/FREE CYCLE TIME CALCULATION .......................................................................................................................... 22 CYCLE START UP ....................................................................................................................................................................23 COIN/ FREE CYCLE RUNNING STATE .................................................................................................................................24 CYCLE TIME COUNT DOWN ................................................................................................................................................. 25 ADDITIONAL TIME .................................................................................................................................................................26 ADDITIONAL TIME- COIN ..................................................................................................................................................... 27 APPLYING CREDIT TO RUNNING POCKET ........................................................................................................................ 28 CLEARING CREDIT .................................................................................................................................................................29 CLEAR ESCROW ......................................................................................................................................................................30 CYCLE OPERATING MODES ROUTINES .................................................................................................................................31 8.1 8.2 8.3 8.4 8.5 8.6 8.7 8.8 8.9 8.10 8.11 8.12 REVERSING ..............................................................................................................................................................................31 OUTPUT REVERSING MODE ................................................................................................................................................. 32 DIRECTIONAL REVERSING MODE ......................................................................................................................................33 HEAT ......................................................................................................................................................................................... 34 HEAT ONE BURNER SYSTEM ...............................................................................................................................................35 HEAT TWO BURNER SYSTEM ..............................................................................................................................................36 HEAT CONTROL AND DIAGNOSTICS .................................................................................................................................37 HEAT CONTROL QUEUE ........................................................................................................................................................ 38 MAINTAIN HEAT.....................................................................................................................................................................39 COOL DOWN ............................................................................................................................................................................40 WRINKLE GUARD ...................................................................................................................................................................41 CYCLE DONE ...........................................................................................................................................................................42 Page 7 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 8.13 8.14 8.15 8.16 8.17 8.18 9 FAULT ROUTINE .....................................................................................................................................................................66 FAULT DISPLAY ROUTINE ................................................................................................................................................... 67 FAULT RECORDING ............................................................................................................................................................... 68 NON CATASTROPHIC FAULT ROUTINE ............................................................................................................................. 69 REGISTRATION ROUTINE ..................................................................................................................................................... 70 REGISTRATION CYCLE COUNT DOWN .............................................................................................................................. 71 DIRECT REGISTRATION ACCESS ........................................................................................................................................72 REGISTRATION CODE............................................................................................................................................................ 73 FIRE SUPPRESSION SYSTEM ...................................................................................................................................................... 74 13.1 13.2 13.3 13.4 13.5 14 POWER LOSS DIAGNOSTICS ................................................................................................................................................53 EXHAUST PROBE DIAGNOSTICS .........................................................................................................................................54 AXIAL PROBE DIAGNOSTICS ...............................................................................................................................................55 MAIN DOOR DIAGNOSTICS .................................................................................................................................................. 56 LINT DOOR DIAGNOSITCS .................................................................................................................................................... 57 SAIL SWITCH OPEN ................................................................................................................................................................ 58 SAIL SWITCH CLOSED ........................................................................................................................................................... 59 EXHAUST HIGH TEMP DIAGNOSTICS ................................................................................................................................ 60 ROTATION SENSOR DIAGNOSTICS ....................................................................................................................................61 REVERSING ROTATION SENSOR DIAG .............................................................................................................................. 62 MODEL DIAGNOSTICS ........................................................................................................................................................... 63 HEAT OFF DIAGNOSTICS ...................................................................................................................................................... 