Transcript
Aestiva™/5 Induction
Aestiva™/5 Induction anesthesia machine Aestiva excellence for the induction room
Aestiva/5 Induction, trolley base
Aestiva/5 Induction, wall-rail mounted base
Features Ease of use
• •
Individual, locking front casters (trolley base) Proven Aestiva pneumatic gas mixing and hypoxic guard
•
Provides flexibility for customization of the workstation
•
A wide variety of lower cabinet combinations of drawers and shelves (trolley base)
Open architecture
• •
Supports physical integration of most Datex-Ohmeda monitoring solutions (trolley base) Integral dovetail rail that can be used to incorporate additional accessories (trolley base)
Reduced life cycle costs
• •
Minimum O2 flow of 50 mL
•
Two scheduled planned maintenance checks per year
•
Smooth, faster acting fresh gas flow control
Optional dual air flow tubes for resolution of low flows
Wall-rail mounted base
•
Wall-rail mount attaches to standard wall rail
Aestiva™/5 Induction Physical specifications Dimensions
Lower drawers (optional on trolley base only)*
Trolley base
Wall-rail mounted base
Height:
14.5 cm/5.7 in
Height:
127 cm/50 in
65.3 cm/25.7 in
Width:
38.5 cm/15.2 in
Width:
63 cm/24.8 in
60 cm/23.7 in (with gas block); 51.2 cm/20.2 in (without gas block)
Depth:
26 cm/10.2 in
Depth:
Weight:
83 cm/32.7 in
Approximately 83.9 kg/185 lbs (without vaporizers)
24.6 cm/9.7 in (without folding work surface) Approximately 23.1 kg/50.8 lbs
Lower shelves (optional on trolley base only)*
Heights:
9.2 cm/3.6 in 20.6 cm/8.1 in 28.6 cm/11.3 in
13.2 cm/5.2 in 24.6 cm/9.7 in 36 cm/14.4 in
Width:
42.5 cm/16.75 in
42.5 cm/16.75 in
Depth:
36 cm/14.2 in
36 cm/14.2 in
Casters (standard on trolley base only)
Diameter:
12.5 cm/5 in
Folding front work surface (optional on wall-rail mounted base only)
Width:
31.5 cm/12.4 in
Depth:
26.5 cm/10.4 in
Weight limit:
11.5 kg/25 lbs
Top shelf (optional on trolley base only)
Weight limit:
23 kg/50 lbs
Width:
47.5 cm/18.7 in
Depth:
41 cm/16.1 in
Folding side shelf (optional on trolley base only)
Height:
82.6 cm/32.5 in
Width:
26.5 cm/10.4 in
Depth:
31.5 cm/12.4 in
Weight limit:
23 kg/50 lbs
DIN rail (optional on trolley base only)
Side of tabletop:
30 cm/12 in
Side of machine:
23.5 cm/9.25 in
Top drawer — locking (internal dimensions) (One standard on trolley base)
Height:
10.5 cm/4.1 in
Width:
38.5 cm/15.2 in
Depth:
26 cm/10.2 in
* Lower cabinet can be configured with a variety of shelf and drawer combinations on the trolley base only.
Space for additional shelves and drawers
Aestiva™/5 Induction Anesthetic agent delivery
Pneumatic specifications
Delivery
Common gas outlet
Vaporizers:
Tec 4 or greater
Number of positions:
2
Connector:
ISO 22 mm OD and 15 mm ID
Gas supply
W arn in g
Se up Op e m rig Fa er an ht at ua Se ctor io l at re rv s na for al l co ice af l In tim m an fect st m d in ru es en m g ct ser da ai pe io vic tio nt rfo ns e dat ns en rm . e an ce an ce .
Pipeline connections:
Nex
ma na tin e tio ec int Se era aff ma s rs d on Op cto an ati Fa ce nd e rvi me dat Se om ice rec t serv
5
4
3
2
1 .8
s. of ng rni all time ence ts.ion Wa ht atclave. presc ic agen unct uprigauto in the sthet conl ce. not use le anae initor. • Keep ns. • DoNot for mab be used uctio rman ce • flam to O monfor an ual al Instr perfo ting tenan • Only with manation affec mainions. See ors and ndat • Oper ice • Fact mme • Serv reco service date
Lock ore bef use
Ke ep
!
Ne xt
k Locbef ore use
Pipeline input range:
Ke
ckfore Lobe use
g es in n tim . ar at all W ht ons. ance rig cti rm up for tru rfo ce ep nual l Ins g pe an en
Tool-free installation; Selectatec® manifold interlocks and isolates vaporizers
!
Mounting:
Next
18
5
16
4
Of
3
2
0%
1
14
12
10
8 7 6
5
4
3
2
1
.8 .6 .4 .2
s may flow thing of use gas low the brea the nds ng with in rni ngs with mme Wa setti ures reco and rizer mixt gly in. L/m 1013mb. vapo xiceda stron ng. re use. to 10 at High to hypo Ohm befo 0.2 to 30C lead it. monitori ual s of circu en manat flow of 18C oxyg r to res Refe for useeratu d brate temp Caliambient at
y nl O
ne ra lu of Is
Tec
s 6 Plu
se U
USE
Y DES ONL TIONAL OPERA
nly O e se an U flur En
FLU
RAN
E
Cylinder input options:
T NO
OUTPU
LOW
AGENT
UP WARM LOW ALARMRY BATTE
y onl e Use ran sflu De
Tec 5
Tec 6 Plus
240 kPa to 600 kPa/35 psig to 88 psig DISS-male, DISS-female, DIN 13252, AS4059, S90-116 or NIST (ISO 5359) All fittings available for O2, N2O and Air and contain pipeline filter and check valve Trolley: Pin indexed in accordance with CGA-V-1 or DIN (nut and gland); contains input filter and check valve Note:
Maximum of four cylinders: three inboard mounted, one outboard mounted
Wall-rail mounted: Cylinders with regulators mount separately to wall-rail mount Primary regulator diaphragm minimum burst pressure: Primary regulator nominal output:
Trolley: 2758 kPa/400 psig Trolley: ≤ 338 kPa/49 psig Pin indexed cylinder connections ≤ 407 kPa/59 psig DIN cylinder connections
Gas power outlet (optional on trolley base only)
Connector:
DISS indexed in accordance with CGA-V-5 or Anatrir
Gas:
Oxygen
Pressure and flow characteristics: Varies with source
Wall-rail mount
Aestiva™/5 Induction Pneumatic specifications, continued O2 controls
Hypoxic guard system
Method:
Proportionate decrease of N2O, CO2, He/O2 with reduction in O2 pressure
Supply failure alarm: O2 flush:
Type:
Mechanical Link-25™
Range:
Provides a nominal minimum 25% concentration of oxygen in O2/N2O mixture
Whistle sounds at or before 234 kPa/34 psi, for at least 7 seconds
Materials
Range: 35 to 50 L/min
All materials in contact with patient breathing gases are free of natural latex rubber.
Flowmeters
Two tubes: 0.05 to 0.95 L/min and 1.0 to 15.0 L/min Minimum O2 flow: 50 mL/min ±25 mL
N2O ranges:
Two tubes: 0 to 0.95 L/min and 1.0 to 10.0 L/min
Air range:
One tube option: 1 to 15 L/min Two tube option: 0 to 0.95 and 1 to 15 L/min (low flow tube optional)
Calibration:
Calibration conditions:*
Percent of full scale flow
Accuracy (% of flowrate)
100 90 80 70 60 50 40 30 20 10
±2.5% ±2.5% ±2.6% ±2.7% ±2.9% ±3.1% ±3.4% ±4.0% ±5.0% ±8.1%
20°C/68°F 101.3 kPa/760 mmHg
* Different breathing circuit pressures, barometric pressures or temperatures change flowtube accuracy.
Datex-Ohmeda Division • Instrumentarium Corp. P.O. Box 900, FIN-00031 Datex-Ohmeda, Finland Tel. +358 10 39411 • Fax +358 9 146 3310 www.datex-ohmeda.com
Electrical specifications Inlet/outlet modules (optional on trolley base only)
Outlets (optional): Dovetail rail mounted isolated auxiliary AC outlet, 220-240V CEE 7/7 IEC compliant Outlets not physically integrated into trolley base
Environmental specifications System operation
Temperature:
10° to 40°C/50° to 104°F
Humidity:
15 to 95% relative humidity (non-condensing) per IEC 68-2-3
Altitude:
–440 to 3565 m/500 to 800 mmHg
System storage
Temperature:
–20° to 70°C/–4° to 158°F
Humidity:
10 to 95% relative humidity (including condensing) per IEC 68-2-3
Altitude:
–440 to 5860 m/375 to 800 mmHg
AN3554-C/2 02 © 2001 Datex-Ohmeda Division Instrumentarium Corp. All rights reserved. Subject to change without notice. Datex®, Ohmeda® and other trademarks are property of Instrumentarium Corp. or its subsidiaries. All other product and company names are property of their respective owners.
O2 ranges: