Preview only show first 10 pages with watermark. For full document please download

Aestiva™/5 Induction Anesthesia Machine

   EMBED


Share

Transcript

Aestiva™/5 Induction Aestiva™/5 Induction anesthesia machine Aestiva excellence for the induction room Aestiva/5 Induction, trolley base Aestiva/5 Induction, wall-rail mounted base Features Ease of use • • Individual, locking front casters (trolley base) Proven Aestiva pneumatic gas mixing and hypoxic guard • Provides flexibility for customization of the workstation • A wide variety of lower cabinet combinations of drawers and shelves (trolley base) Open architecture • • Supports physical integration of most Datex-Ohmeda monitoring solutions (trolley base) Integral dovetail rail that can be used to incorporate additional accessories (trolley base) Reduced life cycle costs • • Minimum O2 flow of 50 mL • Two scheduled planned maintenance checks per year • Smooth, faster acting fresh gas flow control Optional dual air flow tubes for resolution of low flows Wall-rail mounted base • Wall-rail mount attaches to standard wall rail Aestiva™/5 Induction Physical specifications Dimensions Lower drawers (optional on trolley base only)* Trolley base Wall-rail mounted base Height: 14.5 cm/5.7 in Height: 127 cm/50 in 65.3 cm/25.7 in Width: 38.5 cm/15.2 in Width: 63 cm/24.8 in 60 cm/23.7 in (with gas block); 51.2 cm/20.2 in (without gas block) Depth: 26 cm/10.2 in Depth: Weight: 83 cm/32.7 in Approximately 83.9 kg/185 lbs (without vaporizers) 24.6 cm/9.7 in (without folding work surface) Approximately 23.1 kg/50.8 lbs Lower shelves (optional on trolley base only)* Heights: 9.2 cm/3.6 in 20.6 cm/8.1 in 28.6 cm/11.3 in 13.2 cm/5.2 in 24.6 cm/9.7 in 36 cm/14.4 in Width: 42.5 cm/16.75 in 42.5 cm/16.75 in Depth: 36 cm/14.2 in 36 cm/14.2 in Casters (standard on trolley base only) Diameter: 12.5 cm/5 in Folding front work surface (optional on wall-rail mounted base only) Width: 31.5 cm/12.4 in Depth: 26.5 cm/10.4 in Weight limit: 11.5 kg/25 lbs Top shelf (optional on trolley base only) Weight limit: 23 kg/50 lbs Width: 47.5 cm/18.7 in Depth: 41 cm/16.1 in Folding side shelf (optional on trolley base only) Height: 82.6 cm/32.5 in Width: 26.5 cm/10.4 in Depth: 31.5 cm/12.4 in Weight limit: 23 kg/50 lbs DIN rail (optional on trolley base only) Side of tabletop: 30 cm/12 in Side of machine: 23.5 cm/9.25 in Top drawer — locking (internal dimensions) (One standard on trolley base) Height: 10.5 cm/4.1 in Width: 38.5 cm/15.2 in Depth: 26 cm/10.2 in * Lower cabinet can be configured with a variety of shelf and drawer combinations on the trolley base only. Space for additional shelves and drawers Aestiva™/5 Induction Anesthetic agent delivery Pneumatic specifications Delivery Common gas outlet Vaporizers: Tec 4 or greater Number of positions: 2 Connector: ISO 22 mm OD and 15 mm ID Gas supply W arn in g Se up Op e m rig Fa er an ht at ua Se ctor io l at re rv s na for al l co ice af l In tim m an fect st m d in ru es en m g ct ser da ai pe io vic tio nt rfo ns e dat ns en rm . e an ce an ce . Pipeline connections: Nex ma na tin e tio ec int Se era aff ma s rs d on Op cto an ati Fa ce nd e rvi me dat Se om ice rec t serv 5 4 3 2 1 .8 s. of ng rni all time ence ts.ion Wa ht atclave. presc ic agen unct uprigauto in the sthet conl ce. not use le anae initor. • Keep ns. • DoNot for mab be used uctio rman ce • flam to O monfor an ual al Instr perfo ting tenan • Only with manation affec mainions. See ors and ndat • Oper ice • Fact mme • Serv reco service date Lock ore bef use Ke ep ! Ne xt k Locbef ore use Pipeline input range: Ke ckfore Lobe use g es in n tim . ar at all W ht ons. ance rig cti rm up for tru rfo ce ep nual l