64 WATER PRESSURE DIAGNOSTICS ......................................................................................................................................65 REGISTRATION HANDLING ROUTINES ..................................................................................................................................70 12.1 12.2 12.3 12.4 13 READY MODE DIAGNOSTICS ...............................................................................................................................................49 DRYING DIAGNOSTICS ......................................................................................................................................................... 50 WRINKLE GUARD DIAGNOSTICS........................................................................................................................................51 FIRE SYSTEM DIAGNOSTICS ................................................................................................................................................52 FAULT HANDLING ROUTINES.................................................................................................................................................... 66 11.1 11.2 11.3 11.4 12 PAUSE ....................................................................................................................................................................................... 43 AUTOSTART ............................................................................................................................................................................44 RESTART .................................................................................................................................................................................. 45 SWITCHING CYCLES .............................................................................................................................................................. 46 OPL-AUTO CYCLE ..................................................................................................................................................................47 OPL- MANUAL CYCLE ........................................................................................................................................................... 48 DIAGNOSTIC ROUTINES .............................................................................................................................................................. 53 10.1 10.2 10.3 10.4 10.5 10.6 10.7 10.8 10.9 10.10 10.11 10.12 10.13 11 ADC CATALOG #: ADC0007 DRYER DIAGNOSTICS MODES ................................................................................................................................................... 49 9.1 9.2 9.3 9.4 10 ADC ENGINEERING CONTROLS GROUP FSS MONITORING ...................................................................................................................................................................74 THERMISTOR PROBE FSS MONITORING ........................................................................................................................... 75 EXHAUST PROBE FSS MONITORING ..................................................................................................................................76 S.A.F.E. / F.S.S. ACTIVATED................................................................................................................................................... 77 FIRE SUPPRESSION CLEAR ................................................................................................................................................... 78 MAINTENANCE ROUTINES ......................................................................................................................................................... 79 14.1 14.2 TEST BOOTH ROUTINE .......................................................................................................................................................... 79 LINT CLEANING FREQUENCY ROUTINE ........................................................................................................................... 80 Page 8 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 15 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 MARKETING ROUTINES .............................................................................................................................................................. 81 15.1 15.2 ADC WEB ADDRESS ............................................................................................................................................................... 81 BUZZER..................................................................................................................................................................................... 82 Page 9 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 1 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 DOCUMENT NOTES 1.1 DOCUMENT TITLE AND STORAGE NAME The title of this document consists of the following information: ADC Document #, which is assigned when the document is created. The document title Document Rev Number Ex. - ADC0007 Phase 8.4.1 Control Board Software Flowchart Rev 1.1 1.2 ENGINEERING DOCUMENT RELEASING PROCESS Changes should be made to a hard copy of the current released document before the electronic version is changed. When the document is ready to be updated the new document will be stored following the Document Title and Storage Name criteria set above, where the Revision number will be incremented before any changes are made. For example: ADC0007 Phase 8.4.1 Control Board Software Flowchart Rev 1.0 will be renamed ADC0007 Phase 8.4.1 Control Board Software Flowchart Rev 1.1 and then the changes will be implemented to the ADC0007 Phase 8.4.1 Control Board Software Flowchart Rev 1.1. The initial document ADC0007 Phase 8.4.1 Control Board Software Flowchart Rev 1.0 will not be deleted or modified. The changes will need to be documented in the document revision table as described in Section 1.2 of this document and should be in red text. Once the document has been reviewed and approved and is ready for release, the Released column will need to updated with the date the document was released and to whom. In addition to documenting the new document revision number in the revision table, the ..\..\..\ADC Control Specifications\ADC DOCUMENT CATALOG.xls file will need to be updated. The new revision number must be included and the date the document was released. Also the document link should be updated to the latest file. 2 PURPOSE OF THIS DOCUMENT The purpose of this document is to provide a flowchart representation of the Phase 8.4.1 control board software. 