Preview only show first 10 pages with watermark. For full document please download

Aga Series Control Stations (multiple Column)

   EMBED


Share

Transcript

AGA Series Control Stations (Multiple Column) IP65 Waterproof Multiple Column Aluminum Control Stations Versatile Combinations of Control Units The AGA multiple column control stations are designed for mounting various types of control units in various combinations. Standard control stations are available with predetermined specifications of cable lead-in holes and the control units to be mounted (contact configurations, voltage, button colors, and nameplates). • Versatile combinations of control units are possible. Select from a wide variety of 30 mm (1-13/64 inch) dia. control units. • The lid of the enclosure is hinged to make wiring and maintenance easy. Specifications Type Degree of Protection (Note 1) Material (Enclosure) Coating Color (Melamine coating) Rated Insulation Voltage Insulation Resistance Dielectric Strength (Note 2) Standard Operating Conditions (Note 3) Enclosure Style Cable Lead-in (Wall Mount Type) Applicable Control Units AGA480 • 580 AGA680 • 690 IP65 (IEC 60529, JEM1030) • Control Unit Mounting Holes Aluminum Yellow semi-gloss (Munsell 5Y7/1, outside only) • Lead-in Fittings (Wall Mount Type) 600V (Buzzer: 250V) 5 MΩ minimum Between live and dead parts: 2500V AC, 1 minute Ambient temperature: -25 to +50ºC (no freezing) Relative humidity: 45 to 85% (no condensation) Wall mount/Stand Wall mount/Stand Types Types (4 × 2 or 5 × 2 holes) (6 × 2 or 6 × 3 holes) Entrance hub (Gland hub also available) HNA33 G1 (28 mm) IDEC ø30 mm series control units, AZ buzzer and AM ammeter (except enclosed type units) Note 1: The degree of protection depends on the control units mounted on the enclosure. When IP65 control units are mounted, the entire control station has IP65 characteristics. (See page 1280) Note 2: AM ammeter/buzzer: 2000V AC, 1 minute Note 3: Buzzer: -10 to +40ºC Rated Insulation Voltage Rated Thermal Current Contact Ratings by Utilization Category IEC60947-5-1 An entrance hub made of aluminum is supplied for connecting a steel conduit to lead in cables. AGA480 (4 × 2 holes), AGA580 (5 × 2 holes): With two HNA33 G1 for 28 mm conduit (Available with one HNA33, upon request) AGA680 (6 × 2 holes): With two HNA33 G1 for 28 mm conduit AGA690 (6 × 3 holes): With three HNA33 G1 for 28 mm conduit Gland hubs for lead in cables are also available. • Stand Pole (Stand Type) The pole is made of carbon steel (STK) pipe, and the base is made of iron. The coating color is the same as the enclosure, yellow (semi-gloss). Lid Hinge Enclosure Control Unit Contact Ratings (Contact Block) Contact block The holes for mounting control units are 30.5 mm in diameter with an anti-rotation notch. Mounting centers are 50 mm. 600V 10A AC-15 (A600) DC-13 (P600) • Operational Voltage and Current by Utilization Category AC (50/60Hz) DC Operational Current Operational Voltage AC-12 Control of resistive loads and solid state loads AC-15 Control of electromagnetic loads (>72VA) DC-12 Control of resistive loads and solid state loads DC-13 Control of electromagnets • Common 24V 48V 50V 110V 220V 440V 10A − 10A 10A 6A 2A 10A − 7A 5A 3A 1A 10A 5A − 2.2A 1.1A − 5A 2A − 1.1A 0.6A − Minimum applicable load (reference) = 3V AC/DC, 5mA (the applicable range is subject to change according to the operating conditions) Unit Mounting Hole Entrance