ADPT-NN-A16-μPA16 16-Electrode NeuroNexus Probe A16 Adapter for μPA16 Preamplifier Connecting the μPA16 via Adapter ADPT-NN-A16-μPA16 to the NeuroNexus Probe
μPA16
ADPT-NN-A16-μPA16
NeuroNexus Probe A16
Pin Layout of the Omnetics Connector on the lower side of the ADPT-NN-A16-μPA16
Connector for NeuroNexus Probe ADAPTER Omnetics Connector
9
7
5
3
1
G
GP 16 14 12 10
8
6
4
2
GP
R
15 13 11
Shown are the output pins of the adapter that are connected to the micro preamplifier μPA16 when looking directly at the pins. The labeled channels are the ground channels (G), the reference channel (R), and two guide posts (GP) and the 16 recording channels (1 to 16) of the μPA16. Please see the μPA manual for details. Important: Operation of the μPA16 is differential. The reference channel R has to be used for obtaining a proper signal. Please see the μPA manual for details.
!
Warning: The device may only be used together with the μPA16 preamplifier from Multi Channel Systems MCS GmbH and the 16-channel probe from NeuroNexus, and only for the specified purpose. Damage of the device and even fatal injuries can result from improper use.
Multi Channel Systems MCS GmbH Aspenhaustrasse 21 72770 Reutlingen Germany
Fon +49-7121-9 09 25- 0 Fax +49-7121-9 09 25-11
© 2014 Multi Channel Systems MCS GmbH
[email protected] www.multichannelsystems.com
Product information is subject to change without notice.
ADPT-NN-A16-μPA16 16-Electrode NeuroNexus Probe A16 Adapter for μPA16 Preamplifier Connecting the μPA16 via Adapter ADPT-NN-A16-μPA16 to the NeuroNexus Probe
Connector for NeuroNexus Probe A16 ADPT-NN-A16-μPA16 Important: Back side (without housing) of µPA16 faced down !
Omnetics Connector μPA16 Preamplifier
Side view without probe
Please connect the μPA16 to the Omnetics connetor at the lower side of the ADPT-NN-A16-μPA16 that the back side of the preamplifier, the one without housing is facing down. Because of the guide posts no other connection is possible.
Top view without probe
16 15 14 13 12 11 10 9 R
1 2 3 4 5 6 7 8 G
NeuroNexus A16 Probe Channel assignment of the ADPT-NN-A16-μPA16: Input pins connected to the NeuroNexus A16 probe Pin Layout for MC_Rack: NN A16 MC_Rack
NN A16 MC_Rack
Pin 16 Pin 15 Pin 14 Pin 13 Pin 12 Pin 11 Pin 10 Pin 9 Pin R
Pin Pin Pin Pin Pin Pin Pin Pin Pin
Channel 15 Channel 13 Channel 11 Channel 9 Channel 16 Channel 14 Channel 12 Channel 10 REF
1 2 3 4 5 6 7 8 G
Channel Channel Channel Channel Channel Channel Channel Channel GND
1 3 5 7 2 4 6 8
Shown are the input pins of the adapter that are connected to the NN A16 probe. The labeled channels are the ground channel (G), the reference channel (R), which are connected and the 16 recording channels (1 to 16) of the NN A16. If you use MC_Rack for data acquisation, please see the channel assignment above. Ground and Reference have been connected together as factory-default settings. You can change this connection to meet your requirements.
Multi Channel Systems MCS GmbH Aspenhaustrasse 21 72770 Reutlingen Germany