3 SUPPORTING DOCUMENTS 4 FLOWCHART NOTES All of the display messages will have a dual language feature, which is outlined in the programming menu document and the ADC DUAL COIN DISPLAY INTERFACE DOCUMENT. Page 10 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 5 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 CONTROL POWER UP ROUTINES 5.1 POWER UP ROUTINE Page 11 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 5.2 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 READY MODE ROUTINE START CHECKING FOR : -EXHAUST PROBE -DISPLAY NOT FUNCTION -MAIN DOOR -LINT DOOR -THERMISTOR PROBE READY MODE DIAGNOSTICS IS FIRE DETECTION ON? YES NO WATER PRESSURE DIAGNOSTICS HAS PROGRAM SWITCH BEEN TOGGLE FROM LO TO HIGH YES PROGRAM MODE NO IS CONTROL SET TO OPL MODE? YES NOTE: OPL READY MODE FOR DUAL POCKET DRYERS, EACH POCKET WILL CONTINUE ON ITS OWN PATH THROUGHOUT THE REST OF THE FLOWCHART/SOFTWARE. * SEE NOTE NO IS CONTROL SET TO FREE MODE? YES FREE READY MODE * SEE NOTE NO COIN READY MODE EACH POCKET SHOULD OPERATE INDEPENDENT OF EACH OTHER UNLESS OTHERWISE INDICATED. EXAMPLE- F.S.S OR PROGRAM MODE. CLEARING ESCROW * SEE NOTE ENERGY SAVING ADC WEB ADDRESS Page 12 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 5.3 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 PROGRAM MODE Page 13 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 5.4 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 COIN READY MODE DIRECT REGISTRATION START LINT CLEANING FREQUENCY NO YES IS CREDIT AVAILABLE? IS READY PROMPT SET TO READY? IS READY PROMPT SET TO CUSTOM? NO READY INSERT $0.25 TO START HI --------------------------------READY INSERT $0.25 TO START HI READY --------------------------------READY NO YES CUSTOM --------------------------------CUSTOM *SEE NOTE *SEE NOTE *SEE NOTE YES COIN HANDLING HAS TOP POCKET AMOUNT TO START BEEN MET? CLEARING CREDIT YES SELECT TEMP TO START YES ADD $X.XX TO START RETURN NO NO NO IS AVAILABLE CREDIT FROM POWER UP? YES IS CREDIT AVAILABLE ON ANY POCKET OR GLOBAL BANK? NO IS AVAILABLE CREDIT FROM POWER UP? HAS BOT POCKET AMOUNT TO START BEEN MET? NO APPLY POWER UP CREDIT TO TOP POCKET AMOUNT TO START BANK YES NO YES APPLY POWER UP CREDIT TO BOTTOM POCKET AMOUNT TO START BANK ADD $X.XX TO START SELECT TEMP TO START IS TOP POCKET TEMP KEY PRESSED? NO IS BOT POCKET TEMP KEY PRESSED? YES YES YES DEBIT CARD CONNECTED? NO COIN APPLYING MONEY TO POCKET DEBIT CARD EXTRACT MONEY COIN/FREE CYCLE TIME CALCULATION Page 14 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 5.5 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 FREE READY MODE START DIRECT REGISTRATION LINT CLEANING FREQUENCY FREE SELECT CYCLE HI --------------------------------FREE SELECT CYCLE HI IS TOP OR BOTTOM TEMP KEY PRESSED? YES COIN/FREE CYCLE TIME CALCULATION NO RETURN Page 15 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART ADC CATALOG #: ADC0007 5.6 OPL READY MODE START DIRECT REGISTRATION HAS VIEW CYCLE SUMMARY BEEN DISPLAYED FOR MORE THAN 5 SEC? LINT CLEANING FREQUENCY YES YES SELECT CYCLE TOWELS --------------------------------SELECT CYCLE TOWELS HAS THE MENU SELECTION CHANGED IN THE LAST 3 SEC? NO NO OPL VIEW CYCLE SUMMARY SEE PROGRAM MENU DOCUMENT ADC0006 OPL MENU TOGGLE IS TOP POCKET DOWN KEY/ BOTTOM POCKET UP KEY OR BOTTOM POCKET DOWN KEY PRESSED ? SEE PROGRAM MENU DOCUMENT ADC0006 YES NO NO IS TOP POCKET UP KEY PRESSED YES IS TOP POCKET STOP KEY SIMULTANEOUSLY PRESSED NO IS TOP POCKET START KEY PRESSED YES PROGRAM MODE NOTE: When the control enters program mode, via the TOP POCKET UP KEY and TOP POCKET STOP KEY, program mode must be exited with the TOP POCKET STOP KEY being pressed multiple times until the control returns back to READY mode. NO YES HAS START KEY BEEN PRESSED FOR MORE THAN 5 SECONDS NO HAS THE START KEY BEEN RELEASED NO YES YES IS BOTTOM POCKET START KEY PRESSED OPL CYCLE PARAMETER EDIT MENU- REGISTRATION NO SEE PROGRAM MENU DOCUMENT RETURN YES CYCLE START UP Page 16 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 6 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 CREDIT HANDLING ROUTINES 6.1 COIN HANDLING START IS A DEBIT CARD CONNECTED NO DEBIT CARD HANDLING IS THERE A RIGHT COIN PULSE YES IS COIN PULSE VALID NO YES ADD RIGHT COIN DENOMINATION TO GLOBAL CREDIT BANK NO ADD RIGHT COIN DENOMINATION TO COIN VAULT IS THERE A LEFT COIN PULSE YES IS COIN PULSE VALID NO BAD COIN YES ADD LEFT COIN DENOMINATION TO GLOBAL CREDIT BANK NON CATASTROPHIC FAULT ROUTINE BAD COIN NO ADD LEFT COIN DENOMINATION TO COIN VAULT RETURN Page 17 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 6.2 ADC CATALOG #: ADC0007 COIN APPLYING MONEY TO POCKET START IS THIS THE FIRST CYCLE STARTED AFTER A POWER LOSS? NO WAS TOP POCKET START BUTTON PRESSED IS THIS THE FIRST CYCLE STARTED AFTER A POWER LOSS? YES NO NO YES YES REMOVE AMOUNT TO START FROM GLOBAL CREDIT BANK AND PLACE INTO BOT POCKET AMOUNT TO START BANK IS CONTROL IN ACCUM. TIME YES REMOVE AMOUNT TO START FROM GLOBAL CREDIT BANK AND PLACE INTO TOP POCKET AMOUNT TO START BANK PLACE REMAINING GLOBAL CREDIT BANK INTO BOT POCKET AMOUNT TO START BANK PLACE REMAINING GLOBAL CREDIT BANK INTO TOP POCKET AMOUNT TO START BANK YES IS CONTROL IN ACCUM. TIME NO NO REMOVE ANY AMOUNT ABOVE AMOUNT TO START FROM GLOBAL CREDIT BANK AND PLACE INTO BOT POCKET ESCROW BANK REMOVE ANY AMOUNT ABOVE AMOUNT TO START FROM GLOBAL CREDIT BANK AND PLACE INTO TOP POCKET ESCROW BANK IS AMOUNT IN ESCROW => THAN AMOUNT FOR TOP OFF NO NO YES REMOVE AMOUNT FOR TOP OFF FROM ESCROW AND ADD TO BOT OFF BANK IS AMOUNT IN ESCROW => THAN AMOUNT FOR TOP OFF YES RETURN REMOVE AMOUNT FOR TOP OFF FROM ESCROW AND ADD TO TOP OFF BANK Page 18 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 6.3 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 BAD COIN START YES IS 3 SEC BAD COIN RESET DELAY COMPLETE? IS CONTROL SET TO BAD COIN RESET? YES YES NO IS 15 SEC BAD COIN LOCKOUT DELAY COMPLETE? NO NO IGNORE COIN INPUTS IGNORE COIN INPUTS RETURN Page 19 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 6.4 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 DEBIT CARD HANDLING START IS KEEP ALIVE SIGNAL PRESENT? NO DEBIT CARD DIAGNOSTICS YES DOES DEBIT CARD READER HAVE A READY MODE MESSAGE? YES DISPLAY READY MODE MESSAGE INSTEAD OF DEFAULT MESSAGE IS TOP DRYER RUNNING NO IS DRYER IN ACCUM. COIN MODE YES YES NO NO IS CARD INSERTED? YES NO IS IT A SERVICE CARD? YES IS BALANCE GREATER THAN TOP AMOUNT TO START NO NO IS BALANCE GREATER THAN TOP OFF INSUFFICIENT FUNDS YES AMOUNT TO START HAS BEEN MET FOR TOP POCKET YES TOP OFF HAS BEEN MET FOR TOP POCKET DEBIT CARD PROGRAMMING IS BOTTOM DRYER RUNNING NO IS DRYER IN ACCUM. COIN MODE YES YES NO NO IS BALANCE GREATER THAN AMOUNT TO START YES RETURN BOT POCKET AMOUNT TO START HAS BEEN MET NO NO INSUFFICIENT FUNDS IS BALANCE GREATER THAN TOP OFF YES TOP OFF HAS BEEN MET FOR BOTTOM POCKET Page 20 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 6.5 ADC CATALOG #: ADC0007 DEBIT CARD EXTRACT MONEY START NO WAS TOP POCKET START BUTTON PRESSED IS TOP DRYER RUNNING YES YES IS DRYER IN ACCUM. COIN MODE YES NO NO SEND DEBIT CARD READER VF (VEND FULL) SEND DEBIT CARD READER VT (VEND TOP OFF) NO WAS CREDIT ACKNOWLEDGED ? IS BOTTOM DRYER RUNNING NO YES IS DRYER IN ACCUM. COIN MODE APPLY AMOUNT TO START TO BOTTOM POCKET AMOUNT TO START BANK NO WAS CREDIT ACKNOWLEDGED ? YES YES APPLY AMOUNT TO START TO TOP POCKET AMOUNT TO START BANK DEBIT CARD DIAGNOSTICS APPLY AMOUNT FOR TOP OFF TO TOP POCKET TOP OFF BANK YES NO SEND DEBIT CARD READER VT (VEND TOP OFF) NO YES HAS COMM. TIMEOUT EXPIRED? YES SEND DEBIT CARD READER VF (VEND FULL) WAS CREDIT ACKNOWLEDGED ? NO NO NO NO HAS COMM. TIMEOUT EXPIRED? YES NO WAS CREDIT ACKNOWLEDGED ? YES DEBIT CARD DIAGNOSTICS APPLY AMOUNT FOR TOP OFF TO BOTTOM POCKET TOP OFF BANK RETURN Page 21 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 7 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 CYCLE START UP AND TIME MONITORING ROUTINES 7.1 COIN/FREE CYCLE TIME CALCULATION START LOAD SELECTED CYCLE PARAMETERS YES IS DRYER SET TO FREE MODE NO VEND TIME FOR AMOUNT TO START MULTIPLY POCKET’S AMOUNT TO START BANK BY TIME FOR AMOUNT TO START TO DETERMINE CYCLE TIME MULTIPLY POCKET’S AMOUNT TO FOR TOP OFF BANK BY TIME FOR TOP OFF AND ADD ADDITIONAL TIME TO CYCLE TIME IS TIME > THAN 99 MINUTES YES LIMIT CYCLE TIME TO 99 MINUTES LEAVE CREDIT ALONE NO REGISTRATION CYCLE TIME COUNT DOWN CYCLE START UP Page 22 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 7.2 ADC CATALOG #: ADC0007 CYCLE START UP START IS DRYER SET TO OPL MODE? FIRE SYSTEM DIAGNOSTICS YES NO CLOSE INTERPOSING RELAY IS ANOTHER DRIVE OR FAN OUTPUT BEING TURNED ON FOR THE OTHER POCKET? YES NO YES WAIT 3 SECONDS IS DRYER A STEAM DRYER? NO IS SAIL SWITCH OPEN? TURN ON FAN/ HOUR LOGGER YES TURN ON FAN/ HOUR LOGGER NO SAIL SWITCH