Transcript
Addendum No. 2 July 18, 2014 Project:
Track - Sports Performance Enhancement / DakotaDome Complex Renovations University of South Dakota Vermillion, South Dakota OSE Project #: R0612--02X / TRACK
Architect: Architecture Incorporated Letting:
Thursday, July 24, 2014 2:30 PM CST Office of the State Engineer Joe Foss Building 523 East Capitol Pierre, South Dakota 57501
Scope of this Addendum: To all bidders and all others to whom drawings and specifications have been issued by Architecture Incorporated. Acknowledge receipt of this addendum by listing its number and date in the bidders Form of Proposal. Failure to do so may subject bidder to disqualification. This Addendum forms a part of the Contract Documents. It modifies them as follows: GENERAL ITEMS:
1) SPECIFICATION SECTION 087100 – DOOR HARDWARE: a) Delete Part 2.7.
2) SPECIFICATION SECTION 131251 – PREFABRICATED PRESS BOX: a) Part 1.2, Article B – add the following Section “4. Division 08 Section “Door Hardware” for requirements of door hardware provided in this section. b) Part 2.3, Article G, Section 12 – Change this to read “At pre-fabricated press box serving track field, provide two (2) telecommunications drops at each of two (2) locations inside the press box; locate adjacent to press box exterior doors and coordinate with location of wireless internet transmitters. Route telecommunications cabling concealed to location of telecommunications rack indicated on the Drawings. Provide raceways through press box exterior walls for Owner’s connection of exterior weatherproof antennae associated with wireless internet transmitters. Leave 20’-0” excess spool of each telecommunications cable for termination by electrical contractor. Provide 12” x 12” x 4”-deep flush box below counter at sound system control console with 2” concealed conduit back to sound rack.”
1 of 5
c) Part 2.3, Article G, Section 15 – Change this to read “At pre-fabricated press box serving soccer field, provide two (2) telecommunications drops at each of two (2) locations inside the press box; locate adjacent to press box exterior doors and coordinate with location of wireless internet transmitters. Route telecommunications cabling concealed to location of telecommunications rack indicated on the Drawings. Provide raceways through press box exterior walls for Owner’s connection of exterior weatherproof antennae associated with wireless internet transmitters. Leave 195’-0” excess spool of each telecommunications cable for extension and termination at the track field press box telecommunications rack by electrical contractor. Provide 12” x 12” x 4”-deep flush box below counter at sound system control console with 2” concealed conduit back to sound rack.”
3) SPECIFICATION SECTION 321216, 2.3 HOT MIX ASPHALT: a) Paragraph D – the Asphalt Binder Course shall be either Class E1 or E2 or Class G1 or G2. The Asphalt Top Coat shall be either Class E2 or Class G2 as per the South Dakota Department of Transportation Standard Specifications for Road and Bridges. b) The asphalt concrete mix design shall be submitted to the Engineer and the Synthetic Surfacing Contractor for approval a minimum of two (2) weeks prior to installation. 4) DRAWING SHEET 2.1: a) The existing irrigation system is 6” diameter from the well house and reduces to 4” diameter at the location indicated on attached supplemental civil drawing SCD-2 dated July 18, 2014. The existing irrigation system can supply 75 psi of pressure. 5) DRAWING SHEET 2.2: a) UTILITIES: Some of the utilities within the project limits belong to the University of South Dakota. The Contractor shall notify the USD Project Manager and SD One Call to have all the utilities located within the project limits. b) TOPSOIL: Excess topsoil shall remain the property of the University and be stockpiled at 1996 N. University Street, Vermillion, South Dakota. 6) DRAWING SHEETS 2.3: a) The 6 trees identified to be relocated shall be relocated in the space defined by the south side of the gas easement, south edge of future parking turn-around & future walk and the north side of new fence to the north and east of the track (see drawing sheet 2.4). 7) DRAWING SHEET 2.4: a) Dimension within the jumping events area should be 55.83’ in lieu of 55.83”. 8) DRAWING SHEETS 2.10: a) The water service layout to the two (2) drinking fountains is revised to utilize the existing domestic water meter in the well house/storage building at the south end of the complex. The following revisions are hereby made to the Utility Plan:
2 of 5
Delete the following Water Service Notes from Sheet 2.10: Node W17: 2” x 1” Tee (Delete) Node W18: 1” x 8’ P.E. Water Service (Delete) Node W19: 18” Dia. Meter Box & Water Meter (Delete) Node W24: 1” x 1” Tee, Backflow Preventer Device, 1” x 140’ P.E. Water Services (Delete) Connect to the existing 1” water service within the well house and revise the water service connection to the quick connect valve box at Node W25. See attached supplemental civil drawing SCD-1 dated July 17, 2014 for water service revisions and added Water Service Notes. 9) DRAWING SHEET 2.22: a) 4’ dimension at the north end of the jumping events was intended to identify the width of the sidewalk to the south of it. 10) DRAWING SHEET 4.1: a) Details A and 11 – windows at the press box to be type ‘A’. 11) DRAWING SHEET 4.2: a) Detail A – windows at the press box to be type ‘A’. 12) DRAWING SHEET 4.3: a) Detail 3 – counter shall have a positive slope to the exterior of the opening for drainage. 13) DRAWING SHEET 5.4: a) Delete reference to ‘Progress Print Not for Construction’ stamp on this sheet. 14) GENERAL CLARIFICATIONS: a) Addendum #1 drawings attachments have been reincluded into this addendum as there had been reports of missing the attachments. 15) GENERAL CLARIFICATIONS: a)
The schedule has been reattached for reference. The track surfacing needs to be completed by the beginning of September 2015. The track subcontractor, procured by The State of South Dakota, needs 4 weeks to install the track surfacing.
16) GENERAL CLARIFICATIONS: a)
In the base bid, sodding is required on the inside of the track and under the soccer playing field. All other areas should include seeding.
17) GENERAL CLARIFICATIONS: a) Mortenson / Fiegen will hold all contracts and provide Construction Management Services as identified in the Contract Documents 18) GENERAL CLARIFICATIONS: 3 of 5
a) Bidding contractor shall provide coordination amongst the respective subcontractors on the project but there will be no 3D modeling requirement for the Track and Soccer Complex.
19) GENERAL CLARIFICATIONS: a) NCAA requirements allow for a maximum inclination of the track to be 1.0%. The target design slope of 0.8% is specified in consultation for the Synthetic Track Surfacing Contractor to insure that the 1.0% maximum slope is not exceeded. 20) GENERAL CLARIFICATIONS: a) NCAA requirements for the various field events that occur in the D-zones (1/2 moon areas) of the track allow for a maximum slope of 0.4%. 0.4% is the maximum allowable slope in the D-zones for tracks constructed to NCAA/IAAF standards. 21) GENERAL CLARIFICATIONS: a) A supplemental drawing indicating where existing 6” irrigation line transitions to a 4” irrigation line will be provided in Addendum #2. Addendum #2 will also indicate that the existing irrigation system provides 75 psi of pressure.
MECHANICAL ITEMS: 19) DRAWING SHEET 8.3: a) REGISTER – GRILLE – DIFFUSER SCHEDULE – add the following note: i)
“4. Acceptable manufacturers, Krueger, Price, Titius and Nailor.”
ELECTRICAL ITEMS: 20) SPECIFICATION SECTION 269090 – SOUND AND MUSIC SYSTEMS: a) This section, including cut sheets and sample bill of material are attached at the end of this addendum. Sample bill of materials is included to describe minimum features, include all components necessary for a complete turnkey sound and music system – even if not listed on the sample bill of materials. 21) SPECIFICATION SECTION 268080 – TELECOMMUNICATIONS SYSTEMS: a) Reference paragraph 2.10.A.2, revise “OM1” to “OM3”. Reference paragraph 2.10.A.7, revise “OptiSpeed” to “LazrSpeed”. 22) DRAWING SHEET 9.2: a) Revise and add sound systems indicated on reissued sheet, attached at end of addendum.
4 of 5
b) Reference plans 2/9.2 and 3/9.2 for Electrical Under Bleachers. As clarification, conduit indicated on 2/9.2 (base bid) for future underground wiring with keynote #18 is also required on 3/9.2 (alternate #1). 23) DRAWING SHEET 9.3: a) Revise and add sound systems indicated on reissued sheet, attached at end of addendum. b) Reference keynotes #10 and #11. Add “Nominal 72-inches long x 36-inches wide x 36-inches deep. Provide 12-inches crushed rock base for setting boxes. Provide lacing bars inside boxes for strapping cables. 24) DRAWING SHEET 9.6: a) Add note at timeclocks ‘TCA’ and ‘TCC’ – “Provide Intermatic E1600 Series digital astronomic 20A timer flush in wall with engraved plaque above. Program to Owner’s schedule.” 25) DRAWING SHEET 9.7: a) Revise press box requirements and timeclock ‘TCB’ requirements as indicated on reissued sheet, attached at end of addendum.
GENERAL APPROVALS: The following material or equipment furnished by the manufacturer's listed, may be substituted as equivalent providing that each item, material, and piece of equipment conforms to the design and requirements of the specifications. SECTION 131250
ITEM Permanent Grandstands
MANUFACTURER Sturdisteel Holloway
131251
Prefabricated Press Box
Sturdisteel Holloway
END OF ADDENDUM
5 of 5
SECTION 269090 – SOUND AND MUSIC SYSTEMS
PART 1 - GENERAL
1.1 A.
1.2 A.
RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
SUMMARY Section Includes: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11.
B.
Project Includes: 1. 2. 3.
1.3
Digital signal processors. Power amplifiers. Microphones. Wireless microphone systems. Hearing assist transmitter. Control consoles. Equipment racks. Exterior rated loudspeakers. Speaker mounting poles and mounting brackets. Conductors and cables. Pathways.
Turnkey sound and music system covering track infield and track spectator bleachers. Turnkey sound and music system covering competition soccer field and soccer spectator bleachers. Track sound and music system is independent of competition soccer field sound system.
DEFINITIONS
A.
Channels: Separate parallel signal paths, from sources to loudspeakers or loudspeaker zones, with separate amplification and switching that permit selection between paths for speaker alternative program signals.
B.
Zone: Separate group of loudspeakers and associated supply wiring that may be arranged for selective switching between different channels.
1.4
ACTION SUBMITTALS
A.
Product Data: For each type of product.
B.
Shop Drawings: Power, signal, and control wiring. 1. 2.
Include scaled floor plans, site plans, elevations, sections, and attachment details. Include details of equipment assemblies. Indicate dimensions, weights, required clearances, method of field assembly, components, and location and size of each field connection.
SOUND AND MUSIC SYSTEMS (122090)
269090-1 2014 by FEI
3. 4. 5.
Console and control panel layouts. Rack arrangements. Wiring Diagrams: For power, signal, and control wiring. a. b. c.
1.5
Identify terminals to facilitate installation, operation, and maintenance. Single-line diagram showing interconnection of components. Cabling diagram showing cable routing.
INFORMATIONAL SUBMITTALS
A.
Qualification Data: For installer.
B.
Field quality-control reports.
1.6 A.
CLOSEOUT SUBMITTALS Operation and Maintenance Data: For sound and music systems to include in operation and maintenance manuals. 1.
In addition to items specified in Division 01, include the following: a. b. c.
1.7 A.
List of tools and replacement items recommended to be stored at Project for ready access. Include part and drawing numbers, current unit prices, and source of supply. Operating instructions laminated and mounted adjacent to operating console location. Training plan.
QUALITY ASSURANCE Installer Qualifications: Manufacturer's authorized representative who is trained and approved for installation of units required for this Project. 1.
Personnel certified by NICET as Audio Systems Level III Technician.
PART 2 - PRODUCTS
2.1
MANUFACTURERS
A.
Source Limitations: See bill of materials and product data attached to end of specification, which is the basis of design. Equivalent manufacturers are acceptable with prior approval of the Engineer. Provide all components and accessories for complete turnkey systems, attached bill of material and product data are intended to describe general system scope and may not include all components necessary. Cable lengths and required conductor gauge size shall be calculated from site plans.
B.
Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application.
C.
Comply with NFPA 70.
SOUND AND MUSIC SYSTEMS (122090)
269090-2 2014 by FEI
2.2 A.
FUNCTIONAL DESCRIPTION OF SYSTEM System Functions: 1. 2. 3. 4.
2.3
Selectively connect any zone to any available signal channel. Selectively control sound from microphone outlets and other inputs. "All-call" feature shall connect the all-call sound signal simultaneously to all zones regardless of zone or channel switch settings. Reproduce high-quality sound that is free of noise and distortion at all loudspeakers at all times during equipment operation including standby mode with inputs off; output free of nonuniform coverage of amplified sound.
SYSTEM DESCRIPTION
A.
Compatibility of Components: Coordinate component features to form an integrated system. Match components and interconnections for optimum performance of specified functions.
B.
Equipment: Comply with UL 813. Equipment shall be modular, using solid-state components, and fully rated for continuous duty unless otherwise indicated. Select equipment for normal operation on input power usually supplied at 110 to 130 V, 60 Hz.
C.
Equipment Mounting: Where rack, cabinet, or console mounting is indicated, equipment shall be designed to mount in a 19-inch housing complying with EIA/ECA-310-E.
D.
Weather-Resistant Equipment: Listed and labeled by a qualified testing agency for duty outdoors and in wet locations.
2.4
SIGNAL PROCESSORS
A.
Automatic Microphone Mixer: Two-band equalizer and three logic terminals on each input channel. Automatic gain adjustment as additional microphones are added.
B.
Digital Signal Processor: 4 line inputs, 8 independent mix outputs.
C.
Programmable Logic: 20 programmable logic inputs and serial communications.
2.5
POWER AMPLIFIERS
A.
Mounting: Rack.
B.
Output Power, Speakers Serving Field: Two (2) channels, 700W per channel at 8 ohms, 1100W per channel at 4 ohms, 1700W per channel at 2 ohms.
C.
Output Power, Speakers Serving Spectator Bleachers: Two (2) channels, 550W per channel at 8 ohms, 900W per channel at 4 ohms, 1500W per channel at 2 ohms.
D.
Total Harmonic Distortion (SMPTE-IM): Less than 0.02 percent.
E.
Minimum Signal-to-Noise Ratio: 106 dB, at rated output.
F.
Frequency Response: Within plus or minus 0.2 dB from 20 to 20,000 Hz.
SOUND AND MUSIC SYSTEMS (122090)
269090-3 2014 by FEI
G.
Controls: On-off, input levels, and low-cut filter.
H.
Input Sensitivity: Matched to digital signal processor.
2.6 A.
MICROPHONES Sports Microphone: 1. 2. 3. 4. 5. 6.
B.
Wireless Microphone System: 1.
2.7 A.
2.8 A.
2.9
Type: Dynamic, with omnidirectional polar characteristic. Impedance: 150 ohms. Frequency Response: Uniform, 80 to 20,000 Hz. Output Level: Minus 56 dB. Connectors: Wireless type. Mounting: Sports announcer’s stand with integral-locking, press-to-talk switch.
Handheld transmitter with matching receiver and directional antennae.
HEARING ASSISTANCE Transmitter: Provide hearing assistance transmitter compatible with Owner’s existing hearing assistance headphone units.
MUSIC SOURCE Music Player: Single CD-player with integral docking station for iPod and iPhone devices. Stereo minijack auxiliary input for connection of outside program sources.
CONTROL CONSOLE
A.
Cabinet: Modular, desktop; complying with EIA/ECA-310-E. ventilated front door with vision capabilities.
B.
Housing: Steel, black finish.
C.
Panel for Equipment and Controls: Rack mounted.
D.
Controls: 1.
Rear access panel kit and locking
See layout attached to end of specifications.
E.
Indicators: A visual annunciation for each distribution channel to indicate source being used.
F.
Self-Contained Power and Control Unit: A single assembly of basic control, electronics, and power supply necessary to accomplish specified functions.
G.
Size: Include 20% extra space for future equipment.
SOUND AND MUSIC SYSTEMS (122090)
269090-4 2014 by FEI
2.10
EQUIPMENT RACK
A.