Hub Waterproof Bushing Stainless Steel Screws Pole Base 1298 AGA Series Control Stations (Multiple Column) Control Stations with Control Units Control stations are available with selected combination of control units as listed below. For the dimensions and mounting centers, see the figures on pages 1299 and 1300. • Control Units Mounted in Control Stations Type No. Pushbutton PB Pilot Light PL (Incandescent) Selector Switch SS Meter A Style Flush, 1NO-1NC APN128 ∗ Dome, 220V AC (2W) ASN311 Knob, 2-position, 1NO-1NC AM ammeter (See page 1493) Specify capacity (Type No.) Coating color of the meter bezel: N1.5 SS SS Wall Mount AGAM5801Y AA (Note) AM ammeter Without nameplate APN128R ABN111 ABN111 Without nameplate ON OFF Without nameplate ON OFF Without nameplate ON OFF PL PL APN128R APN128G ABN111 ABN111 PL PL PB PB PB PB PB PB PL PL Stand AGA6801SY PB PB PB PB Wall Mount AGAM6801Y AA (Note) AM ammeter Without nameplate APN128R APN128G ABN111 ABN111 Without nameplate Without nameplate ON OFF 6 × 2 holes PL PL Stand AGAM6801SY Without nameplate Without nameplate ON OFF PB PB PB PB PL PL PL Wall Mount AGA6901Y (Note) AM ammeter AA PB PB Stand AGAM4801SY ABN111 ABN111 PB PB ON OFF Display Lights Display Units Safety Products Terminal Blocks Comm. Terminals AS-Interface Relays & Timers Sockets Circuit Protectors PB PB PB PB PB PB Wall Mount AGAM6901Y AAA (Note) AM ammeter Without nameplate Operator Interfaces APN128R APN128G ABN111 ABN111 Without nameplate Without nameplate ON OFF Sensors PL PL PL Note: Specify the Type No. of the meter to select a required capacity. • Control stations with a shade are available. See page 1300 for more details. Control Units Stand AGA6901SY PB PB PB Without nameplate Flush Silhouette APN128R ABN111 ABN111 APN128R ABN111 ABN111 PB PB PB PL PL PL Wall Mount AGAM4801Y Without nameplate Without nameplate ON OFF HAND-AUTO APN128R ABN111 ABN111 APN128R ABN111 ABN111 PB PB PL PL Mounted Control Units NA Nameplate Type No. Legend Symbol PB PB PL PL 6 × 3 holes 4 × 2 holes PB PB PB PB Package Quantity: 1 Mounted Control Units NA Nameplate Type No. Legend Stand AGA5801SY Wall Mount AGA6801Y • AGA480 Control Box (Wall mount/Stand Type) Package Quantity: 1 APN128R APN128G ABN111 ABN111 ASN311 PL PL Stand AGAM5801SY Type List Stand AGA4801SY PL PL PL PL Note: Specify a button or lens color code in place of ∗: Pushbutton: B (black), G (green), R (red) Pilot Light: G (green), R (red), W (white) Flush pushbuttons are supplied with black, green, and red color caps. Wall Mount AGA4801Y Symbol PB PB ABN111 ∗ Control Box Type No. Style (Ordering Type No.) Control Box Type No. (Ordering Type No.) Wall Mount AGA5801Y Specifications 5 × 2 holes Control Unit • AGA580/AGA690 Control Box (Wall mount/Stand Type) PL PL PL Stand AGAM6901SY PB PB PB PB PB PB Without nameplate ON OFF Without nameplate ON OFF Power Supplies PLCs & SmartRelay Control Stations Empty Enclosures Style Type No. (Ordering Type No.) Package Quantity: 1 4 holes AGA481Y 5 holes AGA482Y AGA580Y AGA581Y 6 holes AGA582Y AGA681Y AGA682Y AGA690Y AGA691Y References 70 85 80 85 100 140 Weight (Approx.) • Control Unit Mounting Holes .5 80 80 80 2.6 kg • Effective Depth inside the Enclosure (4 or 5 x 2 holes) 100 160 100 6.8 kg 114 95 124 Front 120 4.5 Front 160 (6 x 2 or 3 holes) 86 92.5 31.7 50 50 50 80 80 75 75 50 75 50 Appearance 50 50 70 ø30 Explosion Protection (Meter Mounting Hole) All dimension in mm Note: Entrance hubs HNA33YG G1 for 28mm conduit are supplied as standard. The quantity is as shown in the figure above. • In addition to the enclosures shown above, enclosures with a shade and stand type enclosures are also available. See page 1300 for more details. 