Preview only show first 10 pages with watermark. For full document please download

Air Conditioning Technical Data

   EMBED


Share

Transcript

Air Conditioning Technical Data Wall mounted unit EEDEN15-100 FTX-J3 • Indoor Unit • FTX-J3 TABLE OF CONTENTS FTX-J3 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 4 3 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 4 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 5 Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 6 Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 7 Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Wiring Diagrams - Single Phase 8 .................................... 9 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Sound Pressure Spectrum • Split - Sky Air • FTX-J3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 1 • Indoor Unit • FTX-J3 1 Features ket tSi n uU - o mr 3t o J i ol - l dl X pnaT WWall IFS 1 mounted unit providing high efficiency and comfort • ECONO mode decreases power consumption so that other appliances that need large power consumption can be used • Vertical auto swing moves the discharge flaps up and down for efficient air and temperature distribution throughout the room • Comfort mode guarantees draught free operation by preventing that warm or cold air is directly blown on to the body • Indoor unit silent operation: "silent" button on the remote control lowers the operation sound of the indoor unit by 3dBA • Titanium apatite photocatalytic air purification filter removes airborne microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air • Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode. • Night set mode saves energy by preventing overcooling or overheating during night time • Online controller (optional): control your indoor from any location with an app, via your local network or internet Econo mode Night set mode Fan speed steps Fan only Comfort mode Powerful mode Auto coolingIndoor unit Vertical auto Auto fan speed heating silent operation swing changeover Dry programmeTitanium apatite 24 hour timer Infrared remote Wired remote control control photocatalytic air purification filter Multi model application 2 • Split - Sky Air • FTX-J3 Online controller via app Auto-restart Self diagnosis • Indoor Unit • FTX-J3 2 Specifications 2-1 Technical Specifications FTX20J3 FTX25J3 Power input - 50Hz Cooling Nom. kW Heating Nom. kW Casing Colour Dimensions Unit Height/Width/ Depth mm 283/770/198 Packed unit Height/Width/ Depth mm 266/846/345 Weight 0.030 0.040 Unit kg 7 kg 11 Packing Weight kg 4 Heat exchanger Length mm 610 mm 1.4 Quantity Quantity 14 Tube type Fin Air filter Type Fan Type Air flow rate ø7 Hi-XA Type ML fin (Multi louver) Removable / washable / mildew proof Cross flow fan Cooling High Nom. Low Silent operati on Heating High Nom. Low Silent operati on Fan motor Output Sound power level Sound pressure level m³/min 9.1 9.2 9.3 cfm 321 325 328 m³/min 7.4 7.6 7.7 cfm 261 268 272 m³/min 5.9 6.0 6.1 cfm 208 212 215 m³/min 4.7 4.8 4.9 cfm 166 169 173 m³/min 9.4 9.7 10.1 cfm 331 342 356 m³/min 7.8 8.0 8.4 cfm 276 283 295 m³/min 6.3 6.7 cfm 222 235 m³/min 5.5 5.7 cfm 194 201 Model Speed 2 2 Fin pitch Stages 3 White Packed unit Rows FTX35J3 MM6C02J2VA Steps 5 + silent, + auto Cooling High/ rpm Mediu m/Low/ Silent operati on 1,210/990/780/630 1,250/1,030/820/630 1,300/1,070/850/680 rpm Heating High/ Mediu m/Low/ Silent