Comply with EIA/ECA-310-E.
B.
House amplifiers and auxiliary equipment at each location.
C.
Housing: 1. 2. 3. 4.
Constructed of steel, front- and rear-locking doors and standard EIA/ECA-310-E-compliant, 19inch racks. Front door shall be ventilated with vision capabilities. Arranged for wall mounting, black finish. Sized to house all equipment indicated, plus spare capacity. Include 20% percent minimum spare capacity for future equipment.
D.
Power Provisions: A single switch in cabinet shall disconnect cabinet power distribution system and electrical outlets, which shall be uniformly spaced to accommodate ac-power cords for each item of equipment.
E.
Ventilation: Naturally ventilated with convection cooling.
2.11 A.
LOUDSPEAKERS Horn-Type Loudspeakers Covering Athletic Fields: 1. 2. 3. 4. 5. 6.
B.
Horn-Type Loudspeakers Covering Spectator Bleachers: 1. 2. 3. 4. 5. 6.
2.12 A.
Type: Triaxial design, with minimum full-range power rating of 400 W. Frequency Response: Within plus or minus 5 dB from 70 to 10,000 Hz. Dispersion Angle: 80 degrees horizontal by 40 degrees vertical. Mounting: Pole-mount bracket . Outdoor Location: Listed and labeled for outdoor wet environments, IP55W minimum. Finish: Powder-coat paint, light gray finish.
Type: Two-way design, with minimum full-range power rating of 200 W. Frequency Response: Within plus or minus 4 dB from 125 to 10,000 Hz. Dispersion Angle: 60 degrees horizontal by 60 degrees vertical. Mounting: Pole-mount bracket . Outdoor Location: Listed and labeled for outdoor wet environments, IP55W minimum. Finish: Powder-coat paint, light gray finish.
CONDUCTORS Jacketed, twisted pair and twisted multipair, solid copper. 1. 2.
3.
Insulation for Wire in Conduit: Thermoplastic, not less than 1/32 inch thick. Microphone Cables: Neoprene jacketed, not less than 1/32 inch thick, over shield with filled interstices. Shield No. 34 AWG, tinned, soft-copper strands formed into a braid or approved equivalent foil. Shielding coverage on conductors is not less than 60 percent. Wire in Underground Conduit: Listed for use in wet locations with integral water blocking agents.
SOUND AND MUSIC SYSTEMS (122090)
269090-5 2014 by FEI
2.13 A.
PATHWAYS Conduit and Boxes: Comply with Division 26 Section "Raceways". 1.
Outlet boxes shall be not less than 2-1/2 inches deep.
PART 3 - EXECUTION
3.1
WIRING METHODS
A.
Wiring Method: Install cables in conduit except within consoles and racks. Conceal conduit at all locations.
B.
Wiring within Enclosures: Bundle, lace, and train cables to terminal points with no excess and without exceeding manufacturer's limitations on bending radii. Provide and use lacing bars and distribution spools.
3.2
INSTALLATION OF PATHWAYS
A.
Comply with requirements in Division 26 Section "Raceways" for installation of conduits and wireways.
B.
Install manufactured conduit sweeps and long-radius elbows whenever possible.
3.3
INSTALLATION OF CONDUCTORS
A.
Comply with NECA 1.
B.
General Conductor Installation Requirements: 1. 2. 3. 4. 5.
6.
C.
Terminate conductors; no cable shall contain unterminated elements. Make terminations only at outlets and terminals. Splices, Taps, and Terminations: Arrange on numbered terminal strips in junction, pull, and outlet boxes; terminal cabinets; and equipment enclosures. Conductors may not be spliced. Secure and support cables at intervals not exceeding 30 inches and not more than 6 inches from cabinets, boxes, fittings, outlets, racks, frames, and terminals. Bundle, lace, and train conductors to terminal points without exceeding manufacturer's limitations on bending radii. Install lacing bars and distribution spools. Do not install bruised, kinked, scored, deformed, or abraded cable. Do not splice cable between termination, tap, or junction points. Remove and discard cable if damaged during installation and replace it with new cable. Cold-Weather Installation: Bring cable to room temperature before dereeling. Heat lamps shall not be used.
Separation of Wires: Separate speaker-microphone, line-level, speaker-level, and power wiring runs. Install in separate pathways or, where exposed or in same enclosure, separate conductors at least 12 inches apart for speaker microphones and adjacent parallel power wiring. Separate other communication equipment conductors as recommended by equipment manufacturer.
SOUND AND MUSIC SYSTEMS (122090)
269090-6 2014 by FEI
3.4
INSTALLATION
A.
Coordinate layout and installation of system components and suspension system with other construction that penetrates ceilings or is supported by them, including light fixtures, HVAC equipment, firesuppression system, and partition assemblies.
B.
Match input and output impedances and signal levels at signal interfaces. Provide matching networks where required.
C.
Identification of Conductors: Color-code conductors and apply wire and cable marking tape to designate wires and cables so they identify media in coordination with system wiring diagrams.
D.
Equipment Cabinets and Racks: 1. 2.
3.
Group items of same function together, either vertically or side by side, and arrange controls symmetrically. Arrange all inputs, outputs, interconnections, and test points so they are accessible at rear of rack for maintenance and testing, with each item removable from rack without disturbing other items or connections. Blank Panels: Cover empty space in equipment racks so entire front of rack is occupied by panels.
E.
Wall-Mounted Outlets: Flush mounted.
F.
Weatherproof Equipment: For units that are mounted outdoors, in damp locations, or where exposed to weather, install consistent with requirements of weatherproof rating.
3.5
GROUNDING
A.
Ground cable shields and equipment to eliminate shock hazard and to minimize ground loops, commonmode returns, noise pickup, cross talk, and other impairments.
B.
Signal Ground Terminal: Locate at main equipment cabinet. Isolate from power system and equipment grounding.
C.
Bond equipment cabinets to telecommunications ground bar with #6 copper conductor in raceway.
3.6 A.
FIELD QUALITY CONTROL Perform tests and inspections. 1.
B.
Manufacturer's Field Service: Engage a factory-authorized service representative to inspect components, assemblies, and equipment installations, including connections, and to assist in testing.
Tests and Inspections: 1. 2. 3.
Schedule tests with at least seven days' advance notice of test performance. After installing sound and music systems and after electrical circuitry has been energized, test for compliance with requirements. Operational Test: Perform tests that include originating program and page messages at microphone outlets, digital signal processor inputs, and other inputs. Verify proper routing and volume levels and that system is free of noise and distortion.
SOUND AND MUSIC SYSTEMS (122090)
269090-7 2014 by FEI
4.
Signal-to-Noise Ratio Test: Measure signal-to-noise ratio of complete system at normal gain settings as follows: a.
b. c. 5.
6.
7.
8.
Disconnect microphone at connector or jack closest to it and replace it in the circuit with a signal generator using a 1000-Hz signal. Replace all other microphones at corresponding connectors with dummy loads, each equal in impedance to microphone it replaces. Measure signal-to-noise ratio. Repeat test for each separately controlled zone of loudspeakers. Minimum acceptance ratio is 50 dB.
Distortion Test: Measure distortion at normal gain settings and rated power. Feed signals at frequencies of 50, 200, 400, 1000, 3000, 8000, and 12,000 Hz into each preamplifier channel. For each frequency, measure distortion in the paging and all-call amplifier outputs. Maximum acceptable distortion at any frequency is 3 percent total harmonics. Acoustic Coverage Test: Feed pink noise into system using octaves centered at 500 and 4000 Hz. Use sound-level meter with octave-band filters to measure level at five locations in each zone. For spaces with seated audiences, maximum permissible variation in level is plus or minus 2 dB. In addition, the levels between locations in same zone and between locations in adjacent zones must not vary more than plus or minus 3 dB. Power Output Test: Measure electrical power output of each power amplifier at normal gain settings of 50, 1000, and 12,000 Hz. Maximum variation in power output at these frequencies must not exceed plus or minus 1 dB. Signal Ground Test: Measure and report ground resistance at music and sound equipment signal ground.
C.
Inspection: Verify that units and controls are properly labeled and interconnecting wires and terminals are identified.
D.
Sound and music systems will be considered defective if they do not pass tests and inspections.
E.
Prepare test and inspection reports. 1.
3.7 A.
STARTUP SERVICE Engage a factory-authorized service representative to perform startup service. 1. 2.
3.8
Include a record of signal ground-resistance measurement certified by Installer.
Verify that electrical wiring installation complies with manufacturer's submittal and installation requirements. Complete installation and startup checks according to manufacturer's written instructions.
ADJUSTING
A.
On-Site Assistance: Engage a factory-authorized service representative to provide on-site assistance in adjusting sound levels, resetting transformer taps, and adjusting controls to meet occupancy conditions.
B.
Occupancy Adjustments: When requested within 12 months of date of Substantial Completion, provide on-site assistance in adjusting system to suit actual occupied conditions. Provide up to two visits to Project during other-than-normal occupancy hours for this purpose.
SOUND AND MUSIC SYSTEMS (122090)
269090-8 2014 by FEI
3.9 A.
DEMONSTRATION Engage a factory-authorized service representative to train Owner's maintenance personnel to adjust, operate, and maintain the sound and music systems and equipment. Refer to Division 01 sections.
END OF SECTION 269090
SOUND AND MUSIC SYSTEMS (122090)
269090-9 2014 by FEI
ELECTRONIC SOUND, INC.
Project Number 18131 06/02/2014 Page: 1 * * Proposal * *
14627 INDUSTRIAL ROAD 402-334-8550 FX 402-334-8553
OMAHA, NE 68144-3229 FARRIS ENGINEERING, INC. 11239 CHICAGO CIRCLE OMAHA, NE 68154
C06017
402-330-5900
PROJECT TITLE:
Fax: 402-330-5902
USD Track Sound
Qty Description USD Sound Announcer Mic 2 PRO CO-SAS3, SPORTS ANNOUNCE STAND 2 Shure-SM63, Omnidirectional Dynamic Handheld Wireless Mic 2 Shure-ULXP24/58-J1, Includes ULX2/58 Handheld Transmitter with SM58 Microphone 4 Shure-UA874US, Active Directional Antenna with Gain Switch 470-698 MHz 4 Shure-PA725, 10' Coaxial Cable (RG-58/U) with BNC Connectors CD/IPOD/MP3 Player 2 Tascam-CD-200IL, CD-200iL Professional Single CD Player • Built-in iPod Dock- 30-Pin & Lightning Connector# MP3 & WAV Playback & TEAC Transport 2 RadioDes-TX-J2, Unbalanced Input Transformer Four Channel Mixer 2 Shure-SCM410, Four-Channel Automatic Microphone Mixer (110V) with Logic Control and EQ per Channel, AC only, Half Rack Space Single and Dual Mount DSP 2 Biamp-NEXIA SP, NEXIA 4 line inputs and 8 line outputs. DSP for speaker processing applications with line inputs feeding a larger number of outputs 2 Biamp-LOGIC BOX, 20 programmable logic inputs/outputs for Audia/Nexia control Power Amplifiers 2 Qsc-CX902, 2 channels, 550 watts/ch at 8 Ω, 900 watts/ch at 4 Ω, 1500 watts/ch at 2 Ω 2 Qsc-CX1102, 2 channels, 700 watts/ch at 8 Ω, 1100 watts/ch at 4Ω, 1700 watts/ch at 2 Ω Loudspeakers 4 Community-R2-94Z, FULL-RANGE 3-WAY DUAL 12" GREY 80 X 40 ALLWEATHER 4 Community-PMB-2RR, POLE MOUNT BRACKET, SINGLE/DUAL LOUDSPEAKERS, PAN-TILT 4 Community-R.5-66Z, FULL-RANGE 2-WAY 12" GREY 60 X 60 ALL WEATHER 4 Community-PMB-2RR, POLE MOUNT BRACKET, SINGLE/DUAL LOUDSPEAKERS, PAN-TILT Desktop Racks
ELECTRONIC SOUND, INC.
Project Number 18131 06/02/2014 Page: 2 * * Proposal * *
14627 INDUSTRIAL ROAD OMAHA, NE 68144-3229
402-334-8550 FX 402-334-8553
Qty Description 2 MidAtlan-DTRK-1018, 10 SPACE (17-1/2") 18" DEEP DESKTOP RACK, NO DOORS, BLACK FINISH 2 MidAtlan-DT-RAP10, REAR ACCESS PANEL KIT, FITS DTRK, BLACK, 10 SPACE 2 MidAtlan-DT-PVFD-10, PLEXI-VENTED FRONT DOOR, FITS 10 SPACE DTRK RACKS, BLACK FINISH 2 MidAtlan-D2, 2 SPACE (3 1/2”) RACK DRAWER, BLACK BRUSHED FINISH Wall Rack 2 MidAtlan-DWR-10-22, 10 SPACE (17 1/2”) SECTIONAL WALL RACK, FITS 20” DEEP EQUIP., BLACK FINISH 2 MidAtlan-LVFD-10, VENTED FRONT DOOR, 64% OPEN AREA, FITS 10 SPACE DWR SERIES RACKS, BLACK FINISH Rack Accessories 2 Panelcrafters ES6814-WQ379490 Zone Rack Panel 2 12VDC Power Supply 2 Lowell-ACR-SCS4-2009-RT2, Power Panel-20A, 6-Switch 3-Unswitch Outlets, 1U, Seq/Trigger 4 Lowell-RPC-1-20A-CD, Remote Power Control-20A, 1 Duplex Outlet, 6ft Cord Wire/Cable WestPenn-AQ227, 1 PAIR 12 (19X25) BARE WATER BLOCK FPL PLTC WestPenn-452, 2 COND. 22 (7x30) TINNED SHIELDED CM WestPenn-272, 10 COND 22 (7X30) BARE CMR
Mike Pierson
Provide hearing assistance transmitter compatible with Owner's existing headphone units.
Announcer Mic
Model SM63 User Guide
MODELS SM63, SM63L, AND SM63LB DYNAMIC MICROPHONES Features • • • • • • • • • • Elegant, yet rugged, the high output SM63 series dynamic omnidirectional microphones are designed for professional applications where performance and appearance are critical. Their smooth, wide frequency response is tailored for optimum speech intelligibility, and includes a controlled low-frequency rolloff for reduced pickup of stand and wind noise. A built-in humbucking coil makes the microphones virtually immune to strong hum fields, such as those produced by studio lighting. The three models differ only in length and color. The champagne-finished SM63 is designed for hand-held use on stage and in broadcast, recording, and television studios. The champagne-finished SM63L and the black-finished SM63LB are ideal for remote interviews, sports broadcasts, and other situations where longer microphones are desirable. All three models use a patented Shure shock mount system to minimize handling noise. They also include a VERAFLEX™ grille that protects against damage from a drop of up to 2 meters (6 ft.), and is impervious to dents, rust, corrosion, and moisture. An integral pop filter effectively reduces breath noise. The SM63L and SM63LB include a twostage windscreen accessory designed for outdoor use. All models are supplied with a stand adapter and zippered storage bag. Cables are available separately.
High output, low impedance 80 to 20,000 Hz frequency response tailored for optimum speech intelligibility Low-frequency rolloff and built-in shock mount for reduced pickup of handling noise and stand vibration Humbucking coil for virtual immunity to strong electromagnetic hum fields Exceptionally rugged VERAFLEX™ grille that resists damage from drops, and is immune to rust, corrosion, and moisture Built-in pop filter that suppresses breath and wind noise Accessory windscreen supplied with SM63L and SM63LB for outdoor use under adverse wind conditions Excellent balance and feel for hand-held use Supplied snap-in stand adapter Sleek, handsome appearance looks good on stage, screen, and television
SPECIFICATIONS Type Dynamic Frequency Response 80 to 20,000 Hz
TYPICAL FREQUENCY RESPONSE FIGURE 1
Polar Pattern Omnidirectional lmpedance (at 1,000 Hz) Rated at 150 ohms (298 ohms actual) Output Level (at 1,000 Hz) -56.5 dBV/Pa (1.5 mV) (1 Pa = 94 dB SPL)
Hum Pickup (typical at 60 Hz) 21 dB equivalent SPL in a 1 millioersted field
©2005, Shure Incorporated 27C3025 (Rev. 4)
Printed in U.S.A.
