Preview only show first 10 pages with watermark. For full document please download

Adcp-90-360: 23-inch Fiber Management Tray (fmt) 24

   EMBED


Share

Transcript

ADCP-90-360 ISSUE 1 DECEMBER 2006 23-Inch Fiber Management Tray (FMT) 24-Position Faceplate Termination Installation Instructions 3 CABLE PREPARATION INCOMING SPLICE CABLE 30 IN. PLACE YELLOW SPLIT TUBE OVER FLARE TUBE AND SECURE TO FLARE TUBE WITH CABLE TIE 79 IN. 25 IN. For dimensions, refer to drawing number 1388636. OVAL TUBING BREAKOUT FIBER INSIDE TRAY BLU ORG GRN BRN SLT WHT Route incoming splice cable, shown in YELLOW for clarity, as shown. After completing splicing, replace splice tray cover and use Velcro (provided) to secure splice tray to panel. RED BLK YEL VIO ROS AQU FIBER POSITION / COLOR L3 INCHES 13 14 15 16 17 18 19 20 21 22 23 24 27 BLU ORG GRN BRN SLT WHT RED BLK YEL VIO ROS AQU PIGTAIL FIBERS FROM ADAPTERS TO SPLICE TRAY Route fibers from adapters to the splice tray as shown. Note: Top 12 adapters to the fanout (labeled 2) are shown in RED for clarity, fibers from bottom 12 adapters (labeled 1) are shown in BLUE. Two 12-fiber ribbons, enclosed in an oval tube, exit the fanout and are routed to the splice tray. The oval tube is shown in YELLOW, for clarity. ROUTE OVAL TUBE 1 1/2 TIMES AROUND OUTSIDE OF SPLICE TRAY AS SHOWN. TRAY LOCK TIE-DOWN LANCES (2 UNDER TRAY). USE VELCRO (PROVIDED) TO SECURE SPLICE TRAY TO PANEL. PIGTAIL ROUTING FROM ADAPTERS TO SPLICE TRAY (SEE STEPS 1 AND 2) 5 INCOMING PATCH CORD ROUTING Route incoming PATCH cables, shown in YELLOW for clarity, as shown. 2 1 1 1 1 2 2 1 1 1 1 1 1 1 FIBER POSITIONS: 23 (TOP); 24 (BOTTOM) REFER TO TABLE 2 21746-A OVAL TUBE PLACED OVER TWO 12-FIBER RIBBONS PIGTAIL FIBERS (24) FROM ADAPTERS FANOUT DETAIL (ISO VIEW) 1389856 REV A 1 2 KEY: RED = FIBERS FROM ADAPTERS LABELED "2" BLUE = FIBERS FROM ADAPTERS LABELED "1" YELLOW = OVAL TUBE INSTALLED OVER RIBBONS ORANGE = BREAKOUT FIBER INSIDE OF TRAY 2 2 INCOMING PATCH CORD CABLES (SEE STEP 5) REFER TO TABLE 2 "FANOUT TABLE" FOR CONNECTOR ASSIGNMENTS 2 2 FIBER POSITIONS: 1 (TOP); 2 (BOTTOM) REFER TO TABLE 2 2 USE LACING TO SECURE CABLE TO SPLICE TRAY 2 2 FANOUT 12 2 INCOMING SPLICE CABLES (SEE STEPS 3 AND 4) TO ADAPTERS 11 2 The Termination/Storage Panel is mounted vertically in a cabinet. Cable routing is shown in a top view for clarity. 10 1 2 3 1 VELCRO 32 30 2 INCOMING SPLICE CABLE ROUTING 1 1 1 4 1 CABLE CLAMP KIT L3 INCHES FIBER POSITION / COLOR 4 5 6 7 8 9 1 4 FANOUT TABLE (FANOUT CATALOG NUMBER: "FGX") 1 #12 LOCKWASHER TABLE 2. FANOUT TABLE 48.0" ±2.0" 36 IN. +1.5/-0.0 IN. 2 4 OVAL TUBING LENGTH L3" +0.0/-1.5 SEE TABLE 2 2 12-24 SCREW CABLE TIE Order cable assembly (refer to Table 5 on reverse side) or prepare cable as shown. 