Preview only show first 10 pages with watermark. For full document please download

Adf240c

   EMBED


Share

Transcript

VER : A_4 update : 2015.11.17 AC-DC Din Rail Power Supply ADF240C 240 Watts KEY FEATURES  Protections: Short Circuit / Overload / Over Voltage / Over Temperature  With P.F.C. Function, PF>0.95  Free Air Convection  High Efficiency up to 91%  Can be Connected in Parallel to Offer the Current Share Function  Built-in DC OK Relay Contact  3-Year Product Warranty ELECTRICAL SPECIFICATIONS All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated. Model No. ADF240C-24S Max Output Wattage (Free air Convection) Voltage Input Output Function Isolation Environment Physical Safety & EMC 90-264 VAC or 120-370 VDC Frequency (Hz) 47-63 Hz Current (Full load) <3.0 A max. (115 VAC) / <1.5 A max. (230 VAC) Inrush Current (<2ms) <30 A max. (115 VAC) / <60 A max. (230 VAC) Leakage Current < 1.5 mA max. Power Factor PF>0.98 (115 VAC) / PF>0.94 (230 VAC) at Full Load Voltage (V.DC.) 24V Trim ±2% (Adjustable VR on the front panel) Voltage Accuracy ±2% Current (Free air Convection) (A) (max.) 10 Line Regulation ±0.5% Load Regulation ±2% Minimum Load 2% Maximum Capacitive Load 6000 uF Ripple & Noise (max.) 150mVp-p Efficiency (typ.) Protection ADF240C-48S 240W (W) (at 230 VAC) (Note 4) 48V 5 1200 uF 90% 91% Hold-up Time 20 ms (115 VAC) / 20 ms (230 VAC) at Full Load Over Power Protection Auto recovery, Hiccup mode Over Voltage Protection 27~31V (Latch Off) Over Temperature Protection Auto recovery Short Circuit Protection Auto recovery, Hiccup mode 52~56V (Latch Off) DC OK Relay Contact Ratings (max.) 30Vdc/1A, 30Vac/0.5A Resistive Load Input-Output (V.AC) 3000VAC or 4242VDC Input-FG (V.AC) Output-FG (V.AC) Operating Temperature 1500V 500V -40°C…+70°C (with derating) Storage Temperature -40°C…+85°C Temperature Coefficient ±0.05%/°C Humidity 95% RH MTB >169K h @ 25°C (MIL-HDBK-217F) Vibration 10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes. Dimension (L x W x H) 2.56 x 4.96 x 4.25 Inches Weigh 850 g ( 65.0 x 126.0 x 108.0 mm ) Tolerance 0.5 mm Cooling Method Free convection Agency Approvals CE(EN 60950-1) Isolation Rsistance EMI (Conducted & Radiated Emission) I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25°C / 70% RH EMS (Noise Immunity) http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 EN 55022 class B EN61000-4-2,3,4,5,6,8,11, EN 55024, EN 61000-6-2, EN 61204-3, Heavy Industry Level, Criteria A -1- VER : A_4 update : 2015.11.17 AC-DC Din Rail Power Supply ADF240C 240 Watts NOTE 1. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor. 2. The power supplies can connected in parallel to offer the current share function. 3. Derating may be needed under low input voltage. Please check the derating curve for more details. 4. After 30 minutes of burn-in 5. Parallel Operation with Remote Sensing: (1). Parallel operation is available by connecting the units shown as below (+S,-S and CS are connected mutually in parallel) (2). Difference in Vout among parallelled units should be less than +/-1% (3). The total output current must not exceed the value determined by the following equation (Output current at parallel operation)=(The rated current per unit) x (Number of unit) x 0.9. (4). In parallel operation 4 units is the maximum, please consult the manufacture for other applications. (5). When remote sensing is used in parallel operation, the sensing wire must be connected only to the master unit. (6). When in parallel operation, the minimum output load should be greater than 3% of total output load.(Min. load > 3% rated current per unit x number of unit) 6. Please refer to our PDF file "AC-DC Application" on our website: www.archcorp.com.tw 7. Strongly recommend to conduct this test with DC Voltage. If customer wishes to test with AC Voltage, please disconnect all Y-Capacitors within Arch power supply. http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -2- VER : A_4 update : 2015.11.17 AC-DC Din Rail Power Supply ADF240C 240 Watts DERATING BLOCK DIAGRAM MECHANICAL DIMENSION ( Top View ) P1 DC OK RELAY CONTACT Contact Close PSU Turns Off / DC Fail Contact Open PSU Turns On / DC Ok Contact Ratings (max.) PIN# Single 1 +DC OK 2 CS 3 +S 4 -S 5 +DC OUT 6 +DC OUT 7 -DC OK & GND 8 GND 30V / 1A Resistive Load P2 PIN# Single 9 http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 10 AC IN (N) 11 AC IN (L) -3- VER : A_4 update : 2015.11.17 AC-DC Din Rail Power Supply ADF240C 240 Watts EFFICIENCY VERSUS LOAD ADF240C-24S VIN Input Voltage (V) Efficiency (%) VS Efficiency VS Efficiency 90 115 180 230 264 Load (%) 10 20 30 40 50 86.21 87.63 89.91 90.57 90.80 115V (%) 78.36 84.91 86.93 87.58 88.20 230V (%) 77.68 83.98 87.27 88.85 86.60 Load (%) 60 70 80 90 100 115V (%) 88.34 88.30 88.38 88.19 87.73 230V (%) 90.03 90.35 90.50 90.59 90.52 92.00% 100.00% 91.00% 90.00% 90.00% 80.00% 70.00% 89.00% 60.00% 88.00% EF F % EFF% LOAD 87.00% 50.00% 40.00% 86.00% 30.00% 85.00% 20.00% 10.00% 84.00% 0.00% 83.00% 90V 115V 180V 230V 0% 264V 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD VIN ADF240C-48S VIN Input Voltage (V) Efficiency (%) VS Efficiency LOAD VS Efficiency 90 115 180 230 264 Load (%) 10 20 30 40 50 87.49 89.73 91.24 91.84 92.15 115V (%) 80.72 84.05 86.67 88.01 88.55 230V (%) 77.16 82.91 86.97 88.96 90.05 Load (%) 60 70 80 90 100 115V (%) 89.15 89.46 89.84 89.68 89.87 230V (%) 90.51 91.05 91.21 91.55 91.84 93.00% 100.00% 92.00% 90.00% 80.00% 91.00% 70.00% 90.00% EFF% EFF% 60.00% 89.00% 88.00% 50.00% 40.00% 30.00% 87.00% 20.00% 86.00% 10.00% 0.00% 85.00% 90V 115V 180V 230V VIN http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 264V 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD -4-