ARCHITECTS' SPECIFICATIONS
Polarity Positive pressure produces positive voltage on pin 2 relative to pin 3 CARTRIDGE
X
HUMBUCKING COIL
The microphone shall be a moving coil (dynamic) type with a frequency response of 80 to 20,000 Hz. The unit shall have an omnidirectional polar characteristic. The microphone shall have a rating impedance of 150 ohms. The microphone output shall be -56.5 dB where 0 dB equals 1 milliwatt per 10 microbars. The microphone shall be provided with a swivel adapter adjustable through 90° from vertical to horizontal. The microphone swivel adapter shall permit the microphone to be placed into and removed from the adapter with a smooth snap-in movement. The adapter will be equipped with a 5/8"-27 thread for mounting on a standard microphone stand fitting. The overall dimensions of the microphone shall be 144.5 mm (5-11/16 in.) or 233 mm (9-3/16 in.) in length and 33 mm (1-1/4 in.) in diameter. The microphone shall be the Shure Model SM63, SM63L, SM63LB, or equivalent.
THREE-PIN PROFESSIONAL AUDIO CONNECTOR
YELLOW
2
3
1
BLACK
INTERNAL CONNECTIONS FIGURE 2
Shock Mount Patented internal vibration isolator Stand Adapter Snap-in, positive action, adjustable through 90° from vertical to horizontal, suitable for mounting on stand with 5/8"-27 thread Case SM63, SM63L: Champagne finish aluminum with VERAFLEX™ grille SM63LB: Black finish aluminum with VERAFLEX™ grille Dimensions 32 mm (1-1/4 in.)
FURNISHED ACCESSORIES Swivel Adapter .............................................. A57F Brown Windscreen (SM63L)..................RK229WS Black Windscreen (SM63LB)..................... 49A130 Carrying/Storage Bag ................................. 26A13
20 mm (25/32 in.)
OPTIONAL ACCESSORIES
SM63: 144.5 mm (5-11/16 in.)
Desk Stand ........................................ S37A, S39A lsolation Mount.............................................. A53M Brown Windscreen (SM63)....................RK229WS TRIPLE-FLEX™ Cable and Plug (7.6 m, 25 ft) ........................C25F
SM63L, SM63LB: 233 mm (9-3/16 in.)
OVERALL DIMENSIONS FIGURE 3
Net Weight (less cable) SM63: 99 grams (3.50 oz) SM63L, SM63LB: 124 grams (4.3 oz) Packaged Weight SM63: 567 grams (1 Ib 4 oz) SM63L, SM63LB: 595 grams (1 Ib 5 oz) Certifications Eligible to bear CE Marking. Conforms to European EMC Directive 89/336/EEC. Meets applicable tests and performance criteria in European Standard EN55103 (1996) parts 1 and 2, for residential (E1) and light industrial (E2) environments.
REPLACEMENT PARTS Cartridge ........................................................ R191 Replacement Grille (SM63) .........................RK366 Replacement Grille (SM63L) .......................RK367 Replacement Grille (SM63LB) .....................RK368 Plug Element ............................................ RK152P For additional service or parts information, please contact Shure's Service Department at 1-847-600-8699. Outside the United States, please contact your authorized Shure Service Center.
2
SAS3
SPORTS ANNOUNCER’S SWITCH
FEATURES: » Sturdy, noiseless push-to-talk switch » Can be used with both dynamic and condenser microphones
» Passive design requires no batteries or phantom » » »
power to operate 6-inch gooseneck with mic adapter for direct connection of microphone Connects with standard microphone cables Ideal for sporting event announcers
BACK OF UNIT
DESCRIPTION: The Pro Co SAS3 Sports Announcer’s Switch is a simple, rugged, desktop push-to-talk microphone switch designed specifically for sporting event announcers. This microphone signal actuating device offers clean reliable performance with any balanced or floating low-impedance (150 ohm nominal) microphone or signal source. SAS3 is designed for use with either condenser-type or dynamic microphones. The SAS3 is ideally suited for use in sports event announcing applications but is equally suitable for any application where a desktop push-to-talk device is required. The SAS3 is backed by Pro Co’s five-year, any excuse - even abuse warranty. To pass the microphone signal to the sound system, the user simply depresses and holds down the push-to-talk button on the SAS3. The SAS3 is a momentary press-to-talk switch, so the switch will need to remain depressed for as long as the user requires the signal to be “live”. Releasing the switch will prevent the signal from continuing to the sound system.
Pro Co Sound 225 Parsons Street | Kalamazoo, MI 49007 800-253-7360
Connections between the SAS3 and the the sound system are made with standard microphone cables. The user’s microphone is connected to the SAS3 through the female microphone adapter that is incorporated into the end of the 6-inch gooseneck mounted on the top panel of the device. A microphone cable is integrated in the 6-inch black chrome gooseneck. An additional Mic Input is provided via a Female XLR-type connector located on the back panel. Both gooseneck-mounted and rear panel Mic Inputs are wired in parallel and are controlled by the push-to-talk switch. A Male XLR-type connector is provided for Mic Output. The SAS3 enclosure is formed of a 16-gauge steel top and a rugged 11-gauge, black epoxy painted steel base. Steel provides excellent magnetic shielding from 60Hz AC hum fields. All control and connector function graphics are identified on a textured polycarbonate overlay. The enclosure is with (4) non-conductive, anti-skid feet on the base of the unit. Top-quality connectors and switches provide trouble-free service even in abusive situations such as remote broadcast and recording operations.
» www.procosound.com
ENGINEERING SPECIFICATIONS: The microphone signal momentary push-to-talk unit shall be suitable for the noiseless muting of any balanced or floating low impedance (150 ohm nominal) microphone or similar signal source. There shall be two (2) 3-pin female XLR-type connectors wired in parallel for input from the source. There shall be (1) 3-pin male XLR-type connector for the output. The unit shall be suitable for the use of condenser microphones and dynamic microphones. There shall be (1) momentary push button switch suitable for either hand or foot operation. The switch shall be single pole, single throw, and used to allow the microphone signal to pass from input to output. The circuit shall consist of a normally closed switch that connects pin 2 to pin 3, effectively muting the microphone signal. Activating the switch removes the “short” between pins 2 and 3 and allows the michrophone signal to pass to the output. The electronic components shall be wired to provide adequate pop suppression and sufficient bypass impedance, to allow noiseless operation with no significant signal degradation. The enclosure shall be constructed of a 16-gauge steel top and a black epoxy texture painted 11-gauge steel base. The control and connector functions shall be identified by a textured polycarbonate adhesive overlay that is fixed to the top. The top of the unit shall slope from rear
to front. The enclosure shall be provided with a threaded base suitable for the attachment of a flexible “gooseneck” microphone stand mounted to the top of the enclosure. The enclosure shall be provided with (4) four nonconductive, non-skid feet on the base of the unit. The dimensions of the unit shall be approximately 4.062” L x 6.75” W x 1.687” H at the front sloping up to 2.250” H at the rear of the unit. (103.2mm L x 171.5mm W x 42.8/57.2mm H). These dimensions do not include the microphone stand. The unit shall include one (1) 6-inch , flexible “gooseneck” microphone stand with 3-pin female XLR connector microphone input that can be fixed to the enclosure-mounted base. The gooseneckmounted microphone connector input cable shall be routed through the gooseneck and wired in parallel with the enclosure-mounted 3-pin femal XLR connector input. The microphone signal momentary push-to-talk unit shall be a Pro Co Sports Announcer’s Switch 3 (SAS3).
CONTROLS: MIC INPUT: (Gooseneck Mount)
Female 3-pin XLR-type connector accepts input from any balanced or floating low impedance (150 ohm nominal) microphone or similar signal source.
MIC INPUT:
Female 3-pin XLR-type connector accepts input from any balanced or floating low impedance (150 ohm nominal) microphone or similar signal source. Wired in Parallel with gooseneck mounted Mic Input.
DIRECT OUT:
Male 3-pin XLR-type connector provides output to sound system input.
ACTIVATION SWITCH: Momentary, SPST (single pole, single throw) switch shorts pin 2 and pin 3 of the XLR connectors together to produce the muting effect. Depressing the switch momentarily removes the short and allows the microphone signal to pass to the output. The signal can pass as long as ther switch remains depressed.
GOOSENECK INPUT (XLRF)
PRO CO MODEL: SAS3 DIMENSIONS.................. 7.00” W x 4.00” D x 2.38” H 177.8 mm W x 101.6 mm D x 60.5mm H WEIGHT.................2.50 lb 1.38 kg SHIPPING WEIGHT.................3.00 lb S (PIN 1) 1.94 kg H+ (PIN 2)
S (PIN 1) H+ (PIN 2)
C- (PIN 3)
TOP VIEW C- (PIN 3)
INPUT (XLRF)
S (PIN 1) H+ (PIN 2)
OUTPUT (XLRM) C- (PIN 3)
S1
FRONT VIEW
SIDE VIEW
Other TradeTools™ Mic Muting and Switching Products from Pro Co CDPB CDPM CDSO CDSS SAS1 SAS2 SAS3
“Panic Button” Microphone A/B Switch “Power Mute” Selectable Momentary or Latching Switch “Sign Off” Latching Mic On/Mic Off Switch “Short Stop” Momentary Microphone Muting Switch “Sports Announcer’s Switch” Push-to-Talk Mic Switch “Sports Announcer’s Switch” with Gooseneck “Sports Announcer’s Switch” with Wired Gooseneck
Plus A/V Interface Devices Direct Boxes Headphone Junction Boxes Portable Audio Player (Computer & MP3 Player) Interface Line Output Isolation Transformer Unit Line Level Splitter Microphone Combiner Microphone Splitters Reamping Box . . . plus our full line of audio cabling, snakes!
Pro Co Sound 225 Parsons Street | Kalamazoo, MI 49007 800-253-7360
» www.procosound.com SAS3-01 Rev. 09/10
ULX ® WIRELESS SYSTEMS
SOPHISTICATED, SCALABLE WIRELESS SOLUTIONS.
ULX® Wireless Systems
Take Control. Wireless applications of increased complexity and scale require powerful solutions. Experienced audio engineers and sound contractors rely on Shure ULX® wireless systems to achieve clear, hassle-free wireless sound. An ultra-wide tuning range with up to 40 compatible systems* guarantees confident command of demanding installations and live sound productions. Bulletproof wireless performance. Ultra-wide 36 MHz bandwidth and automatic frequency selection ensures consistent operation across multiple TV channels with no setup hassles.
ULXP4 Wireless Diversity Receiver Up to 1400 selectable frequencies Automatic Frequency Selection with group scan function Predictive Diversity 5-segment audio meter 5-segment RF meter Advanced multi-function LCD
* Location dependent
Superior sound quality.
Intuitive operation.
Shure’s patented Audio Reference Companding delivers crystal-clear audio transmission.
Advanced front panel controls and the large multi-function LCD allow for quick monitoring of system status.
3-segment transmitter battery fuel gauge Squelch adjustment ½ rack design Remotable ½ wave antennas Frequency and volume lockout Rugged metal chassis Furnished rack hardware Locking DC connector XLR and ¼" outputs
Handheld or Bodypack Transmitter 3-segment battery fuel gauge Backlit LCD shows group and channel Frequency and power lockout 8 hour battery life 100m (300 ft.) operating range -20dB pad switch on ULX1
ULX® Profesional Wireless Microphone Systems Systems include: ULXP4 Diversity Receiver and a choice of Handheld Microphone Transmitter.
Systems include: ULXP4 Diversity Receiver, ULX1 Bodypack Transmitter and a choice of Microphone or Guitar/Bass Cable.
HANDHELD SM58
SM86
SM87A
Beta 58A
ULXP24/58
ULXP24/SM86
ULXP24/87
®
The legendary choice of vocal performers around the globe.
Tailored frequency response for clear reproduction of vocals.
Smooth sound tailored for warm, accurate reproduction.
Beta 87A
Beta 87C
ULXP24/BETA58
ULXP24/BETA87A
ULXP24/BETA87C
MX150/O
MX150/C
®
Preferred by touring vocalists and sound professionals.
Brings exceptional clarity to live vocals.
Adds warmth to the frequency response preferred by in-ear users.
LAVALIER
WL183
WL184
WL185
ULXP14/83
ULXP14/84
ULXP14/85
Premium condenser lavalier mic for speech applications. Omnidirectional
Premium condenser lavalier mic for speech applications. Supercardioid
Premium condenser lavalier mic for speech applications. Cardioid
Subminiature Omnidirectional lavalier mic provides low visibility with professional audio quality.
Subminiature Cardioid lavalier mic provides low visibility with professional audio quality. Less susceptible to feedback. ULXP14/150/C
ULXP14/150/O
HEADWORN
WBH53
Beta quality, sensitivity and consistency in a comfortable ultra-thin design. Black or Tan. Omnidirectional Sold separately as components
WBH54
This Beta microphone features a smooth, tailored response for a warm, natural sound. Black or Tan. Supercardioid
GUITAR
INSTRUMENT
WA302
WB98H/C
Links a Bodypack Transmitter to a guitar or bass. ULXP14
A versatile solution for high volume wind, brass or percussion. ULXP14/98H
Sold separately as components
COMBO Systems include: ULXP4 Diversity Receiver, ULX1 Bodypack Transmitter and ULX2 Handheld Transmitter.
SM58
DUAL Systems include: (2) ULXP4 Diversity Receivers and (2) Transmitters.
SM58
SM87
Beta 58A
ULXP24D/58
ULXP24D/87
DUAL COMBO Systems include: (2) ULXP4 Diversity Receivers, a ULX1 Bodypack Transmitter and a choice of Handheld Transmitter(s).
SM58
ULXP124D/58
®
Handheld Transmitter
WL185
Lavalier microphone ULXP124/85
®
Beta 87A
Beta 87C
WA302
ULXP24D/BETA58
ULXP24D/BETA87A
ULXP24D/BETA87C
ULXP14D
SM87
Beta 58A
Beta 87A
Beta 87C
ULXP124D/87
ULXP124D/BETA58
ULXP124D/BETA87A
ULXP124D/BETA87C
®
Handheld Transmitter Handheld Transmitter Handheld Transmitter Handheld Transmitter Handheld Transmitter Guitar Cable (2) (2) (2) (2) (2) (2)
®
®
Handheld Transmitter Handheld Transmitter Handheld Transmitter Handheld Transmitter Handheld Transmitter (2) (2) (2) (2) (2)
OPTIONAL ACCESSORIES PA805
UHF Passive Directional Antenna
UA505
Remote Antenna Bracket and BNC Adapter
UA860
UHF Passive Omni Directional Antenna
RK323G
Black grill replacement option for Beta 58A
UA506
Rack Mount Kit for one ULX Receiver
UA870
UHF Active Directional Antenna
RK324G
Black grill replacement option for Beta 87
UA507
Rack Mount Kit for two ULX Receivers
UAPF-X1 In-Line RF Filter
UA221
Passive Antenna Splitter
UA830
UHF Active Remote Antenna Amplifier
WA610
UA440
Front Mount Antenna Cable Kit
UA844
Antenna/Power Distribution System
WA615M Handheld transmitter ID rings (5 assorted colors)
Universal Hard Carrying Case
ULX® Wireless Systems Technical Specifications ULXP4 Professional Diversity Receiver
RF Carrier Frequency Range
470-952 MHz (available frequencies depend on applicable country regulations)
Working Range 100 m (300 ft) under typical conditions (NOTE: Operating range depends on many variables, including RF signal absorption, reflection and interference)
front panel
25-15,000 Hz, ±2 dB (NOTE: Overall system frequency response depends on Audio Frequency Range microphone element)
back panel
Audio Output Level ( ref. ±38 kHz deviation, 1 kHz tone)
XLR connector (into 600Ω load): +8 dBV (line); -10 dBV (mic) 1/4-inch connector (into 3kΩload): +2 dBV
Impedance ULXS4 and ULXP4 (output): 3kΩ(1/4-inch phone jack) 20kΩ(XLR Line) 500Ω(XLR Mic)
ULXS4 Standard Diversity Receiver
front panel
back panel
Modulation
±38 kHz deviation compressor-expander system with pre- and de-emphasis
Dynamic Range
>105 dB, A-weighted
RF Sensitivity
1.26 mV for 12 dB SINAD (typical)
Image Rejection
65 dB typical
Spurious Rejection
75 dB typical
System Distortion ( ref. ±15 kHz deviation, 1 kHz modulation)
0.3% (<1%) THD typical
Power Requirements ULXS4 and ULXP4: 14-18 Vdc (negative ground), 600 mA; external ac adapter supplied. Operating Temperature Range
-20 to 50 C (-4 to 122 F) (NOTE: Battery characteristics may limit this range)
Overall Dimensions ULXS4: 41 mm H x 219 mm W x 152 mm D (1 5/8 x 8 5/8 x 6 in.) ULXP4: 44 mm H x 219 mm W x 154 mm D (1 3/4 x 8 5/8 x 6 1/16 in.)
