electrical
• Premium quality recessed air handling troffer for: – Grid inverted T (NEMA “G”) ceilings – Flange for concealed mechanical suspension (NEMA “F”) – Modular and “Z” Spline (NEMA “M/Z”) ceilings – Screw Slot (NEMA “SS”) with door frame at ceiling plane – Contact Philips Day-Brite for other ceiling types. • Select one of the four air handling functions: – Static; non-air handling – Heat transfer; air return through lamp compartment – Air supply; (or air return) through side slots, adjustable pattern control blade is optional – Combination; both heat transfer and air supply features listed above • Air boots by others.
• Class P, HPF, CBM certified ballasts comply with E Federal Ballast Law (Public Law 100-357, 1988). • UL listed for damp locations. C.S.A. certified optional. • Self-contained fluorescent emergency power packs can be incorporated (1 and 2 lamp fixtures only).
construction/finish • Die formed ribbed and embossed steel housing. • Housing is multi-stage phosphate treated for maximum corrosion resistance and finish coat is high reflectance baked white enamel. • Access plate (2 K.O.’s) factory installed includes grounding screw. • T-bar grid clips (UL listed) built into fixture end plates, no extra parts required.
510-AH Air Handling DGA 1x4 1, 2, or 3 Lamp T8 or T5
enclosure • Black reveal produces floating door appearance. • Mitered corner door frames with a choice of: Flat Aluminum or Regressed Aluminum. • Door frames standard with guide post spring loaded latches. • Mechnically designed interlocks block light, no gaskets are needed. • Prismatic acrylic pattern 12 lens standard (01). Other lenses or louvers optional. • Choice of door finishes; white (standard), or black.
Specifier’s Reference Project Type Model No. Comments
Green Choice: 1DG132-FS01-UNV-1/1EBHE-LPT835HL 1
–
Width
Ceiling Type
1 – 1'
Family
G – Grid F – Flange Z – Z Spline/ Modular T – Screw Slot
No. of Lamps (not included) 1 2 3
Door Frame
Air Function
–
Lamp Type/Wattage
Accessories
FKDP14 – Flange conversion kit 1x4 FMA14 – 1'x4' “F” mounting frame for NEMA “F” mounting TPDTH – Torx head pin driver (sold separately)
© 2013 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires 510-AH 04/13
Options
APC – Air pattern control blades ASC – Snap out air slot covers PAF – Housing painted after stamping 1/2 – One 2-lamp ballast 1/3 – One 3-lamp ballast 1/21 – 2-lamp & 1-lamp ballasts 1/1-EB – One 1-lamp ballast EB – Electronic ballast, <20% THD EB10I – T8/CF electronic ballast, instant start, <10% THD EB10R – Electronic ballast, program rapid start, <10% THD EBHE – T8 electronic ballast, high efficiency, std. ballast factor EBLHE – T8 electronic ballast, high efficiency, low ballast factor EBHHE – T8 electronic ballast, high efficiency, high ballast factor Voltage Lens E1 – DEB-1 emerg. ballast, T8/CF, 350-450 lumens 120 E7 – DEB-7 emerg. ballast, T8/CF, 600-700 lumens 01 – Pattern 12 prismatic 277 E5 – DEB-5 emerg. ballast, T8/CF, 1100-1400 lumens acrylic 347 E5ST – DEB-5ST emerg. ballast w/self test, T8/CF, 12 – DB-12, .125" UNV – Universal 1100-1400 lumens nominal voltage, E7LP – DEB-7LP emerg. ballast T8/T5/T5HO, 19 – DB-19, .156" 120-277 volt 430-700 lumens nominal (with T8 and E6LP – DEB-6LP emerg. ballast, T8/T5/T5HO, 21 – Pattern 12, .125" 40WTT5 750-1325 lumens nominal electronic F1 – Installed flex, 3/8" diameter, 18 gauge, 3 wire, 6' 30 – 1/2"x1/2"x1/2" silver ballast only) F2 – Installed flex, 3/8" diameter, 18 gauge, 4 wire, 6' plastic louver GLR# – Fusing, fast blow (# = number of ballasts) 34 – 1-1/2"x1-1/2"x1" IC – Suitable for Type-IC (insulated ceiling) silver plastic louver applications (32W 2x4 only) 52 – 3/4"x3/4"x1/2" silver LPT735 – Installed T8 lamps, 70+ CRI, 3500K plastic louver LPT835HL – Installed T8/T5 hi lumen lamps, 80+ CRI, 3500K 56 – Vanguard high 1W – 1-way gasketing, between lens & door frame impact 3/16" acrylic 2W – 2-way gasketing, 1W + gasketing between door frame 93 – drop dish acrylic & housing 131 – Pattern 12, .187" 3W – 3-way gasketing, 2W + gasketing for field installation nominal (use for 3x3 between housing & ceiling or 4x4) SI – Specular Insert (reflector)
FS – Flat Steel FA – Flat Aluminum RA – Regressed Aluminum TFS – Tamper Resistant Flat Steel
28 – 28WT5 (46") Blank – Static (no black D – Designer 32 – 32WT8 (48") reveal) DC – Canadian 54HO – 54WT5HO (46") A – Air Supply Certified Model C – Combination DCP – Chicago Plenum (A&H) Model H – Heat Transfer S – Static (no air function) but with black reveal U – Universal (3x3 and 4x4)
Door Finish
–
LANK – White B B – Black Door
510-AH
DGA 1x4 1, 2, or 3 Lamp T8 orT5
dimensions
Optional Air Pattern Control (on Air and Combination Units) • Fully adjustable – Closed= Static – 45°= Horizontal Air Supply – 90°= (fully open) – Vertical Air Supply • Side Slots may also be used for Return Air to Plenum
Access plate location
Luminaire end
Locking tab screwdriver slot
7/8" dia. K.O.s 7/8" dia. hole
1-1/2"
Grid clip
Access plate
Open to min. 1/8" with screwdriver
Grid tees (by others)
Open with screwdriver and bend to 90º 7/8" dia. K.O.