1299 AGA Series Control Stations (Multiple Column) • Other Types Type No. (Ordering Type No.) Control Units X X Hubs X X Shade X X X X 4 or 5 × 2 holes Stand X X X AGA4801KY AGA4801KSY AGA481KY AGA481SY AGA481KSY 70 AGAM4801KY AGAM4801KSY AGA482KY AGA482SY AGA482KSY − − AGA580KY AGA580SY AGA580KSY 85 AGA5801KY AGA5801KSY AGA581KY AGA581SY AGA581KSY AGAM5801KY AGAM5801KSY AGA582KY AGA582SY AGA582KSY 85 70 75 75 Style Package Quantity: 1 50 50 50 50 Appearance 80 Weight (Approx.) Style Type No. (Ordering Type No.) With control units and a shade With control units, stand type with a shade With a shade Stand type Stand type with a shade Control Units X X Hubs X X Shade X X X X 80 5.0 kg 10.6 kg 3.1 kg 8.0 kg 8.4 kg 80 − − 3.1 kg 8.0 kg 8.4 kg 6.7 kg 12.3 kg 3.1 kg 8.0 kg 8.4 kg X X 5.3 kg 10.6 kg 3.1 kg 8.0 kg 8.4 kg 7.0 kg 12.3 kg 3.1 kg 8.0 kg 8.4 kg AGA6901KY AGA6901KSY AGA691KY AGA691SY AGA691KSY AGAM6901KY AGAM6901KSY − − − 6 × 2 or 3 holes Stand X 80 80 AGA6801KY AGA6801KSY AGA681KY AGA681SY AGA681KSY 80 AGAM6801KY AGAM6801KSY AGA682KY AGA682SY AGA682KSY − − AGA690KY AGA690SY AGA690KSY 160 140 75 75 50 50 100 50 50 Appearance 100 Weight (Approx.) With control units and a shade With control units,stand type with a shade With a shade Stand type Stand type with a shade 11.3 kg 17.5 kg 7.6 kg 13.0 kg 13.7 kg • For more details about enclosures without control units, see page 1299. • For more detail about control units mounted on control stations, see page 1299. 1300 100 13.0 kg 19.2 kg 7.6 kg 13.0 kg 13.7 kg 160 − − 7.6 kg 13.0 kg 13.7 kg 160 11.3 kg 17.5 kg 7.6 kg 13.0 kg 13.7 kg 13.8 kg 20.0 kg − − − AGA Series Control Stations (Multiple Column) Dimensions 7 Hinged side Type No. HNG31 HNAG32 HNAG33 Grounding terminal M4 Applicable Cable Diameter (R) 8, 10, 12 13, 15, 17 18, 20, 22 Grounding terminal M4 Hub (35) 40 80 80 Hub (35) 80 HNA33 G1 for 28 mm conduit 2 column type: 2 entrance hubs attached 3 column type: 3 entrance hubs attached Gland hubs for leading in cables are also available. Shade 300 380 (1.2) Hinged side 280 (Centers) 320 (74) 100 35 max. Shade 4-ø8 Mounting holes (192) 35 max. 132 (380) 321 295 280 4-ø4.4 Mounting holes (152) 210 180 (Centers) (87) (290) Flush Silhouette • Entrance Hub (supplied) • AGA680/AGA690 (Wall Mount Type) (1.2) • AGA480/AGA580 (Wall Mount Type) • AGA480/AGA580 (Stand Type) AS-Interface (1.2) (190) Shade 130 Relays & Timers 100 (87) (1.2) (150) 380 Hinged side Sockets 320 Hinged side (74) 210 Safety Products Comm. Terminals • AGA680/AGA690 (Stand Type) 280 Shade Display Units 52 (380) (290) Display Lights Terminal Blocks Weight: Approx. 10.5 kg Weight: Approx. 4.8 kg Control Units Circuit Protectors (1520) (1580) Power Supplies M6 Grounding terminal PLCs & SmartRelay M6 Grounding terminal Operator Interfaces ø230 ø200 10 Weight: Approx. 10.2 kg 100 100 10 Sensors Control Stations ø230 ø200 Weight: Approx. 