ULX1 Bodypack Transmitter
top panel
ULX2 Handheld Transmitter
Net Weight
ULXS4: 0.6 kg (1 lbs 4 oz) ULXP4: 1.02 kg (2 lbs 4 oz)
Gain Adjustment Range
40 dB (continuously adjustable)
Impedance
input: 1 MΩ
RF Power Output
30 mW maximum (dependent on applicable country regulations)
Power Requirements
9 V alkaline battery (DURACELL® MN1604 recommended); 8.4 V optional
Battery Life
Up to 8 hours
Overall Dimensions
95.2 mm H x 63.5 mm W x 33.3 mm D (3 3/16 x 2 5/8 x 1 1/16 in.)
Net Weight (without battery)
90.7 g (3.2 oz)
Gain Adjustment Range
25 dB (continuously adjustable)
RF Power Output
30 mW maximum (dependent on applicable country regulations)
Power Requirements
9 V alkaline battery (DURACELL® MN1604 recommended); 8.4 V optional
Battery Life
Up to 8 hours
Overall Dimensions ULX2/58, ULX2/BETA 58: 241 mm L x 50.8 mm Dia. (9 1/2 x 2 in.) ULX2/87, ULX2/BETA 87: 216 mm L x 50.8 mm Dia. (8 1/2 x 2 in.) Net Weight (without battery)
©2014 Shure Incorporated
ULX2/58, ULX2/BETA 58: 298 g (10.4 oz) ULX2/86, ULX2/87, ULX2/BETA 87: 195 g (6.8 oz)
United States, Canada, Latin America, Caribbean: Shure Incorporated 5800 West Touhy Avenue Niles, IL 60714-4608 USA
Europe, Middle East, Africa: Shure Europe GmbH Jakob-Dieffenbacher-Str. 12, 75031 Eppingen, Germany
Asia, Pacific: Shure Asia Limited 22/F, 625 King’s Road North Point, Island East Hong Kong
Phone: +1 847-600-2000 Fax: +1 847-600-1212 (USA) Fax: +1 847-600-6446 Email:
[email protected] www.shure.com
Phone: +49-7262-92490 Fax: +49-7262-9249114 Email:
[email protected] www.shure.eu
Phone: +852-2893-4290 Fax: +852-2893-4055 Email:
[email protected] www.shureasia.com
AL24292
1K
03/14
SCM410 Automatic Microphone Mixer Specification Sheet SCM410 FOUR-CHANNEL AUTOMATIC MICROPHONE MIXER The Shure Model SCM410/E is a four-channel automatic microphone mixer designed for use in sound reinforcement, audio recording, and broadcast applications. The SCM410 dramatically improves audio quality in any application where multiple microphones are required. Any low-impedance dynamic or condenser microphone (including wireless) can be used with the SCM410. Multiple SCM410 mixers can be linked to other SCM410 mixers, as well as to Shure Models FP410, SCM810, SCM800, and AMS8100 mixers. Each input channel has a two-band equalizer and three logic terminals. The equalizer reduces unwanted low-frequency audio pickup and makes different microphone types—lavaliers, boundary and handheld—sound similar. The logic terminals can be used to control external devices. The SCM410 operates on 100-120 Vac power and the SCM410E operates on 220-240 Vac power. Each mixer is supplied with a power cord, rackmounting hardware, and a link cable.
SYSTEM FEATURES •
Fast, noise-free microphone selection, which automatically adjusts to changes in background noise
•
Active balanced microphone-level XLR inputs and an active balanced Mic/Line level XLR output
•
Automatic gain adjustment as additional microphones are activated-NOMA (Number of Open Microphones Attenuated)
•
Unbalanced auxiliary-level phono output
•
Bi-color channel activation and clipping LEDs
•
Last Mic Lock-On circuit maintains ambient sound
•
Peak-responding output limiter with LED indicator
•
Fits in half a rack space
•
Peak-responding output level meter
•
Adjustable EQ for each channel
SPECIFICATIONS Measurement Conditions (unless otherwise specified): Line voltage 120 Vac, 60 Hz (SCM410) or 230 Vac, 50 Hz (SCM410E); full gain; 1 kHz, one channel activated; source impedances: Mic 150 Ω; terminations: Line/Mic Aux 10 kΩ
Outputs
Frequency Response (at 1 kHz, channel controls centered) 50 Hz to 20 kHz +2 dB; –3 dB corner at 25 Hz
Output
Designed for use with
Actual (typical)
Output Clipping Level
Line
.5k Ω
300 Ω
+24 dBV
Voltage Gain (typical, controls full clockwise)
Mic
.600 Ω
3Ω
–18 dBV
Aux
.10k Ω
1.5 k Ω
+14 dBV
Output Input
Line
Mic
Aux
Low-impedance mic (150 Ω)
80 dB
40 dB
68 dB
Inputs
Impedance
Total Harmonic Distortion (through 22 Hz – 22 kHz filter; Input at 12 o' clock and Master at 12 o' clock, all other controls full counterclockwise) < 0.1% at +4 dBu output level, 50 Hz to 20 kHz Hum and Noise (150 Ω source; through 22 Hz – 22 kHz filter) Equivalent Input Hum and Noise: –123 dBV max., –125 dBV typical
Impedance Input
Designed for use with
Actual (typical)
Input Clipping Level
Mic
19–600 Ω
1.4 kΩ
–14 dBV
Output Hum and Noise (channel controls full counterclockwise) Master full counterclockwise: –90 dBV Master full clockwise: –70 dBV Common Mode Rejection >70 dB at 1 kHz Polarity All inputs to all outputs are non-inverting
TL1029 (CB) ©2003 Shure Incorporated
Modify for MANUAL operation
SCM410 AUTOMATIC MICROPHONE MIXER SPECIFICATION SHEET Input Channel Activation Attack Time: 4 ms Hold Time: 0.4 s Decay Time: 0.5 s Off-Attenuation 13 dB Overload and Shorting Protection Shorting outputs, even for prolonged periods, causes no damage. Microphone inputs are not damaged by signals up to +10 dBV (3V) Equalization Low–frequency: 6 dB/octave cut, adjustable corner from 25 to 320 Hz High–frequency: +6 dB at 5 kHz, +8 dB at 10 kHz, shelving Limiter Type: Peak Threshold: +16 dBu (at output) Attack Time: 2 ms Recovery Time: 300 ms Indicator: Lights red when limiting occurs Input LEDs Green on channel activation, red at 6 dB below clipping Phantom Power 12 Vdc open-circuit through 680 Ω resistors Operating Voltage SCM410: 100-120 Vac rated nominal, 50/60 Hz, 100 mA (maximum) SCM410E; 220-240 Vac rated niminal, 50/60 Hz, 50 mA (maximum) Mains Inrush Current (230 Vac, SCM410E only) 0.7 A peak Temperature Range Operating: –7° to 49° C (20° to 120° F ) Storage: –29° to 74° C (–20° to 165° F) Overall Dimensions 44 mm H x 219 mm W x 267 mm D (13/4 x 85/8 x 101/2 in.) Net Weight 1.75 kg (3.86 lbs) Certifications SCM410: UL listed to UL 6500 and cUL listed to E65 Canada. SCM410E: Conforms to applicable European Directives; eligible to bear CE marking. Low Voltage Directive 73/23/EEC: VDE GSCertified to EN 60065. EMC Directive 89/336/EEC: Professional Audio Products Standard EN55103 (1996); Part 1 (Emissions) and Part 2 (Immunity).
Electromagnetic Compatibility (EMC) Statement The SCM410E mixer is intended for use in E1 (residential) and E2 (light industrial) environments, as defined in European EMC standard EN 55103. It meets the applicable tests and performance criteria found in the standard for these environments. EMC conformance is based on the use of recommended and supplied cables. NOTE: Under certain circumstances, the SCM410E may be exposed to outside electromagnetic interference levels beyond what is typical in the intended environment. Should this occur, additional measures may be required to reduce interference to acceptable levels. The following table identifies possible sources of unwanted interference. Decreased Signal-toNoise Ratio
Erratic LED and/or Channel Operation
High RF Field (generated by nearby radio transmitter)
X
X
Electrostatic Discharge
X
X
Magnetic Fields (close proximity to mains, power lines, or CRTs)
X
Main Power Line Interruptions/Dips (poor power grid quality/storms) Main Surges and Line Transients (nearby lightning strikes/ mains arcs)
X
X X
X
Signal Distortion
X
X
REPLACEMENT PARTS Knob, Master (white).................................................... 95A8238 Knob, Channel Gain (blue) .......................................... 95B8238 Line (Power) Cord (SCM410) ...................................... 95A8762 Line (Power) Cord (SCM410E) .................................... 95A8778 Link Cable.................................................................... 95A8889 Fuse, SCM410 (5 x 20 mm, T 125mA L, 250V, time delay).................... 80C730 Fuse, SCM410E (5 x 20 mm, T 50mA L, 250V, time lag) ......................... 80C380 Long Rack Mount Bracket ........................................... 53A8484 Short Rack Mount Bracket ........................................... 53B8484 Straddle Bracket .......................................................... 53A8443 Bagged Hardware Kit.................................................90AA8100
OPTIONAL ACCESSORIES Line (Power) Cord, 230–240 Vac (UK) ........................ 95A8713 External 50 dB Line Pad ..................................................A15LA
SHURE Incorporated Web Address: http://www.shure.com 5800 W. Touhy Avenue, Niles, IL 60714-4608, U.S.A. Phone: 800-257-4873 Fax: 847-866-2279 In Europe, Phone: 49-7131-72140 Fax: 49-7131-721414 In Asia, Phone: 852-2893-4290 Fax: 852-2893-4055 Elsewhere, Phone: 847-866-2200 Fax: 847-866-2585
ACCESSORY Logic Box
®
®
Logic Box is a natural extension of Audia and Nexia products. This device provides both logic inputs and outputs, as a programmable control interface. Logic inputs allow creation of custom control panels, with completely programmable functions. Logic outputs allow the system to provide programmable triggers to external circuits, such as status indicators and speaker relays. Innovative design allows 20 available connections on the Logic Box to be configured in any combination of inputs and outputs. This extends true flexibility for a variety of applications, using the same hardware. The Logic Box is connected to a system on a 5-wire daisy-chain, eliminating the need for local power sources. This connection also provides the serial communication to the Audia or Nexia system. Multiple Logic Boxes, and Control Panels, can be connected on one bus, over a large physical distance.
FEATURES 20 logic connections - any combination of inputs/outputs
logic functions can be made to change along with presets
logic inputs - control system actions from external switches
various Audia/Nexia controls allowed on same system bus
actions are any individual or grouped system operation
1000' cable length per Audia/Nexia device control bus
actions include presets, mutes, ducking, combining, etc.
convenient key-hole mounting (local power not required)
logic outputs - trigger external control circuits from system
RoHS compliance
external circuits can be indicators, speaker relays, etc.
covered by Biamp Systems' five-year warranty
logic functions programmed within system software design
ARCHITECTS & ENGINEERS SPECIFICATION The logic control interface shall provide 20 logic connections, which shall be programmable in any combination of inputs/outputs. The logic control interface shall include key-hole mounting, and shall require no local power source. The logic control interface shall ® ® provide programmable remote control of internal functions and external circuitry for Biamp's Audia or Nexia products. The logic control interface shall be compliant with EU Directive 2002/95/EC, the RoHS directive. Warranty shall be 5 years. The logic control interface shall be a BIAMP Logic Box.
Biamp Systems | 9300 S.W. Gemini Drive | Beaverton, OR | 97008 | USA | +1.503.641.7287 | www.biamp.com
APPLICATIONS room combining
-
remote selection of room combinations, based on preset configurations or moveable partitions, with automatic combining of volume functions
A/V conferencing
-
source and room mode selection (i.e. conferencing or playback), plus mic indicators, speaker zone muting, and automatic camera selection
paging / music
-
zone page routing and music source selection, with page-over-music ducking, plus fault monitoring for amplifiers and external equipment
restaurant / bar
-
zone music source selection, speaker zone muting, and centralized hostess page routing
SPECIFICATIONS dimensions (H x W x D)
-
1.6" x 9.1" x 3.25" (40.64mm x 231.14mm x 82.55mm)
power consumption
-
600mW @ 12~24 Volts DC (from Audia/Nexia device)
controls per system device -
32 (Audia); 12 (Nexia); any combination of RCB controls
control cable requirements -
5-wire data grade (95~120 ohm nominal impedance) (16 pF/ft. max. capacitance) (65% min. velocity of prop.) recommended cable: Gepco 18/22AXL, Liberty AXLINK, Liberty CRESNET, or equivalent
control cable length
-
1000 feet / 300 meters (overall per Audia/Nexia device)
control bus wiring
-
single daisy-chain (system device in center or at one end)
control programming
-
each logic connection configured for specific operation by means of drag & drop icons within the system design software
logic input trigger
-
contact-closure or 5V TTL
logic output type
-
open collector (40V / 500mA maximum per output)
logic cable length
-
up to 2000 feet / 600 meters (per logic connection)
compliance
-
EU Directive 2002/95/EC, the RoHS directive
Biamp Systems | 9300 S.W. Gemini Drive | Beaverton, OR | 97008 | USA | +1.503.641.7287 | www.biamp.com
CX 2-channel Professional Power Amplifiers
CX302 | CX502 | CX702 | CX902 | CX1102 | CX302V | CX602V | CX1202V
All models include an integrated security cover for tamper-proof installations
The CX Series is designed to meet the
Features
specialized needs of sound contractors. Eight
• 8 models to meet your exact power requirements
2-channel models have been designed from
• E xclusive PowerLight switch-mode power supply technology for high performance and compact size
the ground up, combining the exclusive QSC PowerLight™ technology with specific features to meet the requirements of fixed installations.
• Custom integrated security cover for tamper proof installations • Variable speed fan for low noise • 1 dB detented gain controls for fast and accurate gain settings
With high-output power, versatile loading
• A ctive inrush limiting eliminates AC inrush current, removing the need for expensive power sequencers
options, high thermal capacity and unmatched
• XLR and detachable Euro-style input connectors
reliability, the CX Series is the perfect solution
• H D15 DataPort connector for QSControl computer control or signal processing accessories
to any permanently installed sound system.