ceiling configuration
1
D
G
S
1
32
Ceiling type G = Grid (NEMA G)
F = Flange (NEMA F)
T = Screw Slot (NEMA SS)
Z = Modular & “Z” Spline (NEMA M/Z)
SIDE
SIDE
SIDE
SIDE
3-3/4" Max. 1-1/4" Min. 12" (304.8 mm) (NEMA Type G) Lay-in acoustical ceilings using exposed grid suspension, with tees for luminaires on 12" x 48" spacing.
3-3/4" Max. 1-1/4" Min.
12"
13" (330.2 mm) (NEMA Type F) Flange for acoustical ceilings using concealed mechanical suspension. Swing-jack mounting brackets: adjustment 3-3/4" max.and 1-1/4" min.
12" (304.8 mm)
(304.8 mm) Lensed fixture with door frame at the ceiling plane.
(NEMA M/Z) Modular and “Z” Spline using concealed mechanical suspension. Swing-jack mounting brackets: adjustment 3-3/4" max. and 1-1/4" min.
(NEMA Type SS) Typical Screw Slot Ceiling System.
photometry DGA 1x4 1 Lamp T8
Efficiency – 72.6%
Catalog No.
1DGS132-FA01-1/1-EB
Test No.
15550
S/MH
1.4
Lamp Type
F32T8
Lumens/Lamp
2900
Ballast Factor
1.00
Input Watts
35
Comparative yearly lighting energy cost per 1000 lumens – $4.00 based on 3000 hrs. and $.08 pwr KWH. The photometric results were obtained in the Philips Day-Brite laboratory which is NVLAP accredited by the National Institute of Standards and Technology.
Angle
End
45
Cross
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
892 888 877 858 830 794 745 680 603 517 408 311 233 168 118 84 52 25
892 890 887 881 871 859 839 790 662 527 394 267 168 108 79 61 40 23
892 893 896 904 910 911 889 808 669 508 383 298 225 165 118 86 55 25
© 2013 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires 510-AH 04/13
LER – 60
Candlepower
TER – 55
Light Distribution
Average Luminance
egrees Lumens % Lamp % Luminaire D 0-30 728 25.1 34.6 0-40 1203 41.5 57.2 0-60 1863 64.2 88.5 0-90 2104 72.6 100.0
Angle 45 55 65 75 85
End 2922 2167 1589 1297 1146
45° 2979 1860 1021 942 1055
Cross 2871 2076 1560 1328 1146
Coefficients of Utilization EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20) pcc 80 70 50 pw 70 50 30 70 50 30 50 RCR 0 85 85 85 83 83 83 81 1 80 77 73 78 75 72 71 2 73 68 64 71 67 63 65 3 68 60 56 66 59 55 57 4 63 55 48 60 54 48 52 5 57 50 44 56 48 42 46 6 54 45 39 53 44 39 42 7 50 40 34 48 40 34 40 8 46 38 32 46 36 32 35 9 44 34 28 42 34 28 34 10 40 32 27 40 32 27 30
30 81 69 60 54 47 42 38 34 30 28 26
510-AH
DGA 1x4 1, 2, or 3 Lamp T8 orT5
dimensions
Optional Air Pattern Control (on Air and Combination Units) • Fully adjustable – Closed= Static – 45°= Horizontal Air Supply – 90°= (fully open) – Vertical Air Supply • Side Slots may also be used for Return Air to Plenum • Snap-in Air Slot Covers (ASC) also available
Access plate location
Luminaire end
Locking tab screwdriver slot
7/8" dia. K.O.s 7/8" dia. hole
1-1/2"
Grid tees (by others)
Grid clip Open to min. 1/8" with screwdriver
Access plate Open with screwdriver and bend to 90º 7/8" dia. K.O.
photometry DGA 1x4 2 Lamp T8
Efficiency – 66.8%
Catalog No.
1DGS232-FA01-1/2-EB
Test No.