CLOSED DIAGNOSTICS SAIL SWITCH OPEN DIAGNOSTICS IS BELCO DRIVE OUTPUT OPTION ACTIVE? YES NO OPL -MANUAL CYCLE IS CYCLE SET TO AUTO? YES OPLAUTO CYCLE NO IS EXHAUST TEMPERATURE SETTING > 120? YES YES WAIT 2 SECONDS THEN TURN ON ACTIVE DRIVE CHANGE EXHAUST TEMPERATURE SETTING TO 120 NO IS CONTROL SET TO OPL MODE? NO COIN/FREE CYCLE RUNNING STATE Page 23 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 7.3 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 COIN/ FREE CYCLE RUNNING STATE START IS CYCLE TIME COMPLETE YES NO DRYING CYCLE DIAGNOSTICS ADDITIONAL TIME IS BELCO DRIVE OUTPUT OPTION ACTIVE HEAT REVERSING Yes SWITCHING CYCLES PAUSE SHOULD WRINKLE GUARD BE ACTIVE FOR THIS CYCLE? NO YES NO CYCLE TIME COUNT DOWN WRINKLE GUARD XX MINUTES REMAIN CYCLE DONE Page 24 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 7.4 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 CYCLE TIME COUNT DOWN START YES IS THERE CREDIT IN THE AMOUNT TO START BANK? COUNT DOWN TIME FOR AMOUNT TO START RECALCULATE CREDIT REMAINING FOR AMOUNT TO START NO RETURN YES IS THERE CREDIT IN THE AMOUNT FOR TOP OFF BANK? COUNT DOWN TOP OFF TIME NO RECALCULATE CREDIT REMAINING FOR AMOUNT FOR TOP OFF. CYCLE TIME COMPLETE RETURN Page 25 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 7.5 ADC CATALOG #: ADC0007 ADDITIONAL TIME START IS CONTROL SET TO FREE MODE? YES NO COIN HANDLING IS HI OR LO KEY PRESS FOR MORE THAN 3 SECONDS. NO NO YES IS GLOBAL CREDIT AVAILABLE? YES 5:00 IS HI KEY PRESSED? YES ADD TIME TO DRYING CYCLE YES SUBTRACT TIME TO DRYING CYCLE ADDITIONAL TIME- COIN NO IS LO KEY PRESSED? RETURN Page 26 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 7.6 ADC CATALOG #: ADC0007 ADDITIONAL TIME- COIN START IS DRYER SET TO ACCUM. TIME MODE? YES NO IS AMOUNT IN GLOBAL CREDIT + POCKET’S ESCROW BALANCE => AMOUNT FOR TOP OFF? YES SELECT TEMP TO ADD TIME NO IS ADDITIONAL TIME 30 SEC TIMER ACTIVE? IS TEMP SELECTED ON THIS POCKET? WAS TIMER PREVIOUSLY ACTIVE? NO YES YES IS ADDITIONAL TIME TIMER EXPIRED? HAS MORE CREDIT BEEN ADDED SINCE TIMER WAS LAST ACTIVE? NO ACTIVATE 30 SEC TIMER YES YES APPLY CREDIT TO RUNNING POCKET NO YES NO ADD XX FOR ADDITIONAL TIME WAS MORE CREDIT ADDED TO GLOBAL BANK? NO RETURN YES RESET 30 SEC TIMER NO Page 27 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 7.7 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 APPLYING CREDIT TO RUNNING POCKET START YES IS DRYER SET TO ACCUM. TIME MODE? NO DIVIDE GLOBAL CREDIT BY THE AMOUNT TO START AND MULTIPLY RATIO BY TIME FOR AMOUNT TO START FOR SELECT TEMP AND ADD RESULTING TIME TO CYCLE. PLACE GLOBAL CREDIT INTO SELECTED POCKET’S ESCROW BANK PLACE GLOBAL CREDIT INTO SELECTED POCKET’S AMOUNT TO START BANK NO RETURN IS AMOUNT IN ESCROW => THAN AMOUNT FOR TOP OFF YES REMOVE AMOUNT FOR TOP OFF FROM ESCROW AND ADD TO TOP OFF BANK ADD TOP OFF TIME FOR SELECTED TEMP TO CYCLE Page 28 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 7.8 ADC CATALOG #: ADC0007 CLEARING CREDIT START IS MACHINE PAUSED? NO RETURN YES YES IS DRYER IN FREE MODE? NO HAS THE FOLLOWING KEY PRESSES BE MADE WITHIN 3 SECONDS SELECT TEMP TO RESTART OR PRESS “PAUSE” TO CLEAR CYCLE PAUSE CONTINUOUSLY HELD WHILE PRESSING HI-HI-HI-LO-LO-MED NO YES SELECT TEMP TO RESTART NO RETURN IS PAUSE KEY PRESSED? YES CLEAR CREDIT? CLEAR CREDIT AND ALL TIME REMAINING NO NO HAS PAUSE AND A KEY BEEN PRESSED? READY MODE YES HAS A KEY OTHER THAN PAUSE BEEN PRESSED? CLEAR CREDIT AND ALL TIME REMAINING YES RETURN READY MODE Page 29 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 7.9 ADC CATALOG #: ADC0007 CLEAR ESCROW IS CLEAR ESCROW SETTING SET TO 0? START YES RETURN NO DOES POCKET HAVE ESCROW CREDIT? NO YES IS CLEAR ESCROW TIMER ACTIVE? RESET CLEAR ESCROW TIMER AND LEAVE ACTIVE NO START TIMER YES IS CLEAR ESCROW TIMER > CLEAR ESCROW SETTING? CLEAR ALL CREDIT AND ESCROW FROM THIS POCKET YES NO HAS MORE CREDIT BEEN ADDED TO THIS POCKET SINCE THE TIMER HAS STARTED OR WAS LAST RESET? YES NO ARE BOTH POCKETS IDLE? NO END GLOBAL TIMER IS THERE GLOBAL ESCROW CREDIT? HAS CYCLE BEEN SELECTED? YES YES NO RETURN YES RETURN NO RESET CLEAR GLOBAL ESCROW TIMER AND LEAVE ACTIVE IS CLEAR GLOBAL ESCROW TIMER ACTIVE? NO START TIMER YES IS CLEAR GLOBAL ESCROW TIMER > CLEAR ESCROW SETTING? YES NO HAS MORE CREDIT BEEN ADDED TO DRYER SINCE THE TIMER HAS STARTED OR WAS LAST RESET? YES END GLOBAL TIMER RETURN HAS CYCLE BEEN SELECTED? YES CLEAR ALL CREDIT FROM GLOBAL ESCROW NO NO Page 30 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 8 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 CYCLE OPERATING MODES ROUTINES 8.1 REVERSING START IS BELCO DRIVE OUTPUT OPTION ACTIVE NO YES IS DRYER A REVERSING MODEL? NO RETURN YES IS REVERSING OPTION ON FOR SELECTED CYCLE? NO YES YES IS A DRIVE OUTPUT / DIRECTION DISABLED FOR THIS POCKET? NO IS REVERSING SET TO OUTPUT REVERSING MODE? OUTPUT REVERSING MODE DIRECTIONAL REVERSING MODE RETURN Page 31 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 8.2 ADC CATALOG #: ADC0007 OUTPUT REVERSING MODE START NO IS ANOTHER DRIVE OR FAN OUTPUT NOT BEING TURNED ON FOR THE OTHER POCKET? YES WAIT 3 SECONDS IS ACTIVE DRIVE OUTPUT AND TIMER ACTIVE? NO IS STOP TIME TIMER ACTIVE? START ACTIVE DRIVE AND DRIVE OUTPUT TIMER NO YES YES IS STOP TIMER > STOP TIME? NO IS DRIVE OUTPUT TIMER < SPIN TIME? TURN OFF DRIVE OUTPUTS NO YES WAS LAST ACTIVE DRIVE FORWARD? IS STOP TIME TIMER ACTIVE? NO NO START STOP TIMER YES YES ASSIGN ACTIVE DRIVE TO REV ASSIGN ACTIVE DRIVE TO FWD TURN ON ACTIVE DRIVE TURN ON ACTIVE DRIVE RETURN YES Page 32 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 8.3 ADC CATALOG #: ADC0007 DIRECTIONAL REVERSING MODE Fwd. dwell START Rev. Drive relay Direction relay IS ANOTHER DRIVE OR FAN OUTPUT NOT BEING TURNED ON FOR THE OTHER POCKET? NO YES WAIT 3 SECONDS IS DRIVE OUTPUT AND TIMER ACTIVE? NO IS STOP TIME TIMER ACTIVE? START DRIVE AND DRIVE OUTPUT TIMER NO YES YES SET DIRECTION BIT = 1 IS STOP TIMER + 1 > STOP TIME? NO IS DRIVE OUTPUT TIMER < SPIN TIME? NO TURN OFF DRIVE OUTPUT YES IS DIRECTION BIT SET = 0? NO IS STOP TIME TIMER ACTIVE? TURN ON REVERSING RELAY NO START STOP TIMER YES If dir bit = 0 Forward If dir bit = 1 Reverse YES WAIT ONE SECOND YES IS REVERSING RELAY OFF? SET DIRECTION BIT = 1 NO WAIT 1 SECOND SET DIRECTION BIT = 0 TURN OFF REVERSING RELAY START DRIVE AND DRIVE OUTPUT TIMER RETURN YES Page 33 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 8.4 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 HEAT START IS CONTROL SET TO OPL MODE? NO IS TIME REMAINING GREATER THAN COOL DOWN TIME? COOL DOWN NO YES YES IS DRY MODE COMPLETE? RETURN YES NO IS BURNER SETUP SET TO DUAL BURNERS ? YES NO HEAT TWO BURNER SYSTEM HEAT ONE BURNER SYSTEM RETURN Page 34 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 8.5 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 HEAT ONE BURNER SYSTEM START NOTE: THE TEMP READINGS IN THIS FLOWCHART REFER TO BOTH THE EXHAUST TRANSDUCER AND AXIAL THERMISTOR, WHERE THE TEMPERATURE SETPOINTS ARE DIFFERENT FROM EACH OTHER. IS TEMP ABOVE SET POINT YES NO IS HEAT OUTPUT ON? NO YES IS HEAT OUTPUT ON? IS HEAT DISABLED YES NO NO YES IS TEMP ABOVE ( SET POINT - 5 ° F)? HEAT CONTROL AND DIAGNOSTICS ACTIVATE BURNER MAINTAIN HEAT YES HEAT OFF DIAGNOSTICS NO RETURN Page 35 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 8.6 ADC CATALOG #: ADC0007 HEAT TWO BURNER SYSTEM NOTE: WHEN THIS OPTION IS SET TO ONE IN THE CYCLE SETTINGS THE CYCLE TEMP RANGE IS CHANGED. REFER TO ADC0006 FOR MORE DETAILS. START IS BELCO BURNER OPTION SET TO 2? YES NOTE: THE TEMP READINGS IN THIS FLOWCHART REFER TO BOTH THE EXHAUST TRANSDUCER AND AXIAL THERMISTOR, WHERE THE TEMPERATURE SETPOINTS ARE DIFFERENT FROM EACH OTHER. IS TEMP ABOVE SET POINT HEAT ONE