Preview only show first 10 pages with watermark. For full document please download

Aemc Clamp-on Power Meters Megger Clampmeters

   EMBED


Share

Transcript

AEMC Clamp-On Power Meters • Use on single & 3-phase power to 3MW • Measure to 1000V AC, DC or AC+DC • Automatic AC or DC selection • Ω, Hz & THD measurements • 10,000 count electroluminescent display • Fast (1msec) inrush current capture • 1000V CAT IV & IP54 rated • Data storage & Bluetooth communication • 1.89" or 2.36" jaw opening 607  ORDERING INFORMATION AE/2139.50 AE/2139.51 AE/2139.60 AE/2139.61 Model 405 (TRMS, 1000Vac/dc, 1000Aac/1500Adc, Power, THD) Model 407 (TRMS, 1000Vac/dc, 1000Aac/ 1500Adc, Energy, Harmonics, Power, THD, Recording) Model 605 (TRMS, 1000Vac/dc, 2000Aac/3000Adc, Power, THD) Model 607 (TRMS, 1000Vac/dc, 2000Aac/3000Adc, Energy, Harmonics, Power, THD, Recording) SPECIFICATIONS MODEL Measurement Method Automatic AC/DC Detection A AC A DC A AC+DC Best A Accuracy V AC V DC V AC+DC Best V Accuracy Hz Current Hz Voltage Ohm Audible Continuity Diode Test Power Values Active Power Reactive Power Apparent Power FP / DPF THDf / THDr Frequency Analysis Phase Rotation (2-wire) True InRush® current Hold, Min/Max, +/-Peak REL ΔX / Diff. ΔX/X (%) Jaw Opening Number of Values Displayed Data Recording Communication Interface Dimensions 405 407 605 607 TRMS AC/AC+DC/DC TRMS AC/AC+DC/DC – Yes Yes 0.15 to 1000A (1500A peak) 0.15 to 2000A (3000A peak) 0.15 to 1500A 0.15 to 3000A 0.15 to 1000A (1500A peak) 0.15 to 2000A (3000A peak) 1% of Reading + 3 cts 0.15 to 1000V (1400V peak) 0.15 to 1400V 0.15 to 1000V (1400V peak) 1% of Reading + 3 cts 5.0 to 2000Hz 5.0 to 20.00kHz 0.1Ω to 99.99kΩ Adjustable Fixed <40Ω Adjustable Fixed <40Ω Yes – Yes – Single Phase & Total 3-phase Single Phase & Total 3-phase 5W to 1000kW 5W to 2000kW 5var to 1000kvar 5var to 2000kvar 5VA to 1000kVA 5VA to 2000kVA Yes / No Yes / Yes Yes / No Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes – 25th order – 25th order Yes – Yes – Yes Yes Yes Yes Yes Yes Yes Yes – Yes / Yes – Yes / Yes 1.89" (48mm) 2.36" (60mm) 1 3 1 3 – Yes – Yes – Bluetooth – Bluetooth 10.70 x 3.62 x 1.61" (272x92x41mm) 11.65 x 4.37 x 1.61" (296x111x41mm) Megger Clampmeters FORK MULTIMETER • Open jaw AC current to 200A • 0.1V to 1000V AC/DC • Resistance to 20MΩ • Continuity buzzer & diode check • Autoranging • Non-contact AC voltage detection LEAKAGE CLAMPMETER • 0.01mA resolution for measuring earth leakage currents • Amp ranges for standard current measurements • Analog bargraph display for trending • 40mm jaw opening  DCM330  Current measurements and the non-contact voltage sensor do not need the supplied test leads. The voltage detection function can identify the presence of live AC voltage from 50-1000 V at 50-500 Hz. SPECIFICATIONS Function AC Current AC Volts DC Volts Resistance: Range Accuracy 200.0 A ±3% ±3d, 50/60 Hz, Avg responding 200.0 / 1000 V ±1.5% ±5d, 50-500 Hz, Avg responding 200.0 / 1000 V ±1% ±2d 200.0Ω - 20.00MΩ ±1% ±2d (2k-2M ranges) (6 ranges) Continuity: <50Ω Buzzer sounds Overload Protection: 400 Arms on AC current, 600 Vrms on ohms 1 Display: 3 /2 digit, 2000 count Operating Temp.: 0ºC to 30ºC, <80% RH; 40ºC to 50ºC, <45% RH Battery: 2 AAA Alkaline Battery Life: 250hrs typical (auto power off after 10 minutes) Dimensions: 4.7" x 2.1" x 1.2" (193 x 54 x 21mm) Safety: IEC61010-1, CAT III 1000V, CATIV 600V DCM300E SPECIFICATIONS Ranges: Accuracy: 30/300mA: 0-200A: 200-250A: 250-300A: Circuit Voltage: Jaw Capability: Display: Data Hold: Operating Temp.: Storage Temp.: Battery: Dimensions: Safety: 30mA/300mA/30A/300A (50/60Hz) ±1.2% rdg ±5d ±1.2% rdg ±5d ±3.0% rdg ±5d ±5.0% rdg ±5d 600V AC max. 40mm (1.57") 31/2 digit, 3200 count Indicated by DH in display 0ºC to +40ºC, <80% RH -20ºC to +60ºC, <70% RH 2 LR44 button cells 2.5" x 7" x 0.9" (64 x 176 x 23mm) 300V phase to earth, 500V phase to phase CAT III or 600V CAT II ORDERING INFORMATION ME/DCM330 ME/DCM300E Fork Multimeter Leakage Clampmeter with carrying case 146