15551
S/MH
1.1
Lamp Type
F32T8
Lumens/Lamp
2900
Ballast Factor
0.92
Input Watts
59
Comparative yearly lighting energy cost per 1000 lumens – $4.00 based on 3000 hrs. and $.08 pwr KWH. The photometric results were obtained in the Philips Day-Brite laboratory which is NVLAP accredited by the National Institute of Standards and Technology.
Angle
End
45
Cross
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
1909 1904 1876 1830 1762 1669 1540 1379 1175 969 752 569 422 306 219 154 97 43
1909 1896 1866 1810 1715 1600 1467 1332 1134 911 692 478 308 200 149 113 74 41
1909 1895 1857 1785 1676 1550 1441 1303 1133 883 663 513 394 293 215 156 98 45
© 2013 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires 510-AH 04/13
LER – 60
Candlepower
TER – 55
Light Distribution
Average Luminance
egrees Lumens % Lamp % Luminaire D 0-30 1428 24.6 36.8 0-40 2258 38.9 58.3 0-60 3434 59.2 88.6 0-90 3875 66.8 100.0
Angle 45 55 65 75 85
End 5477 3965 2894 2378 1972
45° 5149 3331 1891 1745 1880
Cross 4991 3574 2771 2409 2063
Coefficients of Utilization EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20) pcc 80 70 50 pw 70 50 30 70 50 30 50 RCR 0 80 80 80 78 78 78 73 1 73 70 68 71 69 67 67 2 68 63 58 66 61 58 59 3 63 56 52 60 56 51 54 4 57 51 46 56 50 45 48 5 54 46 40 53 46 40 44 6 50 41 36 48 40 35 40 7 46 39 33 46 38 33 36 8 44 34 29 42 34 29 34 9 40 33 28 40 32 27 32 10 39 29 25 38 29 25 28
30 73 65 56 50 44 40 35 32 29 27 25
510-AH
DGA 1x4 1, 2, or 3 Lamp T8 orT5
dimensions
Optional Air Pattern Control (on Air and Combination Units) • Fully adjustable – Closed= Static – 45°= Horizontal Air Supply – 90°= (fully open) – Vertical Air Supply • Side Slots may also be used for Return Air to Plenum
Access plate location
Luminaire end
Locking tab screwdriver slot
7/8" dia. K.O.s 7/8" dia. hole
1-1/2"
Grid tees (by others)
Grid clip Open to min. 1/8" with screwdriver
Access plate Open with screwdriver and bend to 90º 7/8" dia. K.O.
photometry DGA 1x4 3 Lamp T8
Efficiency – 62.1%
LER – 61
Candlepower
Catalog No.
1DGS332-FA01-1/3-EB
Test No.
15555
S/MH
1.2
Lamp Type
F32T8
Lumens/Lamp
2900
Ballast Factor
0.93
Input Watts
82
Comparative yearly lighting energy cost per 1000 lumens – $3.93 based on 3000 hrs. and $.08 pwr KWH. The photometric results were obtained in the Philips Day-Brite laboratory which is NVLAP accredited by the National Institute of Standards and Technology.
Angle
End
45
Cross
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
2634 2619 2583 2520 2430 2313 2147 1920 1648 1346 1043 789 578 420 300 213 135 61
2634 2623 2586 2522 2420 2291 2125 1920 1597 1268 958 640 404 265 197 153 99 58
2634 2619 2581 2510 2406 2269 2103 1845 1528 1179 901 705 545 402 290 209 133 62
TER – 56
Light Distribution
Average Luminance
egrees Lumens % Lamp % Luminaire D 0-30 2013 23.1 37.2 0-40 3194 36.7 59.1 0-60 4808 55.3 88.9 0-90 5406 62.1 100.0
Angle 45 55 65 75 85
End 7608 5498 3972 3289 2797
45° 7167 4459 2506 2363 2660
Cross 6664 4912 3802 3227 2843
Coefficients of Utilization EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20) pcc 80 70 50 pw 70 50 30 70 50 30 50 RCR 0 73 73 73 71 71 71 68 1 68 66 64 67 65 63 61 2 63 58 55 61 57 55 56 3 58 53 47 56 52 47 50 4 54 47 42 53 46 41 45 5 50 42 38 48 41 38 40 6 46 39 34 46 39 34 38 7 44 35 30 42 34 30 34 8 40 33 28 40 33 28 32 9 38 30 26 36 29 26 28 10 35 28 23 34 28 23 27
30 68 59 53 46 40 36 33 29 28 25 23
Some luminaires use fluorescent or high intensity discharge (HID) lamps that contain small amounts of mercury. Such lamps are labeled, “Contain Mercury” and/or the symbol “HG”. Lamps that contain mercury must be disposed of in accordance with local requirements. Information regarding lamp recycling and disposal can be found at www.lamprecycle.org
© 2013 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires 510-AH 04/13
Philips Lighting Company 200 Franklin Square Drive Somerset, NJ 08873 Phone: 855-486-2216
Philips Lighting Company 281 Hillmount Road Markham ON, Canada L6C 2S3 Phone: 800-668-9008