TrueNet® Copper Ten Augmented Category 6 24 and 48 Port Patch Panel
1
2
INSTALL PANEL The panel and cable manager are designed to fit into 19 inch rack widths. Install the panel into a rack as shown below.
PANEL DIMENSIONS
Installation and Cable Routing Instructions
24 POSITION PANEL (CAT. # PP24AC6AT)
ADCP-92-092 · Issue 2 · 1/09
48 POSITION PANEL (CAT. # PP48AC6AT)
TOOLS REQUIRED AND PARTS LIST
H: 1.72 IN. (4.37 CM) W: 19.0 IN. (48.1 CM) D: 1.2 IN. (14.0 CM) H: 3.48 IN W: 19.0 IN. D: 1.2 IN.
ANGLED BEZELS (SHOWN IN FLUSH POSITION)
To terminate modular jacks, use either standard 110 type impact tool punch down tool.
PARTS LIST QUANTITY 24-PORT 1 1 24
SMALL, FLAT SCREW DRIVER
4 4 8 4
DESCRIPTION 48-PORT 1 COPPER TEN 24 PORT PANEL 2 COPPER TEN WIRE MANAGER 48 ICON 1 THROUGH 6, BLACK PAPER DESIGNATION LABEL 8 8 16 8
48 POSITION PANEL
PLASTIC LABEL COVER RACK SCREW WRITE-ON DESIGNATION STRIP
FRONT VIEW
PHILLIPS SCREWDRIVER STANDARD 110 TYPE IMPACT TOOL
3
!
install telephone equipment in a wet location or during a lightning storm. Warning: Never When installing or modifying telephone lines, disconnect lines at the network interface before working with uninsulated lines or terminals.
12-24 SCREW (4)
24 POSITION PANEL
PUNCH DOWN TERMINATION CABLES Remove 1 inch of cable jacket and fan out all four twisted pairs. Use a standard 110 type impact tool to terminate cables at the rear of the punch down panels. For best results, maintain twist in wires up to termination point.
NOTE: TIA/EIA-568-B WIRING CONFIGURATION IS SHOWN IN THIS ILLUSTRATION. FOR TIA/EIA-568-A WIRING CONFIGURATION, REFER TO COLOR LABELS ON PANEL.
MAINTAIN TWIST IN WIRES UP TO TERMINATION POINT
1.0 IN.
USE 110 PUNCH DOWN TOOL AND TERMINATE EACH WIRE
REAR VIEW
22891-B
1461447 Rev A
ADC and ADC Telecommunications are registered trademarks of ADC Telecommunications, Inc.
2009©, ADC Telecommunications, Inc.
4
Unlock CAM Screws (2) and Rotate Bezels
5
After all jacks have been terminated, use straight screwdriver and 1/4 turn CAM screws to unlock bezels. Rotate bezels corresponding to patch cord flow, as shown, and lock CAM screws.
Install Wire Manager Use 12-24 screws (4) and install wire manager between top and bottom rows of cables.
CAM SCREW IN UNLOCKED POSITION
REAR VIEW CAM SCREW IN LOCKED POSITION
6
1/4 TURN CAM SCREWS (2) TO UNLOCK BEZEL
ROTATE BEZELS. NOTE: BEZELS ARE ROTATED IN THE DIRECTION OF PATCH CORD FLOW.
LOCK CAM SCREW ON BOTH SIDES OF BEZEL. NOTE: BEZEL ON RIGHT NOT SHOWN, FOR CLARITY.
Dress Cables into Cable Manager (Recommended) Route patch cords installed in two rightmost bezels toward the right. Route patch cords installed in two leftmost bezels toward the left.
FIT CABLES INTO WIRE MANAGER
8
7
Install Designation Labels and Icons Place plastic label cover over designation label and slide both into each bezel from either side. Or snap write-on designation strip into each bezel. Determine circuit designation and snap either phone or computer icon into each location.
Install Patch Cords (Recommended) Route patch cords installed in two rightmost bezels toward the right. Route patch cords installed in two leftmost bezels toward the left. DESIGNATION LABEL
WRITE-ON DESIGNATION STRIP
PLASTIC LABEL COVER
FRONT VIEW
REAR VIEW