Ins g pe an en Tool-free installation; Selectatec® manifold interlocks and isolates vaporizers ! Mounting: Next 18 5 16 4 Of 3 2 0% 1 14 12 10 8 7 6 5 4 3 2 1 .8 .6 .4 .2 s may flow thing of use gas low the brea the nds ng with in rni ngs with mme Wa setti ures reco and rizer mixt gly in. L/m 1013mb. vapo xiceda stron ng. re use. to 10 at High to hypo Ohm befo 0.2 to 30C lead it. monitori ual s of circu en manat flow of 18C oxyg r to res Refe for useeratu d brate temp Caliambient at y nl O ne ra lu of Is Tec s 6 Plu se U USE Y DES ONL TIONAL OPERA nly O e se an U flur En FLU RAN E Cylinder input options: T NO OUTPU LOW AGENT UP WARM LOW ALARMRY BATTE y onl e Use ran sflu De Tec 5 Tec 6 Plus 240 kPa to 600 kPa/35 psig to 88 psig DISS-male, DISS-female, DIN 13252, AS4059, S90-116 or NIST (ISO 5359) All fittings available for O2, N2O and Air and contain pipeline filter and check valve Trolley: Pin indexed in accordance with CGA-V-1 or DIN (nut and gland); contains input filter and check valve Note: Maximum of four cylinders: three inboard mounted, one outboard mounted Wall-rail mounted: Cylinders with regulators mount separately to wall-rail mount Primary regulator diaphragm minimum burst pressure: Primary regulator nominal output: Trolley: 2758 kPa/400 psig Trolley: ≤ 338 kPa/49 psig Pin indexed cylinder connections ≤ 407 kPa/59 psig DIN cylinder connections Gas power outlet (optional on trolley base only) Connector: DISS indexed in accordance with CGA-V-5 or Anatrir Gas: Oxygen Pressure and flow characteristics: Varies with source Wall-rail mount Aestiva™/5 Induction Pneumatic specifications, continued O2 controls Hypoxic guard system Method: Proportionate decrease of N2O, CO2, He/O2 with reduction in O2 pressure Supply failure alarm: O2 flush: Type: Mechanical Link-25™ Range: Provides a nominal minimum 25% concentration of oxygen in O2/N2O mixture Whistle sounds at or before 234 kPa/34 psi, for at least 7 seconds Materials Range: 35 to 50 L/min All materials in contact with patient breathing gases are free of natural latex rubber. Flowmeters Two tubes: 0.05 to 0.95 L/min and 1.0 to 15.0 L/min Minimum O2 flow: 50 mL/min ±25 mL N2O ranges: Two tubes: 0 to 0.95 L/min and 1.0 to 10.0 L/min Air range: One tube option: 1 to 15 L/min Two tube option: 0 to 0.95 and 1 to 15 L/min (low flow tube optional) Calibration: Calibration conditions:* Percent of full scale flow Accuracy (% of flowrate) 100 90 80 70 60 50 40 30 20 10 ±2.5% ±2.5% ±2.6% ±2.7% ±2.9% ±3.1% ±3.4% ±4.0% ±5.0% ±8.1% 20°C/68°F 101.3 kPa/760 mmHg * Different breathing circuit pressures, barometric pressures or temperatures change flowtube accuracy. Datex-Ohmeda Division • Instrumentarium Corp. P.O. Box 900, FIN-00031 Datex-Ohmeda, Finland Tel. +358 10 39411 • Fax +358 9 146 3310 www.datex-ohmeda.com Electrical specifications Inlet/outlet modules (optional on trolley base only) Outlets (optional): Dovetail rail mounted isolated auxiliary AC outlet, 220-240V CEE 7/7 IEC compliant Outlets not physically integrated into trolley base Environmental specifications System operation Temperature: 10° to 40°C/50° to 104°F Humidity: 15 to 95% relative humidity (non-condensing) per IEC 68-2-3 Altitude: –440 to 3565 m/500 to 800 mmHg System storage Temperature: –20° to 70°C/–4° to 158°F Humidity: 10 to 95% relative humidity (including condensing) per IEC 68-2-3 Altitude: –440 to 5860 m/375 to 800 mmHg AN3554-C/2 02 © 2001 Datex-Ohmeda Division Instrumentarium Corp. All rights reserved. Subject to change without notice. Datex®, Ohmeda® and other trademarks are property of Instrumentarium Corp. or its subsidiaries. All other product and company names are property of their respective owners. O2 ranges: