AIR HANDLER SPECIFICATIONS 2 TON w\ 10 KW ELECTRIC HEAT MODEL NO. PCME32924T102 Elect. Heat Transformer Motor H.P. FLA @ 240V Wheel (dia x width) Normal CFM Air Filter Size Ref. Connection Suc. Ref. Connection Liq. Aprox. Weight lbs 10 KW 40 va, class 2 ¼ HP 1.9 9x6 800 12x20 ¾” 3/8” 80 Air Flow Speed Low Med High Electrical Data Elect. Heatin Cap. 240V 10 Kw 34,130 BTU/h (CFM vs. EXP " H2O) 0.1 0.2 0.3 0.4 0.5 664 906 940 641 855 927 623 802 914 605 783 884 574 764 854 (240v 60hz 1 ph.) Blower Amps 208V 2 240V 1.9 Minimum Circuit Ampacity 208V 240V 47.6 54.5 Circuit Braker Amps 60 SEE NEXT PAGE FOR MORE DATA – PS050003 ECN 5163-MA 100916 1 AIR HANDLER SPECIFICATIONS A 36" B 22" C 15" Supply Duct Opening Return Duct Opening Depth Width Depth Width 17" 13" 20.35" 12.20" SEE NEXT PAGE FOR MORE DATA – 2 AIR HANDLER SPECIFICATIONS FEATURES: Suitable for use with R410A Rifled Copper Tubing Patented lance fin design Ratings in conformity with ARI Standard 210 ETL Listed 208 / 240-60-1 Slide-out blower and coil assembly Dynamically balanced blowers for quiet vibration Dual ¾” FPT condensate drains on left and right sides Drain pans are molded of corrosion proof engineering polymer H.P. expansion valve All drain pans have Microban protection, which inhibits growth of mold and mildew 3 speed motor Refrigerant connections of 3/8” ODF liquid and ¾” ODF suction Upflow and Horizontal left and right Electrical connections can be made on top, right, or left side Filter rack built into every air handler (filter not provided) Easy to follow wiring diagrams 3