BURNER SYSTEM NO HEAT OFF DIAGNOSTICS YES NO NO ARE BOTH BURNERS ON? YES NO MAINTAIN HEAT YES ARE TWO BURNERS ACTIVE? IS TEMP ABOVE (SET POINT -12 ° F) YES IS LEAD BURNER ON IS TEMP ABOVE SET POINT + 10 ° MAINTAIN HEAT NO HEAT CONTROL AND DIAGNOSTICS HEAT CONTROL AND DIAGNOSTICS ACTIVATE LEAD BURNER ACTIVATE LEAD BURNER YES NO YES MAINTAIN HEAT ASSIGN LEAD BURNER POSITION TO AUXILIARY BURNER NO ARE BOTH BURNERS OFF? YES DO NOT ASSIGN LEAD BURNER POSITION TO AUXILIARY BURNER NO YES IS AUXILIARY BURNER ON? HEAT OFF DIAGNOSTICS NO MAINTAIN HEAT HEAT CONTROL AND DIAGNOSTICS ACTIVATE AUXILIARY BURNERS RETURN Page 36 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 8.7 ADC CATALOG #: ADC0007 HEAT CONTROL AND DIAGNOSTICS THE HEAT RETURN SIGNAL IS READING 120V BUT THE HEAT RELAY I S NOT LATCHED ON. THIS MEANS THAT SOMEWHERE THERE IS A FAULT IN THE H EAT SIGNAL TO THE BURNER OR IN THE GAS RETURN SIGNAL START FAULT ROUTINE IS HEAT RELAY RETURN SIGNAL ON? YES LATCHED HEAT RELAY FAULT NO IS DRYER AN ELECTRIC OR STEAM MODEL IS THIS POCKET’S GAS RETURN SIGNAL =120V? NO NO Yes YES FAULT ROUTINE TURN ON HEAT SIGNAL TURN ON HEAT SIGNAL BURNER RETURN VOLTAGE FAULT WAIT 2 SEC YES A IS GAS RETURN SIGNAL =120V? IS HEAT RELAY RETURN PRESENT? YES IS GAS RETURN SIGNAL =120V? CHANGE MODEL TYPE TO GAS NON REVERSING NO ACTIVATE TIMER FAULT ROUTINE RETURN NO YES NO IS HEAT TURN ON TIME TIMER ACTIVE? MODEL FAULT IS RADIANT SENSOR COOL DOWN TIMER ACTIVE? YES IS GAS RETURN SIGNAL = 120V? NO No RETURN NO ACTIVATE TIMER A YES Yes HAS HEAT TURN ON TIME TIMER EXPIRED? YES NOTE: THE TEMP NON READINGS IN THIS FLOWCHART CATASTROPHIC FAULT REFER TO BOTH ROUTINE THE EXHAUST TRANSDUCER HEAT IGNITION AND AXIAL FAILURE THERMISTOR, WHERE THE TEMPERATURE SETPOINTS ARE DIFFERENT FROM HEAT OFF EACH OTHER. DIAGNOSTICS NO NO NO IS TEMP ABOVE SETPOINT? IS TEMP ABOVE SETPOINT? NO HAS RADIANT SENSOR COOL DOWN TIMER EXPIRED? YES NON CATASTROPHIC FAULT ROUTINE Yes HEAT OFF DIAGNOSTICS YES DISABLE HEAT FOR 2 MINUTES (HEAT DISABLE SETTING) RADIANT SENSOR FAILURE HEAT OFF DIAGNOSTICS NON CATASTROPHIC FAULT ROUTINE EXHAUST HIGH LIMIT FAILURE RETURN Page 37 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 8.8 ADC CATALOG #: ADC0007 HEAT CONTROL QUEUE START IS BURNER HEAT REQUEST ALREADY IN QUEUE? NO ADD POCKET/ BURNER TO FIFO QUEUE. YES IS ANY GAS RETURN SIGNAL==120V? YES RETURN NO IS CONTROL A SINGLE POCKET UNIT? NO IS DRYER A DUAL BURNER SYSTEM? YES TURN ON THE FIRST BURNER ON THE FIFO QUEUE. No YES IS THE FIRST BURNER ON THE FIFO QUEUE IN THE SAME POCKET AS THE LAST BURNER THAT WAS TURN ON? HEAT CONTROL NO NO RETURN YES IS THERE ANOTHER BURNER IN THE QUEUE NO YES SWAP PRIORITY OF BURNERS IN FIFO QUEUE Page 38 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 8.9 ADC CATALOG #: ADC0007 MAINTAIN HEAT START IS BURNER RETURN SIGNAL PRESENT? NO RETURN YES IS DRYER AN ELECTRIC OR STEAM MODEL YES CHANGE MODEL TYPE TO GAS NON REVERSING NO NO FAULT ROUTINE IS SIGNAL PRESENT FOR MORE THAN 3 SECONDS? MODEL FAULT YES HEAT OFF DIAGNOSTICS Page 39 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 8.10 ADC CATALOG #: ADC0007 COOL DOWN START IS CONTROL SET TO OPL MODE? YES NO IS COOL DOWN TIMER ACTIVE? NO HEAT OFF DIAGNOSTICS NO START COUNT DOWN TIMER BASED ON THE "COOL DOWN TIME" FOR THE CYCLE IN PROGRESS YES WAS DRY TIME SET TO 0? YES IS COOL DOWN TIMER DONE? NO "COOL DOWN TEMP XXX", "X MIN REMAIN" IS HEAT ACTIVE? NO YES YES IS EXHAUST TEMP <= "COOL DOWN TEMP" OR COOL DOWN TIMER DONE" ? YES STOP FAN/HOUR LOGGER AND DRIVE. HEAT OFF DIAGNOSTICS NO NO RETURN HAS CYCLE TIME EXPIRED? NO XX MIN YES STOP FAN/HOUR LOGGER AND DRIVE. RETURN Page 40 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 8.11 ADC CATALOG #: ADC0007 WRINKLE GUARD BUZZER END OF DRYING CYCLE START START 15 MINUTE TIMER YES START 99 MINUTE TIMER IS 15 MINUTE DELAY COMPLETE? NO WRINKLE GUARD CYCLE DONE BUZZER WRINKLE GUARD DIAGNOSTICS WRINKLE GUARD START UP JOG FAN/HOUR LOGGER AND ACTIVE DRIVE FOR 15 SECS RESET 5 MIN TIMER IS MAIN OR LINT DOOR OPEN? NO COIN HANDLING NO BUZZER END OF WRINKLE GUARD CYCLE YES IS NEW CREDIT AVAILABLE? YES CYCLE DONE OPEN INTERPOSING RELAY WRINKLE GUARD DIAGNOSTICS CHECK LOAD HAS THE MAIN DOOR BEEN OPENED? NO COIN READY MODE YES IS MAIN OR LINT DOOR OPEN? YES YES NO COIN HANDLING NO IS NEW CREDIT AVAILABLE YES HAS THE MAIN DOOR BEEN OPENED? CHECK LOAD YES NO NO YES IS 99 MINUTES TIMER COMPLETE? OPEN INTERPOSING RELAY NO CYCLE DONE IS 5 MIN TIMER ACTIVE? NO START 5 MINUTE TIMER IS 5 MINUTE DELAY COMPLETE? COIN READY MODE YES Page 41 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 8.12 ADC CATALOG #: ADC0007 CYCLE DONE START BUZZER CYCLE DONE WRINKLE GUARD DIAGNOSTICS NO IS MAIN OR LINT DOOR OPEN? YES NO COIN HANDLING IS NEW CREDIT AVAILABLE? YES CHECK LOAD NO HAS THE MAIN DOOR BEEN OPENED? YES OPEN INTERPOSING RELAY COIN READY MODE Page 42 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 8.13 ADC CATALOG #: ADC0007 PAUSE START WAS THE PAUSE KEY PRESSED? NO RETURN YES HEAT OFF DIAGNOSTICS TURN OFF FAN/HOUR LOGGER, DRIVE CLEARING CREDIT IS MAIN OR LINT DOOR OPEN? YES NO START 20 SECOND PAUSE TIMER STOP CYCLE COUNT DOWN NO IS 20 SEC PAUSE TIMER ACTIVE? YES WAS MAIN OR LINT DOOR OPENED ? NO RESTART CYCLE COUNT DOWN YES YES AUTO START IS 20 SECOND PAUSE TIME COMPLETE? RESTART NO RETURN Page 43 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 8.14 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 AUTOSTART START IS AUTO START ON? NO RETURN YES DID CONTROL RETURN FROM A POWER CYCLE? YES NO DID CONTROL JUST EXIT PROGRAM MODE? YES NO IS MAIN OR LINT DOOR OPEN? YES NO SELECT LAST RUNNING CYCLE RESTART Page 44 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 8.15 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 RESTART START LOAD SELECTED CYCLE PARAMETERS MULTIPLY POCKET’S AMOUNT TO START BANK BY TIME FOR AMOUNT TO START TO DETERMINE CYCLE TIME MULTIPLY POCKET’S AMOUNT TO FOR TOP OFF BANK BY TIME FOR TOP OFF AND ADD ADDITIONAL TIME TO CYCLE TIME IS TIME > THAN 99 MINUTES YES LIMIT CYCLE TIME TO 99 MINUTES LEAVE CREDIT ALONE NO CYCLE START UP Page 45 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 8.16 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 SWITCHING CYCLES START IS DRYER IN OPL MODE? YES RETURN NO HAS A NEW TEMPERATURE KEY BEEN PRESSED? NO YES LOAD SELECTED CYCLE PARAMETERS MULTIPLY POCKET’S AMOUNT TO START BANK BY TIME FOR AMOUNT TO START TO DETERMINE CYCLE TIME MULTIPLY POCKET’S AMOUNT TO FOR TOP OFF BANK BY TIME FOR TOP OFF AND ADD ADDITIONAL TIME TO CYCLE TIME IS TIME > THAN 99 MINUTES YES LIMIT CYCLE TIME TO 99 MINUTES LEAVE CREDIT ALONE NO RESET FSS HEAT ON ONCE THIS CYCLE BIT RETURN Page 46 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 8.17 ADC CATALOG #: ADC0007 OPL-AUTO CYCLE START IS DRYING CYCLE AND COOL DOWN TIME COMPLETE? YES NO NO IS DRYING CYCLE TIME COMPLETE? YES DRYING CYCLE DIAGNOSTICS DRYING CYCLE DIAGNOSTICS HEAT COOL DOWN REVERSING REVERSING PAUSE PAUSE IS BELCO DRIVE OUTPUT OPTION ACTIVE YES AUTO CYCLE IS CYCLE DRIED? COUNT DOWN CYCLE TIME YES DRYING CYCLE TIME COMPLETE SHOULD WRINKLE GUARD BE ACTIVE FOR THIS CYCLE? NO COOL DOWN TEMP XX, XX MINUTES REMAIN YES NO NO WRINKLE GUARD IS ELAPSED DRYING TIME > AUTO CYCLE TIMEOUT SETTING? YES NO AUTO DRY FINISHING...ELAPSED DRYING TIME XX MINUTES CYCLE DONE Page 47 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 8.18 ADC CATALOG #: ADC0007 OPL- MANUAL CYCLE START IS DRYING CYCLE AND COOL DOWN TIME COMPLETE? YES NO NO IS DRYING CYCLE TIME COMPLETE? YES DRYING CYCLE DIAGNOSTICS DRYING CYCLE DIAGNOSTICS HEAT COOL DOWN IS BELCO DRIVE OUTPUT OPTION ACTIVE REVERSING REVERSING YES PAUSE PAUSE COUNT DOWN CYCLE TIME COUNT DOWN CYCLE TIME SHOULD WRINKLE GUARD BE