AGA Series Control Stations (Multiple Column) IP65 Waterproof Multiple Column Aluminum Control Stations Versatile Combinations of Control Units The AGA multiple column control stations are designed for mounting various types of control units in various combinations. Standard control stations are available with predetermined specifications of cable lead-in holes and the control units to be mounted (contact configurations, voltage, button colors, and nameplates). • Versatile combinations of control units are possible. Select from a wide variety of 30 mm (1-13/64 inch) dia. control units. • The lid of the enclosure is hinged to make wiring and maintenance easy.
Specifications Type Degree of Protection (Note 1) Material (Enclosure) Coating Color (Melamine coating) Rated Insulation Voltage Insulation Resistance Dielectric Strength (Note 2) Standard Operating Conditions (Note 3) Enclosure Style Cable Lead-in (Wall Mount Type) Applicable Control Units
AGA480 • 580
AGA680 • 690
IP65 (IEC 60529, JEM1030)
• Control Unit Mounting Holes
Aluminum Yellow semi-gloss (Munsell 5Y7/1, outside only)
• Lead-in Fittings (Wall Mount Type)
600V (Buzzer: 250V) 5 MΩ minimum Between live and dead parts: 2500V AC, 1 minute Ambient temperature: -25 to +50ºC (no freezing) Relative humidity: 45 to 85% (no condensation) Wall mount/Stand Wall mount/Stand Types Types (4 × 2 or 5 × 2 holes) (6 × 2 or 6 × 3 holes) Entrance hub (Gland hub also available) HNA33 G1 (28 mm) IDEC ø30 mm series control units, AZ buzzer and AM ammeter (except enclosed type units)
Note 1: The degree of protection depends on the control units mounted on the enclosure. When IP65 control units are mounted, the entire control station has IP65 characteristics. (See page 1280) Note 2: AM ammeter/buzzer: 2000V AC, 1 minute Note 3: Buzzer: -10 to +40ºC
Rated Insulation Voltage Rated Thermal Current Contact Ratings by Utilization Category IEC60947-5-1
An entrance hub made of aluminum is supplied for connecting a steel conduit to lead in cables. AGA480 (4 × 2 holes), AGA580 (5 × 2 holes): With two HNA33 G1 for 28 mm conduit (Available with one HNA33, upon request) AGA680 (6 × 2 holes): With two HNA33 G1 for 28 mm conduit AGA690 (6 × 3 holes): With three HNA33 G1 for 28 mm conduit Gland hubs for lead in cables are also available.
• Stand Pole (Stand Type)
The pole is made of carbon steel (STK) pipe, and the base is made of iron. The coating color is the same as the enclosure, yellow (semi-gloss).
Lid
Hinge
Enclosure
Control Unit
Contact Ratings (Contact Block) Contact block
The holes for mounting control units are 30.5 mm in diameter with an anti-rotation notch. Mounting centers are 50 mm.
600V 10A AC-15 (A600) DC-13 (P600)
• Operational Voltage and Current by Utilization Category AC (50/60Hz) DC
Operational Current
Operational Voltage AC-12 Control of resistive loads and solid state loads AC-15 Control of electromagnetic loads (>72VA) DC-12 Control of resistive loads and solid state loads DC-13 Control of electromagnets
• Common
24V
48V
50V
110V 220V 440V
10A
−
10A
10A
6A
2A
10A
−
7A
5A
3A
1A
10A
5A
−
2.2A
1.1A
−
5A
2A
−
1.1A
0.6A
−
Minimum applicable load (reference) = 3V AC/DC, 5mA (the applicable range is subject to change according to the operating conditions)
Unit Mounting Hole Entrance Hub Waterproof Bushing Stainless Steel Screws
Pole Base
1298
AGA Series Control Stations (Multiple Column) Control Stations with Control Units Control stations are available with selected combination of control units as listed below. For the dimensions and mounting centers, see the figures on pages 1299 and 1300. • Control Units Mounted in Control Stations Type No.