17 kg Explosion Protection 4-ø14 Mounting holes 4-ø14 Mounting holes References Application Examples of Control Stations • AGA580 Control Station ø30 Control unit Hinge • AGA690 Control Station Internal plate Hinge Relay Timer Terminal block ø30 Control unit Terminal block 1301 AGA Series Control Stations (Multiple Column) Accessory (Options) Name & Shape Enclosure Shade Package Quantity: 1 Type No. (Ordering Type No.) 290 152 74 Description & Dimensions • Used on AGA480/AGA580 enclosures as a protection for the control units against direct sunlight and falling objects. • Color: 5Y7/1 (semi-gloss) • Shade mounting hole 66 AGZ-S2Y For AGA480/AGA580 Material: SPCC Thickness: 1 mm Weight: Approx. 0.46 kg • Used on AGA680/AGA690 control boxes as a protection for the control units against direct sunlight and falling objects. • Color: 5Y7/1 (semi-gloss) • Shade mounting hole Enclosure Shade 380 192 2-M4 Tapped hole: Depth 5 Pilot hole: Depth 5.5 max. (no penetration) 180 87 81 AGZ-S3Y For AGA680/AGA690 Material: SPCC Thickness: 1 mm Weight: Approx. 0.72 kg 2-M4 Tapped hole: Depth 5 Pilot hole: Depth 5.5 max. (no penetration) 250 250 (300) Internal Plate AGZ-P2 (For AGA480/AGA580) • Used to mount terminal blocks, relays, timers, and other units for internal wiring. 130 (195) Dimensions in ( ) for AGA690 control box Material: SPCC (Zinc-plated) Thickness: 2.3 mm Weight: AGZ-P2: Approx. 0.59 kg AGZ-P3: Approx. 1.05 kg AGZ-P3 (For AGA680/AGA690) • For maintenance of the stand part. • Color: 5Y7/1 (semi-gloss) Stand Pole 4- ø6 .5 Ho 72 50 le 51 65 AGZ-S205 (8 to 9) 94 2 1° 2 ø5 Stand gasket AGZ-S205 (For AGA480/AGA580) Grounding terminal (M6 8) 10 4-ø14 Hole 100 (1005) (1199) Sealing base Pole Outside Dia.: ø48.6 Inside Dia.: ø44.0 Base Weight: Approx. 5.6 kg ø230 ø200 Stand Pole AGZ-S206 ø6 .5 Ho 82 66 le 66 82 4- 2 (7 to 8) Pole Outside Dia.: ø60.5 Inside Dia.: ø55.9 Grounding terminal (M6 8) 10 ø230 ø200 Weight: Approx. 6.5 kg 1302 100 Base 4-ø14 Hole (1200) Sealing base (1004) AGZ-S206 (For AGA680/AGA690) 1º 5 96 ø6 Stand gasket AGA Series Control Stations (Multiple Column) Instructions Ordering Information • Precautions for Mounting AGA480/AGA580 Control Stations on Panel 1. Insert M4 screws into the waterproof bushings at all four corners inside the box. Push the screws with a screwdriver and penetrate the bushings (Figure 1). 2. Thrust the screws into panel holes and secure the screws with nuts (Figure 2). Waterproof characteristics are not affected by piecing the bushings with screws. • When ordering control stations with control units (standard): Specify the Ordering Type No. of the control station. Box Waterproof Bushing Figure 1 • When ordering enclosures without control units: Specify the following items. 1. Ordering Type No. of the enclosure 2. Ordering Type No. and specifications of the control units to be mounted (lens color, button color, etc.) 3. Nameplate 4. Lead-in fitting  Only when ordering the gland hub for leading in cables, specify the Ordering Type No. and the cable outside diameter. (R). 5. Other specifications 13 Control Unit and Nameplate Panel surface Figure 2 Lead-in Fitting Control Units Display Lights Display Units Safety Products Terminal Blocks Comm. Terminals Ordering Example Type No. of Enclosure Flush Silhouette AGA581Y APN128R APN128G ABN210B, with NA-1 ABN201R, with NA-2 ASN311, with NA-32 HNAG33 R18 Note: Any ø30 mm series control units are selectable. Take into consideration the degree of protection of the control unit and the effective depth of the enclosure. AS-Interface Relays & Timers Sockets Circuit Protectors Power Supplies PLCs & SmartRelay Operator Interfaces Sensors Control Stations Explosion Protection References 1303