ACTIVE FOR THIS CYCLE? NO YES NO DRYING TEMP XX, XX MINUTES REMAIN COOL DOWN TEMP XX, XX MINUTES REMAIN WRINKLE GUARD CYCLE DONE Page 48 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 9 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 DRYER DIAGNOSTICS MODES 9.1 READY MODE DIAGNOSTICS START FSS MONITORING EXHAUST PROBE DIAGNOSTICS AXIAL PROBE DIAGNOSTICS DISPLAY DIAGNOSTIC MAIN DOOR DIAGNOSTICS LINT DOOR DIAGNOSTICS LOW VOLTAGE DIAGNOSTICS HEAT OFF DIAGNOSTICS RETURN Page 49 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 9.2 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 DRYING DIAGNOSTICS START FSS MONITORING EXHAUST PROBE DIAGNOSTICS AXIAL PROBE DIAGNOSTICS DISPLAY DIAGNOSTIC MAIN DOOR DIAGNOSTICS LINT DOOR DIAGNOSTICS SAIL SWITCH OPEN LOW VOLTAGE DIAGNOSTICS EXHAUST HIGH TEMP FAULT ROTATION SENSOR FAULT MODEL DIAGNOSTICS HEAT OFF DIAGNOSTICS RETURN Page 50 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 9.3 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 WRINKLE GUARD DIAGNOSTICS START FSS MONITORING EXHAUST PROBE DIAGNOSTICS AXIAL PROBE DIAGNOSTICS DISPLAY DIAGNOSTIC MAIN DOOR DIAGNOSTICS LINT DOOR DIAGNOSTICS LOW VOLTAGE DIAGNOSTICS HEAT OFF DIAGNOSTICS RETURN Page 51 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 9.4 ADC CATALOG #: ADC0007 FIRE SYSTEM DIAGNOSTICS START IS F.S.S. OPTION ON? NO RETURN YES WATER PRESSURE DIAGNOSTICS IS CONTROL SET TO OPL NO YES IS S.A.F.E. DISABLED? IS S.A.F.E. DISABLED? NO YES APPEND S.A.F.E. DISABLED... TO READY UP MESSAGE. NO YES YES HAS WATER PRESSURE BEEN PRESENT FOR MORE THAN 10 HOURS? NO RETURN IS HOUR LOGGER > 5000 HOURS YES IS WATER PRESSURE PRESENT TIMER ACTIVE? ENABLE S.A.F.E. TEMPERATURE REDUCTION NO YES NO ACTIVATE WATER PRESSURE PRESENT TIMER APPEND S.A.F.E. DISABLED... TO READY UP MESSAGE. IS CYCLE STARTING? NO RETURN YES IS S.A.F.E. DISABLED TEMPERATURE REDUCTION ENABLED? YES NO S.A.F.E. DISABLED...SELECT START TO CONTINUE S.A.F.E. DISABLED, MAX CYCLE TEMPERATURE IS 120°F...SELECT START TO CONTINUE Page 52 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 10 ADC CATALOG #: ADC0007 DIAGNOSTIC ROUTINES 10.1 POWER LOSS DIAGNOSTICS START IS A LOW VOLTAGE CONDITION DETECTED? RETURN YES TURN OFF BOTH LCD’S BACKLIGHTS TURN ALL OUTPUTS OFF STORE- COIN VAULT TOP AND BOTTOM HOUR LOGGER ON TIME HOUR LOGGER TOP POCKET SUM OF- AMOUNT TO START, ESCROW AND TOP OFF BOTTOM POCKET SUM OF - AMOUNT TO START, ESCROW AND TOP OFF FAULT RECORDS PROGRAM PARAMETERS NO WAIT TILL POWER DIES HAS POWER BEEN REESTABLISHED? YES POWER UP Page 53 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 10.2 ADC CATALOG #: ADC0007 EXHAUST PROBE DIAGNOSTICS START IS CONTROL IN FAULT MODE FOR AN EXHAUST PROBE FAULT ? YES RETURN NO IS FAULT COOL DOWN COMPLETE? NO YES IS EXHAUST PROBE TEMP < (-)100° F IS EXHAUST PROBE TEMP < (-)100° F NO NO IS EXHAUST PROBE TEMP >260° F IS EXHAUST PROBE TEMP >260° F STOP AND RESET 30 SEC FAULT RESET TIMER. YES IS TIMER ACTIVE? NO NO NO YES NO START 3 SEC TIMER RETURN IS 30 SEC FAULT RESET TIMER ACTIVE? YES START 30 SEC TIMER YES YES NO IS 30 SEC FAULT RESET TIMER COMPLETE? YES CLEAR EXHAUST PROBE FAULT CONDITION IS EXHAUST PROBE TEMP < (-)100° F NO HAS 3 SEC TIMER EXPIRED YES NO IS EXHAUST PROBE TEMP >260° F YES NO FAULT ROUTINE RETURN RESET 3 SEC TIMER FAULT CODEEXHAUST PROBE FAULT Page 54 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 10.3 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 AXIAL PROBE DIAGNOSTICS START IS CONTROL IN FAULT MODE FOR AN AXIAL PROBE FAULT ? YES RETURN NO IS FAULT COOL DOWN COMPLETE? NO YES IS AXIAL THERMISTOR PROBE OPEN? IS AXIAL THERMISTOR PROBE OPEN? NOTE: NO NO IS AXIAL THERMISTOR PROBE SHORTED? STOP AND RESET 30 SEC FAULT RESET TIMER. YES THERMISTOR WILL BE CONSIDERED OPEN ONCE THE TEMPERATURE REACHES (-)52° F IS AXIAL THERMISTOR PROBE SHORTED? YES NO NO NO IS 30 SEC FAULT RESET TIMER ACTIVE? IS TIMER ACTIVE? NO START 3 SEC TIMER RETURN YES START 30 SEC TIMER YES YES NO IS 30 SEC FAULT RESET TIMER COMPLETE? YES CLEAR AXIAL THERMISTOR PROBE FAULT CONDITION RETURN IS AXIAL THERMISTOR PROBE OPEN? NO HAS 3 SEC TIMER EXPIRED YES NO IS AXIAL THERMISTOR PROBE SHORTED? YES NO FAULT ROUTINE RESET 3 SEC TIMER AXIAL THERMISTOR FAULT Page 55 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 10.4 ADC CATALOG #: ADC0007 MAIN DOOR DIAGNOSTICS START IS MAIN DOOR OPENED? YES IS CYCLE IN PROCESS? NO YES IS DRYER IDLE? RESET DOOR OPEN TIMER NO NO YES IS DRYER IN READY MODE? HEAT OFF DIAGNOSTICS NO MAIN DOOR OPEN TURN OFF FAN/ HOUR LOGGER, DRIVE NO YES MAIN DOOR OPEN SELECT TEMP TO RESTART IS TOP OR BOTTOM TEMP KEY PRESSED? RETURN IS A TEMP SELECTED? NO NO YES ENABLE WRINKLE GUARD RESTART IS DOOR OPEN TIMER ACTIVE? NO YES START DOOR OPEN TIMER CLOSE MAIN DOOR YES CONTINUE CYCLE COUNT DOWN TIME HAS THE MAIN DOOR BEEN OPENED FOR MORE THAN 10 SECS? YES DISABLE WRINKLE GUARD Page 56 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 10.5 ADC CATALOG #: ADC0007 LINT DOOR DIAGNOSITCS START IS LINT DOOR OPENED? IS CYCLE IN PROCESS? YES NO NO YES IS DRYER IDLE? NO HEAT OFF DIAGNOSTICS IS DRYER IN READY MODE? NO YES LINT ACCESS OPEN TURN OFF FAN/HOUR LOGGER, DRIVE SELECT TEMP TO RESTART NO YES YES LINT ACCESS OPEN IS A TEMP SELECTED? YES RESTART NO IS TOP OR BOTTOM TEMP KEY PRESSED? RETURN START LINT DOOR OPEN TIMER IS LINT DOOR TIMER ACTIVE? NO NO YES YES CONTINUE CYCLE COUNT DOWN TIME CLOSE LINT ACCESS HAS THE LINT DOOR BEEN OPENED FOR MORE THAN 15 SECS? YES RESET LINT CLEANING FREQUENCY TIMER Page 57 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 10.6 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 SAIL SWITCH OPEN START IS SAIL SWITCH OPEN? RESET SAIL SWITCH OPEN TIMERS NO IS HEAT REQUIRED? YES NO YES IS DRYER IN START UP IS 10 SECOND TIMER ACTIVE YES NO NO RETURN HEAT START TIMER NO YES NO HEAT OFF DIAGNOSTICS HAS THE 10 SECOND TIMER EXPIRED? IS 30 SECOND TIMER ACTIVE NO START TIMER YES YES HAS THE 30 SECOND TIMER EXPIRED? YES SHUT DOWN FAN/HOUR LOGGER OUTPUT VERIFY HEAT AND DRIVE ARE OFF FAULT RECORDING SAIL SWITCH OPEN FAULT, CHECK LINT AND MAIN DOOR...SELECT TEMP TO RESTART RESTART RETURN IS TEMP KEY PRESSED? YES NO Page 58 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 10.7 ADC CATALOG #: ADC0007 SAIL SWITCH CLOSED START IS SAIL SWITCH OPEN? YES RESET SAIL SWITCH CLOSED TIMERS YES IS 30 SECOND TIMER ACTIVE RETURN NO IS DRYER IN START UP MODE? NO START TIMER NO YES NO NO IS 30 SECOND TIMER ACTIVE? NO START TIMER PLEASE WAIT...START UP IN PROCESS YES HAS THE 30 SECONDS TIMER EXPIRED? PLEASE WAIT...RESTART UP IN PROCESS YES HAS THE 30 SECONDS TIMER EXPIRED? YES FAULT RECORDING SAIL SWITCH CLOSED FAULT...SELECT TEMP TO RESTART IS TEMP SELECTED YES NO RETURN RESTART Page 59 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 10.8 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 EXHAUST HIGH TEMP DIAGNOSTICS START IS DRYER IN READY MODE? YES RETURN NO IS DRYER IDLE? YES NO NO IS TEMP 20 ° ABOVE MAX SET POINT? YES IS EXHAUST TEMP TIMER ACTIVE? NO ACTIVATE 10 SEC TIMER NO RESET TEMP TIMER YES IS EXHAUST TEMP TIMER ACTIVE YES NO NO RETURN IS EXHAUST TEMP TIMER > 10 SEC? YES FAULT ROUTINE EXHAUST HIGH TEMP Page 60 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 10.9 ADC CATALOG #: ADC0007 ROTATION SENSOR DIAGNOSTICS START IS BELCO DRIVE OUTPUT OPTION ACTIVE NO YES IS ROTATION SENSOR OPTION ON? NO RETURN YES IS A DRIVE OUTPUT ACTIVE FOR THIS POCKET? NO YES RESET ROTATION SENSOR FAULT TIMER YES IS THERE A VALID ROTATION SENSOR PULSE? YES IS ROTATION SENSOR FAULT TIMER ACTIVE? NO CALCULATE RPM NO IS ROTATION SENSOR FAULT TIMER ACTIVE? NO START ROTATION SENSOR FAULT TIMER YES IS ROTATION SENSOR FAULT TIMER > 10 SEC? NO RETURN YES IS DRY CYCLE IN REVERSING MODE? YES