Pushbutton PB
Pilot Light PL (Incandescent) Selector Switch SS
Meter
A
Style
Flush, 1NO-1NC
APN128 ∗
Dome, 220V AC (2W)
ASN311
Knob, 2-position, 1NO-1NC
AM ammeter (See page 1493)
Specify capacity (Type No.) Coating color of the meter bezel: N1.5
SS SS
Wall Mount AGAM5801Y
AA
(Note) AM ammeter
Without nameplate
APN128R ABN111 ABN111
Without nameplate ON OFF Without nameplate ON OFF Without nameplate ON OFF
PL PL
APN128R APN128G ABN111 ABN111
PL PL PB PB PB PB
PB PB PL PL
Stand AGA6801SY
PB PB PB PB
Wall Mount AGAM6801Y
AA
(Note) AM ammeter
Without nameplate
APN128R APN128G ABN111 ABN111
Without nameplate Without nameplate ON OFF
6 × 2 holes
PL PL
Stand AGAM6801SY
Without nameplate Without nameplate ON OFF
PB PB PB PB
PL PL PL
Wall Mount AGA6901Y
(Note) AM ammeter
AA PB PB
Stand AGAM4801SY
ABN111 ABN111
PB PB
ON OFF
Display Lights
Display Units
Safety Products
Terminal Blocks
Comm. Terminals
AS-Interface
Relays & Timers
Sockets
Circuit Protectors
PB PB PB PB PB PB
Wall Mount AGAM6901Y
AAA
(Note) AM ammeter
Without nameplate
Operator Interfaces
APN128R APN128G ABN111 ABN111
Without nameplate Without nameplate ON OFF
Sensors
PL PL PL
Note: Specify the Type No. of the meter to select a required capacity. • Control stations with a shade are available. See page 1300 for more details.
Control Units
Stand AGA6901SY
PB PB PB
Without nameplate
Flush Silhouette
APN128R ABN111 ABN111 APN128R ABN111 ABN111
PB PB PB PL PL PL
Wall Mount AGAM4801Y
Without nameplate Without nameplate ON OFF HAND-AUTO
APN128R ABN111 ABN111 APN128R ABN111 ABN111
PB PB
PL PL
Mounted Control Units NA Nameplate Type No. Legend
Symbol
PB PB
PL PL
6 × 3 holes
4 × 2 holes
PB PB
PB PB
Package Quantity: 1
Mounted Control Units NA Nameplate Type No. Legend
Stand AGA5801SY
Wall Mount AGA6801Y
• AGA480 Control Box (Wall mount/Stand Type)
Package Quantity: 1
APN128R APN128G ABN111 ABN111 ASN311
PL PL
Stand AGAM5801SY
Type List
Stand AGA4801SY
PL PL
PL PL
Note: Specify a button or lens color code in place of ∗: Pushbutton: B (black), G (green), R (red) Pilot Light: G (green), R (red), W (white) Flush pushbuttons are supplied with black, green, and red color caps.
Wall Mount AGA4801Y
Symbol
PB PB
ABN111 ∗
Control Box Type No. Style (Ordering Type No.)
Control Box Type No. (Ordering Type No.) Wall Mount AGA5801Y
Specifications
5 × 2 holes
Control Unit
• AGA580/AGA690 Control Box (Wall mount/Stand Type)
PL PL PL
Stand AGAM6901SY
PB PB PB PB PB PB
Without nameplate ON OFF Without nameplate ON OFF
Power Supplies
PLCs & SmartRelay
Control Stations
Empty Enclosures Style Type No. (Ordering Type No.)
Package Quantity: 1
4 holes AGA481Y
5 holes
AGA482Y
AGA580Y
AGA581Y
6 holes AGA582Y
AGA681Y
AGA682Y
AGA690Y
AGA691Y References
70
85
80
85
100
140
Weight (Approx.) • Control Unit Mounting Holes
.5
80
80
80
2.6 kg • Effective Depth inside the Enclosure (4 or 5 x 2 holes)
100
160
100
6.8 kg
114
95
124
Front
120
4.5
Front
160
(6 x 2 or 3 holes)
86 92.5 31.7
50
50
50 80
80
75
75 50
75 50
Appearance
50
50
70
ø30
Explosion Protection
(Meter Mounting Hole)
All dimension in mm
Note: Entrance hubs HNA33YG G1 for 28mm conduit are supplied as standard. The quantity is as shown in the figure above. • In addition to the enclosures shown above, enclosures with a shade and stand type enclosures are also available. See page 1300 for more details.
1299
AGA Series Control Stations (Multiple Column) • Other Types
Type No. (Ordering Type No.)
