Preview only show first 10 pages with watermark. For full document please download

Agere At Command Reference Guide

   EMBED


Share

Transcript

Manual, Rev. 1 August 2002 Controller-Based Modem AT Command Reference Manual Introduction The following reference manual specifies the Agere Systems Inc. AT command set for controller-based modem products. Controller-based products incorporate all of the functionality needed to create a fully functional modem product in a single chip set. They do not rely on the host system for modem protocol processing. Generally, controllerbased solutions include a partial ISA interface to communicate with the host system. However the very nature of controller-based configurations makes this type of product interface independent and can use almost any interface format to receive and transmit modem data to the host system. Agere Systems controller-based modems support a broad base of commands for data, FAX, and voice communications. The command set includes support for the basic data commands standardized by ITU-T recommendation V.250 (05/99)*, class 1 FAX commands standardized by ITU-T recommendation T.31 (08/95)†, class 2 FAX commands standardized by ITU-T recommendation T.32 (08/95)‡, and voice commands standardized by ITU-T recommendation V.253 (02/98). Additional support is included for many nonstandard commands. Most of the nonstandardized commands are designed to support modem product development and solution debugging efforts. This document contains an overview of the supported commands, responses, and registers used by Agere Systems’ controller-based modem products. However, a particular modem may not support the entire AT command set. Some features are dependent on product application, licensing, and other contractual agreements. * This document contains additional commands which support V.92 and V.44. † Controller-based modem products support amendment 1 to T.31 which defines command modifications for V.34 FAX. ‡ Controller-based modem products support amendment 1 to T.32 which defines command modifications for V.34 FAX. Controller-Based Modem AT Command Reference Manual Manual, Rev. 1 August 2002 Table of Contents Contents Page Introduction .............................................................................................................................................................. 1 How to Use This Manual ......................................................................................................................................... 6 AT Command Conventions ................................................................................................................................... 6 Sample Command ............................................................................................................................................. 6 Basic Syntax Commands ................................................................................................................................... 7 Extended Syntax Commands ............................................................................................................................. 7 S Register Conventions ........................................................................................................................................ 7 S register sample ............................................................................................................................................... 8 Other Document Conventions ............................................................................................................................... 8 Synchronous Mode and V.80 AT Commands .......................................................................................................... 8 AT Command Set .................................................................................................................................................... 9 Data and General Commands .............................................................................................................................. 9 +++ Escape Sequence ....................................................................................................................................... 9 A/—Repeat Last Command ............................................................................................................................... 9 A—Answer ......................................................................................................................................................... 9 B—Communication Standard Setting .................................................................................................. 10 C—Carrier Control ............................................................................................................................... 10 D—Dial ........................................................................................................................................ 10 E—Echo Command ............................................................................................................................. 12 F—On-Line Data Character Echo Command ...................................................................................... 12 H—Hook Control ................................................................................................................................. 12 I—Request ID Information ................................................................................................................... 13 L—Speaker Volume ............................................................................................................................. 16 M—Speaker Control ............................................................................................................................ 16 N—Modulation Handshake .................................................................................................................. 16 O—Return to On-Line Data Mode ....................................................................................................... 17 P—Select Pulse Dialing ................................................................................................................................... 17 Q—Result Code Control ...................................................................................................................... 17 T—Select Tone Dialing ..................................................................................................................................... 18 V—DCE Response Format ................................................................................................................. 18 W—Result Code Option ...................................................................................................................... 19 X—Select Result Code and Monitor Call Progress ............................................................................. 19 Y—Long-Space Disconnect ................................................................................................................ 21 Z—Reset and Recall Stored Profile ..................................................................................................... 21 &B—V.32 Auto Retrain ........................................................................................................................ 21 &C—Data Carrier Detect (DCD) Control ............................................................................................. 22 &D—Data Terminal Ready (DTR) Control ........................................................................................... 22 &F—Restore Factory Default Configuration ........................................................................................ 22 &G—V.22 bis Guard Tone Control ....................................................................................................... 23 &J—Auxiliary Relay Option .................................................................................................................. 23 &K—Local Flow Control Selection ....................................................................................................... 24 &M—Asynchronous Communications Mode ....................................................................................... 24 &P—Pulse Dial Make-to-Break Ratio Selection .................................................................................. 24 &Q—Asynchronous Communications Mode ....................................................................................... 25 &S—Data Set Ready (DSR) Option .................................................................................................... 25 &T—Self-Test Commands ................................................................................................................... 26 &V—View Active Configuration ........................................................................................................... 26 &W—Store Current Configuration ....................................................................................................... 28 &Y—Select Stored Profile for Hard Reset ........................................................................................... 28 &Z=—Store Telephone Number .......................................................................... 28 \A—Select Maximum MNP Block Size ................................................................................................ 28 \B—Send Break ......................................................................................................................... 29 2 Agere Systems Inc. Controller-Based Modem AT Command Reference Manual Manual, Rev. 1 August 2002 Table of Contents Contents Page \G—Modem Port Flow Control ............................................................................................................ 