REVERSING ROTATION SENSOR DIAGNOSTICS ARE BOTH DRIVE OUTPUTS DISABLED FOR THIS POCKET? NO NO FAULT ROUTINE YES ROTATION SENSOR Page 61 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 10.10 REVERSING ROTATION SENSOR DIAG START TURN OFF ACTIVE DRIVE OUTPUT DESIGNATE ACTIVE DRIVE OUTPUT AS BEING DISABLED. NON CATASTROPHIC FAULT INCREMENT DISABLED DRIVE COUNT ARE BOTH DRIVES FROM THIS POCKET DISABLED? YES RETURN NO IS STOP TIME TIMER ACTIVE? START STOP TIMER NO YES NO IS STOP TIMER > STOP TIME YES IS ANOTHER FAN OR DRIVE OUTPUT BEING TURNED ON FOR THE OTHER POCKET? YES WAIT 3 SECONDS NO NO WAS LAST ACTIVE DRIVE FORWARD? YES ASSIGN ACTIVE DRIVE TO FWD ASSIGN ACTIVE DRIVE TO REV TURN ON ACTIVE DRIVE TURN ON ACTIVE DRIVE RETURN Page 62 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 10.11 MODEL DIAGNOSTICS START IS DRYER A STEAM MODEL? NO YES IS SAIL SWITCH CLOSED? NO RETURN YES FAULT ROUTINE MODEL FAULT Page 63 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 10.12 HEAT OFF DIAGNOSTICS START TURN OFF HEAT WAIT xx MS IS HEAT RELAY RETURN SIGNAL ON? NO IS THIS POCKET’S GAS RETURN SIGNAL =120V? YES YES FAULT ROUTINE FAULT ROUTINE LATCHED HEAT RELAY FAULT BURNER RETURN VOLTAGE FAULT NO RETURN OPEN INTERPOSING RELAY RETURN Page 64 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART ADC CATALOG #: ADC0007 10.13 WATER PRESSURE DIAGNOSTICS START IS WATER PRESSURE SWITCH PRESENT? IS S.A.F.E. DISABLED? YES NO YES NO IS S.A.F.E. DISABLED? YES IS 1 MINUTE TIMER ACTIVE? RETURN NO NO START TIMER YES IS 5 MINUTE TIMER ACTIVE? NO START TIMER NO YES HAS THE 1 MIN TIMER EXPIRED? YES IS 5 MINUTE TIMER COMPLETE? YES CLEAR DISABLED MESSAGE CONDITION DISABLE S.A.F.E. NO IS JLA OPTION ON RETURN YES IS JLA LOCKOUT OPTION ON? NO NO NO F.S.S. DISABLED IS DRYER SET TO S.A.F.E. MESSAGE? YES APPEND JLA’S S.A.F.E. DISABLED MESSAGE TO READY MESSAGE YES APPEND JLA’S DISABLED MESSAGE TO READY MODE MESSAGE LOCKOUT DRYER DO NOT DISPLAY READY MESSAGE S.A.F.E. DISABLED APPEND S.A.F.E. DISABLED MESSAGE TO READY MESSAGE S.A.F.E. DISABLED, CONTACT JLA AT 01422 824688 S.A.F.E. DISABLED, CONTACT JLA AT 01422 824688 RETURN Page 65 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 11 ADC CATALOG #: ADC0007 FAULT HANDLING ROUTINES 11.1 FAULT ROUTINE START -TURN HEAT OFF -STOP CYCLE TIMER -START 3 MINUTE TIMER HEAT OFF DIAGNOSTICS FAULT RECORDING FAULTS THAT REQUIRE IMMEDIATE SHUT DOWN - ROTATION SENSOR FAULT FAULT DISPLAY -LATCHED HEAT RELAY -BURNER VOLTAGE RETURN IS FAULT CLEARED? NO DOES FAULT REQUIRE IMMEDIATE SHUT DOWN DOES BOTH FAN/ HOURLOGGER AND DRIVE NEED TO BE TURN OFF? YES NO NO IS TEMP > 100° F YES FAULT DISPLAY IS FAULT EXHAUST OR AXIAL PROBE FAULTS? NO YES YES NO IS 3 MINUTE TIMER COMPLETE NO YES YES SHUT DOWN FAN/HOUR LOGGER AND DRIVE YES TURN OFF DRIVE OUTPUT IS FAULT CLEARED? YES YES READY MODE IS THERE CREDIT AVAILABLE ON THE MACHINE? NO RESTART Page 66 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 11.2 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 FAULT DISPLAY ROUTINE START IS DRYER IN FREE OR OPL MODE YES NO OUT OF ORDER IS LO KEY PRESSED YES DISPLAY FAULT CODE MESSAGE NO NO NO IS ‘PAUSE KEY TIMER ACTIVE? YES IS PAUSE KEY PRESSED START PAUSE KEY TIMER NO YES RESET PAUSE KEY TIMER IS PAUSE KEY TIMER > 3 SEC? YES CLEAR FAULT RETURN Page 67 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 11.3 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 FAULT RECORDING START YES IS FAULT ON TOP POCKET? NO SHIFT TOP POCKET FAULT RECORD LOCATIONS AND STORE NEW FAULT IN LOCATION 1. SHIFT BOTTOM POCKET FAULT RECORD LOCATIONS AND STORE NEW FAULT IN LOCATION 1. STORE HOUR LOGGER VALUE AT TIME OF FAULT AND CYCLE INFORMATION STORE TRIGGER CODE FOR FSS TRIP STORE HOUR LOGGER VALUE AT TIME OF FAULT AND CYCLE INFORMATION STORE TRIGGER CODE FOR FSS TRIP DELETE ANY FAULT RECORDS OVER THE 5 LIMIT COUNT DELETE ANY FAULT RECORDS OVER THE 5 LIMIT COUNT RETURN Page 68 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 11.4 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 NON CATASTROPHIC FAULT ROUTINE START IS THERE AN ISSUE WITH A BAD COIN PULSE? INCREMENT TOP AND BOTTOM POCKET’S R7 YES NO RETURN IS FAULT BEING CALLED FROM TOP POCKET? YES IS THERE AN ISSUE WITH BURNER 1 RADIANCE SENSOR? YES NO INCREMENT BOTTOM POCKET’S R1 INCREMENT TOP POCKET’S R1 YES NO IS THERE AN ISSUE WITH BURNER 1 HEAT IGNITION? NO YES INCREMENT BOTTOM POCKET’S R2 INCREMENT TOP POCKET’S R2 YES NO IS THERE AN ISSUE WITH BURNER 2 RADIANCE SENSOR? YES INCREMENT BOTTOM POCKET’S R3 INCREMENT TOP POCKET’S R3 YES YES INCREMENT BOTTOM POCKET’S R4 INCREMENT TOP POCKET’S R4 YES IS THERE AN ISSUE WITH BURNER 2 HEAT IGNITION? NO YES INCREMENT BOTTOM POCKET’S R5 INCREMENT TOP POCKET’S R5 YES NO IS THERE AN ISSUE WITH REVERSE DRIVE OUTPUT? IS THERE AN ISSUE WITH BURNER 2 RADIANCE SENSOR? NO NO IS THERE AN ISSUE WITH FORWARD DRIVE OUTPUT? IS THERE AN ISSUE WITH BURNER 1 HEAT IGNITION? NO NO IS THERE AN ISSUE WITH BURNER 2 HEAT IGNITION? IS THERE AN ISSUE WITH BURNER 1 RADIANCE SENSOR? IS THERE AN ISSUE WITH FORWARD DRIVE OUTPUT? NO YES INCREMENT BOTTOM POCKET’S R6 INCREMENT TOP POCKET’S R6 NO YES IS THERE AN ISSUE WITH REVERSE DRIVE OUTPUT? NO RETURN Page 69 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 12 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 REGISTRATION HANDLING ROUTINES 12.1 REGISTRATION ROUTINE START IS JLA MODE ON NO YES IS JLA REGISTERED BIT SET? YES NO RETURN NO IS POCKET HOUR LOGGER > 4000 IS ADC REGISTERED BIT SET? YES NO YES REGISTRATION CYCLE COUNT DOWN IS POCKET HOUR LOGGER > 34600? NO RETURN LOCKOUT TIME= 4400 HOURS YES REGISTRATION CYCLE COUNT DOWN LOCKOUT TIME= 35000 HOURS Page 70 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 12.2 ADC CATALOG #: ADC0007 REGISTRATION CYCLE COUNT DOWN START INCREMENT CYCLE COUNT YES YES IS HOUR LOGGER > LOCKOUT TIME -300 IS HOUR LOGGER > LOCKOUT TIME -200 CYCLE COUNT LIMIT =4 NO IS HOUR LOGGER > LOCKOUT TIME 100 CYCLE COUNT LIMIT =3 NO IS HOUR LOGGER > LOCKOUT TIME YES NOTE: DISPLAY JLA’S CONTACT INFO IF JLA ROUTINE IS ON AND HOURLOGGER IS <4401 HOURS. CYCLE COUNT LIMIT =5 NO LOCK OUT KEYPAD CYCLE COUNT LIMIT =2 NO START 5 MINUTE TIMER AND IGNORE KEY PAD YES YES CYCLE COUNT=0 OUT OF ORDER. CONTACT AMERICAN DRYER CORPORATION AT WWW.AMDRY.COM AND USE SERIAL NUMBER 100000 TO OBTAIN A REGISTRATION CODE IS CYCLE COUNT = or > CYCLE COUNT LIMIT? NO SEE NOTE. RETURN IS 5 MINUTE TIMER COMPLETE? WARNING YOUR DRYER WILL LOCK-OUT IN 500 RUNNING HOURS. CONTACT AMERICAN DRYER CORPORATION AT WWW.AMDRY.COM AND USE SERIAL NUMBER 100000 TO OBTAIN A REGISTRATION CODE NO YES PRESS 'PAUSE' TO ENTER CODE, OR SELECT TEMPERATURE TO CONTINUE SEE NOTE NO NO HAS MESSAGE SCROLLED BY ONCE? YES REGISTRATION CODE YES IS STOP/ PAUSE KEY PRESSED? NO RETURN YES IS TEMP/ START KEY PRESSED? Page 71 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 12.3 ADC CATALOG #: ADC0007 DIRECT REGISTRATION ACCESS START IS JLA OPTION ON? YES IS TOP POCKET HOUR LOGGER ABOVE 4000? YES NO NO IS TOP POCKET HOUR LOGGER ABOVE 35600? NO RETURN YES NO HAS THE FOLLOWING KEY SEQUENCE -HI-LO-LO-LO-MED-MED-MED BEEN PRESSED WITHIN 3 SECONDS? YES RETURN REGISTRATION Page 72 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 12.4 ADC CATALOG #: ADC0007 REGISTRATION CODE START ENTER CODE ----------- IS JLA’s OPTION ON? YES IS JLA REGISTRATION BIT SET? NO YES - MULTIPLY SERIAL NUMBER x 17 - REVERSE ORDER OF RESULT FOR CODE. NO - REVERSE ORDER OF SERIAL NUMBER. - MULTIPLY SERIAL NUMBER x 14 FOR CODE YES YES DOES CODE ENTERED MATCH CALCULATED CODE? DOES CODE ENTERED MATCH CALCULATED CODE? NO NO SET ADC REGISTRATION BIT. SET JLA REGISTRATION BIT. REGISTRATION CYCLE COUNT DOWN RETURN REGISTRATION CYCLE COUNT DOWN RETURN Page 73 