operati on 1,260/1,090/920/820 1,300/1,110/920/820 1,340/1,150/960/850 Rated W 16 Cooling dBA 55 Heating dBA 55 58 58 Cooling High/Nom./Low/ Silent operation dBA 39/33/25/22 40/33/26/22 41/34/27/23 Heating Super high/High/ Nom./Low/Silent operation dBA -/39/34/28/25 -/40/34/28/25 -/41/35/29/26 Control systems Infrared remote control Refrigerant Type ARC433A87 R-410A • Split - Sky Air • FTX-J3 3 • Indoor Unit • FTX-J3 2 Specifications 2-1 Technical Specifications Piping connections FTX20J3 OD 6.35 Gas OD 9.5 Drain FTX35J3 18 Heat insulation 2 FTX25J3 Liquid Both liquid and gas pipes Temperature control Microcomputer control Air direction control Right, Left, Horizontal, Downward Standard Accessories : Installation manual; Quantity : 1; Standard Accessories : Operation manual; Quantity : 1; Standard Accessories : Infrared remote control; Quantity : 1; Standard Accessories : AA dry-cell batteries; Quantity : 2; Standard Accessories : Remote control holder; Quantity : 1; Standard Accessories : Mounting plate; Quantity : 1; Standard Accessories : Titanium apatite photocatalytic air purification filter; Quantity : 2; Standard Accessories : Indoor unit fixing screws; Quantity : 2; 2-2 Electrical Specifications Power supply FTX20J3 Name V1 Phase Current 1~ Frequency Hz 50 Voltage V 220-240 Nominal running Cooling current (RLA) - 50Hz Heating A 0.14 A 0.18 Notes SL: The silent fan level of the air flow rate setting 4 FTX25J3 • Split - Sky Air • FTX-J3 FTX35J3 • Indoor Unit • FTX-J3 3 Options 3-1 Options 3 3 • Split - Sky Air • FTX-J3 5 • Indoor Unit • FTX-J3 4 Dimensional drawings 4-1 Dimensional Drawings )7;- 7KHBBBBBBBBBBPDUNVKRZVWKHSLSLQJGLUHFWLRQ 5HDUVLGH 㻣㻣㻜 /HIWVLGH 5LJKWVLGH /LTXLGSLSHº&X7 7KHOHQJWKRIWKHSLSHRXWVLGHWKHXQLWLVPP ,QFOXGLQJPRXQWLQJSODWH 7KHOHQJWKRIWKHSLSHRXWVLGHWKHXQLWLVPP 㻞㻜㻜 )URQWSDQHOIL[LQJVFUHZV /RFDWHGLQVLGHRIWKHXQLW *DVSLSHº&X7 㻝㻥㻤 㻞㻤㻟 1DPHSODWH 㻣㻣㻜 㻡㻠㻥 㻝㻢 %RWWRPVLGH 7HUPLQDOEORFNZLWKHDUWKWHUPLQDO /RFDWHGLQVLGHRIWKHXQLW 'UDLQKRVH &RQQHFWLQJSDUW ,QVLGHGLDPHWHUºPP 2XWVLGHGLDPHWHUºPP 7KHOHQJWKRIWKHFRQQHFWLRQKRVHRXWVLGHWKHXQLWLVPP )ODS 㻝㻜㻝 㻢 4 㻝㻣㻞 2SHUDWLRQODPS 㻠㻝㻚㻟 7LPHUODPS ,QGRRUXQLW2Q2))VZLWFK 㻞㻤㻟 6LJQDOUHFHLYHU 㻡㻠 㻡㻠㻚㻡 㻠㻝㻚㻟 5RRPWHPSHUDWXUHVHQVRU /RFDWHGLQVLGHRIWKHXQLW 1DPHSODWH 㻢㻡 +ROHIRUHPEHGGHGSLSLQJ 6WDQGDUGORFDWLRQRIKROHVLQWKHZDOO 8SGRZQ DXWRPDWLF 㻡㻤 +HDWLQJ &RROLQJ 㻝㻤 r r 凶凳击函击刀 r r 㻝㻢㻟 㻟㻜㼙㼕㼚㻚 ,QGRRUDLUIORZ 0LQLPXPVSDFHIRUDLUSDVVDJH 6LJQDOWUDQVPLWWHU )DQ 'U\ r r r 㻡㻜㼙㼕㼚㻚 㻡㻜㼙㼕㼚㻚 ,QIUDUHGUHPRWHFRQWUROOHU 6HUYLFHVSDFH 6HUYLFHVSDFH $5&$ 5HTXLUHGVSDFHIRUVHUYLFHDQGYHQWLODWLRQ r /HIWULJKW PDQXDO 㻠㻡> 㻠㻡> %ODGHDQJOH ' 6 • Split - Sky Air • FTX-J3 • Indoor Unit • FTX-J3 5 Centre of gravity 5-1 Centre of Gravity 3 )7;- 5 㻣㻣㻜 㻞㻜㻜 㻥㻣 㻞㻤㻟 㻝㻠㻜 㻟㻟㻟 ' • Split - Sky Air • FTX-J3 7 • Indoor Unit • FTX-J3 6 Piping diagrams 6-1 Piping Diagrams )7;- 6 ,QGRRUXQLW +HDWH[FKDQJHU &X7 &X7 &X7 &X7 &X7 7KHUPLVWRU KHDWH[FKDQJHU &URVVIORZIDQ &X7 㻹 )LHOGSLSLQJ )DQPRWRU &X7 &X7 )LHOGSLSLQJ 5HIULJHUDQWIORZ &RROLQJ +HDWLQJ ' 8 • Split - Sky Air • FTX-J3 • Indoor Unit • FTX-J3 7 Wiring diagrams 7-1 Wiring Diagrams - Single Phase 3 7 • Split - Sky Air • FTX-J3 9 • Indoor Unit • FTX-J3 8 Sound data 8-1 Sound Pressure Spectrum FTX20J3 Heatingmode Coolingmode NR90 80 NR85 NR80 NR75 70 NR70 NR65 NR60 60 50 NR55 NR50 NR45 40 NR40 NR35 30 NR30 NR25 NR20 NR0 NR5 63 125 250 NR15 NR10 500 1000 2000 4000 8000 Soundpressurelevel[dB] Soundpressurelevel[dB] 8 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 90 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 20 10 90 NR90 80 NR85 NR80 NR75 70 NR70 NR65 NR60 NR55 60 50 NR50 NR45 40 NR40 NR35 30 NR30 NR5 63 dBA 125 20 NR25 NR0 250 NR10 500 NR15 NR20 10 1000 2000 4000 8000 dBA Octavebandcentrefrequency[Hz] Octavebandcentrefrequency[Hz] Legend dBA=AͲweightedsoundpressurelevel(AscaleaccordingtoIEC). A Scale Cooling B A C Heating TotaldB B C 39 25 TotaldB A B B 39 28 Locationofmicrophone dBA dBA Notes 1 . 