• S electable high-pass filters protect speakers and prevent speaker transformer saturation with minimal effect on program material (33 Hz or 75 Hz on non-V models, 50 Hz or 75 Hz on V models)
CX 2-channel Amplifiers Watts per channel 8Ω** 4Ω**
• Dip switch control for clip limiters, high-pass filters, bridge-mono and parallel operation
Model
70 V*
CX302
−
200
325
600
• C omprehensive front panel indicators including signal, clip, protect and QSC’s exclusive bridge-mono and parallel input LEDs
CX502
−
300
500
800
• Barrier strip output connector
CX702
−
425
700
1200
CX902
440
550
900
1500
• C omprehensive protection circuitry including DC, infrasonic, thermal overload and short circuit protection
CX1102
1000
700
1100
1700
CX302V
250
−
−
−
CX602V
440 550
−
−
CX1202V
1000
1100
−
700
*1 kHz, 0.05% THD **20 Hz – 20 kHz, 0.05% THD †1
kHz, 1% THD
2Ω†
• C lass H complementary bipolar output circuitry for high efficiency (CX702, CX902, CX1102 & CX1202V) • O ptional external transformer accessory pack for isolated 70 and 100 volt outputs (converts CX302 to 400 watts per channel isolated output) • C ompact size – all models only 2 RU and 14" deep for reduced rack cost and floor space • Lightweight – all models only 21 pounds (9.5 kg) for easier racking and shipping • 3-year warranty plus optional 3-year extended service contract
CX 2-Channel
Specifications
CX302
CX502
CX702
CX902
CX1102
CX302V
CX602V
CX1202V
Stereo Mode (both channels driven)
Continuous average output power per channel
8Ω / 20 Hz – 20 kHz / 0.05% THD
200 W
300 W
425 W
550 W
700 W
– 550 W
700 W
4Ω / 20 Hz – 20 kHz / 0.05% THD
325 W
500 W
700 W
900 W
1100 W
–
–
1100 W
2Ω / 1 kHZ / 1% THD
600 W
800 W
1200 W
1500 W
1700 W
–
–
-
70V / 20 Hz – 20 kHz / 0.05% THD
−
—
—
400 W
800 W
200 W
400 W
800 W
70V / 1 kHz / 0.05% THD
—
—
—
440 W
1000 W
250 W
440 W
1000 W
70V / 1 kHz / 1% THD
—
—
—
600 W
1200 W
300 W
600 W
1200 W
Bridge-Mono Mode
Bridge-mono mode operation
16Ω / 20 Hz – 20 kHz / 0.1% THD
400 W
600 W
850 W
1100 W
1400 W
—
1100 W
1400 W
8Ω / 20 Hz – 20 kHz / 0.1% THD
700 W
1100 W
1500 W
2000 W
2200 W
–
–
2200 W
4Ω / 1 kHz / 1% THD
1200 W
1600 W
2400 W
3000 W
3400 W
–
–
–
140V / 20 Hz – 20 kHz / 0.1% THD
—
—
—
800 W
1600 W
400 W
800 W
1600 W
140V / 1 kHz / 0.05% THD
—
—
—
880 W
2000 W
500 W
880 W
2000 W
140V / 1 kHz / 1% THD
2400 W
—
—
—
1200 W
2400 W
600 W
1200 W
Signal to Noise (20 Hz – 20 kHz)
> -107 dB
> -107 dB
> -106 dB
> -106 dB
> -106 dB
> -106 dB
> -106 dB
> -106 dB
Input Sensitivity at 8Ω
1.26 Vrms
1.23 Vrms
1.16 Vrms
1.17 Vrms
1.35 Vrms
1.26 Vrms
1.26 Vrms
1.26 Vrms
Gain at 8Ω
30 dB
32 dB
34 dB
35 dB
35 dB
35 dB
35 dB
35 dB
Output Circuitry
Class AB+B
Class AB+B
2-tier Class H
2-tier Class H
2-tier Class H
Class AB+B
Class AB+B
2-tier Class H
Distortion (SMPTE-IM)
< 0.02%
Distortion (typical)
20 Hz – 20 kHz: 10 dB below rated power
< 0.01% THD
1.0 kHz and below: full rated power
< 0.01% THD
Frequency Response
20 Hz - 20 kHz, ± 0.2 dB
Damping Factor
> 500
Input Impedance
6k ohms unbalanced, 12k ohms balanced
Input Clipping
10 Vrms (+22 dBu)
Cooling
Variable-speed fan, rear-to-front air flow
Connectors
Input: 3-pin XLR & 3-pin detachable terminal blocks (1 each per channel) Output: Safety shrouded barrier strip
Amplifier Protection
Full short circuit, open circuit, thermal, ultrasonic, RF protection. Stable into reactive or mismatched loads
Load Protection
On/off muting, DC-fault power supply shutdown
Dimensions (HWD)
3.5" (8.9 cm) 2 RU x 19" (48.3 cm) rack mounting x 14" (35.6 cm) from front mounting rails
Weight - Net / Shipping
21 lb (9.5 kg) / 27 lb (12.3 kg)
120V Current Consumption
Idle
0.8 A
0.9 A
0.9 A
0.9 A
0.9 A
0.8 A
0.9 A
0.9 A
8Ω
3.8 A
5.6 A
5.0 A
6.0 A
7.6 A
–
–
–
of program material at (typical maximum unclipped power)
4Ω
6.0 A
9.0 A
7.9 A
9.5 A
11.6 A
–
–
–
2Ω
9.6 A
14.0 A
11.8 A
14.0 A
16.6 A
–
–
–
70V
–
–
–
–
–
5.7 A
8.7 A
12.0 A
1/8 power pink noise
1/3 power pink noise
8Ω
5.4 A
8.0 A
8.4 A
11.0 A
13.1 A
–
–
–
with severe clipping)
(typical of program material
4Ω
8.9 A
13.3 A
13.5 A
17.0 A
20.0 A
–
–
–
2Ω
14.3 A
21.0 A
22.0 A
27.0 A
–
–
–
–
70V
–
–
–
–
–
8.0 A
13.0 A
19.0 A
Specifications subject to change without notice.
please recycle
QSC, the QSC logo and PowerLight are registered trademarks of QSC Audio Products, LLC in the U.S. Patent and Trademark office and other countries. All other trademarks are the property of their respective owners. Patents may apply or be pending.
1675 MacArthur Boulevard • Costa Mesa, CA 92626 • Ph: 800/854-4079 or 714/957-7100 • Fax: 714/754-6174 CX 2-channel Spec Sheet - 05/15/09
qscaudio.com
R2-94Z Application Solutions
SPECIFICATIONS
DEFINED COVERAGE, WEATHER-RESISTANT, THREE-WAY LOUDSPEAKER SYSTEM WITH 80° X 40° COVERAGE
Field Speaker
Loudspeaker Type: 3-way horn loaded triaxial, weather-resistant Operating Range: Max Input Ratings:
70 Hz to 16 kHz 70 Hz to 10 kHz (±5 dB) 400W continuous, 1000W program 40 volts RMS, 89 volts momentary peak
Recommended Power 830W to 1200W @ 4 ohms Amplifier: Sensitivity (1W/1m):
105 dB SPL (80 Hz to 16 kHz 1/3 octave bands) 106 dB SPL (250 Hz to 4 kHz speech range)
Maximum Output: 131 dB SPL / 138 dB SPL (peak) Nominal Impedance: 4 ohms Minimum Impedance: 2.9 ohms @ 260 Hz 80° H (+0° / -20°, 1.25 kHz to 10 kHz) Nominal –6dB 40° V (+13° / -5°, 1.25 kHz to 10 kHz) Beamwidth: 100° H x 100° V (400 Hz) Axial Q / DI: 22.8 / 13.6, 1.25 kHz to 10 kHz Crossover Frequency: 600 Hz / 3.5 kHz Recommended Signal 70 Hz high pass filter Processing: LF 2 x 12” weather-treated, Ferrofluid-cooled MF 1 x M200 2” exit, non-metallic diaphragm, Drivers: Ferrofluid-cooled HF 1 x 1” exit, titanium diaphragm Driver Protection: DYNA-TECH protection circuitry
APPLICATIONS • • • • • • • • •
FEATURES • • •
Input Connection: 12 foot (4 m) SJOW #16 gauge Controls: None Enclosure: Hand-laminated fiberglass, light grey gelcoat Mounting/Rigging (5) 1/2-13 rigging points Provisions: 3-layer WeatherStop™, light grey Grille: (Zinc-rich epoxy dual-layer powder coated perforated steel grille, foam, woven poly mesh) Environmental IEC529 IP55W rating with a minimum 5-degree Performance: downward aiming angle Required Accessories: 70 Hz high pass filter Supplied Accessories: Weather-resistant mounting yoke, light grey Optional Accessories: TRC400 400-watt 70/100/140-volt transformer Dimensions—Height: 24.75 inches (629 mm) Width: 24.75 inches (629 mm) Depth: 30.75 inches (781 mm) Weight: 96 lbs (43.5 kg) Shipping Weight: 124 lbs (56.2 kg)
NOTES: 1. Sensitivity: Free field pink noise measurement at 40 ft (12.2 m) at 10% power; extrapolated to 1 meter and an input of 2 volts RMS. 2. Watts: All wattage figures are calculated using the rated nominal impedance.
Athletic fields (football, soccer, baseball, tennis) Small arenas, athletic field houses Theme and amusement parks Fairgrounds, rodeos, air shows Racing tracks, skating rinks, swimming pools Convention centers, factories, warehouses Cruise ships Portable sound systems Electronic carillons
• • • • •
Weather resistant construction Weather-treated drivers and crossovers Corrosion-resistant zinc-rich epoxy dual-layer powder coated steel grille and yoke Application-specific coverage pattern High-efficiency horn loading High-fidelity, full-range reproduction of music and speech Included weather-resistant mounting yoke for easy mounting and aiming Five-year product warranty / Fifteen-year enclosure warranty
DESCRIPTION The R2-94Z full-range loudspeaker system is engineered to provide quality, long throw full-range sound projection in a variety of outdoor and indoor applications. Its wide, smooth frequency response and high efficiency ensures high-fidelity music reproduction along with superb projection of clear, intelligible speech at very low distortion. The R2-94Z is an all horn loaded triaxial design using precision waveguides manufactured by Community of hand-laminated fiberglass. The outer enclosure forms a double wall construction with the internal bass horn, providing a completely weather-sealed chamber for the LF drivers. The mid/high frequency horn assembly is mounted in the mouth of the bass horn. A high quality passive crossover with dynamic driver protection is included. The result is a loudspeaker system that is extremely strong, non-resonant, weather-resistant, and easy to install.
Community Professional Loudspeakers, 333 East Fifth Street, Chester, PA 19013-4511 USA 610-876-3400 · Fax 610-874-0190 ·
[email protected] · www.communitypro.com
R2-94Z DEFINED COVERAGE, WEATHER-RESISTANT, THREE-WAY LOUDSPEAKER SYSTEM WITH 80° X 40° COVERAGE
True to Specification
IMPEDANCE Min Z 30 Hz - 20000 Hz = 2.9 Ohms @ 270 Hz
Resolution <500 Hz = 10 Hz, >500 Hz = 22 Hz, 1/8 octave smoothing 120
20
110
16 Ohms
dB SPL
FREQUENCY RESPONSE
100 90
12 8
80
4
70
0 10
100
1,000
10
10,000
100
1,000
BEAMWIDTH
AXIAL Q Horizontal
Vertical
100
Q
Degrees
1000
100
10 100
10,000
Frequency in Hertz
Frequency in Hertz
10
1 1,000
10,000
100
1,000
Frequency in Hertz
10,000 Frequency in Hertz
DIMENSIONS 30.75" [781.05] 17.25" [438.15]
3.622" [92] .236" [6] (TYP)
YOKE
24.75" [628.7]
M200
7.992" CL [203]
HFE2 16.693±.079" [424±2]
12" LF DRIVER
7.992" [203]
1.220" [31]
∅.532" [∅13.5] (TYP 7 PLACES)
.472" [12]
1.220" [31] (TYP)
24.75" [628.7]
(5) 1/2-13 THREAD
SIDE VIEW
FRONT VIEW
TOP VIEW
21.000" [533.4]
1.260" [32]
R2 YOKE
ARCHITECTURAL SPECIFICATIONS The loudspeaker system shall be a horn-loaded, three-way, full-range tri-axial design with two 12" Ferrofluid-cooled woofers treated with moisture repellant on a bass horn and one 2" exit Ferrofluid-cooled midrange compression drivers with a nonmetallic diaphragm and one 1" exit HF driver with a titanium diaphragm mounted on respective fiberglass horns built within the bass horn. Drivers shall be connected to an integral crossover with crossover frequencies of 600 Hz and 3.5 kHz and integral over-current protection circuitry using high positive current coefficient resistors. The input connection shall be one 16-2 12-foot (4m) SJOW Cable with stripped ends. The loudspeaker enclosure shall be an integral double-wall weather-sealed light grey fiberglass bell with a three-layer weather-resistant grille. The steel grille shall be powder coated with a proprietary zinc-rich epoxy dual-layer powder coating process in light grey to color match the enclosure. The system shall have an IEC529 IP rating of IP55W with a minimum 5-degree downward aiming angle. There shall be five 1/2 - 13 threaded mounting points. The system shall have an amplitude response of 70 Hz to 10 kHz (+/- 5 dB), input capability of 40V RMS, 105 dB sensitivity at one meter / 2 V and 4 ohms nominal impedance. The nominal dispersion shall be 90°H x 40°V from 1250 Hz to 10 kHz. The loudspeaker shall be 24.75 in. (629 mm) H x 24.75 in. (629 mm) W x 30.75 in. (781 mm) D and weigh 96 lbs. (43.5 kg).
Community strives to improve its products on a continual basis. Specifications are therefore subject to change without notice.
communitypro.com R2-94Z [1DEC2009]
Innovative design. Legendary sound.
R.5-66Z Application Solutions
SPECIFICATIONS
2-WAY HORN LOADED WEATHER-RESISTANT FULL-RANGE LOUDSPEAKER
Bleacher Speaker
Loudspeaker Type: 2-way, horn loaded coaxial, weather-resistant Operating Range: Max Input Ratings:
85 Hz to 16 kHz 125 Hz to 10 kHz (±4 dB) 200W continuous, 500W program 40 volts RMS, 89 volts momentary peak
Recommended Power 420W to 600W @ 8 ohms Amplifier: Sensitivity (1W/1m):
103 dB SPL (125 Hz to 10 kHz 1/3 octave bands) 103 dB SPL (250 Hz to 4 kHz speech range)
Maximum Output: 126 dB SPL / 133 dB SPL (peak) Nominal Impedance: 8 ohms Minimum Impedance: 4.1 ohms @ 9.6 kHz Nominal –6dB 60° H (+3° / -8°, 1.6 kHz to 12.5 kHz) Beamwidth: 60° V (+20° / -16°, 1.6 kHz to 12.5 kHz) Axial Q / DI: 21.4 / 13.3, 1.6 kHz to 12.5 kHz Crossover Frequency: 2 kHz Recommended Signal 90 Hz high pass filter Processing: Drivers:
LF (1) 12” Ferrofluid-cooled HF (1) 1” exit, titanium free, Ferrofluid-cooled
Driver Protection: DYNA-TECH Input Connection: 12 foot (4 m) SJOW #16 gauge
APPLICATIONS • • • • • • • •
Fill speaker for stadia, athletic fields, arenas and race tracks Convention centers Outdoor background music / paging systems Theme and amusement parks Fairgrounds, rodeos, air shows Malls, cruise ships, skating rinks Swimming pools Portable sound systems
Controls: None Enclosure: Rotomolded LLDPE, light grey
FEATURES •
Mounting/Rigging (5) 3/8-16 rigging points Provisions: 3-layer WeatherStop™, light grey Grille: (Zinc-rich epoxy dual-layer powder coated perforated steel grille, foam, woven poly mesh) Environmental IEC529 IP55W rating with a minimum 5-degree Performance: downward aiming angle Required Accessories: 24 dB/Oct high pass filter Supplied Accessories:
(1) Yoke bracket, light grey (1) Aiming strap
Optional Accessories: PMB Series pole mount brackets Dimensions—Height: 16 inches (406.4 mm) Width: 16 inches (406.4 mm) Depth: 15.94 inches (404.88 mm) Weight: 35 lbs (15.9 kg) Shipping Weight: 40 lbs ( 18.14 kg)
• • • • • • •
Weather-resistant, rotomolded UV enclosure Weather-treated drivers and crossovers Corrosion-resistant zinc-rich epoxy dual-layer powder coated steel grille and yoke Pattern control down to 630 Hz High efficiency Integral mounting points High power passive crossover DYNA-TECH protection circuitry
DESCRIPTION The R.5-66Z two-way, full-range loudspeaker system is engineered to provide quality full-range sound projection in a variety of outdoor and indoor applications. Its wide range, smooth frequency response and high efficiency ensure both high fidelity music reproduction and superb projection of clear intelligible speech with very low distortion. Five-year limited product warranty; fifteen-year enclosure warranty.