29 \J—Adjust Bits/s Rate Control ............................................................................................................. 29 \K—Set Break Control ......................................................................................................................... 30 \N—Select Error Control Mode ........................................................................................................... 31 \Q—Local Flow Control Selection ....................................................................................................... 31 \R—Ring Indicator Signal Off After Answer ......................................................................................... 32 \T—Inactivity Timer ............................................................................................................................. 32 \V—Protocol Result Code ................................................................................................................... 32 \X—XON/XOFF Pass Through ............................................................................................................ 33 -C—Enable Direct Connect ................................................................................................................. 33 -V90=—V.90 Downstream Rate Control ................................................................................................ 33 %B—View Numbers in Blacklist ....................................................................................................................... 34 %C—Data Compression Control ........................................................................................................ 35 %E—Auto Fallback/Fallforward Control ............................................................................................... 35 +A8E=,,,—V.8 and V.8 bis Operation Controls ........................................................ 35 +A8T=,<1st message>,<2nd message>,,,— Send V.8 bis Signal and/or Message ............................................................................................................ 36 +DCS=,—Select Data Compression Algorithm ....................................................................... 38 +DR—Data Compression Reporting ................................................................................................... 38 +DS=,,,—V.42 bis Data Compression ....... 39 +DS44=,,,, , ,,,—V.44 Data Compression ......... 40 +EB=,,—Break Handling In Error Control Operation .................. 41 +EFCS=—32-bit Frame Check Sequence .......................................................................................... 42 +ER=—Error Control Reporting .......................................................................................................... 42 +ES=,,—Error Control Selection .................................................................. 43 +ESA=,,,,,,—Set Up Error Control Parameters ..................................................................................................................................... 44 +ETBM=,,—Call Termination Buffer Management ............................... 45 +FCLASS=—Service Class Indication ................................................................................................ 45 +GCAP—Request Complete Capabilities List ................................................................................................. 46 +GCI=—Country of Installation ....................................................................................... 46 +GMI—Manufacturer Identification .................................................................................................................. 46 +GMM—Modem Identification ......................................................................................................................... 47 +GMR—Request Revision Information ............................................................................................................ 47 +IFC=,—DTE-DCE Local Flow Control ...................................................... 48 +ILRR=—DTE-DCE Local Rate Reporting ......................................................................................... 48 +IPR=—Fixed DTE Rate ............................................................................................................... 49 +ITF=,—Transmit Flow Control Threshold ....................................................................................... 49 +MR=— Modulation Reporting Control ............................................................................................... 50 +MS=,,,,,— Modulation Selection .................................................................................................................................... 50 +PCW=—Call Waiting Enable ................................................................................................... 53 +PIG=—PCM Upstream Ignore .......................................................................................................... 53 +PMH=—Modem On Hold Enable ...................................................................................................... 54 +PMHD—Modem On Hold DTMF Dialing .............................................................................. 54 +PMHF—Modem On Hold Hook Flash ............................................................................................................ 54 +PMHR—Initiate Modem On Hold ................................................................................................................... 55 +PMHT=—Modem On Hold Timer ...................................................................................................... 56 +PQC=—V.92 Phase 1 and Phase 2 Control ...................................................................................... 57 +PSS=—Use Short Sequence ............................................................................................................ 57 3 Agere Systems Inc. Controller-Based Modem AT Command Reference Manual Manual, Rev. 1 August 2002 Table of Contents Contents Page FAX Commands .................................................................................................................................................... 58 +FAA=—Adaptive Answer ................................................................................................................... 58 +FCLASS=—Enter Class 1, Class 2 or Class 2.1 FAX Mode ............................................................. 58 +FLO=—Flow Control Selection .......................................................................................................... 59 +FMI?—Manufacturer Identification ................................................................................................................. 59 +FMM?—Product Identification ........................................................................................................................ 60 +FMR?—Version/Revision Information ............................................................................................................ 60 +FPR Commands (continued) .......................................................................................................................... 61 +FRH=—Receive HDLC Data with Carrier ............................................................................... 61 +FRM=—Receive Data ......................................................................................................................... 62 +FRS=—Receive Silence .................................................................................................................... 63 +FTH=—Transmit HDLC Data with Carrier ............................................................................... 63 +FTM=—Transmit FAX Data with Carrier ................................................................................. 64 +FTS=—Transmission Silence ............................................................................................................ 64 Voice Commands ................................................................................................................................................ 65 S32=—Synthetic Ring Volume ............................................................................................................ 65 S33=—Synthesized Ring Frequency ................................................................................................... 65 +FCLASS=8—Enter Voice Mode ..................................................................................................................... 65 +VCID=—Caller-ID ............................................................................................................................ 65 +VDR=,—Distinctive Ringing and Cadence Report ............................................................ 66 +VEM=—Event Reporting and Masking .............................................................................................. 66 +VGM=—Microphone Gain ................................................................................................................... 66 +VGR=—Receive Gain Selection .......................................................................................................... 67 +VGS=—Speaker Gain ......................................................................................................................... 67 +VGT=—Speaker Volume Control ........................................................................................................ 68 +VIP—Initialize Voice Parameters .................................................................................................................... 68 Voice Commands: Speakerphone Operation ...................................................................................................... 70 +VLS=