Control Units X X
Hubs X X
Shade X X X X
4 or 5 × 2 holes
Stand X X X
AGA4801KY AGA4801KSY AGA481KY AGA481SY AGA481KSY 70
AGAM4801KY AGAM4801KSY AGA482KY AGA482SY AGA482KSY
− − AGA580KY AGA580SY AGA580KSY
85
AGA5801KY AGA5801KSY AGA581KY AGA581SY AGA581KSY
AGAM5801KY AGAM5801KSY AGA582KY AGA582SY AGA582KSY 85
70
75
75
Style
Package Quantity: 1
50
50
50
50
Appearance
80
Weight (Approx.)
Style
Type No. (Ordering Type No.)
With control units and a shade With control units, stand type with a shade With a shade Stand type Stand type with a shade
Control Units X X
Hubs X X
Shade X X X X
80
5.0 kg 10.6 kg 3.1 kg 8.0 kg 8.4 kg
80
− − 3.1 kg 8.0 kg 8.4 kg
6.7 kg 12.3 kg 3.1 kg 8.0 kg 8.4 kg
X X
5.3 kg 10.6 kg 3.1 kg 8.0 kg 8.4 kg
7.0 kg 12.3 kg 3.1 kg 8.0 kg 8.4 kg
AGA6901KY AGA6901KSY AGA691KY AGA691SY AGA691KSY
AGAM6901KY AGAM6901KSY − − −
6 × 2 or 3 holes
Stand X
80
80
AGA6801KY AGA6801KSY AGA681KY AGA681SY AGA681KSY 80
AGAM6801KY AGAM6801KSY AGA682KY AGA682SY AGA682KSY
− − AGA690KY AGA690SY AGA690KSY
160
140
75
75
50
50
100
50
50
Appearance
100
Weight (Approx.)
With control units and a shade With control units,stand type with a shade With a shade Stand type Stand type with a shade
11.3 kg 17.5 kg 7.6 kg 13.0 kg 13.7 kg
• For more details about enclosures without control units, see page 1299. • For more detail about control units mounted on control stations, see page 1299.
1300
100
13.0 kg 19.2 kg 7.6 kg 13.0 kg 13.7 kg
160
− − 7.6 kg 13.0 kg 13.7 kg
160
11.3 kg 17.5 kg 7.6 kg 13.0 kg 13.7 kg
13.8 kg 20.0 kg − − −
AGA Series Control Stations (Multiple Column) Dimensions
7
Hinged side
Type No. HNG31 HNAG32 HNAG33
Grounding terminal M4
Applicable Cable Diameter (R) 8, 10, 12 13, 15, 17 18, 20, 22
Grounding terminal M4
Hub
(35)
40 80
80
Hub
(35)
80
HNA33 G1 for 28 mm conduit 2 column type: 2 entrance hubs attached 3 column type: 3 entrance hubs attached Gland hubs for leading in cables are also available.
Shade
300 380
(1.2)
Hinged side
280 (Centers) 320
(74)
100
35 max. Shade
4-ø8 Mounting holes (192) 35 max. 132
(380) 321 295 280
4-ø4.4 Mounting holes (152)
210 180 (Centers)
(87)
(290)
Flush Silhouette
• Entrance Hub (supplied)
• AGA680/AGA690 (Wall Mount Type)
(1.2)
• AGA480/AGA580 (Wall Mount Type)
• AGA480/AGA580 (Stand Type)
AS-Interface
(1.2)
(190) Shade
130 Relays & Timers
100 (87)
(1.2)
(150)
380
Hinged side
Sockets
320
Hinged side
(74)
210
Safety Products
Comm. Terminals
• AGA680/AGA690 (Stand Type) 280
Shade
Display Units
52
(380) (290)
Display Lights
Terminal Blocks
Weight: Approx. 10.5 kg
Weight: Approx. 4.8 kg
Control Units
Circuit Protectors
(1520)
(1580)
Power Supplies
M6 Grounding terminal
PLCs & SmartRelay
M6 Grounding terminal
Operator Interfaces
ø230 ø200
10
Weight: Approx. 10.2 kg
100
100
10
Sensors
Control Stations
ø230 ø200
Weight: Approx. 17 kg Explosion Protection
4-ø14 Mounting holes
4-ø14 Mounting holes References
Application Examples of Control Stations • AGA580 Control Station ø30 Control unit
Hinge
• AGA690 Control Station Internal plate
Hinge
Relay
Timer
Terminal block
ø30 Control unit Terminal block
1301
AGA Series Control Stations (Multiple Column) Accessory (Options) Name & Shape Enclosure Shade
Package Quantity: 1 Type No. (Ordering Type No.)