NOTES: 1. Sensitivity: Free field pink noise measurement at 35 ft (10.7 m) at 75% power; extrapolated to 1 meter and an input of 2.83 volts RMS. 2. Watts: All wattage figures are calculated using the rated nominal impedance.
Community Professional Loudspeakers, 333 East Fifth Street, Chester, PA 19013-4511 USA 610-876-3400 · Fax 610-874-0190 ·
[email protected] · www.communitypro.com
R.5-66Z 2-WAY HORN LOADED WEATHER-RESISTANT FULL-RANGE LOUDSPEAKER
True to Specification
FREQUENCY RESPONSE
IMPEDANCE
Resolution <500 Hz = 10 Hz, >500 Hz = 40 Hz, 1/8 octave smoothing
Min Z 20 Hz - 20000 Hz = 4.1 Ohms @ 9580 Hz
120
Ohms
dB SPL
110 100 90 80 70 10
100
1,000
32 28 24 20 16 12 8 4 0
10,000
10
100
Frequency in Hertz
BEAMWIDTH
10,000
AXIAL Q Horizontal
Vertical
1000
100
100
10
Q
Degrees
1,000 Frequency in Hertz
10
1
100
1,000
10,000
100
1,000
Frequency in Hertz
10,000 Frequency in Hertz
DIMENSIONS R.5 YOKE 15.94" (404.88mm)
16.000" [406.4]
16" (406.4mm)
.197" [5] 10.197" [259] (TYP)
16" (406.4mm)
10.0” [254]
16.394" [416.4]
SIDE VIEW
FRONT VIEW
REAR VIEW
8.197" [208.2]
2.000" [50.8] 1.000" [25.4]
4.625" [117.48]
2.750" [69.85]
ARCHITECTURAL SPECIFICATIONS The loudspeaker system shall be a horn-loaded, two-way, coaxial design consisting of one 12" Ferrofluid-cooled driver and one 1" exit, titanium free, Ferrofluid-cooled compression driver mounted on a horn inside the cabinet. The drivers shall be connected to a passive crossover network with a crossover frequency at 2 kHz with driver protection using DYNA-TECH protection circuitry. The cabinet shall be a rotomolded linear low density polyethylene enclosure providing weather and UV resistance with a three-layer weather resistant grille. The steel grille shall be powder coated with a proprietary zinc-rich epoxy dual-layer powder coating process in light grey to color match the enclosure. The system shall have an IEC529 IP rating of IP55W with a minimum 5-degree downward aiming angle. The input connection shall be one 12' (4m) SJOW #16 gauge cable with stripped ends. The enclosure shall incorporate five 3/8-16 rigging points for multiple mounting options. In addition, the loudspeaker will be supplied with one zinc-rich epoxy dual-layer powder coated steel yoke bracket. The loudspeaker system shall have an amplitude response of 85 Hz to 16 kHz (+/- 4 dB SPL), an input capacity of 40V RMS, 103 dB SPL sensitivity @ 2.83V / 1 meter between 250 Hz to 4 kHz at a nominal 8 ohm impedance. The nominal dispersion shall be 60º x 60º over a frequency range of 1.6 kHz to 12.5 kHz. The dimensions of the enclosure are defined as 16" x 16" x 16" (HWD) at a weight of 35 lbs. Community strives to improve its products on a continual basis. Specifications are therefore subject to change without notice.
communitypro.com R.5-66Z [30NOV2009]
Innovative design. Legendary sound.
PMB Series Pole Mount Bracket Kits
PMB-1RR Pole Mount Bracket
PMB-2RR Pole Mount Bracket
PMB-2RR Pole Mount Bracket
Community offers the PMB Series Pole Mount Bracket Kits for mounting small R-Series and small WET Series loudspeakers to poles and columns. These brackets were designed for use with R.25 and R.5 loudspeakers, but can also be used with Community’s RMG-200A, W2-218, W2-228, W2-2V8* and W2-2W8 loudspeaker models. The PMB-1RR bracket is intended for use with a single loudspeaker with vertical downtilt capability, while the PMB-2RR bracket can be used to mount up to two loudspeakers in a “top-bottom” configuration with left-to-right panning and vertical downtilt. The bolt-together mounting kit assembly attaches to a pole or column 6 inches (152 mm) or greater in diameter by using clamps and ¾-inch stainless steel banding. Clamps and assembly hardware are included in the mounting kits, with banding sold separately. A U-shaped mounting yoke is already included with the small R-Series and WET Series loudspeakers. For each PMB-1RR and PMB-2RR Pole Mount Bracket attached to a pole or column, two stainless steel bands must be used. Community offers part number PMB-BAND for use with the PMB Series mounting kits, which includes 92 inches (2337 mm) of banding, or enough to provide two bands for a 10.75-inch or smaller diameter pole. Therefore, for poles between 6 inches and 10.75 inches in diameter, use one PMB-BAND per bracket. For poles between 10.75 inches (273 mm) and 25.25 inches (641 mm) in diameter, use two PMB-BAND per bracket**. For installations with multiple pole mount requirements or with poles greater than 25.25 inches (641 mm) in diameter, Community also offers part number BAND100FT which includes 100 feet (30.5 m) of stainless steel banding. In pole mount installations, mounted objects should be secured to the mounting structure with safety cables. When using either the PMB-1RR or PMB-2RR bracket, an additional PMB-1RR bracket can also be mounted above the loudspeaker and bracket assembly, to be utilized as a safety cable attachment point. The PMB-1RR and PMB-2RR brackets include safety cable clips for R.25 and R.5 loudspeakers when used for this purpose. Cable clips for RMG-200A and small WET loudspeakers must be devised by the installer. Safety hardware, cabling, shackles and fittings must also be supplied by the installer to meet the needs of the installation. All parts in the PMB mounting kits are constructed of weather-resistant stainless steel, aluminum or steel with a hot-dipped galvanized finish. The PMB-1RR and PMB-2RR Pole Mount Bracket Kits are suitable for outdoor use and non-corrosive atmosphere indoor applications.
SPECIFICATIONS: Material (Pole Bracket and Clamp Bolt):
Hot-dipped galvanized steel
Material (Fasteners):
Stainless steel
Material (Clamp):
Aluminum
PMB-1RR Working Load: 50 lbs (22.7 kg) PMB-2RR Working Load: 100 lbs (45.4 kg) Design Factor:
Part No.
Description
PMB-1RR
Pole mount bracket, single loudspeaker, vertical downtilt to 90 degrees
PMB-2RR
Pole mount bracket, single or dual loudspeakers, vertical downtilt and left-toright panning (see reverse side for downtilt and panning angles)
PMB-BAND
Stainless steel banding, 92 inches (2337 mm)
BAND100FT
Stainless steel banding, 100 feet (30.5 m)
10:1 ratio (static vertical load)
*Model W2-2V8 is designed for outdoor underbalcony use and is not intended for direct weather exposure. **When measuring the diameter of the pole, be sure to measure at the position where the pole mount bracket will be attached. Many poles taper with height.
Community Professional Loudspeakers, 333 East Fifth Street, Chester, PA 19013-4511 USA 610-876-3400 · Fax 610-874-0190 ·
[email protected] · www.communitypro.com
PMB Series Pole Mount Bracket Kits PMB-1RR
LOUDSPEAKER DOWNTILT AND PAN CLEARANCE
SIDE VIEW Vertical downtilt capability of all loudspeakers is 90°
90°
R.5, R.25, RMG-200A, W2-218, W2-228, W2-2V8, W2-2W8 85° 42°
PMB-2RR 85°
85°
90° 42°
42°
45°
TOP VIEW Left-to-right panning capability of single loudspeaker
R.5
R.25
RMG-200A
W2-218,W2-228, W2-2V8,W2-2W8
SIDE VIEW Downward tilt capability of single loudspeaker 100°
90°
R.5
SIDE VIEW
100°
RMG-200A
R.25
W2-218,W2-228, W2-2V8,W2-2W8 WET in Top Position W2-218=20º W2-228=35º W2-2W8=35º W2-2V8=N/A
30°
18°
100°
45°
Downward tilt capability of dual loudspeakers
100°
100°
100°
90°
R.5
R.25
RMG-200A
W2-218,W2-228, W2-2V8,W2-2W8
IMPORTANT NOTE: When two loudspeakers are mounted on a PMB-2RR in top-bottom configuration and are panned to the left and/or right at different pan angles, the vertical downtilt of the top loudspeaker may be limited by interference from the position of the U-shaped mounting yoke of the lower loudspeaker. Installation of loudspeakers should be performed only by trained and qualified personnel. It is strongly recommended that a licensed professional structural engineer approve the mounting design.
communitypro.com PMB [22AUG2012]
96-01154 / rev 1c / 11-14-12
DTRK Series 19” Desktop Racks EIA/TIA Compliant
EXCEPTIONAL SUPPORT & PROTECTION™
Attractive desktop and under-desk equipment mounting solution
Features • Ships fully assembled • Steel construction • Vented and Plexi front doors available • Brush Grommet rear access panel available • Optional brackets provide compatibility with the
patent-pending LeverLock™ tool free and hardware free internal device and cable management system accessories • Optional casters for under-desk use • UL Listed in the US and Canada
Architects and Engineers’ Specifications FEATURED OPTIONS · LeverLock™ tool free and hardware free internal device and cable management system accessories shall be model # LL-XXYY (XX = type, YY = size, refer to middleatlantic.com for additional details) · Front doors shall be model # DT-VFD-XX (vented), DT-PVFD-XX (plexi/vented) · Solid rear access panel with brush cable entry shall be model # DT-RAPXX · Commercial grade caster kit shall add 2-3/4” to overall height, include four casters with a 300 lb. weight capacity, and shall be model # DTRK-W · Runner kit shall be 5-RS18
c u s t o m i z a b l e s p e c i f i c at i o n c l i p s ava i l a b l e at m i d d l e at l a n t i c . c o m US: New Jersey • California • Illinois • Voice: 973-839-1011 Fax: 973-839-1976 • middleatlantic.com Canada: Ontario • British Columbia • Voice: 613-836-2501 Fax: 613-836-2690 • middleatlantic.ca
96-01154 / rev 1c / 11-14-12 / DTRK Series
EIA compliant 19” desktop/under-desk equipment rack shall be Middle Atlantic Products model #DTRK-__18 (see chart for available models). Overall dimensions of DTRK shall be __”H x 21-3/8”W x 19-1/2”D (refer to chart). Useable height of DTRK shall be __ rackspaces, useable depth shall be 18-1/2”. DTRK shall come equipped with two pairs of steel rackrail with tapped 10-32 mounting holes in universal EIA spacing, black e-coat finish and numbered rackspaces. Sides of DTRK shall feature vertical slotted vent pattern for ventilation. DTRK shall accept patentpending LeverLock™ tool free and hardware free internal cable and device management system accessories when used with optional LL-DTRK adapter (10 space + only). DTRK shall be of fully welded construction. DTRK shall be finished in an environmentally friendly, durable metallic grey powdercoat. Fully welded construction shall provide a static capacity of 1,200 lbs. and a UL Listed load capacity of 300 lbs. DTRK shall be UL Listed in the US and Canada. DTRK shall be GREENGUARD Indoor Air Quality Certified for Children and Schools. DTRK enclosure shall comply with the requirements of RoHS EU Directive 2002 / 95 / EC compliant. DTRK shall be manufactured by an ISO 9001 and ISO 14001 registered company. DTRK enclosure shall be warrantied to be free from defects in material or workmanship under normal use and conditions for the lifetime of the rack.
DTRK basic dimensions All dimensions in inches unless otherwise noted [All dimensions in brackets are in millimeters]
OPTIONAL VENTED FRONT DOOR
OPTIONAL REAR ACCESS PAN
OPTIONAL PLEXI VENTED FRONT DOOR
TOP VIEW
2.56 [65] 16.56 [421]
.66 [17] (OPTIONAL REAR ACCESS PAN)
1.54 [39] (OPTIONAL FRONT DOOR)
19.50 [495 ]
21.38
[ 543 ]
"E" HEIGHT W/OPTIONAL RUNNER KIT
"D" HEIGHT W/FEET
REAR VIEW
"C" HEIGHT W/OPTIONAL CASTERS
"A" HEIGHT RACK ONLY
"B" USEABLE HEIGHT
FRONT VIEW
LEFT SIDE VIEW
BOTTOM VIEW
PART #
“A” HEIGHT RACK ONLY
“B” USEABLE HEIGHT
“C” HEIGHT w/CASTER ADDS 2.75 [70]
“D” “E” HEIGHT HEIGHT w/ FEET w/ RUNNER KIT ADDS .5 [13] ADDS .25 [6]
DTRK-718
14.13 [359]
12.25 [311] (7 rackspaces)
16.88 [429]
14.63 [371]
14.38 [365]
DTRK-1018
19.38 [492]
17.5 [445] (10 rackspaces)
22.13 [562]
19.88 [505]
19.63 [498]
DTRK-1218
22.88 [581]
21.0 [533] (12 rackspaces)
25.63 [651]
23.38 [594]
23.13 [587]
DTRK-1418
26.38 [670]
24.50 [622] (14 rackspaces)
29.13 [740]
26.88 [683]
26.63 [676]
DTRK-1818
33.38 [848]
31.50 [800] (18 rackspaces)
36.13 [918]
33.88 [860]
33.63 [854]
OPTIONAL LEVERLOCK INSIDE VIEW
US: New Jersey • California • Illinois • Voice: 973-839-1011 Fax: 973-839-1976 • middleatlantic.com Canada: Ontario • British Columbia • Voice: 613-836-2501 Fax: 613-836-2690 • middleatlantic.ca
DWR Series features:
wall mount rack
pivoting, sectional wall cabinet is ideal for larger systems in both secured and non-secured areas
• Available in 17”, 22”, 26” and 32” overall depths with 15”, 20”, 24” and 30” of useable depth • Tool-Free Quick-Mount™ system for easy, one-person mounting of the center section to the backpan on the jobsite • New center section rear channel accommodates slim power to save space • Optional minimum-clearance latch allows side-by-side or interior corner mounting • 16-gauge steel construction with 1/8” thick laser-cut corner braces • Reversible padlockable center section is keyed differently from optional front door for security • 2” knockouts, 4” knockouts for Wiremold 4000® Series raceways, and knockouts for UCP Series universal connector panels on side • Grounding/bonding stud in top and bottom of center section and backpan facilitates proper grounding and bonding of electronic equipment, as per NEBS and NEC standards • Finished in a durable black textured powder coat
specifications:
• UL listed in the US and Canada
EIA compliant 19” wall mount rack shall be Middle Atlantic Products model # DWR-__-__ (refer to chart). Overall dimensions shall be 23.4” W x __” H x __” D (refer to chart). Weight capacity shall be __ lbs. ToolFree Quick-Mount™ system enables one-person installation. Useable depth shall be __” (refer to chart) and shall extend into the back pan 3.5”. Center section and back pan shall be 16-gauge steel, phosphate pre-treated and finished in a black textured powder coat. Rackrail shall be constructed of 11-gauge steel with tapped 10-32 mounting holes in universal EIA spacing with black e-coat finish and marked rack spaces. Rack shall be constructed to swing open for component cabling access, center section shall pivot for either left or right opening. Rack shall have a rear knockout panel with 1/2”, 3/4”, 1”, 1-1/2”, 2” and 3” electrical knockouts installed in base, and a rear knockout panel with 1/2”, 3/4”, 1”, 1-1/2”, 2” and 3” electrical knockouts, four Decora® cutouts, and BNC knockouts for UHF/VHF antennas installed in top. Large laser knockout on back pan shall have a 12-1/2” x 12-1/2” cutout for electrical pull-box. Fan knockouts on top and bottom shall allow for installation of up to four 4-1/2” fans. Rack shall have 2” knockouts, 4” knockouts for Wiremold 4000 ® Series raceways, and knockouts for UCP Series universal connector panels on the side. Top, bottom and sides shall feature vertical vent pattern. DWR Series enclosures shall satisfy the 2007 & 2010 CBC; 2006, 2009 & 2012 IBC; ASCE 7-05 (2005 Edition) & ASCE 7-10 (2010 Edition) and the 2006 & 2009 editions of NFPA 5000 for use in areas of high seismicity, Seismic Use Group III, Zone 4 or Seismic Design Category (SDC) “D” with lateral force requirements for protecting 140 lbs. of essential equipment in locations with the highest level of seismicity and top floor or rooftop installations with an Importance factor (Ip) of 1.5 when used with DWRSR-ZL Latch. Rack shall be UL Listed in the US and Canada. DWR Series shall meet all enclosure requirements towards PCI DSS (Payment Card Industry Data Security Standard) Compliance. Rack shall be GREENGUARD Gold Certified. Rack shall comply with the requirements RoHS EU Directive 2002 / 95 / EC. Rack shall be manufactured by an ISO 9001 and ISO 14001 registered company. Rack shall be warrantied to be free from defects in materials or workmanship under normal use and conditions for the lifetime of the rack. Customizable specification clips available at middleatlantic.com
see inside for important information regarding useable depths
options: • Front doors shall be reinforced 16-gauge steel, model # FD-XX (solid), VFD-XX (vented, 25% open area), LVFD-XX (vented, 64% open area), PFD-XX (plexi), (XX= # of rackspaces of DWR rack) • Keyless Latch replaces keylock, fits front & rear doors, shall be models # LATCH • Rear rail kit 11-gauge, 10-32 threaded, sold in pairs, hardware included, shall be model # DWR-RRXX • Fan kits with two 4-1/2” exhaust fans, fan guards and vent blockers, shall be model # DWR-FK17 (fits DWR-xx-17), DWR-FK22 (fits DWR-xx-22), DWR-FK26 (fits DWR-xx-26), DWR-FK32 (fits DWR-xx-32) • Vent Blockers used to promote active thermal management, shall be model # VBK-D17 (fits DWR-XX-17), VBK-SD22 (fits DWR-XX-22), VBK-E20 (fits DWR-XX-26) • Optional cover plate / shelf kit shall be model # DWR-CVR • Minimum-clearance latch shall allow side-by-side or corner mounting, shall be model # DWRSR-ZL
EIA/TIA COMPLIANT US PATENT# 7, 278, 183 SEISMIC CERTIFIED
what great systems are built on.