2 QTY CABLE CLAMP 2 NOTE: DESCRIPTION FLARE TUBE 2 TABLE 1. HARDWARE SHIPPED WITH PANEL 1 PIGTAIL CABLE PREPARATION TUBING OVER RIBBON 2 TERMINATION SPLICE PANEL BARE RIBBON FIBER Danger: ! Infrared radiation is invisible and can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not look directly into the optical adapters of the adapter packs. Exposure to invisible laser radiation may result. A protective cap or hood MUST be immediately placed over any radiating adapter or optical fiber connector to avoid the potential of dangerous amounts of radiation exposure. This practice also prevents dirt particles from entering the connector and adapter . © 2006, ADC Telecommunications, Inc. ADCP-90-360 ISSUE 1 DECEMBER 2006 1 TERMINATION STORAGE PANEL TABLE 3. HARDWARE SHIPPED WITH PANEL NOTE: DESCRIPTION QTY 12-24 SCREW 4 #12 LOCKWASHER 4 CABLE CLAMP KIT 1 VELCRO 2 The Termination/Storage Panel is mounted vertically in a cabinet. Cable routing is shown in a top view for clarity. ADC TELECOMMUNICATIONS, INC PO BOX 1101, MINNEAPOLIS, MN 55440-1101, USA ATTN: TECHNICAL ASSISTANCE CENTER: 1-800-366-3891, EXT: 73475 CABLE PREPARATION Order cable assembly (refer to Table 5) or prepare cable as shown. BREAKOUT LENGTH 89 IN. L3" +0.0/-1.5 SEE TABLE 2 TABLE 4. FANOUT TABLE PLACE YELLOW SPLIT TUBING OVER FLARE TUBE AND SECURE TO FLARE TUBE WITH CABLE TIE FANOUT TABLE (FANOUT CATALOG NUMBER: "FGX") RIBBON L3 NUMBER INCHES 25 IN. 32 30 1 FLARE TUBE PROTECTIVE TUBING CABLE CLAMP 2 3 FIBER POSITION / COLOR 4 5 6 7 8 9 10 11 12 BLU ORG GRN BRN SLT WHT RED BLK YEL VIO ROS AQU FIBER POSITION / COLOR RIBBON L3 NUMBER INCHES 1 2 3 4 5 6 7 8 9 10 11 12 2 27 BLU ORG GRN BRN SLT WHT RED BLK YEL VIO ROS AQU FANOUT TO ADAPTERS 1 CABLE TIE OSP RIBBON CABLE ASSEMBLY 2 FIBERS FROM ADAPTERS TO CUSTOMER EQUIPMENT Route fibers from adapters as shown. Note: Top 12 adapters to the fanout clip (labeled 2) are shown in RED for clarity, fibers from bottom 12 adapters (labeled 1) are shown in BLUE. Oval tubes shown in Yellow for clarity. 3 INCOMING PATCH CORD ROUTING Route incoming patch cords, shown in YELLOW for clarity, as shown. 2 2 2 2 2 1 2 1 1 1 1 1 ROUTE OVAL TUBE 1 1/2 TIMES AROUND RADIUS LIMITERS AS SHOWN. NOTE: FIBERS FROM ADAPTERS TO CUSTOMER EQUIPMENT (SEE STEPS 1 AND 2) ONE 12-FIBER RIBBON SHOWN ROUTED FOR CLARITY. ROUTE 2ND 12-FIBER RIBBON IN SAME MANNER. 21747-A 2 2 2 2 2 2 1 1 1 1 1 1 TABLE 5. TERMINATION SPLICE AND TERMINATION STORAGE PANEL CATALOG NUMBERS AND DECRIPTIONS OVAL TUBE PLACED OVER EACH 12-FIBER RIBBON FIBER POSITIONS: 23 (TOP); 24 (BOTTOM) REFER TO TABLE 4 DESCRIPTION FMX-ALC-LPSTORE Slack storage panel for use with vertical FMT panel. OSA-7CHRA000FFMB 24-fiber OSP armored ribbon cable assembly with FMT LP breakout. Includes ground lug. "000" = length in feet. FST-M-MT FMT splice tray with mass fusion splice chip. IFC-7/0FP006.2F-FGX 24-fiber ribbon pigtail with SMSC connectors FMT-ACCCLMP07 FMT cable clamp kit, 0.25" standoff from frame. FL2-ACC056 OFS style grounding kit FGS-MFTY-200F Yellow split tube kit, 200 ft. FANOUT DETAIL (2) (ISO VIEW) 12 FIBERS FROM ADAPTERS 1389856 REV A ADC CATALOG NUMBER STORAGE INCOMING PATCH CORD CABLES (SEE STEP 3) REFER TO TABLE 4 "FANOUT TABLE" FOR CONNECTOR ASSIGNMENTS SPLICE FIBER POSITIONS: 1 (TOP); 2 (BOTTOM) REFER TO TABLE 4 © 2006, ADC Telecommunications, Inc.