2 . Backgroundnoisealreadytakenintoaccount. 3 . Operatingnoisevariesdependingonoperationandambientconditions. 4 . TheoperationnoisemeasuringmethodisinaccordancewithJISC9612. 5 . Measuringlocation:anechoicchamber Operatingconditions:powersource220Ͳ240V/220V50/60Hz;JISstandard FTX25J3 3D092111 s Heatingmode 90 NR90 80 NR85 NR80 NR75 70 NR70 NR65 NR60 NR55 60 50 NR50 NR45 40 NR40 NR35 30 NR30 NR25 NR20 NR0 NR5 63 125 250 NR10 500 NR15 1000 2000 4000 8000 Soundpressurelevel[dB] Soundpressurelevel[dB] Coolingmode 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 20 10 90 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 NR90 70 NR70 NR65 NR60 NR55 60 50 NR50 NR45 40 NR40 NR35 30 NR30 NR0 NR5 63 dBA 80 NR85 NR80 NR75 125 250 500 NR10 NR15 NR25 NR20 20 10 1000 2000 4000 8000 dBA Octavebandcentrefrequency[Hz] Octavebandcentrefrequency[Hz] Legend dBA=AͲweightedsoundpressurelevel(AscaleaccordingtoIEC). A Scale Cooling B C Heating TotaldB TotaldB A B C A B B dBA 40 26 dBA 40 28 Locationofmicrophone Notes 10 1 . Operatingconditions:powersource220Ͳ240V/220V50/60Hz;JISstandard 2 . Backgroundnoisealreadytakenintoaccount. 3 . Operatingnoisevariesdependingonoperationandambientconditions. 4 . TheoperationnoisemeasuringmethodisinaccordancewithJISC9612. 5 . Measuringlocation:anechoicchamber • Split - Sky Air • FTX-J3 3D092112 • Indoor Unit • FTX-J3 8 Sound data 8-1 Sound Pressure Spectrum 3 FTX35J3 Heatingmode 90 NR90 80 NR85 NR80 NR75 70 NR70 NR65 NR60 60 NR55 50 NR50 NR45 40 NR40 NR35 30 NR30 NR25 NR20 NR0 NR5 63 125 250 NR10 500 NR15 1000 2000 4000 8000 Soundpressurelevel[dB] Soundpressurelevel[dB] Coolingmode 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 20 10 90 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 NR90 80 NR75 70 NR70 NR65 NR60 NR55 NR0 NR5 125 250 500 NR10 NR15 8 60 50 NR50 NR45 40 NR40 NR35 30 NR30 63 dBA NR85 NR80 NR25 NR20 1000 2000 4000 8000 20 10 dBA Octavebandcentrefrequency[Hz] Octavebandcentrefrequency[Hz] Legend dBA=AͲweightedsoundpressurelevel(AscaleaccordingtoIEC). A Scale Cooling B A C Heating TotaldB B C 41 27 A TotaldB B B 41 29 Locationofmicrophone dBA dBA Notes 1 . 2 . Backgroundnoisealreadytakenintoaccount. 3 . Operatingnoisevariesdependingonoperationandambientconditions. 4 . TheoperationnoisemeasuringmethodisinaccordancewithJISC9612. 5 . Measuringlocation:anechoicchamber Operatingconditions:powersource220Ͳ240V/220V50/60Hz;JISstandard • Split - Sky Air • FTX-J3 3D092113 11 The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. BARCODE Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende EEDEN15-100 03/15 Copyright Daikin The present publication supersedes EEDEN14-100 Daikin Europe N.V. participates in the Eurovent Certification programme for Liquid Chilling Packages (LCP), Air handling units (AHU), Fan coil units (FCU) and variable refrigerant flow systems (VRF) Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com