™
middleatlantic.com | middleatlantic.ca
96-045 / rev 13e / 4-16-14
DWR Series basic dimensions
all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters]
side view
2x 2.25 [57]
front view
side view
center section
2x ko for decora style switches or devices
front view
front view
backpan: DWR-35-xx
4x 3.88 [98]
4x UHF/VHF antenna ko ø5/8” 2x UCP single module ko wiremold 4000 series raceway (see table for qty)
2x 2.06 [52] 5.06 [129] 16.06 [408]
2x 1/4-20 x 1 grounding/ bonding stud back pan
16.0 [406] typ
backpan: DWR-10-xx DWR-12-xx DWR-16-xx DWR-18-xx
5.36 [136] 2.69 [68] D
D 2 inch electrical ko (see table for qty)
shown with DWR rear rack rail kit DWR-RRxx
4x 10-32 x .5 grounding/ bonding stud center section
.625 [16] front rail setback
usable depth of equipment 15 [381]/20 [508]/ 24 [610]/30 [762]
23.4 [594]
rackrail to rackrail depth when rear mounting is required 10.250 [260] / 15.250 [387] 19.25 [489] / 25.250 [641]
C
B
CL
.50 [13] typ
2.25 [57] typ
12.50 sq. knokout
1.8 typ. [46] 16.06 [408]
see table (qty. mounting holes)
5.06 [129] 2x 2.06 [52]
11.5 [282]/ 16.5 [419]/ 20.5 [502]/ 26.5 [673]
C
3.00 [76] typ CL
B 5.87 [149]
front view backpan: DWR-21-xx DWR-24-xx
ø.41 [10]
C
17.3 [439]/ 22.3 [567] / 26.3 [668]/ 32.3 [820]
D
CL
B
Note: 17”, 22” and 32” deep models are represented in this drawing (DWR-xx-17) / (DWR-xx-22) / (DWR-xx-26) / (DWR-xx-32)
Rackspaces
Weight Capacity
2” EKO Backpan Qty.
Wiremold 4000 Series Qty.
A Wiremold 4000 Series Spacing
B Mounting Hole Spacing
C Mounting Hole Spacing Hinge Side
D Knockout Top to Mounting Hole Spacing
Qty. of Mounting Holes
10 spaces
200 lbs.
-
1
12.25 [311]
19.13 [486]
19.13 [486]
3.31 [84]
4
10 spaces
200 lbs.
-
1
12.25 [311]
19.13 [486]
19.13 [486]
3.31 [84]
4
15
12 spaces
200 lbs.
-
1
14.00 [356]
22.63 [575]
22.63 [575]
5.06 [129]
4
21.00 [533]
20
12 spaces
200 lbs.
-
1
14.00 [356]
22.63 [575]
22.63 [575]
5.06 [129]
4
28.00 [711]
21.00 [533]
24
12 spaces
200 lbs.
-
1
14.00 [356]
22.63 [575]
22.63 [575]
5.06 [129]
4
DWR-12-32
28.00 [711]
21.00 [533]
30
12 spaces
200 lbs.
-
1
14.00 [356]
22.63 [575]
22.63 [575]
5.06 [129]
4
DWR-16-17
35.00 [889]
28.00 [711]
15
16 spaces
200 lbs.
-
1
17.50 [445]
29.63 [752]
29.63 [752]
8.56 [217]
4
DWR-16-22
35.00 [889]
28.00 [711]
20
16 spaces
200 lbs.
-
1
17.50 [445]
29.63 [752]
29.63 [752]
8.56 [217]
4
DWR-18-17
38.50 [978]
31.50 [800]
15
18 spaces
250 lbs.
-
1
19.25 [489]
33.13 [841]
33.13 [841]
10.31 [262]
4
DWR-18-22
38.50 [978]
31.50 [800]
20
18 spaces
250 lbs.
-
1
19.25 [489]
33.13 [841]
33.13 [841]
10.31 [262]
4
DWR-18-26
38.50 [978]
31.50 [800]
24
18 spaces
250 lbs.
-
1
19.25 [489]
33.13 [841]
33.13 [841]
10.31 [262]
4
DWR-18-32
38.50 [978]
31.50 [800]
30
18 spaces
250 lbs.
-
1
19.25 [489]
33.13 [841]
33.13 [841]
10.31 [262]
4
DWR-21-17
43.75 [1111]
36.75 [933]
15
21 spaces
250 lbs.
4
2
10.56 [268]
38.33 [975]
19.19 [487]
12.94 [329]
4
DWR-21-22
43.75 [1111]
36.75 [933]
20
21 spaces
250 lbs.
4
2
10.56 [268]
38.33 [975]
19.19 [487]
12.94 [329]
4
DWR-24-17
49.00 [1245]
42.00 [1067]
15
24 spaces
300 lbs.
4
2
10.56 [268]
43.63 [1108]
21.81 [554]
15.56 [395]
5
DWR-24-22
49.00 [1245]
42.00 [1067]
20
24 spaces
300 lbs.
4
2
10.56 [268]
43.63 [1108]
21.81 [554]
15.56 [395]
5
DWR-24-26
49.00 [1245]
42.00 [1067]
24
24 spaces
300 lbs.
4
2
10.56 [268]
43.63 [1108]
21.81 [554]
15.56 [395]
5
DWR-24-32
49.00 [1245]
42.00 [1067]
30
24 spaces
300 lbs.
4
2
10.56 [268]
43.63 [1108]
21.81 [554]
15.56 [395]
5
DWR-35-17
68.25 [1734]
61.25 [1558]
15
35 spaces
300 lbs.
4
2
10.56 [268]
62.83 [1597]
21.00 [533]
25.19 [640]
6
DWR-35-22
68.25 [1734]
61.25 [1558]
20
35 spaces
300 lbs.
4
2
10.56 [268]
62.83 [1597]
21.00 [533]
25.19 [640]
6
DWR-35-26
68.25 [1734]
61.25 [1558]
24
35 spaces
300 lbs.
4
2
10.56 [268]
62.83 [1597]
21.00 [533]
25.19 [640]
6
Part #
Overall Height
Racking Height
Useable Depth
DWR-10-17
24.50 [622]
17.50 [445]
15
DWR-10-22
24.50 [622]
17.50 [445]
20
DWR-12-17
28.00 [711]
21.00 [533]
DWR-12-22
28.00 [711]
DWR-12-26
what great systems are built on.
™
middleatlantic.com | middleatlantic.ca
DWR Series basic dimensions
all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters]
top view
(knockout pictured in top view are also on the bottom view) 2x 14.0 [356] 2x 2.63 [67]
7.5 [191]
2x 1.82 [46]
4x UHF / VHF antenna KO 5/8” 1.72 [44]
2x 2.81 [71] grounding / bonding stud
2x 2.05 [52]
2x 1.32 [34]
2x 2.57 [65]
2x 1.0 x 1.5 EKO
2x 2.00 EKO 2x 3.00 EKO
2x .5 x .75 EKO
2x 4.5 fan knockouts
Useable Depth Useable depth extends into backpan. Consider this when applications require large amounts of cables, connectors and/or conduit in the backpan
center section clearance 8.65 [220] / 13.65 [347] / 17.65 [448] / 23.65 [601]
A
29.8 [757] / 32.5 [826] 35.1 [892] / 39.6 [1006]
B Part #
A Overall Height
B Center Section Depth
C Useable Depth
DWR-xx-17
17.3 [439]
11.5 [292]
15.0 [381]
DWR-xx-22
22.3 [567]
16.5 [419]
20.0 [508]
DWR-xx-26
26.3 [668]
20.5 [521]
24.0 [610]
DWR-xx-32
32.3 [820]
26.5 [673]
30.0 [762]
C
what great systems are built on.
™
middleatlantic.com | middleatlantic.ca
DWR Series
with minimum-clearance latch installed basic dimensions all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters]
top view
top view
(2 DWR’s fully opened)
23.4 [594]
64.0 [1626] / 74.0 [1880] / 82.0 [2083] / 94.0 [2388]
17.3 [439] 22.3 [567] 26.3 [668] 32.3 [820]
top view
(2 DWR’s closed position) .25 [6] minimum clearance required between DWR’s using minimum-clearance latches
optional DWRSR-ZL minimum-clearance latch operation:
47.05 [1195] DWR shown with optional minimumclearance latch (DWRSR-ZL) installed
Center Section Trim Power
Part #
PD-815 Series (Qty)
PD-2415 Series (Qty)
DWR-10-xx
1
N/A
DWR-12-xx
1
N/A
DWR-16-xx
1
N/A
DWR-18-xx
1
N/A
DWR-21-xx
1 or 2
N/A
DWR-24-xx
1 or 2
N/A
DWR-35-xx
1 or 2
1
what great systems are built on.
™
middleatlantic.com | middleatlantic.ca
LOWELL Manufacturing Company
Spec No. 1095
Model: 4-step sequential power panels Description: 19”W rackmount panel with 4-step sequential power, optional surge suppression and alarm interface is available with rocker or key-switch activation. Steel chassis has a total of 9 outlets (6 switched, 3 unswitched) for sequential activation/deactivation of connected equipment. Delay between sequenced steps can be adjusted (0.5-10 seconds) using a small screwdriver (not included) to avoid unintended changes. ETL-listed in the U.S. and Canada to UL Standard 60065, panel has a power rating of 120V AC, 60Hz/20A with EMI/RFI filtering. Includes 9-ft. cord with NEMA 5-20P plug. Rear termination blocks accommodate remote switches, external triggers and an alarm system interface for use where mandated by fire code. Includes two dry contact closures (steps 5 and 6) for triggering remote power control units (RPC-series units not included). Switches can be overridden for life safety systems where fire code mandates an alarm interface. Some models also include optional surge suppression function that defeats surges up to 72,000A and is UL1449-2 / ANSI C62.41-compliant. Features: • Total of 9 outlets: 6 switched (2-single on back, 2-duplex on back); 3 unswitched (1-single on front, 2-single on back). • Power Rating: 120VAC, 60Hz, 20A (each receptacle rated 15A) • Actuation Switch: front panel rocker- or key-switch with momentary contacts (normally open SPST) plus rear barrier strip termination blocks for momentary (normally open) remote switches. • Alarm Interface: lock on, lock off and switch lock functions for alarm system or master control panel applications. • External Control Connections: plug-in barrier strip terminal blocks • EMI/RFI Filter: 19dB@500kHz, 42dB@30MHz • Dimensions: 19"W x 1.75"H (1U) x 9"D • Made in the U.S.A. Optional: • Advanced Surge Suppression: (see models in chart) UL1449-2 adjunct results: 1000 surges, 6000 volts, 3000A, C1 and B3 waveforms (IEEE C62.41), no failures. – LEDs indicate status: if one section of the surge suppressor has reduced protection, there are two additional sections available to safeguard equipment.
REV. 11.12.13 (pg. 1/2)
The 19" EIA rackmount power panel is available with a key switch or rocker switch (shown). This model also includes the optional surge suppression function.
Panel includes 9-ft. cord with NEMA 5-20P plug.
– Initial Clamping Voltage: 205V, UL rating 330V – Endurance: IEEE C62.41-1991, B3 (C1), Pulses (lifetime): 1kv≥1,000,000; 3kv≥100,000; 6kv≥5000 – Transient Noise Reduction: 25dB@100kHz, 50dB@1MHz – Response Time: less than 5 nanoseconds – Applicable Standards: IEEE standard 587-80 A & B, IEEE standard C62.41-1991, IEC 1000-4-5-1995 (IEC 801-5). – Protection Mode: line to neutral, zero ground leakage. A & E Specifications: The sequential AC rackmount power panel shall be Lowell Model _________. It shall be ETL-listed and have a power rating of 120VAC, 60Hz/20A with EMI/RFI filtering and a total of 9 outlets (6 switched, 3 unswitched) and 2 steps providing contact closures to sequentially activate/deactivate equipment (46 steps) with a sequence delay of 0.5 to 10 seconds. It shall be housed in a 1U rackmount chassis with color-coded LEDs. Front activation shall be via a _________ (rocker or key) switch. [OPTIONAL: It shall provide surge protection .]
Model No.
Description
ACR-SCS4-2009-RT2
20A – AC Rackmount Panel (1U) with sequencing, remote control, rocker-switch
ACR-SCS4-2009K-RT2
20A – AC Rackmount Panel (1U) with sequencing, remote control, key-switch
ACSPR-SCS4-2009-RT2
20A – AC Rackmount Panel (1U) with sequencing, remote control, advanced surge suppression, rocker-switch
ACR-2009-SPSQK
20A – AC Rackmount Panel (1U) with sequencing, remote control, advanced surge suppression, key-switch
©2013 Lowell Manufacturing Company, 100 Integram Dr., Pacific MO 63069 | 800.325.9660 | www.lowellmfg.com | Lowell makes every effort to provide accurate information while reserving the right to change specifications and/or improve manufacturing methods without notification.
Spec No. 1095 REV. 11.12.13 (pg. 2/2)
Panel is available with rocker or key-switch.
Front
Unswitched Surge Remote Suppression Trigger Surge Suppression
Activated
Red LED flashes when cycling down and remains lit when system is off. Green LED flashes when cycling up and remains lit when system is on.
Circuit Breaker
15A 1800W max
Optional surge suppression function with LEDs that indicate if there is full or reduced protection.