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 13 ADC CATALOG #: ADC0007 FIRE SUPPRESSION SYSTEM 13.1 FSS MONITORING START IS FIRE DETECTION OPTION ON? NO YES SAFE/FSS ACTIVATED YES WAS SYSTEM ACTIVATED AND NOT CLEARED? NO NO NO HAS HEAT BEEN OFF FOR MORE THAN 20 SEC? IS CONTROL IN A CYCLE YES NO HAS HEAT TURN ON A LEAST ONCE IN THIS CYCLE? YES YES THERMISTOR PROBE FSS MONITORING EXHAUST PROBE FSS MONITORING RETURN Page 74 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 13.2 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 THERMISTOR PROBE FSS MONITORING START RECORD THE LOWEST THERMISTOR PROBE TEMP IS THE THERMISTOR PROBE TEMP RISING ? NO RETURN YES IS THE THERMISTOR PROBE TEMP > 120° F? NO YES YES IS THE MINIMUM RECORDED THERMISTOR TEMP > OR = TO 120 °F? SUBTRACT LOWEST RECORDED THERMISTOR TEMP FROM CURRENT THERMISTOR PROBE TEMP NO SUBTRACT 120 FROM THE THERMISTOR PROBE TEMP IS TEMP RISE > OR = 50° F? NO YES FAULT RECORDING TRIGGER 2 ` SAFE/FSS ACTIVATED Page 75 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 13.3 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 EXHAUST PROBE FSS MONITORING START IS POCKET IN A DRYING CYCLE? NO YES HAS THE HEAT TURN ON ONCE? NO RETURN YES IS EXHAUST TEMP 25 ° F > SET POINT? NO YES FAULT RECORDING TRIGGER 1 SAFE/FSS ACTIVATED Page 76 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 13.4 ADC CATALOG #: ADC0007 S.A.F.E. / F.S.S. ACTIVATED HAS OVERALL TIMER EXPIRED? START IS CONTROL SET TO FSS? NO NO YES START TIMER IS OVERALL TIMER ACTIVE? NO YES S.A.F.E. ACTIVATED F.S.S. ACTIVATED TURN ON WATER VALVE OUTPUT IS OVERALL TIMER > 2 MINUTES? YES IS FSS PROBE CONSIDER TO BE A SHORT? YES IS FSS TEMPERATURE OVER TRIGGER POINT? NO NO YES NO START 15 SECOND TIMER YES NO IS OVERALL TIMER > 10 MINUTES? YES -TURN OFF WATER VALVE -OVERALL TIMER HAS EXPIRED NO HAS 15 SECONDS ELASPED? YES JOG TOP POCKET ACTIVE DRIVE FOR 1 SECOND AND STOP NO S.A.F.E. WAS ACTIVATED IS CONTROL SET TO FSS? NO YES IS JLA OPTION ON? YES F.S.S. WAS ACTIVATED JOG BOTTOM POCKET ACTIVE DRIVE FOR 1 SECOND AND STOP IS JLA LOCKOUT ON? NO S.A.F.E. WAS ACTIVATED, CALL JLA FOR INSPECTION AT 01422 824688 RESET 15 SECOND TIMER YES S.A.F.E. WAS ACTIVATED, CALL JLA FOR INSPECTION AT 01422 824688 OR YOUR DRYER WILL LOCKOUT IN 30 RUNNING HOURS IS FIRE SUPPRESSION FAULT CLEARED? YES NO FIRE SUPPRESSION CLEAR. ` RETURN Page 77 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 13.5 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 FIRE SUPPRESSION CLEAR START IS PAUSE KEY PRESSED? NO RETURN YES START 3 SECOND TIMER YES IS 3 SECOND TIMER EXPIRED? NO IS PAUSE KEY STILL PRESSED? NO YES CLEAR FIRE SYSTEM TRIGGER IS DRYER IN READY MODE NO SELECT TEMP TO RESTART NO YES IS TEMP SELECTED YES READY MODE RESTART Page 78 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 14 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 MAINTENANCE ROUTINES 14.1 TEST BOOTH ROUTINE START 1. TEST WATER VALVE 2. ENTER SERIAL NUMBER IS TEST WATER VALVE SELECTED? YES NO YES NO IS ENTER SERIAL NUMBER SELECTED? ENTER SERIAL NUMBERYES PRESS AND HOLD MED KEEY TO ACTIVATE WATER VALVE SEE PROGRAM MENU DOCUMENT NO NO IS MED KEY PRESSED? IS PAUSE KEY PRESSED? YES POWER UP ROUTINE YES IS PAUSE KEY PRESSED? NO ACTIVATE WATER VALVE Page 79 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 14.2 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 LINT CLEANING FREQUENCY ROUTINE START IS LINT CLEANING FREQUENCY SETTING = 0? YES NO IS LINT CLEANING FREQUENCY TIMER > LINT CLEANING FREQUENCY SETTING? NO RETURN YES APPEND CLEAN LINT TO DRYING MODE SCREEN NO IS CONTROL IN READY MODE YES IS LINT CLEANING FREQUENCY TIMER > LINT CLEANING FREQUENCY SETTING + 2 HOURS? YES NO APPEND CLEAN LINT TO READY MESSAGE READY INSERT $0.25 TO START...CLEAN LINT CLEAN LINT IGNORE ALL KEYPAD COMMANDS, EXCEPT FOR UP ARROW AND STOP KEY FOR OPL MODE TO ENTER PROGRAM SETTINGS. RETURN Page 80 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 15 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 MARKETING ROUTINES 15.1 ADC WEB ADDRESS START IS ON TIME HOURLOGGER > 40000 NO RETURN YES IS POCKET IN A DRYING CYCLE? YES NO IS WEB ADDRESS TIMER ACTIVE NO START WEB ADDRESS TIMER YES IS WEB ADDRESS TIMER > 10 MINUTES? NO YES RESET WEB ADDRESS TIMER THIS TIMER IS RESET WHEN NOT IN “READY MODE” LOCKOUT KEY PAD WHILE MESSAGE SCROLLS BY ONCE AMERICAN DRYER CORP. WWW.AMDRY.COM ENABLE KEYPAD Page 81 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 15.2 ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 BUZZER START IS KEY PRESSED? YES BEEP 1 TIME FOR 1 ms YES BEEP 1 TIME FOR 1 ms YES BEEP 1 TIME FOR 1 ms YES BEEP 1 TIME FOR 1 ms YES BEEP 1 TIME FOR 1 ms YES BEEP 1 TIME FOR 1 ms YES BEEP 1 TIME FOR 1 ms YES BEEP 1 TIME FOR 1 ms NO IS CONTROL ENTERING PAUSE? NO IS CONTROL RESTARTING FROM PAUSE? NO IS CONTROL AT WRINKLE GUARD START UP? NO IS BUZZER SETTING SET TO NO BUZZ? NO IS CONTROL AT WRINKLE GUARD SHUT DOWN? YES NO IS CONTROL AT END OF CYCLE? NO IS CONTROL ENTERING FAULT ROUTINE? NO IS CONTROL IN FSS? RETURN Page 82 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC ENGINEERING CONTROLS GROUP ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART 16 IF ADC CATALOG #: ADC0007 AUTO CYCLE The table below describes which value to use for the wet hit measurement period, TIME0 search period, and to determine which damp / dry rule table to use. These values will be based on the Dry Temp selection and the heat type. DRY TEMP In deg F 160 - 156 155 - 151 150 - 141 140 - 126 125 - 100 160 - 156 155 - 151 150 - 141 140 - 126 125 - 100 160 - 156 155 - 151 150 - 141 140 - 126 125 - 100 + HEAT TYPE ELECTRIC ELECTRIC ELECTRIC ELECTRIC ELECTRIC STEAM STEAM STEAM STEAM STEAM GAS GAS GAS GAS GAS THEN WET HIT MEASUREMENT PERIOD 5 minutes 5 minutes 5 minutes 5 minutes 5 minutes 5 minutes 5 minutes 5 minutes 5 minutes 5 minutes 5 minutes 5 minutes 5 minutes 5 minutes 5 minutes + TIME0 SEARCH PERIOD 120 seconds 120 seconds 120 seconds 120 seconds 120 seconds 120 seconds 120 seconds 120 seconds 120 seconds 120 seconds 60 seconds 120 seconds 60 seconds 120 seconds 60 seconds + DAMP DRY RULE TABLE PL rule table Heavy Normal Perm Press Perm Press Delicate Heavy Normal Perm Press Perm Press Delicate Heavy Normal Perm Press Perm Press Delicate *changed wet hit measurement for gas 125-100º from 4 minutes. 16.1 AUTO CYCLE DRYNESS LEVEL The table below describes the amount of time added to the drying cycle depending on the dry level selected: ADC DRY LEVEL SETTING XDRY DRY FIN(ISHING) PL/ADC DRY LEVEL SETTING MORE NORMAL LESS ADD-ON TIME EQUALS Add-On Dry + (Add-On Dry – Add-On Damp) Add-On Dry Add-On Damp 16.2 INITIAL ESTIMATED TIME REMAINING The table below shows the initial estimated time remaining for a dry temp selected: DRY TEMP In deg F 160 - 156 155 - 151 150 - 141 140 - 126 125 - 100 ESTIMATED TIME REMAINING In minutes TBD TBD TBD TBD TBD Page 83 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION ADC PHASE 8.4.1 CONTROL BOARD SOFTWARE FLOWCHART ADC ENGINEERING CONTROLS GROUP ADC CATALOG #: ADC0007 16.3 ESTIMATED TIME REMAINING FIVE MINUTES INTO DRYING CYCLE The table below shows which table to use in the fuzzy logic control for estimated time after NUM25_27 has been determined when a particular dry temp is selected. IF DRY TEMP In deg F 160 - 156 155 - 151 150 - 141 140 - 126 125 - 100 THEN USE ESTIMATED TIME RULE TABLE PL Est_Rule table Heavy Normal Perm_Press Perm_Press Delicate 16.4 EMPTY DRUM DETECTION The table below represents the minimum amount of run time for a dry temp selected. DRY TEMP In deg F 160 - 156 155 - 151 150 - 141 140 - 126 125 - 100 MINIMUM RUN TIME In minutes 10 10 10 20 10 Page 84 of 84 CONFIDENTIAL: PROPRIETARY PROPERTY OF AMERICAN DRYER CORPORTATION