290
152
74
Description & Dimensions • Used on AGA480/AGA580 enclosures as a protection for the control units against direct sunlight and falling objects. • Color: 5Y7/1 (semi-gloss) • Shade mounting hole 66
AGZ-S2Y For AGA480/AGA580 Material: SPCC Thickness: 1 mm Weight: Approx. 0.46 kg
• Used on AGA680/AGA690 control boxes as a protection for the control units against direct sunlight and falling objects. • Color: 5Y7/1 (semi-gloss) • Shade mounting hole
Enclosure Shade 380
192
2-M4 Tapped hole: Depth 5 Pilot hole: Depth 5.5 max. (no penetration)
180
87
81
AGZ-S3Y For AGA680/AGA690 Material: SPCC Thickness: 1 mm Weight: Approx. 0.72 kg
2-M4 Tapped hole: Depth 5 Pilot hole: Depth 5.5 max. (no penetration)
250
250 (300)
Internal Plate AGZ-P2 (For AGA480/AGA580) • Used to mount terminal blocks, relays, timers, and other units for internal wiring.
130 (195) Dimensions in ( ) for AGA690 control box
Material: SPCC (Zinc-plated) Thickness: 2.3 mm Weight: AGZ-P2: Approx. 0.59 kg AGZ-P3: Approx. 1.05 kg
AGZ-P3 (For AGA680/AGA690)
• For maintenance of the stand part. • Color: 5Y7/1 (semi-gloss)
Stand Pole
4-
ø6
.5
Ho
72 50 le
51 65
AGZ-S205
(8 to 9) 94
2
1°
2 ø5 Stand gasket
AGZ-S205 (For AGA480/AGA580)
Grounding terminal (M6 8)
10
4-ø14 Hole
100
(1005) (1199)
Sealing base Pole Outside Dia.: ø48.6 Inside Dia.: ø44.0 Base
Weight: Approx. 5.6 kg
ø230
ø200
Stand Pole
AGZ-S206 ø6
.5
Ho
82 66
le
66 82
4-
2 (7 to 8)
Pole Outside Dia.: ø60.5 Inside Dia.: ø55.9 Grounding terminal (M6 8)
10
ø230
ø200
Weight: Approx. 6.5 kg
1302
100
Base 4-ø14 Hole
(1200)
Sealing base (1004)
AGZ-S206 (For AGA680/AGA690)
1º
5
96
ø6
Stand gasket
AGA Series Control Stations (Multiple Column) Instructions
Ordering Information
• Precautions for Mounting AGA480/AGA580 Control Stations on Panel 1. Insert M4 screws into the waterproof bushings at all four corners inside the box. Push the screws with a screwdriver and penetrate the bushings (Figure 1). 2. Thrust the screws into panel holes and secure the screws with nuts (Figure 2). Waterproof characteristics are not affected by piecing the bushings with screws.
• When ordering control stations with control units (standard): Specify the Ordering Type No. of the control station.
Box Waterproof Bushing
Figure 1
• When ordering enclosures without control units: Specify the following items. 1. Ordering Type No. of the enclosure 2. Ordering Type No. and specifications of the control units to be mounted (lens color, button color, etc.) 3. Nameplate 4. Lead-in fitting Only when ordering the gland hub for leading in cables, specify the Ordering Type No. and the cable outside diameter. (R). 5. Other specifications
13
Control Unit and Nameplate
Panel surface
Figure 2
Lead-in Fitting
Control Units
Display Lights
Display Units
Safety Products
Terminal Blocks
Comm. Terminals
Ordering Example Type No. of Enclosure
Flush Silhouette
AGA581Y APN128R APN128G ABN210B, with NA-1 ABN201R, with NA-2 ASN311, with NA-32 HNAG33 R18
Note: Any ø30 mm series control units are selectable. Take into consideration the degree of protection of the control unit and the effective depth of the enclosure.
AS-Interface
Relays & Timers
Sockets
Circuit Protectors
Power Supplies
PLCs & SmartRelay
Operator Interfaces
Sensors
Control Stations
Explosion Protection
References
1303