Rear 120VAC 60Hz 20A 2400W
Unswitched
1
Switched
2
Switched 3
Switched 4
TOP CLOSURE PANELS Includes 9-ft. cord with NEMA 5-20P plug.
ALARM SYSTEM INTERFACE If required by local building code, facility usage, or the Fire Marshal; the system switches can be overridden and the system controlled by contact closures provided by the fire alarm panel or other control system. A maintained contact between the “com” terminal and any of the terminals shown here will provide the following functions. Lock Off: A maintained contact between the “COM” terminal and the “LOCK-OFF” terminal will turn the system off and keep it off regardless of other switch activations. If the system is already off, it will be kept off. Lock On: A maintained contact between the “COM” terminal and the “LOCK-ON” terminal will turn the system on and keep it on regardless of other switch activations. If the system is already on, it will be kept on. Switch Lock: A maintained contact between the “COM” terminal and the “SWITCH-LOCK” terminal will lock the system in its current state, either on or off, regardless of any other switch activations. Caution: Do not allow alarm system to make more than one of the contacts described above at the same time. Controller board damage may result.
RPC TRIGGER CONNECTIONS Multiple RPC-series remote power control units can be connected to outputs 5 and 6 (60 max. each, dependent upon limits of electrical panel). Order RPC units separately.
REMOTE SWITCH CONNECTIONS Connect a maximum of 5 remote MOMENTARY switches. Order switches separately.* Four conductors (2 LED switch).
RPC-series remote power controls.
Three conductors (1 LED switch).
* See momentary switches: • Models with 2 LEDs: RPSB2-MP, RPSB2-MKP, RPSW2-MP, RPSW2-MKP, RPSB2-MR, RPSB2-MKR • Models with 1 LED: RPSB-MP, RPSB-MKP, RPSW-MP, RPSW-MKP, RPSB-MR, RPSB-MKR
Maximum wire distances: 24-ga 20,000 ft. (approximately 3.5 miles); 22-ga. 31,200 ft. (approx. 5.5 miles); 18-ga. 76,800 ft. (approx. 13.5 miles).
©2013 Lowell Manufacturing Company, 100 Integram Dr., Pacific MO 63069 | 800.325.9660 | www.lowellmfg.com | Lowell makes every effort to provide accurate information while reserving the right to change specifications and/or improve manufacturing methods without notification.
Models: RPC-1 series
Remote Power Controls – low-voltage, surface-mount Description: Lowell RPC-1 series UL Listed remote power controls may be combined with a variety of switches, modules, and/or sequential control devices (manufactured by Lowell or others) to provide a versatile low-voltage method of turning specific equipment on and off from a remote location. The ability to safely control AC power distribution without directly accessing equipment minimizes the potential for accidental or unauthorized system modifications or vandalism. System integration applications include commercial, educational, entertainment, government, and religious facilities where remote power control is required.
Models with cord: RPC-1
RPC-1-20A-CD
RPC-1 controls are typically installed in rear of rack, in close proximity to equipment that is to be remotely switched. Low-voltage, 3- or 4-conductor cable is then run from the RPC-1 terminal strip to a control switch such as Lowell RPS-series wall or rackmount switches. Systems may also be configured with multiple RPC-1 controls activated by a single switch (application 1) or with one or more RPC-1 controls activated by multiple switches (application 2). RPC-1 controls are also a key component in Lowell's SCS-series modular low voltage sequential control systems. Each RPC1 assembly includes a power supply and relay with selection of outlet and termination styles to meet application needs. All models are housed in a steel chassis finished in black powder epoxy. Assemblies are ETL Listed (UL 813).
RPC-1-TVSS-CD
Models with metal-clad whip: RPC-1-20A-MC
RPC-1-TVSS-MC
• Low voltage power controls combine with low voltage switches to achieve remote on/off triggering of AC equipment. • Compact size surface mounts nearly anywhere • Low voltage connections allow for cost effective wiring/installation.
RPC-1-30A-MC
RPC-1-IG-MC
• 15A, 20A and 30A models meet multiple application needs • Termination styles include 6-ft. cord or 6-ft. flexible whip • ETL Listed in the U.S. and Canada • Made in the U.S.A. Model-specificfeatures: • No.RPC-1: 15A duplex receptacle, 6-ft. cord
• No.RPC-1-20A-MC:20A duplex receptacle, 6-ft. metal-clad whip.
• No.RPC-1-20A-CD: 20A duplex receptacle, 6-ft. cord.
• No.RPC-1-IG-MC:20A duplex receptacle with isolated ground • No.RPC-1-TVSS-CD: 20A duplex outlet with common mode protection to minimize potential for ground loop and noise problems. 6-ft. metal-clad whip. transient voltage surge suppressor, 6-ft. cord. • No.RPC-1-TVSS-MC: 20A duplex outlet with common mode • No.RPC-1-30A-MC: 30A twistlock receptacle, mating plug, 6-ft. metal-clad whip. transient voltage surge suppressor, 6-ft. metal-clad whip. Model Description Models with cord: RPC-1 Power control, low-voltage RPC-1-20A-CD Power control, low-voltage RPC-1-TVSS-CD Power control, low-voltage Models with metal-clad whip: RPC-1-TVSS-MC Power control, low-voltage RPC-1-20A-MC Power control, low-voltage RPC-1-IG-MC Power control, low-voltage RPC-1-30A-MC Power control, low-voltage
Power Rating
Outlet Type
Size
Termination Switch Type
Other
15A, 125VAC 20A, 125VAC 20A, 125VAC
1 duplex 1 duplex 1 duplex
7.5"L x 3.25"W x 1.75"H 7.5"L x 3.25"W x 2.75"H 7.5"L x 3.25"W x 2.75"H
6 foot cord 6 foot cord 6 foot cord
Dry contact* Dry contact* Dry contact*
— — Surge suppressor**
20A, 125VAC 20A, 125VAC 20A, 125VAC 30A, 125VAC
1 duplex 1 duplex 1 iso-grd duplex 1 twist lock
7.5"L x 3.25"W x 2.75"H 7.5"L x 3.25"W x 2.75"H 7.5"L x 3.25"W x 2.75"H 7.5"L x 3.25"W x 2.75"H
6 foot whip 6 foot whip 6 foot whip 6 foot whip
Dry contact* Dry contact* Dry contact* Dry contact*
Surge suppressor** — — Mating plug included
*Minimum rating 30 vdc, 40 mA. **Common mode (L-G, L-N, N-G) surge suppressor for transient voltage meets UL1449 for suppression; UL1283 for noise filtering. NOTE:ModelNo.RPC-1-TVSS-MChasbeendiscontinuedandisavailableinlimitedquantities.Seenewmodelno.RPC-20-S-HWonspecno.1204
Spec. No. 1c-301 (rev. 4.2.14) pg. 1 of 2
©2014 Lowell Manufacturing Company, 100 Integram Dr., Pacific MO 63069. Phone–800.325.9660 Fax—636.257.6606. Lowell makes every effort to provide accurate information while reserving the right to change specifications and/or improve manufacturing methods without notification. (lowellmfg.com)
A&ESpecifications: Device for remotely controlling AC power shall be Lowell remote power control Model ____________. Device shall include a power supply and relay housed within a 7.5"L x 3.25"W x _______H (1.75", 2.75") steel chassis. Unit shall include one (1) ________ (duplex, isolated ground duplex, twist-lock) outlet with a power rating of _____(15A, 20A, 30A). Power control device shall terminate with a _______(6-ft. cord, 6-ft. flexible whip). Device _______ (shall, shall not) include surge protection for transient voltage. SingleSwitchApplications: Remote switching device for single switch applications shall be Lowell RPS-series maintained contact wall switch Model ________ or maintained contact rackpanel model _______.
SystemAccessories:Order Separately Remote Switches - Maintained Closure (single switch use) - keylock also available RPSW-P Switch SPST rocker w 1LED maintained 1 ga wallplate RPSB-R Switch SPST rocker w 1LED maintained 1U rackpanel Remote Switches - Momentary Closure (multiple switch use) - keylock also available RPSW-MP Switch SPST rocker w 1LED momentary 1 ga wallplate RPSW2-MP Switch SPST rocker w 2LED momentary 1 ga wallplate RPSB-MR Switch SPST rocker w 1LED momentary 1U rackpanel RPSB2-MR Switch SPST rocker w 2LED momentary 1U rackpanel Momentary Switch Module (req. for multiple momentary switches) MSM2 Momentary switch module for multiple switches
MultipleSwitchApplications: To remotely control one or more RPC units, Lowell momentary switch module Model MSM2 and Lowell RPS-series momentary contact wall switch Model __________ or momentary rackpanel switch model _______shall be used.
Application1:One or multiple RPC controls activated by a single maintained switch To AC power
Equipment to be switched
RPSSeries MaintainedSwitch Stays on until turned off Connect to additional RPC units (if required) Remote PowerControl RPC-1 shown 2-conductor cable 3-conductor cable (mic line works nicely - use shield as common) Wiring Notes: Maximum distance between switch and RPC is: 22 ga: Max distance is 6,600 ft. (1.25 miles), 18 ga: Max distance is 17,160 ft. (3.25 miles)
Application2:One or multiple RPC controls activated by multiple momentary switches RPSSeries MomentarySwitch Releases after being pushed (single LED models use 3-conductors)
MomentarySwitchModule Model MSM2
Equipment to be switched
Remote PowerControl Model RPC-1 shown. Additional RPC units may be added. Connect Com and SW terminals only. RPSSeries MomentarySwitch Releases after being pushed (dual LED models use 4-conductors)
Connect to additional RPC units (if required) The MSM2 includees two remote switch terminal blocks. Terminals are parallel - connected internally. Additional switches may be added by making parallel connections at MSM2, at remote switch or anywhere along switch wiring (max 6 total)
Wiring Notes: Maximum distance between switches, MSM2 and RPC is: 22 ga: Max distance is 6,600 ft. (1.25 miles), 18 ga: Max distance is 17,160 ft. (3.25 miles)
Spec. No. 1c-301 (rev. 4.2.14) pg. 2 of 2
©2014 Lowell Manufacturing Company, 100 Integram Dr., Pacific MO 63069. Phone–800.325.9660 Fax—636.257.6606. Lowell makes every effort to provide accurate information while reserving the right to change specifications and/or improve manufacturing methods without notification. (lowellmfg.com)
Control Cable
Technical Data Sheet Communication Cables 2833 West Chestnut Street Washington, PA 15301 Toll Free: (800) 245-4964 Fax: (724) 222-6420 www.westpenn-wpw.com
PART NUMBER:
272
DESCRIPTION:
22/10 Stranded bare copper conductors, unshielded with an overall jacket.
NEC RATING:
CMR, NEC Article 800
APPROVALS:
(UL) C(UL) Listed or c(ETL)us Listed
APPLICATION:
Indoor for: Intercom, Security, Sound, Audio, Background Music, and Power Limited Control Circuits.
Construction Parameters: Conductor Stranding Insulation Material Insulation Thickness Number of Conductors Shield Drain Jacket Material Jacket Thickness Overall Cable Diameter Approximate Cable Weight Flame Rating
22 AWG Bare Copper 7x30 PVC 0.007'' Nom. 10 None None PVC 0.017'' Nom. 0.218'' Nom. 34.1 Lbs/1M' Nom. UL 1666 Riser Flame Test
Electrical & Environmental Properties: Temperature Rating Operating Voltage Max.Capacitance Between Conductors @ 1 KHz DC Resistance per Conductor @ 20deg C Insulation Colors Jacket Color RoHS Compliant
-20°C To +60°C 300 V RMS 25 pf/ft Nom. 17 Ohms/1M' Nom. Black, Red, White, Green, Brown, Blue, Orange, Yellow, Purple, Gray Gray Yes
Mechanical Properties: Max. Recommended Pull Tension Min. Bend Radius (Install)
91 lbs. 2.25”
Specification Issue Date: 7/06 This document is the property of West Penn Wire. . The information contained herein is considered Proprietary and not to be reproduced by any means Without written consent of West Penn Wire
Standard Lengths are 1000ft. The Jacket is sequentially footmarked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise.
Technical Data Sheet Communication Cables 2833 West Chestnut Street Washington, PA 15301 Toll Free: (800) 245-4964 Fax: (724) 222-6420 www.westpenn-wpw.com
PART NUMBER:
452
DESCRIPTION:
22/2 Stranded tinned copper conductors, shielded with an overall jacket.
NEC RATING:
CMR, NEC Article 800
APPROVALS:
(UL) C(UL) Listed or c(ETL)us Listed
APPLICATION:
Indoor for: Intercom, Security, Sound, Audio, Background Music, and Power Limited Control Circuits.
Construction Parameters: Conductor Stranding Insulation Material Insulation Thickness Number of Conductors Shield Drain Jacket Material Jacket Thickness Overall Cable Diameter Approximate Cable Weight Flame Rating
22 AWG Tinned Copper 7x30 Polypropylene 0.08'' Nom. 2 100% Aluminum Polyester Foil Stranded Tinned Copper PVC 0.020'' Nom. 0.135'' Nom. 14 Lbs/1M' Nom. UL 1685 Vertical Tray
Electrical & Environmental Properties: Temperature Rating Operating Voltage Max.Capacitance Between Conductors @ 1 KHz Capacitance Between Conductors to Shield @ 1 KHz DC Resistance per Conductor @ 20deg C Insulation Colors Jacket Color RoHS Compliant
-300 V RMS 32 pf/ft Nom. 58 pf/ft Nom. 17 Ohms/1M' Nom. Black, Red, White Black Yes
Mechanical Properties: Max. Recommended Pull Tension Min. Bend Radius (Install)
24 Lbs. 1.3”
Specification Issue Date: 7/06 This document is the property of West Penn Wire. . The information contained herein is considered Proprietary and not to be reproduced by any means Without written consent of West Penn Wire
Standard Lengths are 1000ft. The Jacket is sequentially footmarked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise.
Outdoor Speaker Cable
Technical Data Sheet Aquaseal ® Fire-Alarm Cables 2833 West Chestnut Street Washington, PA 15301 Toll Free: (800) 245-4964 Fax: (724) 222-6420 www.westpenn-wpw.com
PART NUMBER:
AQ227
DESCRIPTION:
12/2 Stranded bare copper conductors, overall unshielded with Aquaseal tape and overall jacket.
NEC RATING:
FPL – PLTC, CL3 NEC Article 760 And 725
APPROVALS:
(UL) Listed – Direct Burial
APPLICATION:
Materials suitable for outdoor use, and indoor trays, allows a variety of uses for (Low voltage industrial process control circuits, Power-Limited circuits, Power-Limited fire alarm circuits, PowerLimited tray cable PLTC)
Construction Parameters: Conductor Stranding Insulation Material Insulation Thickness
12 AWG Bare Copper 19x25 PVC with Nylon PVC 0.015'' Nom. Nylon .005” Nom. 2 (1 Pair) None None 2 Ply water swellable tape Sunlight/ Moisture Resistant PVC 0.040'' Nom. 0.340'' Nom. 78 Lbs/1M' Nom. UL 1685 Vertical Tray
Number of Conductors Shield Drain Water-Blocking Tape Jacket Material Jacket Thickness Overall Cable Diameter Approximate Cable Weight Flame Rating
Electrical & Environmental Properties: Temperature Rating Operating Voltage Max.Capacitance Between Conductors @ 1 KHz DC Resistance per Conductor @ 20deg C Insulation Colors Jacket Color RoHS Compliant TIA455-82B Water Infiltration Test Compliant UL 444 & 13 Compliant
-20deg C to 90deg C 300 V RMS 36 pf/ft Nom. 1.7 Ohms/1M' Nom. Black, Red Black -Yes Yes
Mechanical Properties: Max. Recommended Pull Tension Min. Bend Radius (Install)
Specification Issue Date: 7/06 This document is the property of West Penn Wire. . The information contained herein is considered Proprietary and not to be reproduced by any means Without written consent of West Penn Wire
146 lbs. 3.4” Standard Lengths are 1000ft. The Jacket is sequentially footmarked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise.